theernher 10, 1997 l

l Dr. Brain Dodd, Director Radiation Center Oregon State University 100 Radiation Center Corvallis, Oregon 97331 5903

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. MA0200)

Dear Dr. Dodd:

We are continuing our review of your amendment request for Amended Facility Operating License 1o. R 4 00 for the Oregon State University Research Reactor that you submitted on Nover aer 25,1997. During our review of your amendment request, questions have arisea for

'ich we require additionalinforrnation and clarification. Plecse provide responses to

..:losed request for additionalinformation within 30 days of the date of this letter. In ordance vith 10 CFR 50.30(b), your response must be executed in a signed original t

uns e oath or of firmation. This request affects nine or fewer respondents and therefore, is not.Jbject to Of fice of Management and Budget review under P.L. 90 511. Following receipt of the additionalinf irmation, we will continue our evaluation of your amendment request.

If you have any questions regarding this review, picaso contact me at (301) 4151127.

Sincerely, Original signed by:

Alexander Adams, Jr., Senior Project Manager Non Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management

(

Office of Nuclear Reactor Regulation Docket No. 50 243

Enclosure:

f As stated l

cc w/ enclosure:

See next page DISTRIBUTION:

Docket File 50 243 PUBLIC PDND r/f WEresian JRoe EHylton AAdams OGC SWeiss Pisaac TMichaels MMendonca Sholmes C8assett TDragoun TBurdick PDoyle Region IV

.y P,9

LA PDND:PM RDN iD Jt Ito.

AA SWeiss Il /8/97 LM

{k/@97 OFFICIAL RECORD COPY DOCIIMENT NAME: G:\\SECY\\ ADAMS \\243RAll.16 g

y NM RLE CENTER @py '

DR D

0 3

-,,,.~.m k

UNITED STATES p

s

,}

NUCLEAR REGULATORY COMMISSION

'j WASHINGTON, D.C. 3000H001 o....

December 10, 1997 Dr. Brain Dodd, Director Radiation Center Oregon State University 100 Radiation Center Corvallis, Oregon 97331 5903

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. MA0200)

Dear Dr. Dodd:

l We are continuing our review of your amendment request for Amended Facility Operating Ucense No. R 106 for the Oregon State University Research Reactor that you submitted on November 25,1997. During our review of your amendment request, questions have arisen for which we require additionalInformation and clarification. Please provide responses to the enclosed request for additionalinformation within 30 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. This request affects nine or fewer respondents and therefore,is not subject to Office of Management and Budget review under P.L. 96 511. Following receipt of the additionalinformation, we will continue our evaluation of your amendment request.

If you have any questions regarding this review, please contact me at (301) 4151127.

Sincerely, dbh4 l

Alexander Adams, Jr., Se or roject Manager Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Managernent Office of Nuclear Reactor Regulation Docket No. 50-243

Enclosure:

As stated cc w/ enclosure:

See next page l

)

Oregon State University Docket No. 50 243 cc:

Mayor of the City of Corvallis Corvallis, Oregon 97331 M. W. Alsworth Oregon Department of Energy 625 Marion Street, N.E.

Setem, Oregon 97310

+

REQUEST FOR ADDITIONAL INFORMATION OREGON STATE UNIVERSITY RESEARCH REACTOR l

DOCKET NO. 50 243 1.

In your proposed technical specification (TS) 6.1 b., you changed the title of Vice Provost for Research and International Program to Vice Provost for Research. You also changed this title in TS 6.1 a. but your amendment application did not discuss this specific char.ge. Please clarify.

i 2.

In your proposed TS 6.7, you changed reporting by telegraph to reporting by fax. You i

did not discuss this specific change in your application. Note that TS 6.7 b.1.

con' ins a reference to telegraph reports but was not requested to be changed by you.

Please address.

3.

In TS 6.7e.2. you removed the period at the end of the TS. Is this a requested change or was it an error that occurred when you retyped the page?

1 i

t l

l

-