ML20197H315

From kanterella
Jump to navigation Jump to search

Rev 19 to AR-401, PSA F Annunciator Response
ML20197H315
Person / Time
Site: Crystal River 
Issue date: 12/22/1997
From:
FLORIDA POWER CORP.
To:
References
AR-401, NUDOCS 9712310246
Download: ML20197H315 (188)


Text

.

Document Transmittal #: 80569 Date: 12/22/97 TO:- NRC (DC DESK)

MAC: N/A Destination:

==

Description:==

Copy Copy Totals -

Document:

Revision:

Comment:

INFO CNTL MSTR AR0401.

19-24 1

0 0

I instructions to the Addressee:

Pl:ase "erify the document (s) received agrees with the above information.

Operations department must attach old document (s) or portions of document (s) superseded by the above

' ta this transmittal, The signature indicates acknowledgment of receipt of the above document (s) and that documents have been updated. Retum signed and dated transmittal to Document Control within 15 working days of

. transmittal date to mall code:

D Power Corporaten l

  • a,, ;

j j

j Document Control, NA1C

- <d U' b.L U

~ Crystal RAror Energy Complex q9- ?O 15780 W. Power une St.

Crystal River, FL 34428-6708 Sigmture of Addressee:

Date:

9712310246 971222 PDR ADOCK 05000302 P

PDR

W Rev. 19

.j I Lf %%!9 9 Effective Date INFOR VIATlON L

ONLY J

ANNUNCIATOR RESPONSE AR-401 FLORIDA POWER CORPORATION CRYSTAL RIVER UNIT 3 PSA F ANNUNCIATOR RESPONSE 4

i APPROVED BY: Interpretation Contact Ynn/ ~1Nsk 17)At

~

I (SIGNATURE 0N FILE)

/2/8 97 DATE:

f] -

[

- b/ -

INTERPRETATION CONTACT: Manager, Nuclear Plant Operations Support i>

TABLE OF CONTENTS'

-( m ;.

Y L'

SECTION PAGE

~1.0 PUR?0SE..........'...........'............................................ 1 t

2.0 REFERENCES

............................................................. 1-2.1 IMPLEMENTING REFERENCES............................................ 1 2.2 DEVELOPMENTAL REFERENCES.............................................Y 3.0 PERSONNEL INDOCTRINATION........................................i.......

1 4.0-1NSTRUCTIONS....'..............'.......................................;... 2 R FOLLOW-UP ACTIONS.......................................................

2 ENCLOSURES 1

Annunciator Response............................................... 3 i' A-

Q T

W l

, - ry.

N.)

l i

AR-401 Rev. 19 Page i

--.m-

'1.0' PURPOSE' L;- s)

' i

(_-

1.1-Establish a' reference document for each Annunciator Window on the PSA-X Lampbox.

1,2 Establish operator status.for valid Annunciator alarms on the PSA-X Lampbox.

71.3

. Establish a reference to other procedures which address operator actions for valid Annunciator alarms on the PSA-X Lampbox.

2.0 REFEPENCES 2.1 IE L M EIING REFERENCES 2.1.1-OP-409 - Plant Ventilation 2.1. 2 '

OP-417 - Containment Operating Procedure 2.1.3-OP-703 - Plant Distribution System 2.1.4 AP-250 - Radiation Monitor Actuation i

2.1.5 AP-513 - Toxic Gas 2.1.6 AP-880 - Fire Protection L2.1.7 OP-417A - Industrial Cooling System 2.1.8 SP-300 - Operating Daily Surveillance Log 2.1.9 PM-294 - Calibration of Robert Shaw Vibra Switches

'2.2 (lWMMTAL REFEREN(ES 2.2.1 INPO 90-021, Good Practice OP-217, Alarm Response Procedures 2.2.2 Annunciator Window Engraving Drawing E-224-048 3.0' PERSONNEL'INDOCTRINATIM 3.1-

'The Annunciator System is powered ' rom VBDP-5 Breaker 28.

A (l'

AR-401' Rev. 19 Page 1

. _.... _ _ _. _. _. _ _. _... _. _ ~. _. _... _ _ _.

't M

14.0 E

~-INSTRUCTIONS si' 74.1-Respond to alarms on the PSA-X Lampbox as indicated on Enclosure 1.-

Annunciator Response.

i 5.0-FOLLOW-UP ACTIONS T

None-4 ':

i-s t

?-

f 3

}.

I

i. -

3.

~

2 I

d a

a r

s i

j' I

3.

i i.

o 4

1 i

i l0

[

I.-

p

-: AR-401 Rev. 19 Page 2 7.--

L..

ENCLOSURE 1 i

(Page 1_of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-01 F-01-01.

4 l

l

. CNTRL COMPLEX l

l FAN l

l TRIP I

I 1

-l l

I EVENT POINT 0466 INDICATID CONDITION:

o AHF-17A MOTOR IS NOT ENERGIZED WITH CONTROL HANDLE IN NORMAL AFTER START POSITION O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON CONTROL STATION o RADIATION HIGH RAD ALARM RM-A-5 OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF TRIP o START AHF+178

.o RESTORE VENTILATION PER OP-409 o REFER TO AP-250 DISCUSSION:

REFERENCES:

DRAWING 208-005 SHEET AH-80 SENSING ELEMENT: CS/SC, CS/0, 428 ARJ401 Rev,'19 Page 3

k 9

4 ENCLOSURE 1-(Page-2 of 183)-

PSA ANNUNCIATOR RESPONSE lPSA-X-01-01 F-01-01 I

CNTRL COMPLEX I

FAN TRIP l-I EVENT POINT 0467 F

INDICATED CONDITION:

o AHF-17B MOTOR IS NOT ENERGIZED WITH CONTROL HANDLE IN NORMAL AFTER

. START-POSITION

'i) t' REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

g o GREEN LIGHT ON WITH A RED FLAG ON CONTROL STATION o RADIATION HIGH RAD ALARM RM-A-5 OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF TRIP o REFER TO AP-250 o START AHF-17A o RESTORE VENTILATION PER OP-409 DISCUSSION:

REFERENCES:

DRAWING 208-005 SHEET AH-81

(~~

SENSING ELEMENT:

CS/SC, CS/0, 428--

b}

..AR-401 Rev. 19

.Page 4

. = -

ENCLOSURE'1

.(

).

(Page 3 of 183)

% Ji PSA ANNUNCIATOR RESPONSE-PSA-X-01-01 F-01-01 5

I CNTRL COMPLEX I

FAN l

TRIP I

l EVENT POINT 0470 INDICATED CONDITION:

o AHF-18A MOTOR IS NOT ENERGIZED WITH CONTROL HANDLE IN NORMAL AFTER START POSITION IM

'J REDUNDANT INDICATION WHICH WILL VERIFY ALARM

g GREENLIGHTONWITHAREDFLAGONkHF-18ACONTROLSTATION o

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE -THE CAUSE OF TRIP o' START AHF-18B o? RESTORE VENTILATION PER 09-409-DISCUSSION:

REFER TO TECH SPECS FOR ADMINISTRATIVE REQUIREMENTS.

REFERENCES:

DRAWING 208-005 SHEET'AH-82

-m

.)

SENSING ELEMENT:

CS/SC, CS/0, 42B AR-401

-Rev. 19 Page 5

L, i

ENCLOSURE 1.'

/]

(Page 4 of 183).

'%J PSA ANNUNCIATOR RESPONSE PSA-X-01-01

.F-01-01 l

l-CNTRL COMPLEX-1 I

FAN I

I TRIP l

1 l

1 I

EVENT POINT 0471-INDICATED CONDITION:

o -AHF-18B MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION

)

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-188 CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF TRIP i

o START AHF-18A RESTORE VENTILATION PER OP-409 o

DISCUSSION:

EFER TO TECH SPECS FOR ADMINISTRATIVE REQUIREMENTS l

l j.

REFERENCES:

ORAWING 208-005 SHEET AH-83 l.

SENSING ELEMENT: CS/SC. CS/0, 42B

.AR-401 Rev. 19 Page 6 g

-P--

+

w w

~

ENCLOSURE 1 r^(

7C/;

(Page 5 of 183)

PSA ANNUNCIATOR RESPONSE-PSA-X-01-01 F-01-01 l

l CNTRL COMPLEX l

i FAN I

I TRIP I

I I

I I

I EVENT POINT 0478 INDICATED CONDITION:

o~

AHF-19A MOTOR IS NOT ENERGIZED WITH CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CREEN LIGHT ON WITH A RED FLAG ON AHF-19A CONTROL STATION o RADIATION HIGH RAD ALARM RM-A-5 OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE THE CAUSE OF TRIP i

o REFER TO AP-250 o START AHF-19B o-RESTORE VLNTILATION PER OP-409 DISCUSSION:

't

REFERENCES:

DRAWING 208-005 SHECT AH-86 j

SENSING ELEMENT: 'CS/SC, CS/0, 42B AR-401 Rev. 19 Page 7

l 4

ENCLOSURE 1 e

(

(Page 6 of 183)

-PSA ANNUNCIATOR RESPONSE' PSA-X-01-01 F-01-01~

+

. l l

CNTRL COMPLEX l

l FAN 1-l TRIP 1

I I

I I

I EVENT POINT 0479

.i INDICATED CONDITION:

o AHF-198 MOTOR IS NOT Ei4ERGIZED WITH CONTROL HANDLE IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-19B CONTROL STATION o RADIATION HIGH RAD ALARM RM-A-5 i

OPERATOR' ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF TRIP o START-AHF-19A

=o RESTORE VENTILATION PER OP-409 o REFER TO AP-250 DISCUSSION:

REFERENCES:

DRAWING 208-005 SHEET AH-87 SENSING ELEMENT: CS/SC,-CS/0, 42B AR-401

- Rev. 19 Page 8

ENCLOSURE 1 My/

(Page 7 of 183)

/

.PSA ANNUNCIATOR. RESPONSE PSA-X-01 lF-01-01 l

l CNTRL COMPLEX 1

I FAN l

l TRIP I

I I

l l

l-EVENT POINT 0482 INDICATED CONDITION:

o. AHF-20A MOTOR FAST. SPEED WINDINGS ARE NOT ENERGIZED, CONTROL HANDLE IN THE-PUSHED IN NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN FAST SPEED LIGHT ON WITH A RED FLAG ON A3F-20A CONTROL STATION o RADIATION HIGH RAD ALARM RM-A-5 o T0XIC GAS ACTUATION OPERATOR ACTIONS FCA A VALID ALARM:

o INVESTIGATE THE CAUSE OF TRIP

..o NOTIFY CHEMISTRY SAMPLE HOOD VENTILATION IS SECURED o REFER TO OP-409 o REFER TO AP-250 OR AP-513 DISCUSSION:

'IT MAY BE POSSIBLE.TO OPERATE AHF-20A/B IN SLOW SPEED WITH AHF-44A/B IN.

OPERATION T0' PROVIDE CHEMISTRY SAMPLE HOOD VENTILATION

REFERENCES:

DRAWING-208-005 SHEET AH-88

()

SENSING ELEMENT: CS/SC, CS/0, NC/LAT, 428 AR-401 Rev. 19 Page 9 L

.~

.~

ENCLOSURE 1 (Page 8 of 183)

PSA ANNUNCIATOR RESPONSE PF' X-01 01

.F-01-01 l

l CNTRL COMPLEX l

i FAN I

l-TRIP l--

1 I

I I

I EVENT POINT 0483 INDICA 1ED CONDITION:

o AHF-20A MOTOR SLOW SPEED WINDINGS ARE NOT ENERGIZED, COMTROL HANDLE IN THE PULLED OUT NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GR2EN SLOW SPEED LIGHT ON WITH A RED FLAG ON AHF-20A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF TRIP o NOTIFY CHEMISTRY SAMPLE HOOD VENTILATION IS SECURED o REFER TO OP-409 4

DISCUSSION:

REFERENCES:

DRAWING 208-005 SHEET AH-88 SENSING ELEMENT:

CS/SC, CS/0, NC/LAT, 42B AR-401-Rev. 19 Page 10

a FNCLOSURE 1 fj

_(Page 9 of 183).

.(A PSA ANNUNCIATOR RESPONSE-PSA-X-01-01 F-01-01 i

-l

~j o

i l

l CNTRL COMPLEX i

l l

FAN l

l

. TRIP I

I I

I I

I EVENT POINT 0484 INDICATED CONDITION:

o AHF-20B MOTOR FAST SPEED WINDINGS-ARE NOT ENERGIZED, CONTROL HANDLE IN-THE PUSHED IN NORMAL AFTER START POSITION ~

p)

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN FAST SPEED LIGHT ON WITH A RED FLAG ON AHF-20B CONTROL STATION o RADIATION HIGH RAD ALARM RM-A-5 o T0XIC CAS ACTUATION OPERATOR ACTIONS FOR A VALID ALARM:

.o INVESTIGATE THE CAUSE OF TRIP o NOTIFY CHEMISTRY SAMPLE' HOOD VENTILATION IS SECURED o REFER TO OP-409' o REFER TO AP-250 OR AP.-513 DISCUSSION:

IT HAY BE POSSIBLE TO OPERATE AHF-20A/B IN SLOW SPEED WITH AHF-44A/B IN OPERATION TO PROVIDE-CHEMISTRY SAMPLE HOOD VENTILATION

REFERENCES:

DRAWING 208-005 SHEET AH-89

.r,Q

()

SENSING ELEMENT:. CS/5C, CS/0, NC/LAT, 42B 4

AR-4011 Rev. 19 Page 11 w

1.

- f-4..

ENCLOSUEE_1 l

. \\.._()

~(Page.10 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01 F-01-01 l-l CNTRL COMPLEX

- 1 I

FAN

+

1 l

TRIP l

I I

I I

I EVENT POINT 0485 INDICATED CONDITION:-

f o.-AHF-208 MOTOR SLOW SPEED WINDINGS ARE NOT ENERGIZED, CONTROL HANDLE IN

-THE PULLED OUT NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

CREEN'SLOWSPEEDLIGHTONWITHAitEDFLAGONAHF-20BCONTROLSTATION o

OPERATOR ACTIONS FOR A VALID ALARM:

c' INVESTIGATE THE'CAUSE OF TRIP o NOTIFY CHEMISTRY SAMPLE HOOD VENTILATION IS SECURED o REFER TO OP-409 DISCUSSION:

REFERENCES:

DRAWING 208-005 SHEET AH-89

.V SENSING ELEMENT: CS/SC, CS/0, NC/LAT, 42B

- AR-401' Rev. 19 Page 12

ENCLOSURE 1 fN

() -

(Page-11 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-01'

-F-01-01 l

CNTRL COMPLEX I

FAN I

TRIP I

l-EVENT POlnlT 0491 INDICATED CONDITION:

o AHF-30 MOTOR IS NOT ENERGIZED WITH THE CONTRLL HANDLE IN NORMAL AFTER START POSITION

'r O V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-30 CONTROL STATION o T0XIC GAS ACTUATION o RADIATION-HIGH RAD ALARM RM-A5 OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF TRIP o -REFER TO OP-409-o REFER TO AP-250 OR AP-513 DISCUSSION:.

i

REFERENCES:

DRAWING 208-005 SH2ET AH-93 (f

SENSING ELEMENT: CS/SC, CS/0, 428 v

AR-401 Rev. 19 Page 13

l ENCLOSURE 1

]

f'y (Page 12 of 183)

()

PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 l

4 l

l CNTRL COMPLEX AIR FLOW LOW EVENT POINT 0308 INDICATED CONDITION:

I o AIR FLOW FROM "A" BATTERY ROOM IS LOW AS SENSED BY AH-734-FS

]i REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o POSSIBLE FIRE DAMPER ALARMS OFERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE THE CAUSE OF ALARM o CHECK. FOR FIRE DAMPER OPERATION HAVE CHEMISTRY SAMPLE BATTERY ROOM FOR H, CONCENTRATIONS o

DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FIRE DAMPER ACTUATION, CHECK FIRE DAMPERS IN THE CORRECT-POSITION. THIS LOSS OF FLOW FROM THE BATTERY ROOM'COULD RESULT IN A BUILD UP OF HYDROGEN INSIDE THE BATTERY RCOM.

CONSIDEF(ATION SHOULD BE GIVEN TO VENTILATING THE AREA TO PREVENT THE POSSIBILITY OF AN EXPLOSIVE MIXTURE DEVELOPING.

REFERENCES:

DRAWING-208-005 SHEET AH-131 7'T Oi f SENSING ELEMENT: :AH-734-FS AR-401-Rev. 19

.Page 14

ENCLOSURE 1

[^)

(Page 13 of 183)

-v PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 CNTRL COMPLEX AIR FLOW LOW EVENT POINT 0309 INDICATED CONDITION:

o AIR FLOW FROM "B" BATTERY ROOM IS LOW AS SENSED BY AH-735-FS l

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o POSSIBLE FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF ALARM i

o CHECK FOR FIRE DAMPER OPERATION HAVE CHEMISTRY SAMPLE BATTERY ROOM FOR H, CONCENTRATIONS o

DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FIRE DAMPER ACTUATION, CHECK FIRE DAMPERS IN THE CORRECT POSITION. THIS LOSS OF FLOW FROM THE BATTERY ROOM COULD RESULT IN A BUILD UP OF HYDROGEN INSIDE THE BATTERY ROOM.

CONSIDERATION SHOULD BE GIVEN TO VENTILATING THE AREA TO PREVENT THE POSSIBILITY OF AN EXPLOSIVE MIXTURE DEVELOPING.

REFERENCES:

DRAWING 208-005 SHEE! Aa-131 r'

()\\.

i SENSING ELEMENT:

AH-735-FS AR-401-Rev. 19 Page 15

ENCLOSURE'l f

(Page 14-of 183) i].f-PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02

!CNTRL COMPLEX AIR FLOW LOW-EVENT POINT 0442 g

INDICATED' CONDITION o AHF-16A CONTROL HANDl" IN NORMAL AFTER START, AND DIFFERENTIAL PRESSURE ACROSS AHHE-10A IS <0.u63"H,0 AS SENSED BY AH-123-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o -AHF-16A TRIPPED o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE THE CAUSE OF ALARM o CHECK FOR FIRE DAMPER OPERATION o START AHF-16B TO SUPPLY SWITCHGEAR ROOMS DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FIRE DAMPER-ACTUATION, CHECK FIRE DAMPER POSITION,

REFERENCES:

DRAWING 208-005 SHEET-AH-058, DRAWING 308846 (m)_

SENSING ELEMENT: AH-123-DPS

.r

'AR-401-Rev. 15 Pagr 16 e

F-

-ENCLOSURE 1 i(

l

-(Page 15 of 183) l PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02

~

CNTRL COMPLEX AIR FLOW' LOW EVENT POINT 044G f

INDICATED CONDITION:

,=

o AHF-16B CONTROL HANDLE IN NORMAL AFTER START, AND DIFFERENTIAL PRESSURE ACROSS AHHE-10B IS <0.050"H,0 AS SLh' SED BY AH-124-DPS h_q.

- -- - 2,.

REDUNDANT INDICATION WHICH.WILL VERIFY ALARM:

o AHF-16B TRIPPED o FIRE DAMPER ALERTS OPERATOR ACTIONS-FOR A VALID ALARM:

o INVESTICATF THE CAUSE OF ALARM o CHECK FOR FIRE DAMPER OPERATION o START AHF-16A TO SUPPLY SWITCHGEAR ROOMS DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FIRE DAMPER ACTUrTION, CHECK FIRE

-DAMPER POSITION.

REFERENCES:

DRAWING 208-005 SHEET'AH-059, DRAWING 308846

,.T 7)

(

SENSING ELEMENT: AH-124-DPS

-AR-401-Rev. 19 Page 17 I.-

ENCLOSURE-1

. (

(Page 16 of 183)

PSA ANNUNCIATOR-RESPONSE PSA-X-01-02 r 01-02 CNTRL COMPLEX AIR FLOW LOW b

I EVENT POINT 0468 INDICATED CONDITION:

o AHF-17A, OR AHF-18A CONTROL HANDLE IN NORMAL AFTER START AND A LOW FLOW CONDITION EXISTS' IN DUCT WORK OF <0.15"H,0 AS SENSED BY AH-34-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOW FLOW INDICATION ON AH-32-FIR o POSSIBLE FAN TRIP ALARMS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE THE CAUSE OF ALARM o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FLOW BLOCKAGE.

ALTERNATING VENTILATION EQUIPMENT SHOULD CORRECT THE CONDITION.

A

REFERENCES:

DRAWING 208-005 SHEET AH-080, DRAWING 308847 i l SENSING ELEMENT: AH-34-DPS AR-401 Rev. 19 Page 18

~

i ENCLOSURE 1

]

73

).

(Page 17 of 183)

-j PSA ANNUNCIATOR RESPONSE-

-PSA-X-01-02 F-01-02 J

CNTRL COMPLEX AIR FLOW LOW d

EVENT POINT 0480 INDICATED CONDITION:

o -AHF-19A CONTROL HANDLE IN. NORMAL AFTER START AND A LOW FLOW CONDITION EXISTS IN DUCT WORK OF <0.10" H,0 AS SENSED BY AH-176-DPS

(

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:

o INVfrTICATE THE CAUSE OF ALARM o CHECK FOR TRIPPED FIRE DAMPERS o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FIRE DAMPER AGUATION.

IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE

CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED.

REFERENCES:

. DRAWING 208-005 SHEET AH-086, DRAWING 308847 f~s

()

SENSING ELEMENT: AH-176-DPS AR-401' Rev. 19 Page 19

ERCLOSURFJ 7-sc

. (Page 18 of 183)

-f

).

PSA ANNUNCIATOR RESPONSE-PSA-X-01-02' F-01 CNTRL COMPLEX AIR FLOW LOW EVENT POINT 0486 INDICATED CONDITION:

o AHF-20A CONTROL HANDLE'IN NORMAL AFTER START AND A LOW FLOW CONDITION EXISTS IN DUCT WORK OF <0.08"H,0 AS SENSED BY AH-36-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

r s

o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR TRIPPED FIRE DAMPERS o. ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FIRE DAMPER ACTUATION.

IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED.

THIS IS' AN EXPECTED ALARM WHEN AHF-20A IS BEING RUN IN SLOW SPEED.

REFERENCES:

DRAWING 208-005 SHEET AH-088, DRAWING 308847

~

SENSING ELEMENT: -AH-36-DPS AR-401--

Rev. 19 Page 20

I i

1 ENCLOSbRE 1

- r

(

Y

-(Page 19 of 183)=

i u

'1 PSA ANNUNCIATOR RESPONSE PSA-X-01-02-'

F-01-02 1

CNTRL COMPLEX AIR FLOW LOW H

EVENT POINT 1545 INDICATED CONDITION:

o AHF-178, OR AHF-188 CVTROL HANDLE IN NORMAL AFTER START-AND A LOW FLOW

-CONDITION EXISTS IN DUCT WORK OF 0.15"H,0 AS SENSED BY AH-546-DPS REDUNDANT INDICATION WHIOt WILL VERIFY ALARM:

e LOW FLOW INDICATION ON AH-32-FIR o POSSIBLE FAN TRIP ALARMS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF ALARM o ALTERNATE-VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 DISCUSSION:

THIS-CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FLOW BLOCKAGE.

ALTERNATING VENTILATION EQUIPMENT SHCULD CORRECT THE CONDITION.

REFERENCES:

DRAWING-208-005 SHEET AH-081, DRAWING 308847 SENSING ELEMENT: AH-546-DPS AR-401 Rev. 19 Page 21

l' 7

ENCLOSURE 1

-- -)

_ (Page 20 of_183)

(w/

PSA ANNUNCIATOR RESPONSE.

-PSA-X-01-02 F-01-02 i

CNTRL COMPLEX AIR FLOW LOW L

EVENT POINT 1546 i

INDICATED CONDITION:

f -

- o AHF-198 CONTROL HANDLE IN NORMAL AFTER START AND A LOW FLOW CONDITION -

EXISTS IN DUCT WORK OF <0.10"H,0 AS SENSED BY AH-547-DPS

,O

. _U REDUNDANT. INDICATION WHICH WILL VERIFY ALARM:

o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE THE CAUSE OF ALARM o CHECK FOR TRIPPED FIRE DAMPERS o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o -REFER TO OP-409 DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FIRE DAMPER ACTUATION.

IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED.

REFERENCES:

DRAWING 208-005 SHEET AH-086, DRAWING 308847 SENSING ELEMENT: AH-547-DPS AR-401 Rev. 19 Page 22

1..

t-ENCLOSURE 1

)

[y]

i (Page :!1 of 183)

_PSA ANNUNCIATOR RESPONSE PSA-X-01-02 F-01-02 -'

I CNTRL COMPLEX AIR FLOW LOW EVENT POINT 1547-INDICATED CONDITION:

4 o AHF-208 CONTROL HANDLE -1N NORMAL AFTER START AND A LOW FLOW CONDITION 2XISTS IN DUCT WORK OF <0.08"H,0 AS SENSED BY AH-548-DPS t

REDUNDANT INDICATION WHICH WItL VERIFY ALARM:

o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALERTS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF ALARM o CHECK FOR TRIPPED FIRE DAMPERS o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FIRE DAMPER ACTUATION.

IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE

. CONDITION THERE IS PROBABLY-A FIRE DAMPER TRIPPED.

THIS IS AN-EXPECTED ALARM WHEN AHF-20B IS BEING RUN IN SLOW SPEED.

REFERENCES:

DRAWING 208-005 SHEET AH-089, DRAWING 308847-

f/%

'., j -

SENSING ELEMENT: AH-548-DPS AR-401 Rev. 19 Page 23

=

ENCLOSURE'1

~ f~h (Page 22 of.183)

Q PSA ANNUNCIATOR RESPONSE-PSA-X-01-03 F-01,

AH FLTR 4A/B.

PRESS HIGH EVENT FOINT 0476 INDICATED' CONDITION:

o: A HIGH DIFFERENTIAL PRESSURE EXISTS ACROSS AHFL-4A 0F >5.20"H,0 AS SENSED BY AH-205-DPS REDUNDANT INDICATION WHICH WILL SERIFY ALARM:

. DIFFERENTIAL PRESSURE INDICATOR Ali-205-DPIl ON REAR OF MCB o

o POSSIBLE FAN TRIP ALARMS' o FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:

o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALARM o REFER TO OP-409 DISCUSSION:

'. THIS CONDITION MAY BE THE RESULT OF A FAN TRIP, OR A FIRE DAMPER ACTUATION. 'IF ALTERNATING VENTILATION EQUIPMENT DOES NOT CORRECT THE CONDITION THERE--IS PROBABLY A FIRE DAMPER TRIPPED.

REFERENCES:

DRAWING 208-005 SHEET AH-131, DRAWING 308847 SENSING ELEMENT:.AH-205-DPS t-AR-401 Rev. 19 Page 24

.. ~.... - - - - - - - -

~

j m

1 ENCLOSURE 1

(]j

[

(Page 23 of 183).

]

PSA'ANNUNCIATCR RESPONSE

'PSA-X-01-03 F-01-03 4

l AH FLTR 4A/B

- l

' PRESS-HIGH:

EVENT POINT 0477 a

INDICATED CONDITION:

o A HIGH DIFFERENTIAL. PRESSURE EXISTS ACROSS AHFL-4B 0F >5.20"H,0 AS SENSED BY=AH;206-DPS-.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o' DIFFERENTIAL'PRESSUREINDICATORAh206-DPIlONREAROFMCB 1'

o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER-ALARMS OPERATOR-ACTIONS FOR A VALID ALARM:

o ALTERNATE VENTILATION EQUIPMENT TO CLEAR ALAR" o -REFER =TO OP-409 DISCUSSION:

,THIS CONCITION.MAY. BE THE RESULT OF A. FAN TRIP, OR A ' FIRE DAMPER ACTUATION. : IF ALTERNATING VENTILATION EQUIPMENT DOES-NOT CORRECT THE

. CONDITION THERE IS PROBABLY A FIRE DAMPER TRIPPED.

I,-..

REFERENCES:

IDRAWING 208-005 SHEET AH-131, DRAWING 3088'47 SENSING ELEMENT: LAH-206-DPS.

-AR;401'

^

Rev.-19 Page 25-

.g in

.x..

i ENCLOSUP.E 1 z-s

(

)

(Page 24 of 183) v PSA ANNUNCIATOR RESPONSE PSA-X-01-04 F-01-04 m

CNTRL COMPLEX

')UCT TEMP HIGH EVENT POINT 0469 INDICATED CONDITION:

o h?".H TEMPERATURE OF >I35'F EXISTS IN THE CONTROL COMPLEX SUPPLY DUCT AS SENSED BY AH-207-TS, REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE HICH TEMPERATURE ALARM o REFER TO OP-409 o REFER TO AP-880 DISCUSSION:

d THIS CONDITION MAY BE THE RESULT OF A FIRE IN THE DUCT.

IF SO A FIRE DAMPER ACTUATION IS AN INDICATION OF A VALID ALARM.

REFERENCES:

DRAWING 208-005 SHEET AH-080, DRAWING 308847

[v}

SENSING ELEMENT: AH 207-TS AR-401 Rev. 19 Page 26

l i

l ENCLOSURE 1 (Page 25 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-04 F-01-04 t

CNTRL COMPLEX DUCT TEMP HIGH EVENT POINT 0487 INDICATED CONDITION:

0 :

o HIGH TEMPERATURE OF >135T EXISTS IN THE DISCHARGE OF AHF-20A DUCT AS SENi,ED BY AH-258-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALARMS OPERATOR ACTIONS. FOR A VALID ALARM:

o INVESTIGATE HIGH TEMPERATURE ALARM o REFER TO OP-409 o REFER TO AP-880 '

DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FIRE IN THE DUCT, IF SO A FIRE

' - DAMPER ACTUATION IS AN INDICATION OF A VALID ALARM.

REFERENCES:

DRAWING 208-005 SHEET AH-088. DRAWING 308847 SENSING ELEMENT: AH-258-TS AR-401 Rev. 19' Page 27

. ~.. -

i l

ENCLOSURE 1 q)

(Page 26 of 183)

-PSA ANNUNCIATOR RESPONSE PSA-X-01-04 F-01-04 l

.l CNTRL COMPLEX DUCT TEMP HIGH EVENT POINT 0517 INDICATED CONDITION:

o-HIGH TEMPERATURE EXISTS OF $135T IN THE DISCHARGE OF AHF-208 DUCT AS SENSED BY AH-543-TS' REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o POSSIBLE FAN TRIP ALARMS o FIRE DAMPER ALARMS OPERATOR ACTIONS FOR A VALID ALARM o INVESTICATE IIIGH TEMPERATURE ALARM i -

o REFER TO OP-409 o REFER TO AP-880 DISCUSSION:

THIS CONDITION MAY BE THE RESULT OF A FIRE IN-THE DUCT.

IF SO A FIRE DAMPER ACTUATION IS AN INDICATION OF A VALID ALARM.

REFERENCES:

. DRAWING 208-005 SHEET AH-089 DRAWING 308847 SENSING ELEMENT: AH-543-TS

.AR-401-Rev.-19 Page 28

ENCLOSURE 1 (Page 27 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-04 F-01-04 CNTRL COMPLEX DUCT TEMP HIGH EVENT POINT 0493 INDICATED CONDITION:

o HIGH TEMPERATURE OF >135T EXISTS IN THE CONTROL COMPLEX RETURN DUCT ON ELEVATION 124' AS SENSED BY AH-191-TS REDUNDANT INDICATION WHICH.WILL VERIFY ALARM:

o POSSIBLE LOW AIR FLOW ALARMS o FIRE DAMPERS FD-28, AND FD-29 ACTUATE OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE HICH TEMPERATURE ALARM o REFER TO OP-409 o REFER TO AP-880 DISCUSSION:

_THIS CONDITION MAY BE THE RESULT OF A FIRE IN THE DUCT.

IF SO A FIRE DAMPER ACTUATION IS AN INDICATION OF A VALID ALARM.

REFERENCES:

- DRAWING 208-005 SHEET AH-101, DRAWING 308847 SENSING ELEMENT: AH-191-TS

-AR-401 Rev. 19 Page 29-

_=~.. -.. -

"CM?/31J

(' ',b M. it e s \\;

... p PSA ANNUNCIATOR RESPLs5E P5A-X '] Q is{'4 CNTRL COMPLEX UJST AIR PRESS LOW 9

4 EVENT POINT 1690 INDICATED CONDITION:

o AIR PRESSURE IN THE RECEIVER OF AHP-1A/1B AS SENSED BY AH ~,07-PS IS

<55 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL PRESSURE INDICATOR AH-896C-PI ON JOHNSON CONTROL PANEL 25A OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE THAT AHP-1A/1B ARE RUNNING o VERIFY SAV-406 AND SAV-405 (CC STATION A7R SUPPLY VALVES) OPEN o DEENERGIZE AH-W?-SV (CC CONTROL AIR SUPPLY VALVE) o ENERGIZE AH-515 '

(CC CONTROL AIR SUPPLY VALVE)

DISCUSSION:-

THIS CONDITION MAY RESULT IN THE LOSS OF CONTROL AIR.TO CONTROL COMPLEX VENTIL*TTCN SYSTEM "A" COMPONENTS AND A LOSS OF "A" SYSTEM AIR TO "AB" SYSTEM (MPONENTS.

REFERENCES:

DRAWING 208-005 SHEET AH-148

.fm();

SENSING ELEMENT: AH-507-PS

.AR-401-Rev. 19 Page 30

~. -.. -

f3 CLOSURE 1 (Page 29 of 183)-

PSA ANNUNCIATOR RESPONSE PSA-X-01 F-01.

CNTRL COMPLEX INST AIR PRESS i

LOW EVENT POINT 1691 INDICATED CONDITION:

o AIR PRESSURE IN THE RECEIVER OF AHP-1C/1D AS SENSED BY AH-509-PS IS <55 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALA%:

LOCALPRESSUREINDICATORAH-894C-hkON.10HNSONCONTROLPANEL258 o

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE THAT AHP-IC/1D ARE RUNNING o VERIFY SAV-406 AND SAV-405 (CC STATION AIR SUPPLY VALVES) OPEN o DEENERCIZE AH-517-SV (CC CONTROL AIR SUPPLY VALVE) 1 o ENERGIZE AH-$18-SV-(CC CONTROL AIR SUPPLY VALVE)

DISCUSS.ON:

THIS CONDITION MAY RESULT IN THE LOSS OF CONROL AIR TO CONTROL COMPLEX VENTILATION SYSTEM "B" COMPONENTS AND A LOSS OF "B" SYSTEM AIR TO "AB" SYSTEM COMPONENTS.

REFERENCES:

- DRAWING 208-005 SHEET AH-149 SENSIim ELEMENT:.AH-509-PS AR-401.

Rev, 19 Page 31 i

ENCLO5URE 1 (Page 30 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-05 F-01-05 i

CNTRL COMPLEX INST AIR PRESS LOW EVENT POINT 1692 lINDICATEDCONDITION:

o REGULATED "A" SIDE CONTROL AIR AS SENSED BY AH-512-PS IS <17 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOCAL PRESSURE INDICATOR AH-8968-P" ON JOHNSON CONTROL PANEL 25A o

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE THAT AHP-1A/1B ARE RUNNING o VERIFY SAV-406 AND SAV-405 (CC STATION AIR SUPPLY VALVES) OPEN o DEENERGIZE AH-517-SV (CC CONTROL AIR SUPPLY VALVE) o ENERGIZE AH-518-SV (CC CONTROL AIR SUPPLY VALVE) i DISCUSSION:

THIS CONDITION MAY RESULT IN THE LOSS OF CONTROL AIR TO CONTROL COMPLEX

. VENTILATION SYSTEM "A" COMPONENTS AND A LOSS OF "A" SYSTEM AIR TO "AB" SYSTEM COMPONENTS.

REFERENCES:

DRAWING 208-005 SHEET AH-150 SENSING ELEMENT: AH-512-PS AR-401 Rev. 19 Page 32

l a

w ENCLOSURE 1 j

(Fage 31 of 183)

/

PSA ANNUNCIATOR RESPONSE PSA-X-01-05 F-01-05 i

I CNTRL COMPLEX INST AIR PRESS LOW EVENT POINT 1693 INDICATED CONDITION:

o AIR PRESSURE FOR DAMPER CONTROL AS SENSED BY AH-513-PS IS <17 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOCAL PRESSURE INDICATOR AH-8958-PI ON JOHNSON CONTROL PANEL 25AB o

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE THAT AHP-1A/IB ARE RUNNING o VERIFY SAV-406 AND SAV-405 (CC STATION AIR SUPPLY VALVES) OPEN o DEENERCI7E AH-517-SV (CC CONTROL AIR SUPPLY VALVE) o ENERCIZE AH-518-SV (CC CONTROL AIR SUPPLY VALVE) 4 DISCUSSION:

THIS CONDITION MAY RESULT IN THE LOSS OF CONTROL AIR TO CONTROL COMPLEX VENTILATION SYSTEM COMPONENTS

REFERENCES:

DRAWING 208-005 SHEET AH-150 I

SENSING ELEMENT: AH-513-PS AR-401-Rev. 19 Page 33

. -.. ~. -

j i

ENCLOSURE 1 p

(Page 32 of 183)

(

f PSA ANNUNCIATOR RESPONSE PSA-X-01-05 F-01-05 i

t l

CNTRL COMPLEX INST AIR PRESS LOW EVENT POINT 1694 INDICATED CONDITION:

o REGULATED "B" SIDE CONTROL AIR AS SENSED BY AH-514-PS IS <17 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOCAL PRESSURE INDICATOR AH-894B-Pk ON JOHNSON CONTROL PANEL 258 o

OPERATOR ACTIONS FOR A VALID ALARM o ENSURE THAT AHP-1C/1D ARE RUNNING o VERIFY SAV-406 AND SAV-405 (CC STATION AIR SUPPLY VALVES) OPEN o DEENERGIZE AH-518-SV (CC CONTROL AIR SUPPLY VALVE) o ENERGIZE AH-517-SV (CC CONTROL AIR SUPPLY VALVE)

DISCUSSION:

THIS CONDITION MAY RESULT IN THE LOSS OF CONTROL AIR TO CONTROL COMPLEX VENTILATION SYSTEM "B" COMPONENTS AND A LOSS OF "B" SYSTEM AIR TO "AB"

$YS1EM COMPONENTS.

REFERENCES:

DRAWING 208-005 SHEET-AH-150 SENSING ELEMENT: AH-514-PS AR-401 Rev. 19 Page 34

ENCLOSURE 1

(~Q}

(Page 33 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-06 F-01-06 CNTRL COMPLEX AIR DRYER TEMP HIGH EVENT POINT 1695 INDICATED CONDITION:

o AIR TEMPERATURE ON THE OUTLET OF AHDR-1A 15 >45T AS SENSED BY AH-510-T5 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY MECH SUPERVISOR IN CHARGE OF HVAC TO INSPECT AHDR-1A FOR PROPER OPERATION DISCUSSION:

AHDR-1A 15 REFRIGERATED AIR DRYER WHICH UTILIZE 5 A REFRIGERANT CYCLE TO DRY CONTROL COMPLEX CONTROL AIR SUPPLY, HIGH AIR TEMPS CAN BE CAUSED BY LOW REFRIGERANT CHARGE OR A DIRTY CONDENSER COIL.

REFERENCES:

ORAWING 208-005 SHEET AH-150 hk SENSING ELEMENT: AH-510-T5

- x)

AR-401 Rev. 19

-Page 35

ENCLOSURE 1 r~(

(Page 34 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-06 F-01-06 CNTRL COMPLEX AIR DRYER TEMP HIGH EVENT POINT 1696 INDICATED CONDITION:

f o AIR TEMPERATURE ON THE OUTLET OF AHDR-1B IS >45T AS SENSED BY AH-511-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY MECH SUPERVISOR IN CHARGE OF HVAC TO INSPECT AHDR-1B FOR PROPER OPERATION DISCUSSION:

AHDR-1B IS REFRIGERATED AIR DRYER WHICH UTILIZES A REFRIGERANT CYCLE TO DRY CONTROL COMPLEX CONTROL AIR SUPPLY HIGH AIR TEMPS CAN BE CAUSED BY LOW REFRIGERANT CHARGE OR A DIRTY CONDENSER COIL.

REFERENCES:

DRAWING 208-005 SHEET AH-150 SENSING ELEMENT: AH-511-TS AR-401 Rev. 19 Page 36

ENCLOSURE 1 O

(Page 35 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-02-07 F-01-07 i

CHILLED WATER SYSTEM TROUBLE

'n EVENT POINT 0518 INDICATED CONDITION:

o CHP-1A MOTOR IS N01 ENERGIZED WITH THE CONTROL HANDLE IN THE NORMAL AFTER START POSITION

-t REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

GREEN LIGHT ON WITH A RED FLAG ON'THE CHP-1A CONTROL STATION o

o RUNNING CHILLER TRIPS ON LOW CHILLED WATER FLOW OPERATOR ACTIONS FOR A VALID ALARM:

o START CHP-1B AND CHHE-1B PER OP-409 DISCUSSION:

?

REFERENCES:

DRAWING 208-076 SHEET CH-03 C

SENSING ELEMENT:

42/5CR AR-401' Rev. 19 Page 37

1 5

ENCLOSURE 1 m

(Page 36 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 0519 INDICATED CONDITION:

o CHP-18 MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

GREENLIGHTONWITHAREDFLAGON'iHECHP-1BCONTROLSTATION o

o RUNNING CHILLER TRIPPED ON LOW CHILLED WATER FLOW OPERATOR ACTIONS FOR A VALID ALARM:

o START CHP-1A AND CHHE-1A PER OP-409 DISCUSSION:

RETERENCES: DRAWING 208-076 SHEET CH-04 SENSING ELEMENT: C5/5C. CS/0, 428 RELAY

'AR-401 Rev,'19 Page 38

LNCLOSUREJ p

(Page 37 of 183) g_

PSA ANNUNCIATOR REOPONSE P5A-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 0520 i

INDICATED CONDITION:

J :

o CHHE-1A BREAKER IS OPEN WITH CONTROL HANDLE IN THE NORMAL AFTE'l START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

CREENLIGHTONWITHAREDFLACON2HHE-1ACONTROLSTATION o

OPERATOR ACTIONS FOR A VALID ALARM:

o HAVE BREAKER CUBICLE CHECKED FOR DROPPED TARGETS o SWAP CHILLERS PER OP-409 DISCUSSION:-

AN ES BUS UNDERVOLTAGE CONDITION WILL CAUSE THIS CONDITION, THE BREAKER WILL NOT~BE ABLE TO BE RECLOSED UNTIL THE UNDERVOLTAGE LOCK OUT HAS BEEN

RESET,

REFERENCES:

DRAWING 208-076 5HEET CH-01 1

SENSING' ELEMENT:

CS/SC, CS/0, R/B CONTACT

'AR-40i Rev. 19 Page 39 i

P

. ms LNCLOSURE 1

.(

(Page 38 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 1.

l CHILLED WATER t

8YSTEM TROUBLE t

i EVENT POINT 0521 INDICATED CONDITION:

o-CHHE-1B BREAKER IS OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION

(

REDUNDART INDICATION WHICH WILL VERIFY ALARM:

GREENLIGHTONWITHAREDFLAGONEHHE-1BCONTROLSTATION o

OPERATOR ACTIONS FOR A VALID ALAP.M:

o HAVE BREAKER CUBICLE CHECKED FOR DROPPED TARGETS o SWAP CHILLERS PER OP-409 J

DISCUSSION:

AN ES BUS UNDERVOLTAGE CONDITION WILL CAUSE THIS CONDITION, THE BREAKER WILL NOT BE ABLE TO BE RECLOSED UNTIL THE UNDERVOLTAGE LOCK OUT HAS BEEN

-RESET, l

REFERENCES:

DRAWING 208-076 SHEET CH-02 i

SENSING ELEMENT:

CS/SC, CS/0, R/B CONTACT AR-401-Rev. 19 Page 40

ENCLOSURE 1 (Page 39 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 3

CHILLED WATER SYSTEM TROUBLE EVENT POINT 1526 P

INDICATED COND[ TION:

o CHT-1 LEVEL IS 2 180' 2",

OR z 12" BELOW CENTER LINE OF TANK REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL LEVEL INDICATOR ON CHT-1 OPERATOR ACTIONS FOR A VALID ALARM:

o CONTACT CHEMISTRY AND REFILL CHT-1 REFER TO OP-409 DISCUSSION:

1

REFERENCES:

DRAWING 208-076 SHEET CH-06

}

SENSING ELEMENT: CH-660-LSS AR-401' Rev. 19 Page 41

n ENCLOSURE 1

(

(Page 40 of 183)

-l PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE EVENT POINT 1554 INDICATED CONDITION:

o CHHE-1A BREAKER HAS NO DC CONTROL POWER i

REDdNDANT INDICATION WHICH WILL VERIFY ALARM:

o NO INDICATING LIGHTS ON CHHE-1A C6NTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY " PULL OUT" FUSE BLOCK FOR CHHE-1A BREAKER IS INSTALLED o VERIFY DPDP-5A BREAKER 9 CLOSED DISCUSSION:

THIS CONDITION DISABLES REMOTE BREAKER OPERATION AND PROTECTIVE RELAYING.

REFER TO OP-703 FOR INSTRUCTIONS ON LOCAL BREAKER OPERATION.

THIS IS AN EXPECTED ALARM FOR BREAKER TAGGING OPERATIONS.

1

REFERENCES:

DRAWING 208-076 SHEET CH-01 SENSING ELEMENT:

27C RELAY I

AR-401 Rev. 19 Page 42

)

ENCLOSURE 1 (Page 41 of 183) l C,.

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 1

CHILLED WATER SYSTEM TROUBLE EVENT POINT 1555 INDICATED CONDITION:

i o CHHE-18 BREAKER HAS NO DC CONTROL POWER REDUNDANT INDICATION WHICH LkVERIFYALARM:

.NO INDICATING LIGHTS ON CHHE-1B C' NTROL STATION o

OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY PULL OUT FUSE BLOCK FOR CHHE-1B BREAKER IS INSTALLED o VERIFY DPDP-$8 BREAKER 9 CLOSED DISCUSSION:

THIS CONDITION DISABLES REMOTE BREAKER OPERATION AND PROTECTIVE RELAYING, REFER TO OP-703 FOR INSTRUCTIONS ON LOCAL BREAKER OPERATION.

THIS IS AN EXPECTED ALARM FOR BREAKER TAGGING OPERATIONS.

REFERENCES:

- DRAWING 208-076 SHEET CH-02 SENSING ELEMENT:

27C RELAY l

~

AR-401' Rev. 19 Page 43

ENCLOSURE 1 (Page 42 of 183)

F-01-07]l PSA ANNUNCIATOR RESPONSE PSA-X-01-07 CHILLED WATER SYSTEM TROUBLE i

I EVENT POINT 1556 j

INDICATED CONDITION:

o CHHE-1A MOTOR WINDING TEMPERATURE IS >105T, OR CHHE-1A OIL TEMPERATURE IS >170T.

'(

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

v LOCALCONTROLPANEL-REDINDICATOfiLIGHTISONFOR"0IL/ MOTOR

~

o TEMPERATURE" OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP CHILLERS PER OP-409 DISCUSSION:

THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON IS DEPRESSED p_

REFERENCES:

. DRAWING 208-076 SHEET CH-05 I,

SENSING ELEMENT:

6R, 2/A LAPS-401 Rev. 19 Page 44-

1 i

i ENCLOSURE 1

\\

ft (Page 43 of 183)

%)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 l

CHILLED WATER l

SYSTEM i

TROUBLE l

iiVENT POINT 1557 INDICATED CONDITIO.,:

o CHHE-1A REFRIGERANT PRESSURE IS < 11.9" HG i

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOCAL CONTROL PANEL - RED INDICATCk LIGHT IS ON FOR " LOW PRE'SSURE" o

OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP CHILLERS PER OP-409 DISCUSSION:

THIS CONDITION WILL CAUSE THE CHILLER TO TRIP. THE CONDITION SFALT IN UNTIL THE RESET PUSHBulr0N IS DEPRESSED

},_

REFERENCES:

DRAWING 208-076 SHEET CH-05

+

t SENSING ELEMENT:

7R, 2/A b.

AR-401 Rev. 19 Page 41

i ENCLOSURE 1 (Page 44 of 153)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 r

I

~

CHILLED WATER SYSTEM TROUBLE C

EVENT POINT 1558 INDICATED CONDITION:

o CHHE-1A REFRIGERANT PRESSURE IS >15 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOCALCONTROLPANEL-REDINDICATdRLIGHTISONFOR"HIGHPRESSURE" o

OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP CHILLERS PER OP-409 DISCUSSION:

THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN

.UNTIL THE RESET PUSHBUTTON IS DEPRESSED

REFERENCES:

DRAWING 208-076 SHEET CH-05

[

)

SENSING ELEMENT:

8R, 2/A

-AR-401 Rev. 19 Page 46

t ENCLOSURE 1

.f']

\\

/

(Page 45 of' 183)

PSA ANNUNCIATOR RESPONSF.

PSA-X 01-07 F-01-07 CHILLED WATER SYSTEM TROUBLE r

EVENT POINT 1559-1 INDICATED CONDITION:

o CHHF-1A OIL PRESSURE IS < 27 PSIG 4

(

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOCAL CONTROL PANEL - RED INDICAT0k LIGHT IS ON FOR " LOW OI PRESS" L

o OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP CHILLERS PER OP-409 DISCUSSION:

THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON IS DEPRESSED i

REFERENCES:

DRAWING 208-076 SHEET-CH-05 l

SENSING ELEMENT:- 9R, 2/A' AR-401-Rev. 19 Page 47'

...-.--_-,.-_..i

,s-ENCLOSURE 1 (Page 46 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 i

~

CHILLED WATER SYSTEM THOUBLE f

EVENT POINT 1560 INDICATED CONDITION:

o CHHE-1A'DOES NOT HAVE ANY POWER TO THE CONTROL PANEL OR COMPRESSOR MOTOR AS SENSED BY RELAY 14/R REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

AMBER"POWERFAILUP:"LIGHTONLO[LCONTROLPANEL o

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF POWER LOSS DISCUSSION:

REFERENCES:

DRAWING 208-076 SHEET CH-05

/*

SENSING ELEMENT:

14L, 2/A AR-401-Rev. 19

.Page 48

-,-w~

v

__=__

ENCLOSURE 1 Q.

(Page 47 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-0/

S CHILLED WATER SYSTEM TROUBLE EVENT POINT 1561 INDICATED CONDITION:

o CHHE-1B MOTOR WINDING TEMPERATURE IS >105'C, OR CHHE-18 OIL TEMPERATURE IS >170*F.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOCAL CONTROL PANEL - RED INDICAT05 LIGHT IS ON FOR "0IL/M0f0R TEMP" o

OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP CHILLERS PER OP-409 DISCUSSION:

THIS CONDITION WILL CAUSE THE' CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON IS DEPRESSED

REFERENCES:

. -DRAWING 208-076 SHEET CH-06 SENSING ELEMENTi 6R, 2/8 AR-401 Rev,'19 Page 49

i i

ENCLOSURE 1 r~N h

(Page 48 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 A

CHILLED WATER l

SYSTEM TROUBLE r

EVENT POINT 1562 INDICATED CONDITION:

>t o-.'CHHE-1B REFRICERANT PRESSURE IS <11,9" HG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOCAL CONTROL PANEL - RED INDICATO'R LIGHT IS ON FOR " LOW PRE'550RE" o

OPERATOR ACTIONS FOR A VALID ALARM:

. o SWAP CHILLERS PER OP-409 L

1 DISCUSSION:

i THIS CONDITION WILL CAUSE THE CHILLER TO TRIP, THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON IS DEPRESSED

REFERENCES:

- DRAWIC 208-076 SHEET CH-06 I

e (~

4 SENSING ELEMENT:

7R -2/8-AR-4011 Rev. 19 Page' 50'-

-i w

ENCLOSURE 1 rg (Page 49 of 183)

_'(j PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 CrilLLED 'NATER SYSTEM TR0t,BLE h

EVENT POINT 1563 INDICATED CONDITION:

I o CHHE-1B REFRIGERANT PRESSURE IS >15 PSIG REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOCALCONTROLPANEL-REDINDICATdULIGHTISONFOR"HIGnPRESSURE" o

OPERATCR ACTIONS FOR A VALID ALARM:

o SWAP CHILLERS PER OP-409 DISCUSSION:

THIS CONDITION WILL CAUSE THE CHILLER TO TRIP. THE CONDITION SEALS IN UNTIt' THE RSSET PUSHBUTTON IS DEPRESSED -

REFERENCES:

-DRAWING 208-076 SHEET CH-06

( )-

SENSING ELEMENT:

BR, 2/B AR-401' Rev. 19 Page 51

ENCLOSURE 1 p().

(Page 50 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 l

l' CHILLED WATER SYSTEM TROUBLE EVENT POINT 1564 4

INDICATED CONDITION:

o CHHE-1B OIL PRESSURE IS < 27 PSIG REDUNDANT INDICATION WHICH WILL VERIFY. ALARM:

LOCALCONTROLFANEL-REDINDICAT0lkLIGHTISONFOR"LOWOIL' PRESS" o

OPERAT0i, ACTIONS FOR A VALID ALARM:

o SWAP CHILLERS PER OP-409 DISCUSSION:

THIS CONDITION WILL CAUSE THE CHILLER TO TRIP THE CONDITION SEALS IN UNTIL THE RESET PUSHBUTTON IS DEPRESSED

REFERENCES:

DRAWING 208-076 SHEET CH-06

. -(^3 y)

SENSING ELEMENT:

9R,-2/B AR-401-Rev. 19 Page 52 l

= _.

i l

l ENCLOSURE I

(

(Page 51 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-01-07 F-01-07 i

J i

CHH.Lfo WATER SY6VEtA i

TROUBL E i

EVENT POINT 1565 t

INDICATED CONDITION:

o CHHE-1B DOES NOT HAVE ANY POWER TO THE CONTROL PANEL OR COMPRESSOR MOTOR AS SENSED BY RELAY 14/R REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

AMBER"POWERFAILURE"LIGHTONLOC'ELCONTROLPANEL o

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE THE CAUSE OF POWER LOSS g.

DISCUSSION:

REFERENCES:

DRAWING 208-076 SHEET CH-06

-r SENSING ELEMENT:

14R, 2/B-s AR-401 Rev. 19 Page 53-

l I

ENCLOSURE 1 I

)

(Page 52 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-02-01 F-02-01 I

I TOXIC GAS I

I MONITOR l

l TROUBLE l

l I

I I

EVENT POINT 0314 INDICATED CONDITION:

o ONE OR MORE OF THE FOLLOWING MONITORS' LOCAL TROUBLE ALARMS HAS ACTUATED:

AH-648-CE AH-652-CE AH-649-CE AH-653-CE REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL TROUBLE ALARMS ON AH-648-CE, AH-649-CE, AH-652-CE, OR AH-653-CE o COMPUTER POINTS S263, S297, S298, S29P FOR T0XIC GAS CONCENTRATION OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE THE CAUSE OF TROUBLE o NOTIFY I&C TO TROUBLE SHOOT MONITORS DISCUSSION:

REFERENCES:

ORAWING 208-005 SHEET AH-84 y,<

SENSING ELEMENT:

AH-648-CE, AH-652-CE, AH-649-CE, AH 653-CE AR-401 Rev. 19 Page 54

ENCLOSURE 1 f

7)

(Page 53 of 183)-

IV

-PSA ANNUNCIATOR RESPONSE PSA-X-02-01 F-02 1 I

TOXIC GAS I

I MONITOR I

I TROUBLE I

I I

I I

I EVENT POINT 0432 INDICATED CONDITION:

a.

o T0XIC CAS >5 PPM CL AS-SENSED BY AH-648-CE AND/OR AH-649-CE OR,

>2 PPM S0, SENSED BY AH-652-CE AND/OR AH-653-CE REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o COMPUTER POINTS S263, S297, 5298, OR 5299 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-513 o REFER TO SP-300 DISCUSSION:

REFERENCES:

' DRAWING 208-005 SHEET AH-84 Q

i, i

SENSING ELEMENT: AH-648-CE, AH-652-CE, AH-649-CE, AH-653-CE l

AR-401 Rev. 19 Page 55 i

I

1 1

ENCLOSURE 1 A.k,).

(Page 54 of 183)

PSA ANNUNCIATOR RESPONSE

'PSA-X-02-01 F-02-01 l

l TOXIC GAS I

I MONITOR I

I TROUBLE I

I I

I

~

l l

l EVENT POINT 0800 INDICATED CONDITION:

T0XIC GAS >20 PPM S0, SENSED DETECTORS AT UNITS 1&2 o

REDUNDANT' INDICATION WHICH WILL VERIFY ALARM:

o NOTIFICATION OF A SPILL FROM UNITS 1&2 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO AP-513 DISCUSSION:-

REFERENCES:

DRAWING 208-005 SHEET AH-84A SENSING ELEMENT:

UNITS 1 & 2 "A" OR "B" 502 DETECTOR l

1 AR 401 Rev. 19 Page 56

2.

ENCLOSURE 1

.(~'g

(,f-

.(Page 55 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-02-04 F-02-04 CISYSTEM TROUBLF EVENT POINT 1567 INDICATED CONDITION:

o THE 4I60V BREAKER FOR THE REACTOR BLDG. CHILLER IS CLOSED AND AN ALARM EXISTS ON THE MICROTECH CONTROL PANEL o LOW DIFFERENTIAL PRESSURE ACROSS CIP-1A OR CIP-1B REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o A FAULT IS INDICATED ON THE MICROTECH FLUORESCENT DISPLAY o CIP-1A OR CIP-1B TRIPS OPERATOR ACTIONS FOR A VALID ALARM:

o DEPRESS THE " UNIT STATUS" PUSHBUTTON-IF NO VISUAL DISPLAY PRESENT o DEPRESS THE " FAULT HISTORY" PUSHBUTTON ONCE TO DETERMINE THE CURRENT FAULT, AND EIGHT MORE TIMES FOR THE PREVIOUS EIGHT FAULTS IF DESIRED o CORRECT SOURCE OF THE FAULT, THEN DEPRESS " CLEAR FAULT" PUSHBUTTON AND RESTART THE CHILLER IF DESIRED, REFER TO OP-417A o IF THE CHILLER CANNOT BE RESTARTED, THEN PLACE THE SYSTEM IN THE " FREE" COOLING MODE OR SWAP TO SW COOLING FOR THE RB COOLING UNITS, REFER TO

-OP-417A o PLACE ALTERNATE CIP IN SERVICE PER OP-417A DISCUSSION:

HIGH DISCHARGE PRESSURE, WHICH IS HIGH CONDENSER PRESSURE, TRIPS THE o

HIGH MECHANICAL PRESSURE SWITCH FIRST THE SWITCH MUST BE RESET INSIDE MICROTECH, THEN CLEAR FAULT WILL ALLOW RESTART. IF THE FAULT CANNOT BE CLEARED, THEN HVAC PERSONNEL SHOULD BE NOTIFIED FOR' RESOLUTION o IF THE CHILLER IS OPERATING WHEN A CIP TRIPS, THEN THIS WILL TRIP THE CHILLER ON LOW FLOW

REFERENCES:

DRAWING 208-077 SHEET CI-25 SENSING ELEMENT: RL3-ALM, RL6-ALM, CI-772-DPS

.AR-401

.Rev. 19 Page 57

,q-ENCLOSURE _1

()

(Page 56 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-02-04 F-02-04 l

ClSYSTEM TROUBLE l

EVENT POINT 1568 INDICATED CONDITION:

f o HIGH VIBRATION ON CIF-1A OR CIF-1B o LOW TOWER BASIN WATER LEVEL

<"'N

)

REDUNDANT INDICATION WHICH WILL Ve.IFY ALARM:

o CIF-1A OR CIF-18 HAS TRIPPED o CIP-1A OR CIP-1B MAY TRIP ON LOW DP, MAY EXHIBIT CAVITATION, OR MAY CAUSE A TRIP OF THE RB CHILLER ON LOW FLOW OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY HVAC PERSONNEL FOR TRIPPED FAN ON HIGH VIBRATION o VERIFY PROPER VALVE ALIGNMENT FOR LOW BASIN LEVEL o SECURE PUMP IF CAVITATION EXISTS AND ESTABLISH SW COOLING TO THE RB UNTIL PROBLEM IS CORRECTED o ENSURE PROPER 00 TANK LEVEL DISCUSSION:

i o THE BASIN WATER LEVEL IS AUTOMATICALLY MAINTAINED WITH TWO FLOAT VALVES OPERATING IN PARALLEL TO SUPPLY EACH TOWER, THE TOWER BASINS ARE CROSSTIED SUCH THAT EITHER VALVE WILL SUPPLY BOTH BASINS. LOW BASIN LEVEL DISABLES THE BASIN WATER HEATERS.

o DO SYSTEM SUPPLIES MAKEUP TO THE IB ROOF AND SOUTH BERM COOLING TOWER

REFERENCES:

DRAWING 208-077 CI-29 AND CI-30 p.

)

SENSING ELEMENT:

CI-784-SS, CI-785-SS, CI-780-LS, CI-781-LS AR-401 Rev. 19 Page 58

)

ENCLOSURE 1

/'}

-(Page 57 of 183) j f

PSA ANNUNCIATOR RESPONSE PSA-X-02-05 F-02-05 Cl CIRC PP 1A/B OVERLOAD EVENT POINT 1879 INDICATED CONDITION:-

  • i o CIP-1A OR CIP.-1B MOTOR CURRENT IS EXCESSIVE

)

REDUNDANT INDICATION WHICH,WILL VERIFY ALARM:

PUMPMAYTRIPFROMLOWDPA5ARE55LTOFLOCKEDROTORORVERYHIGH o

FLOWRATES OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE OPERATION OF CIP-1A OR CIP-1B o SWAP RB COOLING TO SW IF REQUIRED DISCUSSION:

REFERENCES:

DRAWING 208-077 CI-27 AND CI-28' SENSING ELEMENT: OVERLOAD HEATERS IN INST COMPARTMENT IN UNIT 480V SG RM AR-401 Rev. 19 Page 59

.u

ENCLOSURE 1

[

(Page 58 of 183)

\\#

PSA ANNUNCIATOR RESPONSE P5A-X-02-06 F-02-06 l

i.

Cl CIRC PUMP 2A/B 3A/S TRIP EVENT POINT 0524 INDICATED CONDITION:

o CIP-2A BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION t

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o -CREEN LIGHT ON WITH A RED FLAG ON CIP-2A CONTROL STATION OPERATOR' ACTIONS FOR A VALID ALARM:

o START CIP-28 o HAVE BREAKER CUBICLE CHECKED FOR DROPPED TARGETS DISCUSSION:

r

REFERENCES:

DRAWING 208-077.- SHEET CI-03 i

SENSING ELEMENT:

CS/SC, C5/0, R/B i

AR-401-Rev. 19 Page 60 l

1 ENCLOSURE 1 (Page 59 of--183)'

PSA ANNUNCIATOR RESPONSE PSA-X-02-06 F-02-06 Cl CIRC PUMP.

2A/B 3A/B TRIP t

EVENT POINT 0526 l

INDICATED CONDITION:

o CIP-2B BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION l>

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

~

o GREEN LIGHT ON WITH A RED FLAG ON CIP-2B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o START CIP-2A o-HAVE BREAKER CUBICLE CHECKED FOR DROPPED TARGETS DISCUSSION:

REFERENCES:

DRAWING 208-077 SHEET CI-04

,y

'(

SENSING ELEMENT: CS/SC, CS/0, R/S AR-401-Rev, 19 Page 61

l

,q.

ENCLOSURE l'

. -(J

)

(Page 60 of 183)

PSA' ANNUNCIATOR RESPONSE PSA-X-02 F-02-06 Cl CIRC PUMP:

2A/B 3A/B TRIP EVENT POINT 0528 INDICATED CONDITION:

o CIP-3A CONTROL-HANDLE IN NORMAL AFTER START POSITION WITH THE MOTOR NOT ENERGIZED

-p t

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON CIP-3A CONTROL STATION OPERATOR ACTION 5 FOR A VALID ALARM:

o SWAP REACTOR CAVITY COOLING TO "B" SIDE PER OP-417 o - MONITOR REACTOR CAVITY TEMPS ON AH-1003-TIR PER OP-409 DISCUSSIO4:

i A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE-NUCLEAR INSTRUMENTATION.

REFFRENCES:

DRAWING 208-077 SHEET CI-18

- (

SENSING ELEMENT:42/13CR 4

1 4

.AR-401 Rev. 19 Page 62

.-p EN_ CLOSURE 1.

.i (Page 61 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-02-06 F-02-06 Cl CIRC PUMP 2A/B 3A/B TRIP EVENT POINT 0529 INDICATED CONDITION:

a o CIP-3B CONTROL HANDLE IN NORMAL AFTER START POSITION WITH THE MOTOR NOT ENERGIZED REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON CIP-3B CONTROL STATION OPEP.ATOR ACTIONS FOR A VALID ALARM:

o SWAP REACTOR CAVITY COOLING TO "A" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPS ON AH-1003-TIR PER OP-409 DISCUSSION:

A SUSTAINED LOSS OF COOLING TO THE REACTOR-CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE-NUCLEAR INSTRUMENTATION.

REFERENCES:

DRAWING 208-077 SHEET CI-19

()'

SENSING ELEMENT: 'CS/SC, CS/0,'42B AR-401 Rev.-.19 Page 63

ENCLOSURE 1

(

(Page_62 of 183)

-PSA ANNUNCIATOR-RESPONSE PSA-X-02-07 F-02 -

Cl CIRC Pl!MP 2A/B OVERLOAD EVENT POINT 0525 INDICATED CO*JDITION:

o CIP-2A MOTOR AMPS >115% RATED LOAD REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HICH LOCAL TEMPERATURES ON PUMP AND OR MOTOR OPERATOR ACTIONS FOR A VALID ALARM:

o SHUTDOWN CIP-2A AND START CIP-28 o INVESTIGATE THE OPERATION OF THE PUMP MOTOR TO DETERMINE THE CAUSE OF THE ALARM DISCUSSION:

THIS ALARM INDICATES THAT THE INTERNAL-OVERCURRENT-DEVICE HAS ACTUATED AND THAT THE MOTOR MAY TRIP AT ANY TIME..

REFERENCES:

DRAWING 208-077 SHEET CI-03 SENSING ELEMENT: 49X THERMAL OVERLOADS IN MCC AR-401.

Rev. 19 Page 64

ENCLOSURE 1 W

.(

(Page 63 of 183T PSA ANNUNCIATOR RESPONSE

-PSA-X-02-07 F-02,

Cl CIRC PUMP 2A/B OVERLOAD f

EVENT POINT 0527 INDICATED CONDITION:

o CIP-28 MOTOR AMPS >115% RATED LOAD

(

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

HIGHLOCALTEMPERATURESONPUMPANi5ORMOTOR o

OPERATOR ACTIONS FOR A VALID' ALARM:

o.

SHU1DOWN CIP-28 AND START CIP-2A o INVESTICATE THE OPERATION OF THE PUMP MOTOR TO DETERMINE THE CAUSE OF THE ALARM DISCUSSION:

THIS ALARM INDICATES.THAT THE INTERNAL OVERCURRENT DEVICE HAS ACTUATED AND THAT THE MOTOR MAY TRIP AT ANY TIME.-

REFERENCES:

DRAWING 208-077 SHEET CI-04

. SENSING ELEMENT: 49X THERMAL OVERLOADS IN MCC AR-401-Rev. 19 Page 65

~

?

1 :y)--

ENCLOSURE.1 (Page 64 of 183)

V-PSA ANNUNCIATOR RESPONSE-PSA-X-02 F-02-08 Cl PUMP SUCT PRESS LOW EVENT POINT 1702 INDICATED CONDITION:

o CIP-2A BREAKER IS CLOSED AND SUCTION PRESSURE IS < 5-PSIG AS SENSED BY

'CI-728-PS

(

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOW LOCAL PRESSURES ON PUMP SUCTION GAUGE CI-99-PI OPERATOR ACTIONS FOR A VALIO ALARM:

o CHECK CIT-1 LEVEL o INVESTICATE THE CAUSE OF LOW SUCTION PRESSURE o VERIFY PROPER OPERATION OF THE REACTOR BLDG CHILLER DISCUSSION:

THIS CONDITION COULD BE CAUSED BY A LOW LEVEL IN ~THE EXPANSION TANK, OR BY EXCESSIVE PRESSURE DROP ACROSS CIHE-3/CIHE-4A OR THE LEAK RATE TEST COOLER. THE LINE UP OF THE SYSTEM SH0ulD BE VERIFIED.

i

REFERENCES:

DRAWING 208-077 SHEET CI-03 l(j' SENSING ELEMENT:

CI-728-PS, R/A l

AR-401 Res. 19 Page 66 l

l'

1.

ENCLOStBE_1 m

[G

')

(Page 65 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-02-08 F-02-08 Cl PUMP SUCT PRESS LOW EVENT POINT 1703 INDICATED CONDITION:

o CIP-28 BREAKER IS CLOSED AND SUCTION PRESSURE IS < S PSIG AS SENSED BY CI-729-PS (3)

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

t LOWLOCALPRESSURESONPUMPSUCTIdkGAUGECI-101-PI o

OPERATOR ACTIONS FOR A VALID ALARM:

o CHECK CIT-1 LEVEL o INVESTIGATE THE CAUSE OF LOW SUCTION PRESSURE o VERIFY PROPER OPERATION OF THE REACTOR BLDG CHILLER DISCUSSION:

THIS CONDITION COULD BE CAUSED BY A LOW LEVEL IN THE EXPANSION TANK, OR BY EXCESSIVE PRESSURE DROP ACROSS CIHE-3/CIHE-4A OR THE LEAK RATE TEST

COOLER, THE LINE UP OF THE SYSTEM SHOULD BE VERIFIED.

REFERENCES:

DRAWING 208-077 SHEET CI-04 x, )

SENSING ELEMENT: CI-729-PS, R/A AR-401 Rev. 19 Page 67

ENCLOSURE 1

(^N!

!().

(Page 66 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-02-08 F-02-08 i

Cl PUMP '

SUCT PRESS LOW w

EVENT POINT 1704 INDICATED CONDITION:

o CIP-3A CONTROL SWITCH IS IN NORMAL AFTER START, AND SUCTION PRESSURE IS

< 45 PSIG AS. SENSED BY CI-730-PS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

LOW LOCAL PRESSURES ON PUMP SUCTIbN GAUCE CI-732-PI o

OPERATOR ACTIONS FOR A VALID ALARM:

o CHECK CIT-1 LEVEL o INVESTIGATE THE CAUSE OF LOW SUCTION PRESSURE o MONITOR REACTOR CAVITY TEMPERATURES ON AH-1003-TIR PER OP-409 o CHECK CIP-2A/2B DISCHARGE PRESSURE DISCUSSION:

THIS CONDITION COULD BE CAUSED BY A LOW LEVEL IN THE EXPANSION TANK, OR BY EXCESSIVE FLOWRATE. THE LINE UP OF THE SYSTEM SHOULD BE VERIFIED.

A SUSTAINED LOSS _0F COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE

-- EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.

O

REFERENCES:

. DRAWING 208-077 SHEET CI-18 SENSING ELEMENT:

CI-730-PS AR-401 Rev. 19 Page 68

I ENCLOSURE 1 h(s (Page 67 of 183)

~ PSA ANNUNCIATOR RESPONSE PSA-X-02-08 F-02-08

~

Cl PUMP SUCT PRESS LOW I

EVENT POINT 1705 INDICATED CONDITION:

o CIP-3B CONTROL SWITCH IS IN NORMAL AFTER START, AND SUCTION PRESSURE IS

< 45 PSIG AS SENSED BY CI-731-PS

,m REDUNDAMT INDICATION WHICH WILL VERIFY ALARM:

LOWLOCALPRESSURESONPUMPSUCTIhNGAUGECI-733-PI o

OPERATOR ACTIONS FOR A VALID ALARM:

o CHECK CIT-I LEVEL o INVESTIGATE THE CAUSE OF LOW SUCTION PRESSURE o MONITOR REACTOR CAVITY TEMPERATURES ON AH 1003-TIR PER OP-409 o CHECK CIP-2A/2B OISCHARGE PRESSURE DISCUSSION:

THIS CONDITION COULD BE CAUSED BY A LOW LEVEL IN THE. EXPANSION TANK, OR BY EXCESSIVE FLOWRATE. THE LINE UP OF THE SYSTEM SHOULD BE VERIFIED.

A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE 1FFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.

f

REFERENCES:

DRAWING'208-077 SHEET CI-19 SENSING ELEME T: CI-731-PS AR-401 Rev. 19 Page'69

W ENCLOSURE 1

?

[J

)

(Page 68 of 183) x.

PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 I

I TUFsBIN2 BLDG I

FIRE ALERT I

I I

EVENT POINT 0443 INDICATED CONDITION:

o TEMPERATURE > 135'F AS SENSED BY AH-125-TS EXISTS IN THE INTAKE PLENUM FOR AHF-16A/168

(

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-16A TRIPS o AHF-16B TRIPS OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE AHF-16A/AHF-16B ARE SHUT DOWN o REFER TO THE CR3 PRE FIRE PLAN o REFER TO Ar-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE INTAKE DUCT OF AHF-16A/AHF-168.

REFERENCES:

DRAWING 208-005 SHEETS AH-058, DRAWING 308846

i SENSING ELEMENT: AH-125-TS AR-401 Rev. 19 Page 70

1 l

ENCLOSURE 1 O

(Page 69 of 183)

L..)

PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 I

I I

I TURBINE BLDG I

I Fli4E ALERT I

I l

l 1

I EVENT POINT 0444 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-126-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-126-CE o TEMPERATURE > 135*F AS SENSED BY AH-126-TS EXISTS IN THE RETURN AIR DUCT g

FROM 119' SWITCH GEAR ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o THIS ALARM WILL RESULT IN THE ACTUATION OF THE FOLLOWING FIRE DAMPERS FD-38, FD-40, FD-48, FD-49, AND FD-50 OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE AHF-16A/AHF-16B ARE SHUT DOWN o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE RETURN AIR DUCT FROM 119' SWITCH GEAR ROOM TO AHF-16A/AHF-16B.

REFERENCES:

DRAWING 208-005 SHEETS AH-058, AH-060, AND DRAWING 308846 SENSING ELEMENT: AH-126-TS, AH-126-CE, 3AH-126-TS/RR-HV-V AR-401 Rev. 19 Page 71

ENCLOSURE 1

-p

-Q

-(Page 70 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 I

l l

l TURBINE BLDG I

I FIRE ALERT l-I 1

I I

l EVENT POINT 0448 INDICATED CONDITION:

o. PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-127-CE o TROUBLE HAS BEEN. DETECTED IN THE CIRCUITS FOR AH-127-CE o TEMPERATURE > 135'F AS SENSED BY AH-127-TS EXISTS IN THE RETURN AIR DUCT s

ROM 95' SWITCH GEAR ROOM i

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o. THIS ALARM WILL RESULT IN THE ACTUATION OF THE FOLLOWING FIRE DAMPERS

.FD-39 AND FD-41 OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE AHF-16A/AHF-168 ARE SHUT DOWN o REFER TO THE PRE FIRE PLAN o REFER TO AP-880 t

DISCUSSION:

THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE RETURN AIR. DUCT FROM 95' SWITCH GEAR ROOM TO AHF-16A/AHF-168.

1,fN.

REFEP,ENCES:

DRAWING 208-005 SHEETS AH-059, AH-060, AND DRAWING 308846 SENSING ELEMENT: AH-127-TS, AH-127-CE, 3AH-127-TS/RR-HV-V AR-401 Rev. 19 Page 72

,r g ENCLOSURE 1

)

(Page 71 of 183)

.\\ J PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01

-=

r- ~

I TURBINE BLDG FIRE ALERT I

I EVENT POINT 0449 INDICATED CONDITION; o ONE OF THE FOLLOWING TEMPERATURE SWITCHES HAS ACTUATED AT >135'F AH-153-TS AH-523-TS AH-524-TS O

y.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FIRE DAMPERS FD-52 FD-53, AND FD-54 TRIP o AHF-25A, AHF-25B, AND AHF-25C TRIP IF OPERATING OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY TURBINE BUILDING OPERATOR TO INVESTIGATE THESE TURBINE BUILDING SUPPLY FANS o REFER TO AP-880 DISCUSSION:

THIS ALARM INDICATES THAT THE FIRE DAMPERS FOR AHF-25A/B/C HAVF ACTUATED AHF-25A/B/C SHOULD SHUTDOWN AUTOMATICALLY.

REFERENCES:

DRAWING 208-005 SHEET AH-061, AH-70, DRAWING 308846 O)

(

SENSING ELEMENT: AH-153-TS, AH-523-TS, AH-524-TS, AND RELAY 3HBTIA AR-401 Rev. 19 Page 73

e

)-

f- _

ENCLOSURE 1 (Page 72 of 183)

-PSA ANNUNCIATOR Rc.SPONSE PSA-X-03-01 F-03-01 5

I I

I I

TURGINE BLDG I

FIRE ALERT I

I EVENT POINT 0450 INDICATED CONDITION:

o ONE OF THE FOLLOWING TEMPERATURE SWITCHES HAS ACTUATED AT >135"F AH-155-TS AH-527-TS AH-528-TS Oh REDUNDANT INDICATION WHICH W'LL VERIFY ALARM:

o AHF-26A, AHF-26B, AND AHF-26C TRIP IF OPERATING OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY TURBINE BUILDING OPERATOR TO INVESTIGATE THESE TURBINE BUILDING SUPPLY FANS o REFER TO AP-880 DISCUSSION:

THIS ALARM INDICATES THAT THE FIRE DAMPERS FOR AHF-26A/B/C HAVE ACTUATED. AHF-26A/B/C SHOULD SHJTDOWN AUTOMATICALLY.

p)_

REFERENCES:

DRAWING 208-005 SHEET AH-064, AH-70, DRAWING 308846

(

SENSING ELEMENT: AH-155-TS, AH-527-TS, AH-528-TS, AND RELAY 3HBT2 AR-401 Rev. 19 Page 74

1 r% --

ENCLOSURE 1-LI:

(Page 73 of_183)-

PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 l

I I

I TURBINE BLDG l

l FIRE ALERT I

I I

I I

I EVENT POINT 0451

-INDICATED CONDITION:

o ONE OF THE FOLLOWING TEMPERATURE SWITCHES HAS ACTUATED AT >135'F AH-154-TS AH-525-TS AH-526-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-27A, AHF-278, AND AHF-27C TRIP IF OPERATING OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY TURBINE BUILDING OPERATOR TO INVESTICATE THESE TURBINE BUILDING SUPPLY FANS o REFER TO AP-880 DISCUSSION.-

THIS ALARM INDICATES THAT THE FIRE DAMPERS FOR AHF-27A/B/C HAVE ACTUATED. AHF-27A/C/C SHOULD SHUTDOWN AUTOMATICALLY.

REFERENCES:

DRAWING 208-005 SHEET AH-067, AH-70, DRAWING 308846

,/

SENSING ELEMENT: AH-154-TS, AH-525-TS, AH-526-TS, AND RELAY 3HBT3 l

l

~

AR-401-Rev. 19 Page 75

..s.

S h

-ENCLOSURE 1

- Q!!

(Page 74 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-01 F-03-01 E

Z l

l I

l TURBINE BLDG I

I HRE ALERT I

I I

1 I

I EVENT POINT 1118 l

INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-723-CE o TROUBLE HAS BEEN DETECTED-IN THE CIRCUITS FOR AH-723-CE REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o - DETECTION OF PR0v0 CTS OF COMBUSTION WILL TRIP AHF-49 IF RUNNING OPERATOR ACTIONS FOR A VALID ALARM:

'o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE INSTRUMENT CAL LAB 14S' TURBINE DECK.

REFERENCES:

DRAWING 208-005 SHEETS AH-151 AND AH-152 SENSING ELEMENT: AH-723-CE AR-401 Rev. 19 Page 76

6

.ps _

' ENCLOSURE 1

)

(Page 75 of 183)

- %/

PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 AUX BLDG FIRE ALERT EVENT POINT 0006 INDICATED CONDITION:

o PENETRATION COOLING DUCT TEMPERATURE UPSTREAM OF FD-278 IS >165'F AS SENSED BY AH-1004-TS REDdNDANT INDICATION WHICH WILI VERIFY ALARM:

1 o PENETRATION COOLING FANS AH 9A/98 TRIP ON INTERLOCK OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE AHF-9A/98 ARE SHUTDOWN o INVESTIGATE CAUSE OF ALARM DISCUSSION:

THIS ALARM IS AN INDICATION OF A POSSIBLE FIRE IN THE DUCT WORK.

CONSIDERATION SHOULD BE CIVEN TO CONSULTING FIRE PLANS FOR THE APPROPRIATE ACTIONS. AH-1004-TS IS A MANUAL RESET TEMPERATURE _ SWITCH LOCATED AT INT. BLDG. 95' ELEV. NEXT TO THE LOCAL CONTROL STATION FOR

_AHF-9A AND 9B.

REFERENCES:

DRAWING 208-005 SHEET AH-056, DRAWING 308849 SENSING ELEMENTi AH-1004-TS

-AR-401~

Rev. 19 Page 77 l

l I

1x ENCLOSURE 1

f~3

(]

(Page 76 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 AUX BLDG FIRE ALERT EVENT POINT 0380 INDICATED CONDITION:

o RB PURGE SUPPLY DUCT TEMP IS >135T AS SENSED BY AH-23-TS, OR PRODUCTS OF COMBUSTION HAVE BEEN SENSED BY AH-23-CE AND/OR AH-24-CE, OR RELAY 3PSFP HAS ACTUATED o RB PURCE SUPPLY DUCT TEMP IS <70*F AS SENSED BY AH-645-TS p

O REDUNDANT INDICATION WHICH WILL VERIFY-ALARM:

o PURGE SUPPLY FANS AHF-6A/6B TRIP o PURCE SUPPLY DAMPER AHV-1D CLOSES ON LOW PURGE SUPPLY FLOW OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF T' E ALARM o SECURE RB PURGE PER OP-417 IF HIGH TEMP ALARM o REFER TO AP-880, IF HIGH TEMP ALARM o CHECK CORE FLOOD TANK FRESSURE/ TEMP, IF LOW TEMP ALARM s

DISCUSSION:

THIS IS INDICATIVE OF A FIRE IN THE PURCE SUPPLY FAN DISCHARGE DUCT THE TEMPERATURE AND PRODUCT OF COMBUSTION DETECTORS SENSE THE DISCHARGE UPSTREAM OF THE RECIRCULATION DAMPER. THE LOW TEMPERATURE ALARM HAS NO INTERLOCKS ASSOCIATED WITH IT.

h-

REFERENCES:

DRAWING 208-005 SHEETS AH-020, AND AH-15, DRAWING 308849 SENSING ELEMENT: AH-23-TS, AH-23-CE, AH-24-CE, AH-645-TS, AND RELAY 3PSFP AR-401 Rev. 19 Page 78

t.

r~s-ENCLOSURE-1

().

f.Page 77 of 183)

PSA ANNUNCIATOR RESPONSE' PSA-X-03-02 F-03-02

-w AUX BLDG FIRE ALERT

. EVENT POINT 0387 INDICATED CONDITION:

o RB PURGE EXHAUST DUCT TEMP IS >135T AS SENSED BY AH-295-TS, OR PRODUCTS OF COMBUSTION HAVE BEEN SENSED BY AH-295-CE, OR RELAY 3PEFP HAS ACTUATED

- (j REDUNDANT INDICATION WHICH WILL VERIFY ALARM:-

o PURGE EXHAUST FANS AHF-7A/78 TRIP OPERATOR ACTIONS-FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF THE ALARM o SECURE THE RB PURGE REFER TO OP-417 o REFER TO AP-880 DISCUSSION:

THIS IS INDICATIVE OF A FIRE IN THE PURGE EXHAUST DISCHARGE DUCT THE TEMPERATURE:AND PRODUCT OF COMBUSTION DETECTORS SENSE THE DISCHARGE OF THE FANS

REFERENCES:

DRAWING'208-005 SHEETS AH-020, AND AH-15,. DRAWING 308849

!]

SENSING ELEMENT: AH-295-CE, AH-2';5-TS, AND RELAY 3PEFP AR-401 Rev. 19 Page 79 i

d w

d ENCLOSURE-1

'j]J (Page 78 of 183)

-(/

PSA ANNUNCIATOR RESPONSE-PSA-X-03-02 F-03-02 p.+ t 1

' AUX BLDGi FIRE ALERT--

f EVENT POINT 0391 INDICATED CONDITION:

t o TEMPERATURE IS >135"F IN SPENT FUEL AIR HANDLING FAN AHF-8A DISCHARGE

- DUCT WORK AS SENSED BY AH-314-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-8A TRIPS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF THE ALARM o PEFER TO AP-880 DISCUSSION:

'THIS IS INDICATIVE OF-A FIRE IN THE SPENT FUEL COOLING UNIT DISCHARGE

-DUCT CONSIDERATION SHOULD BE CIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION

REFERENCES:

bRAWIoG 208-005 SHEETS _AH-026, DRAWT.NG 308849

~

f(,

SENSING ELEMENT: AH-314-TS LAR-40I'.

Rev. 19 Page 80

q-

~

,/~V ENCLOSURE l' (Page 79 of 183)

(j PSA ANNUNCIATOR RESPONSE-

~PSA-X-03-02 F-03-02 AUX BLDG FIRE ALERT EVENT POINT 0394 INDICATED CONDITION:

-o TEMPERATURE IS >135T IN SPENT FUEL AIR HANDLING FAN AHF-8B DISCHARGE DUCT WORK AS SENSED BY AH-409-TS l'3

).j REDUNDANT: INDICATION WHICH WILL VERIFY ALARM:

o AHF-8B TRIPS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE THE CAUSE OF THE ALARM o REFER TO AP-880 DISCUSSION:

'THIS IS.' INDICATIVE OF A FIRE IN THE SPENT FUEL COOLING UNIT DISCHARGE DUCT CONSIDERATION SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP-IN DETERMINING A ' COURSE OF ACTION

REFERENCES:

' DRAWING 208-005 SHEETS AH-027 DRAWING 308849 g

SENSING-ELEMENT: AH-409-TS (AR-401 Rev. 19 Page 81 4

Ng n

t i

f 1

ENCLOSURE 1 (Page 80 of 183) d-PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 t

AUX BLDG FIRE ALERT EVENT POINT 0403 INDICATED CONDITION:

o TEMPERATURE 15 >135T IN SPENT FUEL AREA AIR HANDLING FAN AHF-10 DISCHARGE DUCT WORK AS SENSED BY AH-377-T5 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-10 TRIPS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGAU THE CAUSE OF THE ALARM o REFER TO AP-880 DISCUSSION:

THIS 15 INDICATIVE OF A FIRE IN THE SPENT FUEL FLOOR AIR HANDLING UNIT DISCHARLt DUCT CONSIDERATION SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS F03 ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION

REFERENCES:

DRAWING 208-005 SHEETS AH-044 DRAWING 308849 SENSING ELEMENT: AH-377-T5 AR-401.

Rev. Page 82

ENCLOSURE 1

(')s (Page 81 of 183)

(

PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 l

P AUX BLDG FIRE ALERT l

EVENT POINT 0410 i

INDICATED CONDITION:.

o TEMPERATUP.E IS >135T IN AUXILIARY BUILDING SUPPLY FAN DISCHARGE DUCT WORK AS SENSED BY AH-318-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-IIA /118 FANS TRIP OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE THE CAUSE OF THE ALARM o REFER TO AP-880 DISCUSSION:

r THIS-IS INDICATIVE OF A FIRE IN THE AUXILIARY BUILDING SUPPLY FANS DISCHARGE DUCT CONSIDERATION SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION i

REFERENCES:

- DFAWING 208-005 SHEETS AH-045 DRAWING 308849

.Q h

SENSING ELEMENT: AH-318-TS AR-401 Rev. 19 Page 83

. ~..

_ _ ~

i ENCLOSURE.1 l

OQ (Page 82 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 I

AUX BLDG FIRE ALERT' EVENT POINT 0416 INDICATED CONDITION:

4 o TEMPERATURE IS >I35*F IN AUXILIARY BUILDING RECIRC FAN SUCTION DUCT WORK AS SENSED BY AH-375-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-13 TRIPS OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE THE CAUSE OF THE ALARM o REFER TO AP 880 1

i DISCUSSION:

THIS IS INDICATIVE OF A FIRE IN THE-AUXILIARY BUILDING RECIRC FAN DISCHARGE DUCT CONSIDERATION-SHOULD BE GIVEN TO CONSULTING THE FIRE PLANS FOR ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION

REFERENCES:

DRAWING 208-005 SHEETS AH-048 DRAWING 308849

ySENSING ELEMENT: AH-375-TS s

i h

AR-401 Rev. 19' Page 84 x

3 I

4

ENCLOSURE 1

)

(Page 83 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 AUX BLDG F6RE ALERT EVENT POINT 0426 INDICATED CONDITION:

o TEMPERATURE 15 >135T IN AUXILIARY BUILDING EXHAUST DUCT WORK AS SENSED BY-AH-354-TS REDUNDANT INDICATION WHICH WILL-VERIFY ALARM:

AUXILIARYDUILDINGEXHAUSTFANSAHh-14A,AHF-148,AHF-14C,&AHF-14D o

TRIP OPERATOR ACTIONS FOR A VALIO ALARM:

o INVESTIGATE THE CAUSE OF THE ALARM o REFER TO AP-880 DISCUSSION:

THIS IS INDICATIVE OF A FIRE IN THE AUXILIARY BUILDING EXHAUST DISCHARGE DUCT, CONSIDERATION SHOULD BE CIVEN TO CONSULTING THE FIRE PLANS FOR.

ADDITIONAL HELP IN DETERMINING A COURSE OF ACTION -

REFERENCES:

DRAWING 208-005 SHEETS AH-001 AND AH-005, DRAWING 308849 SENSING ELEMENT: AH-354-TS

'AR-401 Rev. 19 Page 85

I ENCLOSURE 1-(Page 84 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 i

i AUX BLDG FIRE ALERT EVENT POINT 0431 INDICATED CONDITION:

t

,t o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-156-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-156-CE o TEMPERATURE > 135'F AS SENSED BY AH-156-TS EXISTS AT THE 95' LEVEL l

INTERMEDIATE BUILDING REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH TEMPERATURE WILL RESULT IN THE TRIP OF AHF-24A/B IF RUNNING o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-42, AND FD-43 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER A TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE OR A HIGH TEMPERATURE IN THE R00'4.

1

REFERENCES:

DRAWING 208-005 SHEETS AH-51, AND AH-55. DRAWING 308846 SENSING ELEMENT: AH-156-CE, AH-156-TS, RELAY 3AH-156-TS/RRIA-

-AR-401 Rev. 19 Page 86

-.~

.- ~.. -.. -.

F i

1 i

,m -

ENCLOSUfLLI i

( /.

f (Page 85 of 183) s PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 i

t AUX BLDG FIRE ALERT l

EVENT POINT 0433 INDICATED CONDITION:

o TEMPERATURE > 135T AS SENSED BY AH-157-TS EXISTS AT THE 95' LEVEL INTERMEDIATE BUILDING i

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HICH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-42, AND FD-43 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN i

i o REFER TO AP-880 DISCUSSION:

-THE IS CONDITION IS INDICATIVE OF A FIRE OR A-HIGH TEMPERATURE IN THE 95' INTEF. MEDIATE BUILDING.

REFERENCES:

DRAWING 208-005 SHEETS AH-51, AND AH-55. DRAWING 308846 T

_. i:

SENSING ELEMENT: AH-157-TS, AR 401L Rev 19 Page 87 a-w w

g w--o g

y.-

e-

+

w

,,e.

m s,

3 e-ENCLOSURE 1 (Page 86 of-?,83)

PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03d2 i

i AUX BLDO FIRE ALERT t

L EVENT POINT 0435 INDICATED CONDITION:

o PENETRATION COOLING SUPPLY AIR DUCT TEMPERATURE UPSTREAM OF FD-32 IS

>I35T AS SENSED BY AH-737-TS. OR AH-737-T5 TROUBLE CIRCUIT HAS ACTUATED l

(y~

REDUNDANT INDICATION WHICH WILL VERIFY-. ALARM:

o FD-32 FIRE DAMPER CLOSES o LOCAL TROUBLE ALARM ON AH-737-T5 OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY FD-32 CLOSED o REFER TO AP-880 DTSCUSSION:

THIS IS INDICATIVE OF A HIGH TEMPERATURE CONDITION IN THE TURBINE BUILDING AD3ACENT TO THE FAN INTAKE, OR A PROBLEM WITH THE DETECTOR.

f r

4O

REFERENCES:

DRAWING 208-005 SHEET AH-056, DRAWING 308849 G.

SENSING ELEMENT: AH-737-TS, AH-737-T5 TROUBLE CIRCUIT AR-401-Rev. 19 Page 88-

f i

ENCLOSURE.1 O,

L (Page 87 of 183) i PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 l

i AUX BLDG FIRE ALERT EVENT POINT 0437.

. +

4 INDICATED CONDITION:

o PENETRATION COOLING SUPPLY AIR DUCT TEMPERATURE UPSTREAM OF FD-33 IS

>135T AS SENSED BY AH-738-TS. OR AH-738-TS TROUBLE CIRCUIT HAS ACTUATED O

REDUNDANT INDICATION WHICH WILL VERIFY.. ALARM:

4 o FD-33 FIRE DAMPER CLOSES o LOCAL TROUBLE ALARM ON AH-738-TS OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY FD-33 CLOSED I

k-DISCUSSION:

THIS IS INDICATIVE OF A HICH TEMPERATURE' CONDITION IN THE OUTSIDE AIR INTAKE.'OR OF A PROBLEM WITH THE DETECTOR

[

REFERENCES:

DRAWING 208-005 SHEET AH-057, DRAWING 308849 i

SENSING ELEMENT: AH-738-TS AND AH-38-TS TROUBLE

'AR-401 Rev.-19 Page 89 l

. - -.. ~ -.....

- -. ~ ~ _

L ENCLOSURE 1 i

O (Page 88 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 l

AUX BLDG FIRE ALERT EVENT POINT 0439 INDICATED CONDITION:

o PENETRATION COOLING FAN DISCHARGE DUCT TEMPERATURE 15 >110*F AS SENSED BY AH-305-T5

(

)

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL TROUBLE ALARM ON AH-305-T5 OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE CHILL WATER 15 SUPPLIED TO THE OPERATING PENETRATION COOLER o INVESTICATE THE CAUSE OF THE HIGH TEMPERATURE ALARM e REFER TO AP-880 o ENSURE THAT CHV-233 THRU CHV-236 HAVE NOT CLOSED DUE TO HIGH TEMPERATURE FRC~t A HIGH ENERGY LINE BREAK (HELB) IN THE 18.

DISCUSSION:

THIS IS INDICATIVE-QF A HIGH 1EMPERATURE CONDITION IN THE DISCHARGE

- THE PENETRATION COOLING FANS. OR OF A PROBLEM WITH THE DETECTOR.

IF TEMPERATURE >135F THIS ALARM COULD BE THE RESULT OF A HIGH ENERGY

.LINE. BREAK (HELB) IN THE IB CAUSING STEAM FLOW ACROSS THE COILS OF AHHE 13A/B i

REFERENCES:

- DRAWING 208-005 SHEET AH-056, DRAWING 308849 SENSING ELEMENT: AH-305-T5 AR-401

-Rev. 19 Page 90

~

+

ENCLOSURE 1

^\\

(Page 89 of 183)

(Q PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 j

l AUX BLDG FIRE ALERT

=

EVENT POINT 0513 INDICATED CONDITION:

I o TEMPERATURE > 135T A5 SENSED BY AH-132-T5 EXISTS IN CLEAN MACHINE SHOP AIR HANDLING UNIT AHU-2 DISCHARGE O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH TEMPERATURE WILL RESULT IN A TRIP OF AHU-2 OPERATOR ACTIONS FOR A VAL % ALAP.M:

o -REFER TO THE CR3 FRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE DISCHARGE DUCT OF AHU-2.

L

REFERENCES:

DRAWING 208-005 SHEETS AH-094 DRAWING 308846 SENSING ELEMENT: AH-132-TS.

O I

AR-401

.Rev. 19

.Page 91 1

I

^

ENCLOSURE 1

(~'

(

(Page 90 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-02 F-03-02 AUX BLDG FIRE ALERT -

EVENT POINT 0514 INDICATED CONDITION:

o TEMPERATURE > 135T AS SENSED BY AH-165-T5 EXISTS IN HOT MACHINE SHOP AIR HANDLING UNIT AHU-3 DISCHARGE REDUNDANT INDICATION WHICH.WILL VERIFY ALARM:'

HIGHTEMPERATUREWILLRESULTINAiRIPOFAHU-3 o

OPERATOR ACTIONS FOR A VALID ALARM:

i o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

'THIS CONDITION IS INDICATIVE OF A FIRE OR A HIGH TEMPERATURE IN THE DISCHARGE DUCT OF AHU-3.

+

I

REFERENCES:

DRAWING 208-005 SHEETS AH-095, DRAWING 308846 f

5ENSING ELEMENT: AH-165-T5 AR-401 Rev. 19 Page 92

r I

ENCLOSURE 1

(~}

(Page 91 of 183)

V PSA ANNUNCIATOR RESPONSE PSA-X-03-03 F-03-03 f

DIESEL ROOM FIRE ALERT EVENT POINT 0460 d

INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-364-CE o ' TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR A:1-364-CE

' l3

- \\

/

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AN ALARM ON AH-364-CE WILL ACTUATE FD-36 AND FD-37 OPERATOR ACTIONS FOR A VALID ALARM:

o DEENERGIZE AHF-28A LOCALLY OR VIA ACDP-50 BREAKER 13 o REFER TO THE PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:-

THIS CONDITION IS INDICATIVE OF EITHER A TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE ECDG-1A ROOM.

REFERENCES:

.' DRAWING 208-005 AH-073, AH-076, AND DRAWING 308849 SENSING ELEMENT: AH-364-CE,.3AH-364-CE/ RELAY LAR-401 Rev '19 Page 93

l h

ENCLOSURE 1 i

-).

y (Page 92 of 183) l PSA ANNUNCIATOR RESPONSE PSA-X-03-03 F-03-03 DIESEL ROOM FIRE ALERY EVENT POINT 0465 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION-HAVE BEEN DETECTED BY AH-374-CE o -TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-374-CE O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AN ALARM ON AH-374-CE WILL ACTUATE FD-34 AND FD-35 OPERATOR ACTIONS FOR A VALID ALARM:

o DEENERGIZE AHF-28B LOCALLY OR VIA ACDP-50 BREAKER 14 o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 t

i DISCUSSION:

THIS CONDITION 11 INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS-OR A FIRE IN THE EGDC-IB ROOM,

REFERENCES:

DRAWING 208-005 SHEETS AH-073, AH-079, AND DRAWING 308849 4

5ENSING ELEMENT: AH-374-CE, 3AH-374-CE/ RELAY AR-401 Rev. 19 Page 94

f.ffCLD5!E_1

( )T (Page 93 of 183) i i

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT 4

t EVENT POINT 0481 INDICATED CONDITION:-

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-33-CE o TROUBLE HAS BFEN DETECTED IN THE CIRCUITS FOR AH-33-CE O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AN ALARM ON AH-33-CE WILL ALLOW THE CONTROL COMPLEX VENTILATION SYSTEM TO BE PLACED IN A SM0KE REMOVAL MODE OF OPERATION OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS,-OR A FIRE IN THE COMMON RETURN DUCT DOWNSTREAM OF AHF-19A/B C

REFERENCES:

DRAWING 208-005 SHEETS AH-090, AH-079, AND bRAWING 308847 b

SENSING ELEMENT: AH-33-CE, 3AH-33-CE/ RELAY

AR-401 '

Rev. 19 Page 95

ENCLOSURE 1 (Page 94 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT i

F EVENT POINT 0492 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-529-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-529-CE o TEMPERATURE > 135T AS SENSED BY AH-529-TS EXISTS AT THE 124' LEVEL OF THE CONTROL COMPLEX qV RECUNDANT INDICATION WHICH WILT VERIFY AtARM:

o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-13 AND FD-84 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS.-OR A FIRF IN.THE 124' ELEVATION OF THE CONTROL COMPLEX

REFERENCES:

DRAWING 208-005 SHEETS AH-101, AH-106, AND DRAWING 308847 b

SENSING ELEMENT: AH-529-TS AH-529-CE, 3AH'-529-TS/ RELAY AR-401?

Rev 19 Page 96-

/~

ENCLOSURE 1 (Page 95 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 I

CNTRL COMPLEX FIRE ALERT EVENT POINT 0494 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-214-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-214-CE o TEMPERATURE > 135'F AS SENSED BY AH-214-TS EXISTS AT THE 124' LEVEL OF THE CONTROL COMP'.EX. ES 480V "A" SWITCHGEAR ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-4 AND FD-16 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 f

DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 124' ELEVATION OF THE CONTROL COMPLEX 8EFERENCES:

DRAWING 208-005 SHEETS AH-102, AH-107, AND DRAWING 308847 f

/

SENSING ELEMENT: AH-214-TS AH-214-CE 3AH-214-TS/ RELAY

.hR-401 Rev. 19 Page 97 y

v e

~

+

v n

l l

i p

fJiCLORRE_1

[

Q (Page 96 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT EVENT POINT 0495 INDICATED CONDITION:

o PRODUCTS OF-COMBUSTION HAVE BEEN DETECTED BY AH-212-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-212-CE o TEMPERATURE > 135T AS SENSED BY AH-212-TS EXISTS AT THE 124' LEVEL OF

~

THE CONTROL COMPLEX. ES 480V "B" SWITCHCEAR ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HICH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-2 AND FD-14 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN

-o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 124' ELEVATION OF THE CONTROL COMPLEX.

r

REFERENCES:

DRAWING 208-005 SHEETS AH-102, AH-106, AND DRAWING 308847

(

SENSING ELEMENT:.AH-212-TS AH-212-CE, 3AH-212-TS/ RELAY w

.: AR-401 Rev. 19 Page 98

i ENCLOSURE _1 f

(Page 97 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 i

CNTRL COMPLEX FmE ALERT EVENT POINT 0498 e

INDICATED CONDITION:

o PRODUCTS OF COMBUSTION MAVE BEEN DETECTED BY AH-216-CE 5

o TROUBLE HAS BEEN DETECTED IN TH6 CIRCUITS FOR AH-216-LE o TEMPERATURE > 135T AS SENSED BY AH-216-TS EXISTS AT THE 108' LEVEL OF

{

THE CONTROL COMPLEX. ES 4160V "A" SWITCHCEAR ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HICH TEMPEPATURE WILL RESULT IN THE ACTUATION OF FD-6 AND FD-18

^

OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

T!!IS CONDITION IS INDICATIVE OT EITHER TROUBLE IN THE FIRE DETELTION CIRCUITS, OR A FIRE IN THE 108' ELEVATION OF 'fHE CONTROL COMPLEX.

\\.

REFERENCES:

- DRAWINC 208-005 SHEETS AH-103, AH-107, AND DRAWING 308847

\\

SENSING ELEMENT: AH-216-TS AH-216-CE, 3AH-216-TS/ RELAY o

l AR-401:

_Rev. 19

Page 99 L '.

._. ~

t ENCLOSURE 1

/]

(Page 98 of 183)

V PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 i

CNTRL COMPLEX FIRE ALERT EVENT POINT 0499 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-21%-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-215-CE o TEMPERATURE > 135T AS SENSED BY AH-215-TS EXISTS AT THE 108' LEVEL OF THE CONTROL COMPLEX. ES 4160V "B" SWITCHGE/,R ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HICH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-S AND FD-17 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 4

DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 108' ELEVATION OF THE CONTROL COMPLEX.

REFERENCES:

DRAWING. 208-005 SHEETS AH-103, AH-107 AND DRAWING 308847 SENSING ELEMENT: AH-215-TS AH-215-CE -3AH-215-TS/ RELAY AR-401-Rev. 19 Page 100

. ~..

ENCLOSURE 1

^

(Page 99 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 l

Y CNTRL COMPLEX FIRE ALERT EVENT POINT 0500 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-220-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS kOR AH-220-CE o TEMPERATURE > 135T AS SENSED BY AH-220-TS EXISTS IN "A" BATTERY CHARCER

'[-

ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HICH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-42 IND FD-43 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880

(

DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER A TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE, OR A HIGH TEMPERATURE IN THE ROOM,

REFERENCES:

DRAWING 208-005 SHEET AH-104 7-bl SENSING ELEMENT: AH-220-TS, AH-220-CE AR-401-Rev. 19 Page 101

h

[NCLOSURE-1 f

(Page 100 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 t

CNTRL COMPLEX FIRE ALERT I

r EVENT POINT 0501 t

INDICATEDCONDITIbN:

1 e PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-217-CE d

o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-217-CE o TEMPERATURE > 135*F AS SENSED BY AH-217-TS EXISTS IN "B" BATTERY CHARCER ROOM REOUNDANT INDICA 110N WHICH WILL VcRIFY ALARM:

o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-19 OPEkATOR ACTIONS FOR A VALID ALARM:

o Rt:FER TO THE CR3 PRE FIRE PLAN

[

o REFER TO AP-880 DISCUSSIDN:

THIS CONDITION IS INDICATIVE OF EITHER A TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE OR A HIGH TEMPERATURE IN THE ROOM.

~

REFERENCES:

DRAWING 208-005 SHEETS AH-103, AH-109, AND DRAWING 308847 SENSING ELEMENT: AH-217-TS.-AH-217-CE AR-401 Rev. 19

.Page 102

~

ENCLOSURE 1 (I

(Page 101 of 183) 3 PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT i

EVENT POINT 0502 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-219-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-219-CE o TEMPERATURE > 135T AS SENSED BY AH-219-T5 EXISTS IN "A" BATTERY ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

4 o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-9 AND FD-21 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

-THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE, OR A HIGH TEMPERATURE IN THE ROOM,

REFERENCES:

DRAWINC 208-005 SHEETS AH-104, AH-108, DRAWING 306847

\\

SENSING ELEMENT: AH-219-CE, AH-219-T5 AR-401' Rev. 19 rage 103

y^

ENOSSURE 1

\\

(Page 102 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 I

CNTRL COMPLEX FIRE ALERT EVENT POINT 0503 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVI BEEN DETECTED BY AH-218-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-218-CE o TEMPERATURE > 135T AS SENSED BY AH-218-TS EXISTS IN THE "B" BATTERY ROOM REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-220 AND FD-222 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS,-A FIRE OR A HIGH TEMPERATURE IN THE ROOM.

REFER TO THE CR3 FIRE PROTECTION PLAN FOR ADMINISTRATIVE REQUIREMENTS.

l iSFERENCES:

DRAWING 208-005 SHEETS AH-103, AH-IO8 AND DRAWING 308847 i-h SENSING ELEMENT: AH-218-CE, AH-218-TS AR-401' Rev. 19 Page 104

?

i s

ENCLOSURE 1 j

)

(Page 103 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 e

s CNTRL COMPLEX FIRE ALERT i

I EVENT POINT 0504 l

INDICATED CONDITION:-

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-222-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-222-CE o TEMPERATURE > 135'F AS SENSED BY AH-222-TS EXISTS -IN THE "A" INVERTER ROOM i

REDUNDANT INDICATION WHICH WILL VERIFY-ALARM:

o HIGH TEMPERATURE-WILL RESULT IN THE ACTUATION OF FD-12 AND FD-24 OPERATOR ACTIONS'FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION.

CIRCUITS, A FIRE-OR A HIGH TEMPERATURE IN THE ROOM.

REFER TO' THE CR3 FIRE PROTECTION PLAN FOR ADMINISTRATIVE REQUIREMENTS.

REFERENCES:

DRAWING 208-005 SHEETS AH-104, AH-109 AND DRAWING 308847

- $(

SENSING ELEMENT: AH-222-CE, AH-222-TS

.x 1AR-40li Rev' 19

'Page 105 6-

-,-3.

--,,,-wg.,-<--

9

+

ENCLOSURE 1 (Page 104 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 i

l i

CNTRL COMPLEX FIRE ALERT EVENT POINT 0505 INDICATED CONDITION:

O PRODUCTS OF COMSUSTION HAVE BEEN DETECTED BY AH-221-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-221-CE o TEMPERATURE > 135*F AS SENSED BY AH-221-TS EXISTS IN THE "B" INVERTER ROOM REDUNDAN' INDICATION WHICH WILL VERIFY ALARM:

o HICH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-11 AND FD-23 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-88C '

DISCUSSION:

THIS CONDITION IS INDICATIVE.0F EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, A FIRE OR A HIGH TEMPERATilRE IN THE ROOM.

REFER TO THE CR3' FIRE PROTECTION. PLAN FOR ADMINISTRATIVE REQUIREMENTS.

REFERENCES:

DRAWING 208-005 SHEETS AH-104, AH-109 AND DRAWING 308847 SENSING ELEMENT: AH-221-CE, AH-221-TS

'AR-401-Rev. 19 Page 106 i

,~

,.,,,e..n,,-w.,

,mm r,

wm

,,,-n-

-n.--

O ENCLOSURE 1

.Q-(Page 105 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT I

EVENT POINT 0506 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-235-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-235-CE o TEMPERATURE > 135*F AS SENSED BY AH-235-T5 EXISTS IN THE CONTROL COMPLEX SlAIR W LL REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-25 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION 15 INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUIT 5,A FIRE OR A HIGH TEMPERATURE IN THE ROOM.

REFER TO THE CR3 FIRE PROTECTION PLAN FOR ADMINISTRATIVE REQUIREMENTS.

REFEkENCES: DRAWING 208-005 SHEETS AH-105, AH-109 AND DRAWING 308847 SENSING ELEMENT: AH-235-CE, AH-235-T5 AR-401 Rev. 19 Page 107

3 i

t..

i N

ENCLOSURE 1 (h

(Page 106 of 183)

PSA ANNUNCIATOR' RESPONSE PSA-X-03-04 F-03-04 i

CNTRL COMPLEX FIRE ALERT EVENT POINT 0507 INDICATED CONDITION:

o PRODucr5 0F COMBUSTION HAVE BEEN DETECTED BY AH-236-CE o TROUBLE HAS BELN DETECTED IN THE CIRCUITS FOR AH-236-CE o TEMPERATURE > '.35T AS SENSED BY AH-236-T5 EXISTS AT THE 108' LEVEL OF THE CONTROL COMPLEX PEDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-26 AND FD-27 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRL PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TKOUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 108' ELEVATION OF THE CONTROL COMPLEX

REFERENCES:

DRAWING 208-005 SHEETS AH-105, AH-109, AND b WING 308847-l p>'

SENSING ELEMENT: AH-236-T5'AH-236-CE,'3AH'236-TS/ RELAY AR-401 Rev. 19

'Page 108 i

7

+

w-_.-

y I

f'i ENCLOSURE _1

()

(Page 107 of 183)

PSA ANNU'NCIATOR RESPONSE PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT EVENT POINT 1532 INDICATED CONDITION:

o TEMPERATURE > 135T AS SENSED BY AH-534-TS EXISTS IN THE CONTROL COMPLEX MAIN AIR HANDLING SUPPLY DUCT AT 145' ELEVATION O

RED. DANT INDICATION WHICH WILL VERIFY ALARM:

c. HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-56 OPERATOR ACTIONS FOR A-VALIO ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

= THIS CONDITION IS INDICATIVE OF A FIRE IN THF MAIN SUPPLY DUCT OF THE CONTROL COMPLEX.

t REFERiNCES:

DRAWING 208-005 SHEETS AH-101, AH-106, AND DRAWING 308847 SENSING ELEMENT: AH-534-TS, 3AH 534-TS/RR-HV-AU~

AR-4011 Rev. 19.

'Page 109 4

N, fi ENCL.

'l 1

()

(Page 108 of 183)

PSA ANNUNCIATOR RESPONSE-PSA-X-03-04 F-03-04 CNTRL COMPLEX FIRE ALERT

=

EVENT POINT 1533 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-531-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-531-CE O

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o PRODUCTS OF COMBUSTION DETECTION WILL RESULT IN THE ACTUATION OF FD-51 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE ObfSIDE AIR INTAKE OF THE CONTROL COMPLEX.

g

REFERENCES:

DRAWING 208-005 SHEETS AH-101, AH-106, AND DRAWING 308847 SENSING ELEMENT: AH-531-CE AR-401 Rev. 19 Page 110

M ENCLOSURE 1

-( o (Page 109 of-183) g PSA ANNUNCIATOR-RESPONSE' PSA-X-03-04 F-03-04 l

l

__..LZ CNTRL COMPLEX FIRE ALERT EVENT POINT 1534 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-535-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-535-CE o TEMPERATURE > 135*F AS SENSED BY AH-535-TS EXISTS IN THE CONTROL COMPLEX MAIN SUPPLY DUCT 95' ELEVATION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF FD-55 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF EITHER TROUBLE-IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE MAIN SUPPLY DUCT OF THE CONTROL COMPLEX.

r

REFERENCES:

DRAWING 208-005 SHEETS AH-101, AH-106, AND DRAWING 308847 O

Q SENSING ELEMENT: AH-535-TS AH-535-CE, 3AH-535-TS/ RELAY L

l-l AR-401 Rev. 19 Page 111 l

e

,N ENCLOSURE'1 (Page 110 of 183)_

PSA ANNUNCIATOR RESPONSE PSA-X-03-04 F-03 '

CNTRL COMPLEX FIRE ALERT EVENT POINT 1535 INDICATED CONDITION:

o TEMPERATURE > 135T AS SENSED BY AH-533-TS EXISTS IN THE CONTROL COMPLEX MAIN RETURN AIR DUCT AT 145' ELEVATION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HICH TEMPERATURE WILL RESULT IN THE ACTUATION.0F FD-57 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880 DISCUSSION:

THIS CONDITION IS INDICATIVE OF A FIRE IN THE RETURN AIR DUCT OF THE CONTROL COMPLEX.

r'

REFERENCES:

DRAWING 208-005 SHEETS AH-101, AH-106, AND DRAWING 308847 SENSING ELEMENT: AH-533-TS. 3AH-533-TS 'RR-HV-AT l

AR-401 Rev. 19 Page 112 l

i

~

j ENCLOSURE 1 (Page 111 of 183) 1 PSA ANNUNCIATOR RESPONSE-PSA-X-03-04 F-03-04 I

l CNTRL COMPLEX FIRE ALERT t

EVENT POINT 1536 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN "TECTED BY AH-211-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-211-CE o TEMPERATUPS > 135"F AS SENSED BY AH-211-TS EXISTS AT THE 134' LEVEL OF O

.THE CONTROL COMPLEX

%)

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH TEMPERATURE WILL RESULT IN THE ACTUATION OF THE FOLLOWING:

FD-45, FD-46, FD-47, FD-81, FD-82, AND FD-83 OPERATOR ACTIONS FOR A VALID ALARM:

o REFER TO THE CR3 PRE FIRE PLAN o REFER TO AP-880.

DISCUSSION:,

THIS CONDITION IS INDICATIVE OF EITHER *1 ROUBLE IN THE FIRE DETECTION CIRCUITS, OR A FIRE IN THE 134' ELEVATION OF THE CONTROL COMPLEX IN THE CABLE SPREADING ROOM.

[D

REFERENCES:

DRAWING 208-005 SHEETS AH-105, AH-107, AND DRAWING 308847

- sy.

SENSING ILEMENT: AH-211-TS AH-211-CE, 3AH-211-TS/ RELAY AR-401' Rev. 19 Page 113

ENCLOSURE ~1

-(A)

_ (Page 112 of.183)

- v PSA ANNUNCIATOR RESPONSE PSA-X-03-05 F-03-05 RUSTY BLDG FIRE ALERT h

EVENT POINT 0427 INDICATED CONDITION:

o DUCT TEMPERATURE AT DISCHARGE OF AHF-46 IS > I25T AS SENSED BY AH-667-TS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-46 TRIPS DUE TO INTERLOCK OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE AHF-46 IS SHUTDOWN o INVESTIGATE CAUSE OF ALARM DISCUSSION:

THIS ALARM IS AN INDICATION OF A POSSIBLE FIRE IN THE DUCT WORK.

CONSIDERATION.SHOULD BE GIVEN TO CONSULTING FIRE PLANS FOR THE APPROPRIATE ACTIONS.

-AHF-46 IS THE RUSTY BUILDING RECIRC FAN.

REFERENCES:

DRAWING 208-005 SHEET AH-142 SENSING ELEMENT: AH-667-TS l

AR-401 Rev. 19 Page 114

i ENCLOSURE 1

.(

(Page 113 of-183)

.L PSA ANNUNCIATOR RESPONSE PSA-X-03-05 F-03-05 l-4 RUSTY BLDG FIRE ALERT

- EVENT POINT 0512 -

INDICATED CONDITION:

o' DUCT TEMPERATURE AT DISCHARGE OF AHU-7 IS > 125aF AS SENSED BY AH-670-T5 REDUNDANT' INDICATION WHICH WILL VERIFY ALARM:

c AHU-7 TRIPS Duc TO INTERLOCK OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE AHU-7 IS SHUTDOWN o INVESTIGATE CAUSE OF ALARM DISCUSSION:

THIS ALARM IS AN INDICATION OF A POSSIBLE FIRE IN THE DJCE WORK.

' CONSIDERATION SHOULD BE GIVEN TO CONSULTING FIRE PLANS FOR THE APPROPRIATE ACTIONS.

AHU-7 IS THE RUSTY BUILDING AIR CONDITIONING UNIT, t

REFERENCES:

DRAWING 208-005 SHEET AH-144 SENSING ELEMENT: AH-670-T5 AR-401 Rev. 19 Page 115

l ENCLOSURE 1

-~-

=.; t (Page 114 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-03-06 F-03-06 i

FIRE PUMP HOUSE FIRE ALERT-EVENT POINT 0455 INDICATED CONDITION:

o PRODUCTS OF COMBUSTION HAVE BEEN DETECTED BY AH-386-CE o TROUBLE HAS BEEN DETECTED IN THE CIRCUITS FOR AH-386-CE REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY TURBINE BUILDING OPERATOR.TO INVESTIGATE THE FIRE PUMP HOUSE.

DISCUSSION:

REFERENCES:

DRAWING 208-005 SHEET AH-072 SENSING ELEMENT: AH-386-CE.

AR-401 Rev. 19 Page 116

l ENCLOSURE 1-(Page 115 of 183) e PSA ANNUNCIATOR RESPONSE PSA-X-03-07 F-03,

~

l FIRE SYSTEM TROUBLE 4

EVENT POINT 0197 INDICATED CONDITION:

o FIRE SERVICE PANEL IN.THE CONTROL ROOM HAS AN UNACKNOWLEDGED OR UNRESET ALARM

'r k

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o ALARM ON THE FIRE SERVICE PANEL OR ONE OF THE PYROTRONICS PANELS OPERATOR ACTIONS FOR A VALID ALARM:

-o.IMMEDIATE INVESTIGATION OF ALARM CAUSE SHOULD BE INITIATED d

DISCUSSION:

REFER TO THE CR3 FIRE' PROTECTION PLAN FOR ADMINISTRATIVE REQUIREMENTS.

a

REFERENCES:

DRAWING 208-031 SHEET FS-21 q-

- w/ '

SENSING ELEMENT:

AR-401' Rev, 19 Page 117 v

r.

1

i

- fy ENCLOSURE 1

- (v)

(Page 116 of 183)

PSA-ANNUNCIATOR RESPONSE PSA-X-04-01' F-04-01 l

l REACTOR BLDG I

I PURGE FAN I

I TRIP l

l I

l l

l EVENT POINT 0384 INDICATED CONDITION:

o AHF-7A MOTOR NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION D.

bl REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CREEN LIGHT ON WITH A RED FLAG ON AHF-7A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE RB F;"lGE o REFER TO OP-417 DISCUSSION:

THIS CONDITION >%Y BE CAUSED BY ACTUATION OF A FIRE ALERT IN THE DdCT.

INDICATED BY EVENT POINT 0387, OR AN FSV-114 DELUCE VALVE ACTUATION

REFERENCES:

DRAWING 208-005 SHEETS AH-022, AH-015 (V-SENSING ELEMENT: CS/SC, CS/0, 42/498 RELAY I

i AR-401' Rev. 19 Page 118

ENCLOSURE 1

]

)

'(Page 117 of 183)

- v-PSA ANNUNCIATOR RESPONSE PSA-X-04-01 F-04 l l

REACTOR BLDG l

l PURGE FAN I

I TRIP l

l 1

I l-l EVENT POINT 0385 INDICATED CONDITION:

o AHF-78 MOTOR NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION Q

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-78 CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE RB PURCE o REFER TO OP-417 DISCUSSION:

THIS CONDITION MAY BE CAUSED BY ACTUATION OF A FIRE ALERT IN THE DUCT INDICATED BY_ EVENT POINT 0387, OR AN FSV-114 DELUGE VALVE ACTUATION t

REFERENCES:

DRAWING 208-005 SHEETS AH-023, AH-015 SENSING ELEMENT:

CS/SC, CS/0, 42/49B RELAY AR-401' Rev. 19 Page 119 j

-=

~ -

ENCLOSURE 1 p).(./ -

(Page 118 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-04-02 F-04-02 AH FLTR 1 A/B DIFF PRESS -

HIGH -

EVENT POINT 0497 INDICATED CONDITION:

o DIFFERENTIAL PRESS ACROSS AHFL-1A/1B IS > 5.2 "H20"AS 55NSED BY AH-586A-DPS, OR AH-586B-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH FLOW INDICATED ON AH-32-FIR o LOCAL DIFFERENTIAL PRESSURE INDICATIONS ON AH-586-DPI, LOCALLY NORTH / SOUTH END (AHFL A, FILTERS D, E, & F) (AHFL B, FILTERS A, B, & C)

OPERATOR ACTIONS FOR A VALID ALARM:

o REDUCE RB PURGE FLOW RATE o REFER TO OP-417.

o VERIFY ROUGHING FILTER DP < 0.9" H,0 LOCALLY (FILTERS A/F) o VERIFY HEPA FILTER DP < 3.0" H,0 LOCALLY (FILTERS B/E)

DISCUSSION:

THIS CONDITION IS INDICATIVE OF EXCESSIVE FLOW THR0llGH THE PURGE EXHAUST FILTERS OR A-DIRTY FILTER CONDITION

]

h,

REFERENCES:

DRAWING 308898 SENSING ELEMENT: AH-586A-DPS, AH-5868-DPS AR-401 Rev. 19 Page 120

ENCLOSURE'1 I

(Page-119 of 183).

'PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F-04-03 i

REACTOR BLDG MISC CLG FANS TRIP EVENT POINT 0360 INDICATED CONDITION:

o AHF-2A MOTOR 'IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION

' s0 -

'y

(

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-2A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP REACTOR CAVITY COOLING T3 "B" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPS ON AH-1003-TIR PER OP-409 DISCUSSION:

- A SUSTAINED LOSS OF CCX) LING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.

l ll

REFERENCES:

DRAWINGS 208-005-AH-031, 308848 L k_,l SENSING ELEMENT:

CS/SC, CS/0, 428 RELAY AR-401 Rev. 19 Page 121

(m, _

ENCLOSURE 1

()

(Page 120 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F-04-03 REACTOR BLDG MISC CLG FANS TRIP EVENT POINT 0362 INDICATED CONDITION:

o AHF-28 MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION

\\

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-28 CONTROL STATION ODERATOR ACTIONS FOR A VALID ALARM:

o SWAP REACTOR CAVITY COOLING TO "A" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPS ON AH-1003-T1R PER OP-409 DISCUSSION:

A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.

4

REFERENCES:

DRAWINGS 208-005-AH-033, 308848

/

SENSING ELEMENT: -CS/SC, CS/0,'42B RELAY

-AR-401'-

Rev.-19 Page 122

. ~.

. ~..

r^

ENCLOSURE 1 (Page 121 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F-04-03 J

REACTOR BLDG MISC CLG FANS TRIP EVENT POINT 0365 4

INDICATED CONDITION:

o AHF-3A MOTOR NOT ENERCIZED WITH THE CONTROL HANDLE IN NCRMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-3A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE AHF-3B IS OPERATING DISCUSSION: IF AHF-3A TRIPS, THERE IS NO IMPACT ON RMA-6 RF.FERENCES:

DRAWINGS 208-005-AH-036, 308848

s /

SENSING ELEMENT: CS/SC, CS/0, 42B RELAY AP-401

.Rev. 19 Page 123

ENCLOSURE 1 AQ (Page 122 of 183)

PSA ANNUNCIATOR RESPONSE-PSA-X-04-03 F-04-03

~

REACTOR BLDG MISC CLG FANC TRIP EVENT POINT 0368 INDICATED CONDITION:

o AHF-38 MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION Ad REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-3B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE AHF-3A IS OPERATING o TRANSFER RMA-6 SUCTION TO RB ATMOSPHERE, REFER TO OP-417 4

DISCUSSION:

RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE VIA EIIliEE THE DUCT OF AHF-3B QB THE R.B. ATFOSPHERE. THE TRANSFER OF THE SAMPLE POINT PER OP-417 IS A MANUAL OPERATION. REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS,

' b,

REFERENCES:

DRAWINGS 208-005-AH-037

'v SENSING ELEMENT: 42B RELAY AR-401 Rev. 19 Page 124'

k' ENCLOSURE 1

()N (Page 123 of 183)

PSA ANNUNCIATOR RESPONSE

-PSA-X-04-03 F-04-03' REACTOR BLDG -

MISC CLG FANS TRIP EVENT POINT 0371 INDICATED CONDITION:

o AHF-4A MOTOR -IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION

^/%

Id REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CREEN LIGHT ON WITH A RED FLAG ON AHF-4A CONTROL STATION OPERATOR ACTIONS'FOR A VALID ALARM:

o START AHF-4B o REFER TO OP-417 DISCUSSION;

REFERENCES:

DRAWINGS 208-005-AH-038, 308848

- () -

SENSING ELEMENT: CS/SC, CS/0, 42B RELAY LAR-401' Rev. 19 Page 125

_.~

ENCLOSURE 1 _

-( )

(Page 124 of 183)

-PSA ANNUNCIATOR ~ RESPONSE PSA-X-04-03 F-04-03 REACTOR BLDG MISC CLG FANS TRIP EVENT POINT 0373 INDICATED CONDITION:

o AHF-4B MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN NORMAL AFTER START POSITION

. r)

(

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

-o CREEN LIGHT J*

WITH A RED FLAG ON AHF-4B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o START AHF-4A o REFER TO OP-417 DISCUSSION:

REFERENCES:

DRAWINGS 208-005-AH-040, 308848 f] -

'v SENSING ELEMENT: CS/SC, CS/0, 42B RELAY

AR-401 Rev. 19 Page 126

,ew w

4

i /~N ENCLOSURE 1

()

(Page 125 of 183)

PSA ANNUNCIATOR RESPONSE

~PSA-X-04 F-04-03 REACTOR BLDG MISC CLG FANS -

TRIP EVENT POINT 0378 INDICATED CONDITION:

o AHF-GA MOTOR IS NOT E 4ERGIZED WITH THE CONTROL HANDLE 'IN NORMAL AFTER START POSITION REDUNDANT INDICATION WhICH WILL VERIFY ALARM:

o GP,EEN LIGHT ON WITH A RED FLAG ON AHF-6A CONTROL STATION o LOSS OF R6 PURGE FLOW AS READ ON AH-32-FIR OPERATOR ACTIONS FOR A VALIC ALARM:

o START AHF-6B o REESTABLISH RB PURGE IF REQUIRED o REFER TO OP-437 P

DISCUSSION:

ONLY ONE PURGE SUPPLY FAN IS REQUIRED FOR' ESTABLISHING AN RB PURGE, SOME OF THE THINGS THAT WILL CAUSE THE PURGE SUPPLY FAN TO TRIP ARE A LOSS OF EITHER OF THE PURGE EXHAUST FANS AHF-7A/AHF-78, ACTUATION OF FIRE ALERT EVENT POINT 0380

REFERENCES:

. DRAWINGS 208-005 SHEETS AH-015, AH-20, DRAWING 308848 SENSING ELEMENT:

CS/SC, CS/0. 42B RELAY AR-401 Rev. 19 Page 127

ENCLOSURE 1

'(]

(Page 126 of 183)

V f

PSA ANNUNCIATOR RESPONSE PSA-X-04-03 F 04,

~

REACTOR BLDG MISC CLG FANS TRIP EVENT POINT 0379 INDICATED CONDITION:

o AHF-6B MOTOR IS NOT ENERGIZED WITH THE CONTROL HANDLE IN-NORMAL AFTER START POSITION rm REDilNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-6B CONTROL STATION o LOSS OF RB PURGE FLOW AS READ ON AH-32-FIR OPERATOR ACTIONS FOR A VALIO ALARM:

o START AHF-6A o REESTABLISH RB PURGE IF REQUIRED o REFER TO OP-417 DISCUSS;0N:

ONLY ONE PURGE SUPPLY FAN IS REQUIRED FOR ESTABLISHING AN RB PURGE, SOME OF THE THINGS THAT WILL CAUSE THE PURCE SUPPLY FAN TO TRIP ARE A LOSS OF q

EITHER OF THE PURGE EXHAUST FANS AHF-7A/AHF-78, ACTUATION OF FIRE ALERT EVENT POINT 0380

REFERENCES:

DRAWINGS 208-005 SHEETS AH-015, AH-21, DRAWING 308848

/

SENSING ELEMENT: CS/SC, CS/0, 428 RELA

l

'\\J AR-401 Rev. 19 Page 128

ENCLOSURE 1

.j (Page 127 of 183)

PSA' ANNUNCIATOR RESo0NSE PSA-X-04-04 F 04 REACTOR BLDG MISC AIR FLOW LOW EVENT POINT 0364 INDICATED CONDITION:

o AHF-2A AND/OR AHF-28 CONTROL HANDLE IN NORMAL AFTEP START AND A LOW DIFF.

PRESS. <0.20" h,0 EXISTS AS SENSED BY AH-10-DPS AND/OR AH-532-DPS REDONDANT INDICATION WHICH WILL VERIFY ALARM:

o CLOSED INDICATION OF AHD-1A o CLOSED INDICATION ON AHD-IB OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP REACTOR CAVITY COOLING PER OP-417 o MONITOR REACTOR CAVITY TEMPERATURES ON AH-1003-TIR PER OP-409 DISCUSSION:

A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY COULD HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.

IF FLOW CANNOT!BE RESTORED THEN CONSIDERATION SHOULD BE GIVEN TO SHUTTING DOWN THE PLANT.

REFERENCES:

DRAWINGS 208-005 SHEET fH-031, ORAWING 308848 L

SENSING ELEMENT: CS/SC, CS/0, 42B RELAY, AH-10-DPS,.\\H-532-DPS AR-40I~

Rev. 19 Page 129

ENCLOSURE 1 i

(Page 128 of 183)-

%J-PSA ANNUNCIATOR RESPONSE.

PSA-X-04-04 F-04-04 REACTOR BLDG MISC AIR FLOW-LOW.

I EVENT POINT 0366 INDICATED CONDITION:

o AHF-3A CONTROL = HANDLE IN NORMAL AFTER START AND A LOW DIFFERENTIAL PRESSURE <0.25" H,0 EXISTS AS SENSED BY AH-13-DPS

tG '

V REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

-o INCREASING RB TEMPERATURES OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE AHF-38 IS OPERATING o REFER TO OP-417 o MONITOR RB TEMPS DISCUSSION:

i LOSS OF THIS AIR SUPPLY FAN WILL CAUSE RB TEMPERATURES TO INCREASE IN

-PLACES DUE TO A LACK OF MIXING FLOW.

REFERENCES:

DRAWINGS 208-005 SHEET AH-036, DRAWING 308848

/

\\.

SENSING ELEMENT: CS/SC, CS/0, 428 RELAY, AH-13-DPS

%) ^

AR-401 Rev. 19 Page 130

ENCLOSURE 1 T -

(Page 129 of 183)

'(

-PSA ANNUNCIATOR RESPONSE PSA-X-04-04 F-04-04 REACTOR BLDG MISC AIR FLOW LOW EVENT POINT 0369 INDICATED CONDITION:

o AHF-3B CONTROL HANDLE IN NORMAL AFTER START AND A LOW DIFFERENTIAL PRESSURE <0.25" H,0 EXISTS AS SEN3ED BY AH-15-DPS b

V REDUNDANT INDI TION WHICH WILL VERIFY ALARM:

o INCREASING RB TEMPERATURES OPERATOR ACTIONS FOR A VALID ALARM:

o START AHF-3A o TRANSFER RMA-6 SUCTION TO RB ATMOSPHERE, REFER TO OP-417 DISCUSSION:

RM-A6 MONITORS THE REACTOR BUILDING ATMOSPHERE VIA EITHER THE DUCT OF AHF-3B QR.THE RB ATMOSPHERE. THE TRANSFER OF THE SAMPLE POINT PER OP-417 IS A MANUAL OPERATION. REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

REFERENCES:

DRAWINGS 208-005 SHEET AH-037, DRAWING 308848 SENSING ELEMENT: CS/SC, CS/0, 428 RELAY, AH-13-DPS AR-401 Rev. 19 Page 131

7 's ENCLOSURE 1

()

(Page 130 of 183)

PSA ANNUNCIATOR RESPONSE

--PSA-X-04-04 F-04-04 REACTOR BLDG MISC AIR FLOW LOW f

EVENT POINT 0375 INDICATED CONDITION:

o' AHF-4A OR AHF-48 CONTROL HANDLE IN NORMAL AFTER START AND A LOW DIFFERENTIAL PRESSURE < 0.19" H,0 EXISTS AS SENSED BY AH-7-DPS r%

REDUNDANT INDICATION WHICI WILL VERIFY ALARM:

o INCREASING RB TEMPERATURES OPERATOR ACTIONS FOR A VALID ALARM:

o START AHF-4A OR 4B AS REQUIRED o REFER TO OP-417 o MONITOR RB TEMPS DISCUSSION:

LOSS OF THE SG COOLING FANS WILL CAUSE SOME AREAS OF TI'E RB TO INCREASE DUE TO LACK OF MIXING FLOW.

REFERENCES:

DRAWINGS 208-005 SHEET AH-038, DRAWING 308348

. rw\\

{U SENSING ELEMENT: CS/SC, CS/0, 42B RELAY,'AH-7-DPS AR-401 Rev. 19 Page 132

/N --

ENCLOSURE 1 (f

(Page 131 of 183)

'PSA ANNUNCIATOR RESPONSE-

'PSA-X-04 F-04-05 REACTOR BLDG F/\\N VIBRATION HIGH EVENT POINT 0361 INDICATED CONDITION:

o AH >11-ME HAS ACTUATED DUE TO AHF-2A VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294

.[d

\\

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-2A o SWAP REACTOR CAVITY COOLING TO "B" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPERATURES ON AH-1003-TIR PER OP-409 DISCUSSION:

THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE.IS NO WAY TO MONITOR THE VIBRATION FROM OUTSIDE THE REACTOR BUILDING. THEREFORE IT WILL REQUIRE A-REACTOR BUILDING ENTRY TO INVESTIGATE / REPAIR THE PROBLEM.

A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTE ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.

p;

-lj

REFERENCES:

DRAWING I.08-005 SHEET AH-133 SENSING ELEMENT: AH-11-ME

.AR-401;

.Rev. 19 Page 133

i ENCLOSURE 1

' [T (Page 132 of 183)

(.

PSA ANNUNCIATOR RESPONSE PSA-X 04-05 F-04-05 l

REACTOR BLDG FAN VIBRATION HIGH EVENT POINT 0363 INDICATED CONDITION:

o AH-12-ME HAS ACTUATED DUE i AHF-28 VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294 f(./

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o NONE OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-2B o SWAP REACTOR CAVITY COOLING TO "A" SIDE PER OP-417 o MONITOR REACTOR CAVITY TEMPERATURES ON AH-1003-TIR PER OP-409 DISCUSSION:

THIS CONDITION INDICATES THAT A' VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED.. THERE IS NO WAY TO MONITOR THE VIBRATION FROM C'JTSIDE THE REACTOR BUILDING. THEREFORE IT WILL REQUIRE A REACTOR BUILDING ENTRY TO INVESTIGATE / REPAIR THE PROBLEM.

A SUSTAINED LOSS OF COOLING TO THE REACTOR CAVITY WILL HAVE ADVERSE EFFECTS ON THE RELIABILITY OF THE NUCLEAR INSTRUMENTATION.

REFERENCES:

DRAWING 208-005 SHEET AH-133 SENSING ELEMENT: AH-12-ME AR-401 Rev. 19 Page 134

k t

ENCLOSURE 1-fN

()

-(Page 133 of 183)

I F-04-05 PSA ANNUNCIATOR RESPONSE-PSA-X-04-05 REACTOR BLDG s

FAN VfBRATION HIGH I

EVENT POINT 0367 INDICATED CONDITION:

o AH-14-ME HAS ACTUATED DUE TO AHF-3A VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294 i

)

'V REDUNDANT INDICATION WHICH WT.LL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-3A o ENSURE Alif-3B IS IN OPERATION DISCUSSION:

THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE IS NO WAY TO MONITOR THE VIBRATIO4 FROM OUTSIDE THE REACTOR BUILDING, THEREFORE IT WILL REQUIRE A-REACTGR BUILDING ENTRY-TO INVESTIGATE / REPAIR THE PROBLEM.

(]

REFERENCES:

DRAWING.208-005 SHEET AH-I33 SENSING ELEMENT:

AH-14-ME' AR-401' Rev. 19 Page 135

.g

('N, ENCLOSURE 1 (Page 134 of 183)--

V PSA ANNUNCIATOR RESPONSE-PSA-X-04 F-04 REACTOR BLDG FAN VIBRATION HIGH I

EVENT POINT 0370 INDICATED CONDITION:

o AH-16-ME-HAS ACTUATED DUE TO AHF-3B VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-3B o START AHF-3A o TRANSFER RMA u SUCTION TO RB ATMG3PHERE, REFER TO OP-417

/

DISCUSSION:

THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE IS NO WAY TO MONITOR THE VICRATION FROM OUTSIDE THE REACTOR BUILDING THEREFORE IT WILL REQUIRE A REACTOR BUILDING ENTRY TO INVESTIGATE / REPAIR.THE PROBLEM.

.(.,)

'i

REFERENCES:

OkAWING 208-005 SHEET AH-134 w_

SENSING ELEMENT: AH-16-ME AR-401 Rev. 19 Page 136-

ENCLOSlEE_1 f~]

(f (Page 135 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-04-OS F-04-05:

REACTOR BLDG -

FAN VlBRATION' HIGH EVENT POINT 0372-INDICATED CONDITION:

o AH-8-ME HAS ACTUATED DUE TO AHF-4A VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294

(]

L REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-4A o START AHF-4B DISCUSSION:

THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEEN DETECTED. THERE IS NO WA) 'O MONITOR THE VIBRATION FROM OUTSIDE THE REACTOR BUILDING, THEREFOR".; IT WILL REQUIRE A REACTOR BUILDING ENTRY TO INVESTICATE/ REPAIR THE PROBLEM.

REFERENCES:

DRAWING 208-005 SHEET AH-134 SENSING-ELEMENT: AH-8-ME

- (_e AR-4013 Rev. 19 Page.137

~.

O LMCLO5URE 1

}

(Page 136 of 183)

[

l PSA ANNUNCIATOR RESPONSE PSA-X-04-05 F-04-05 I

I REACTOR BLDG FAN VfBRATION HIGH i

EVENT POINT 0374 INDICATED CONDITION:

o AH-9-ME HAS ACTUATED DUE TO AHF-4B VIBRATION IN EXCESS OF SETPOINT AS DETERMINED BY PM-294 REDUNDANT. INDICATION WHICH WILL VERIFY ALARM:

d OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-48 o START AHF-4A DISCUSSION:

THIS CONDITION INDICATES THAT A VIBRATION IN EXCESS OF 1.0 G HAS BEF.N DET'CTED. THERE IS NO WAY-TO MONITOR THE VIBRATION FROM OUTSIDE THE REACTOR BUILDING THEREFORE IT WILL REQUIRE A REACTOR CUILDING ENTRY TO INVESTIGATE / REPAIR THE PROBLEM.

REFERENCES:

' DRAWING 208-005 SHEET AH-134 SENSING ELEMENT: AH-9-ME g

.k, s

-AR 401~

Rev. 19 Page 138 i

9

CT EliCLOSUAE_1 V

(Page 137 of 183)

PSA ANNUNCIATOR RESPONSE P3A-X-04-07 F-04-07 I

REACTOR BLDG PURGE AIR FLOW LOW EVENT POINT 0381 INDICATED CONDITION:

o DIFFERENTIAL PRESSURE ACROSS AH-1-DPS IS < 0.048" H 0 WITH AHF-6A AND/OR AHF-6B CONTROL HANDLE IN NORMAL AFTER START iTSITIOk REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHV-ID CLOSES OPERATOR ACTIONS FOR A VALID ALARM:

o DETERMINE THE CAUSE FOR THE LOW PURGE SUPPLY FLOW, AND AD3UST THE RECIRC

" LOW DAMPER CONTROL TO REESTABLISH FLOW THROUGH THE DUCT t

4 DISCUSSION:

- n.

REFERENCES:

DRAWING 208-005 SHEET 20, AND DRAWING 308848 SENSING ELEMENT: AHF-6A CS/SC, CS/0, AHF-6B CS/SC, CS/0, All-1-DPS

-AR-401-

.Rev. 19' Page 139

LRCLOSURE 1 (Page 138 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-04-07 F-04-07 REACTOR BLDG PURGE AIR FLOW LOW EVENT POINT 0386 INDICATED CONDITION:

o DIFFERENTIAL PRESSURE ACROSS AH-296-DPS IS <.0.29" H,0 WITH AHF-7A AND/OR AHF-78 CONTROL HANDLE IN NORMAL AFTER START POSITION O

V REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOW FLOW INDICATION ON AH-32-FIR POINT NUMBER d OPERATOR ACTIONS FOR A VALID ALARM:

o DETERMINE THE CAUSE FOR THE LOW PURCE EXHAUST FLOW, AND CORRECT 1F POSS78LE DISCUSSION:

THIS CONDITION IS INDICATIVE OF A LOSS OF INTEGRITY IN THE DUCT WORK AND SHOULD BE INVESTIGATED AS 500N AS POSSIBLE.

THIS IS AN EXPECTED ALARM DURING RB MINI-PURCE.

IF BOTH FANS OPERATING, ENSURE WINIMUM FLOW (20,000 CFM EACH) IS OBTAINED

REFERENCES:

DRAWING 208-005 SHEET 22, AND DRAWING 308848 SENSING ELEMENT: AHF-7A CS/SC, CS/0, AHF-7B CS/SC, CS/0, AH-296-DPS AR-401 Rev. 19 Page 140

+

es ENCLOSURE 1 l

(Page 139 of 183)-

PSA ANNUNCIATOR RESPONSE PSA-X-04-08 F-04-08 j

l i

I I

r l

CRDM SHROUD -

t I

COOLING FANS I

TRIP am i

EVENT POINT 1224 e

INDICATED CONDITION:

o BREAKER IN UNIT 30 0F VENT MCC 3B IS OPEN o 42/12CR RELAY FOR THIS CIRCUIT IS DE-ENERGIZEP o AHF-51B, AHF-51F, AND AHF-51J ARE NOT. RUNNING REDUNDANT INDICATION WHICH WILL VERI W ALARM:

o CREEN INDICATOR LIGHT ON VENT MCC 3B CUBICLE 3D o LOCAL BREAKER POSITION OPERATOR ACTIONS FOR A VALID ALARM:

o MONITOR CRDM STATOR TEMPS o NOTIFY ELECTRICAL MAINTENANCE 1

DISCUSSION:

THIS ALARM IS INDICATIVE OF AN OVERLOAD CONDITION ON ONE OR MOFE OF THE SHROUD FANS POWERED FROM THIS BREAKER. ELECTRICAL MAINTENANCE WILL DETERM THE FAN (5) THAT ARE SHORTED TO ENABLE THE REMAINING FANS TO BE RUN.

n -

REFERENCES:

DRAWING 208-005 SHEET AH-159 (v)

SENSING ELEMENT: 42/12CR RELAY

ARi401 Rev. 19-Page 141

_ _ - - - - - ~ - = - - -.

f l

f s

[NCLOSURE 1 i

-(Page 140 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-04-08 F-04-08 1

l I

f CRDM SHROUD I

COOLING FANS I

TRIP 3

_l-b x

EVENT POINT 1225 INDICATED CONDITION:

o BREAKER IN UNIT 8A 0F VENT MCC 38 IS OPEN o 42/34CR RELAY FOR THIS CIRCUIT IS DE-ENFRGI7F.D o AHF-51C, AHF-51G, AND AHF-51K ARE NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY-ALARM:

o GREEN INDICATOR LIGHT ON VENT MCC BB CUBICLE 8A o LOCAL BREAKER POSITION OPERATOR ACTIONS FOR A VALID ALARM:

o MONITOR CRDM STATOR TEMPS o NOTIFY ELECTRICAL MAINTENANCE DISCUSSION:

-THIS ALARM 15 INDICATIVE OF AN OVERLOAD CONDITION ON ONE OR MORE OF THE

. SHROUD FANS POWERED FROM THIS BREAKER.

ELECTRICAL MAINTENANCE WILL DETERM THE FAN (5) THAT ARE SHORTED TO ENABLE THE REMAINING FANS TO BE

'tVN,

t

REFERENCES:

DRAWING 208-005 SHEET AH-160 SENSING ELEMENT:

42/34CR RELAY AR-401'.

Rev.'19, Page'142

-n. -.

t O

ENCLOSURE 1 i

(Page 141 of 183)

PSA ANNUNCIATOR RESPONSE PSA-X-04-08 F-04-08 i

l I

l CRDM SHROUD l

COOLING FANS t

I TRIP -

l 2

2 2

EVENT POINT 1226

,e eu.

91 %*MED CONDITION:

c BREAKER IN UNIT 10D OF VENT MCC 3B IS OPEN o 42/42CR RELAY F97 THIS CIRCUIT IS DE-ENERGIZED o AHF-510, AHF-51H, AND AHF-51L ARE NOT RUNNING REDUNDANT INDICATION WHICH WILL VERIFY-ALARM:

o CREEN INDICATOR LIGHT ON VENT MCC 3B CUBICLE 10D o LOCAL BREAKER POSITION OPERATOR ACTIONS FOR A VALID ALARM:

of0NITOR CRDM STATOR TEMPS o NOTIFY ELECTRICAL MAINTENANCE DISCUSSION:

THIS ALARM IS INDICATIVE OF AN OVERLOAD CONDITION ON ONE OR MORE OF THE-SHROUD FANS POWERED FROM THIS BREAKER.

ELECTRICAL MAINTENANCE WILL DETERM THE FAN (S) THAT ARE SHORTED TO ENABLE THE REMAINDER TO BE RUN.

REFERENCES:

DRAWING 208-005 SHEET AH-161 SENSING ELEMENT: 42/42CR RELAY AR-401 Rev. 19 Page 143 i

i ENCLOSEE.1 p,

(Page 142 of 183) i I

PSA ANNUNCIATOR RESPONSE PSA-X-04-08 F-04-08 l

l I

I l

l CRDM SHROUD I

l COOLING FANS I

I TRIP l

l EVENT POINT 1229 INDICATED CONDITION:

o BREAKER IN UNIT 8A 0F VENT MCC 3A IS OPEN o 42/32CR RELAY FOR THIS CIRCUIT IS DE-ENERGIZED o AHF-51A, AHF-51E, AND AHF-51I ARE NOT RUNNING V

REDUNDANT INDICATION WHICH WILL VERIFY-ALARM:

o CREEN INDICATOR LIGHT ON VENT MCC 3A CUBICLE 8A o LOCAL BREAKER POSITION t

OPERATOR ACTIONS FOR A VALID ALARM:

o MONITOR CRDM STATOR TEMPS o NOTIFY ELECTRICAL MAINTENANCE 4

DISCUSSION:

THIS ALARM IS INDICATIVE OF AN OVERLOAD CONDITION ON ONE OR MORE OF THE SHROUD FANS POWERED FROM THIS BREAKER.

ELECTRICAL MAINTENANCE WILL DETERM THE FAN (S) THAT ARE SHORTED TO ENABLE THE REMAINDER TO BE RUN.

REFERENCES:

DRAWING 208-005 SHEET AH-158 SENSING ELEMENT: 42/32 CR RELAY AR-401 Rev. 19 Page 144

n ENCLOSUBi_1

,i (Page 143 of 183)

PSA-F ANNUNCIATOR RESPONSE-PSA-X-05-01 F-05-01 I

I AUX BLDG l

l EXHAUST FAN i

l i

TRIP I

l l

l l

l EVENT POINT 0417 INDICATED CONDITION:

o AHF-14A BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o' GREEN LIGHT ON WITH A RED FLAG ON AHF-14A CONTROL STATION o AHF-10, AHF-11A, AHF-11B TRIP, IF RUNNING OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-14C, START AHF-14B AND AHF-14D PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:

AUX BLDG EXHAUST FILTER DELUGE VALVE ACTUATION, FSV-112 WILL TRIP THIS FAN. THE SUCTION AND DISCHARGE DAMPER POSITION CONTACTS THAT FEED THE FAN RUN INTERLOCK STRING ARE DIFFERENT FROM THE CONTACTS THAT SUPPLY INDICATION ON THE HVAC PANEL, WASTE GAS DECAY TANK OUTLET VALVES, WDV-436, 437, 438 WILL CLOSE WHEN THIS FAN TRIPS..

i

(

)

REFERENCES:

DRAWING 208-005 SHEET AH-01 SENSING ELEMENT: ' CONTROL STATION AND BREAKER CONTACTS AR-401 Rev. 19 Page 145-

4 ENCLOSURE 1

(

(Page 144 of 183) t PSA-F ANNUNCIATOR RESPONSE PSA-X-05-01 F-05-01 1

I AUX BLDG l

l EXHAUST FAN l

l TRIP l

l l

l l

l EVENT POINT 0419 INDICATED CONDITION:

o AHF-14B BREAKER OPEN WITH CONTR0'. HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CREEN LIGHT ON WITH A RED FLAG ON AHF-148 CONTROL STATION o AHF-10, AHF-IIA, AHF-11B TRIP, IF RUNNING OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-14D, START AHF-14A AND AHF-14C PER OP-409 o INVESTICATE CAUSE OF FAN TRIP DISCUSSION:

AUX BLOG EXHAUST FILTER DELUGE VALVE ACTUATION, FSV-110 WILL TRIP THIS FAN. WASTE GAS DECAY TANK OUTLET VALVES, WDV-436, 437, 438 WILL CLOSE WHEN THIS FAN _ TRIPS.

THE SUCTION AND DISCHARGE DAMPER POSITION CONTACTS THAT FEED THE FAN RUN INTERLOCK STRING ARE DIFFERENT FROM THE CONTACTS THAT SUPPLY INDICATION ON THE HVAC PANEL.

REFERENCES:

ORAWING 208-005 SHEET AH-02 SENSING ELEMENT:

CONTROL-STATION AND F,REAKER CONTACTS AR-401 Rev. 19 Page 146

I

. ENCLOSURE 1

/

. (Page 145 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-01 F-05-01 l

I AUX BLDG I

I EXHAUST FAN.

I I

TRIP i

l l

~

-l i

I I

EVENT POINT 0421 INDICATED CONDITION:

o AHF-14C BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION s

REDUNDANT; INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT WITH A RED FLAG ON AHF-14C CONTROL STATION o AHF-11A, AHF-118, AHF-10 TRIP, IF RUNNING OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-14A, START AHF-14B AND AHF-14D o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:

AUX BLDG EXHAUST FILTER DELUGE VALVE ACTUATION -FSV-116 WILL TRIP THIS FAN

THE SUCTION AND DISCHARGE DAMPER POSITION CONTACTS THAT FEED THE FAN RUN INTERLOCK STRING ARE DIFFERENT FROM THE CONTACTS THAT SUPPLY INDICATION ON THE HVAC PANEL.

WASTE CAS-DECAY TANK OUTLET VALVES. WDV-436, 437, 438 WILL CLOSE WHEN THIS FAN TRIPS.

REFERENCES:

. DRAWING 208-00$ SHEET AH-03 SENSING ELEMENT: CONTROL STATION AND BREAKER CONTACTS J

AR-401--

Rev.'19

~

Page 147-

. ~ -.

J i

e

('

ENCLOSURE 1

'y)/

(Page 146 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-01 F-05-01 ZZ l

l AUX BLDG I

I EXHAUST FAN l

I TRIP I

I l

l l

l EVENT POINT 0423 INDICATED CONDITION:

o AHF-14D BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CREEN LIGHT ON WITH A RED FLAG ON AHF-14D CONTROL STATION o AHF-10, AHF-11A, AHF-11B TRIP, IF RUNNING t

OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-148, START AHF-14A AND AHF-14C o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:

i AUX BLOG EXHAUST FILTER DELUCE VALVE ACTUATION, FSV-118 WILL TRIP THIS FAN THE SUCTION AND DISCHARGE DAMPER POSITION CONTACTS THAT FEED THE FAN RUN INTERLOCK STRING ARE'DIFFERENT FROM THE CONTACTS THAT SUPPLY INDICATION ON THE HVAC PANEL.

I WASTE CAS DECAY TANK OUTLET VALVES, WDV-436, 437, 438 WILL CLOSE WHEN THIS FAN TRIPS.

REFERENCES:

DRAWING 208-005 SHEET AH-04 SENSING ELEMENT:

CONTROL STATION AND BREAKER CONTACTS AR-401' Rev. 19 Page 148

1 l

r^

ENCLOSURE 1 i

(

(Page 147 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-02 F-05-02 AUX BLDG EXHAUST FAN OVERLOAD i

~

l EVENT POINT 0418 INDICATED CONDITION:

o AHF-14A MOTOR AMPS >115% RATED LOAD

(

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-14A TRIPS o AHF-14A HIGH MOTOR AMPS INDICATED ON HVAC PANEL OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-14A AND AHF-14C, START AHF-148 AND AHF-14D AND RESTORE AUX BUILDING VENTILATION AS REQUIRED PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:

THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEOUS OVERCURRENT-PROTECTIVE DEVICES HAVE ACTUATED. INSTANTANEOUS OVERCURRENT'

' PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER,

gy

REFERENCES:

DRAWING 208-005 SHEET AH-01

\\f SENSING ELEMENT:- 74-AHF-14A AR-401 Rev. 19 Page 149

c.

l ENCLOSURE 1 f-(Page 148 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-02 F-05-02 l

AUX BLDG EXHAUST FAN OVERLOAD EVENT POINT 0420

'l INDICATED CONDITION:

o AHF-148 MOTOR AMPS >115% RATED LOAD REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-14B TRIPS o AHF-14B HIGH MOTOR AMPS INDICATED ON HVAC PANEL OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-14B AND AHF-14D, START AHF-14A AND AHF-14C AND RESTORE AUX BUILDING VENTILATION AS REQUIRED PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:

THIS ALAFn TNDICATES THAT EITHER THE TIMED OVERCURT OR INSTANTANEOUS OVERCURRENf. PROTECTIVE DEVICES HAVE ACTUATED. -INS".. ANEOUS OVERCURRENT j

PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.

l f

REFERENCES:

DRAWING 208-005 SHEET AH-02

. SENSING ELEMENT:

74-AHF-148

.AR-401 Rev. 19.

Page 150

(

m

ENCLOSURE 1 (Page 149 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-02 F-05-02 i

- i AUXBLDG EXHAUST FAN OVERLOAD EVENT POINT 0422 i

INDICATED CONDITION:

o AHF-14C MOTOR AMPS >115% RATED LOAD bV REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-14C TRIPS o AHF-14C HIGH MOTOR AMPS INDICATED ON HVAC PANEL P

OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-14A AND AHF-14C, START AHF-14B AND AHF-14D AND RESTORE AUX BUILDING VENTILATION AS REQUIRED PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION

INSTANTANEOUS OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.

I -

REFERENC.5:

DRAWING 208-005 SHEET AH-03 p

SENSING ELEMENT:

74-AHF-14C L

AR-401-.

Rev. 19 Page 151 l-

.-....-l

_, _. _ _ _ _ _ _. ~.

LNCLOSURE 1 g

(Page 150 of 183)

PSA-F ANNUNCIATOR RESPONSE P5A-X-05-02 F-05-02 AUX BLDG EXHAUST FAN OVERLOAD i

EVENT POINT 0424 INDICATED CONDITION:

o AHF-14D MOTOR AMP 5 >115% RATED LOAD REDUNDANT INDICATION WHICH'WILL VERIFY ALARM:

o AHF-140 TRIPS o AHF-14D HIGH MOTOR AMP 5 INDICATED ON HVAC PANEL OPERATOR ACTIONS FOR A VALID ALARM:

o SECURE AHF-14B AND AHF-14D, START AHF-14A AND AHF-14C AND RESTORE AUX BUILDING VENTILATION AS REQUIRED PER OP-409 o INVESTIGATE CAUSE OF FAN TRIP DISCUSSION:

THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR INSTANTANEOUS OVERCURRENT PROTECTIVE DEVICES HAVE ACTUATED. INSTANTANEOUS OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.

REFERENCES:

DRAWING 208-005 SHEET AH-04 SENSING ELEMENT:

74-AH F-14 D

'AR-401 Rev. 19 Page 152

i h

ENCLOSURE 1

~

(Page 151 of 183)

PSA-F ANNUNCIATOR RESPONSE.

PSA-X-05-03 F-05-03~

i AB FLTR 2A/8/C/D AP HIGH EVENT POINT 1552 INDICATED CONDITION:

o AUX BUILDING EXHAUST FILTER, AHFL-2A, FLOW 15 >5.2" H,0 AS SENSED BY AH-601-DPS

-AU REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHFL-2A LOCAL DIFFERENTIAL PRESSURE INCICATOR OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIF' HVAC TO INSPECT FILTER DISCUSSION:

OPERATION OF AUXILIARY BUILDING EXHAUST FANS WITH ONLY THREE AUX BUILDING EXHAU5T FILTERS IS PERMITTED.

M

REFERENCES:

DRAWING 208-005 SHEET AH-131

. ~}

SENSING ELEMENT: AH-601-DPS AR-401 Rev. 19 Page 153-

5 ENCLOSURE 1 O

(Page 152 of 183) l PSA-F ANNUNCIATOR RESPONSE PSA-X-05-03 F-05-03 i

AB FLTR 2A/B/C/D i

AF HIGH l

EVENT POINT 1553 INDICATED CONDITION:

o AUX BUILDING EXHAUST FILTER AHFL-2C FLOW IS >5.2" H,0 AS SENSED BY-AH-602-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHFL-28 LOCAL DIFFERENTIAL PRESSURE INDICATOR OPERATOR ACTIONS FOR A VALID ALARM:

o NOTIFY HVAC TO INSPECT FILTER i

DISCUSSION:

OPERATION OF AUXILIARY RUILDING EXHAUST FANS WITH ONLY THREE AUX BUILDING

-EXHAUST FILTERS IS PERU TTED.

i

REFERENCES:

DRAWING 208-005 SHEET AH-131 O.

SENSING ELEMENT:.AH-602-DPS i

AR-401 Rev. 19 Page 154 1

-r>

=,i,-wry-ce--

,y--r-s-m er e-3 rvr-

--**e rwe

+ae-*

n

I ENCLOSURE 1

(~!]3 (Pagi 153 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-03 F-05-03 AB FLTR 2A/B/C/D AP HIGH EVENT POINT 1688 INDICATED CONDITION:

o AUX BUILDING EXtlAUST FILTER, AHFL-2C FLOW 15 >5.2" H,0 AS SENSED BY AH-603-DPS

/^s()

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHFL-2C LOCAL DIFFERENTIAL PRESSURE INDICATOR OPERATOR ACTIONS FOR A V,ALID ALARM:

o NOTIFY HVAC TO INSPECT FILTER.

DISCUSSION:

ODERATION OF AUXILIARY BUILDING EXHAUST FANS WITH ONLY THREE AUX BUILDING EXHAUST FILTERS IS PERMITTED.

REFERENCES:

DRAWING 208-005 SHEET AH-131

()

SEf1 SING ELEMENT: AH-603-DPS AR-401 Rev. 19 Page 155

i ENCLQSURE 1 s

O (Page.154 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-03 F-05-03 AB FLTR 2A/B/C/D AP HIGH EVENT POINT 1689 l

INCICATED CONDITION:

o AUX BUILDING EXHAUST FILTER, AHFL-2D, FLOW 15 >5.2" H,0 AS SENSED BY AH-604-DP5 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHFL-2D LOCAL DIFFERENTIAL PRESSURE INDICATOR 4 -

OPERATOR ACTIONS FOR A VALID ALARM:

-o NOTIFY HVAC TO INSPECT FILTER l

DISCUSSION:

OPERATION OF AUXILIARY BUILDING EXHAUST FANS WITH ONLY THREE AUX BUILDING EXHAUST FILTERS IS PERMITTED.

I R ERENCES:

DRAWING'208-005. SHEET AH-131 (j

ec 1 l

SENSING ELEMENT:-'AH-604-DP5 L

1AR-401 Rev. 19 Page 156 j

f

/^

ENCLOSURE 1 (Page 155 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-04 F-05-04 PENETRATION AIR FLOW TROU8LE EVENT POINT 0438 INDICATED CONDITION:

o PENETRATION COOLING AIR FLOW IS <0.018" H 0 AS SENSED BY AH-30-DPS WITH EITHER AHF-9A OR AHF-98 CONTROL STATION Ib NORMAL AFTER START REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL DIFFERENTIAL FLOW INDICATION OPERATOR ACTIONS FOR A VALID ALARM:

J o START BACKUP PENETRATION COOLING FAN o REFER TO OP-417

'1 DISCUSSION:

REFERENCES:

DRAWINC 208-005 SHEET AH-56 4

[

SENSING ELEMENT: Ah-30-DPS

(

AR-401~.

Rev. 19 Page 157

. = _ _ _ _ -

P

^

p ENCLOSURE 1 (Page 156 of 183)

~

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-05 F-05-05 i

r FIRE PP HOUSE FAN TROUBLE I

f EVENT POINT 0454 INDICATED CONDITION:

o FIRE PUMP HOUSE VENTILATION AIR FLOW IS <0.25" H 0 AS SENSED BY EITHER AH-168-DPS AND AHF-33A IS RUNNING OR BY AH-173-Dh5 AND AHF-338 RUNNING g

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL DIFFERENTIAL FLOW INDICATION OPERAf0R ACTIONS FOR A VALID ALARM:

o START BACKUP FIRE PUMP HOUSE FAN o CHECK FIRE PUMP HOUSE INLET FILTERS AND OUTLET RECIST[ 3 FOR PROPER OPERATION r

DISCUSSION:

FIRE PUMP HOUSE FANS ARE USED FOR FIRE PUMP COOLING AND COMBUSTION AIR FOR DIESEL FIRE PUMPS,

REFERENCES:

DRAWING 208-005 SHEET AH-71 SENSING ELEMENT:: AH-173-DPS, AH-168-DPS AND CONTROL STATION CONTACTS AR-401:

.Rev. 19 Page 158

.2

_ s.,

I 4

i ENCLOSURE 1 f3 Q

(Page 157 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-05 F-05-05 t

FIRE PP HOUSE FAN TROUBLE 4

EVENT POINT 1537 INDICATED CONDITION:

o AHF-33A BREAKER CLOSED AND CONTROL HANDLE IN THE NORMAL AFTER STOP POSITION-rh V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT ON WITH A GREEN FLAG ON AHF-33A CONTROL STATION o TEMPERATURE IN FIRE PUMP HOUSE >85' F.

o ANY FIRE PUMP RUNNING OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIG/TE CAUSE OF AUTO START DISCUSSION:

FIRE PUMP HOUSE FANS ARE USED FOR FIRE PUMP COOLING AND COMBUSTION AIR FOR DIESEL FIRE PUMPS, AT LEAST ONE FAN MUST BE IN OPERATION ANY TIME A FIRE PUMP IS IN OPERATION,

+

REFERENCES:

DRAWING 208-005 SHEET AH-71 SENSING ELEMENT: - CONTROL STATION AND BREAKER CONTACTS

.,,T

/L,i.

AR-401 Rev. Page 159

.w-

^

s P

ENCLOSURE 1 r

j (Page 158 of 183)

'L/

PSA-F ANNUNCIATOR RESPONSE PSA-X-05-05 F-05-05 l

s

?

FIRE PP HOUSE FAN TROUBLE EVENT POINT 1538 INDICATED CONDITION:

o AHF-33B BREAKER CLOSED AND CONTROL HANDLE IN THE NORMAL AFTER STOP POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT ON WITH A GREEN FLAG ON AHF-33B CONTROL STATION o TEMPERATURE IN FIRE PUMP HOUSE >85* F.

o ANY FIRE PUMP LJNNING OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF AUTO START DISCUSSION:

FIRE PUMP HOUSE FANS ARE USED FOR FIRE PUMP COOLING AND COMBUSTION AIR FOR DIESEL FIRE PUMPS AT LEAST ONE FAN MUST BE IN OPERATION ANY TIME A FIRE PUMP IS IN OPERATION.

REFERENCES:

DRAWING 208-005 SHEET AH-72

[]-

SENSING ELEMENT:

CONTROL STATION AND BREAKER CONTACTS

-%s AR-401 Rev. 19 Page 160

ENCLOSURE 1 h

(Page 159 of 183)

NJ PSA-F ANN'JNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE 1

EVENT POINT 0456 INDICATED CONDITION:

o AHF-22A BREAKER OPEN WITH THE CONTROL HANDLE IN NORMAL AFTER START 4

REDUNDANT INDICATION WHICH WILL VERIFY ALAP.M:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-22A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o IF EGDG-1A IS RUNNING ENSURE AHF-228 IS RUNNING o INVESTIGATE CAUSE OF FAN TRIP o REFER TO ITS 3.8.1 & 3.8.2 AND CONTACT NPTS DISCUSSION:

DIESEL GENERATOR FANS WILL TRIP IF DIESEL SPEED IS <810 RPM AS SENSED BY EG-19-SS.

-SECURING THE FAN LOCALLY WILL ACTUATE THIS ALARM.

REFERENCES:

- DRAWING 208-005 SHEET AH-75 A.)

SENSING ELEMENT: ' CONTROL SWITCH CONTACTS AR-401 Rev. 19' Page 161

\\

ENCLOSURE 1 l

(Page 160 of.183)

~

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 j F-06-03 i

DIESEL GEN RM FAN TROUBLE 4

EVENT POINT 0457 INDICATED CONDITION:

o AHF-228 BREAKER OPEN WITH THE CONTROL HANDLE IN NORMAL AFTER START REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-22B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o IF ECDG-1A IS RUNNING ENSURE AHF-22A IS Rl;NNING o INVESTIGATE CAUSE OF FAN TRIP i

o REFE". TO ITS 3.8.1 & 3.8.2 AND CONTACT NPTS DISCUSSION:

DIESEL GENERATOR FANS WILL TRIP IF DIESEL SPEED IS <810 RPM AS SENSED BY EG-19-SS.

SECURING THE FAN LOCALLY WILL ACTUATE THIS ALARM.

REFERENCES:

- DRAWING 208-005 SHEET AH-74

- b SENSING ELEMENT: CONTROL SWITCH CONTACTS' AR.-401-

.Rev..19

-Page 162 5

m.

ENCLOSURE 1 (Page 161 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE EVENT POINT 0458 INDICATED CONDITION:

o CIESEL GENERATOR "A" ROOM DUCT AIR FLOW $0.25" "H20" AS SENSED BY i

AH-3598-DPS WITH AHF-22B OR AH-359A-DPS WITH AHF-22A ON s

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL FLOW INDICATION ON JOHNSON CONTROL PANEL OPERATOR ACTIONS FOR A VALID Al. ARM:

o IF EGDG-1A 15 RUNNING SWAP OPERATING AHF-22 FANS o NOTIFY AUX BLOG OPERATOR TO ENSURE INLET FILTERS ARE CLEAR OF DEBRIS AND OBSTRUCTIONS TO AIR FLOW o REFER TO ITS 3.8.1 & 3.8.2 AND CONTACT NPTS DISCUSSION:

es

REFERENCES:

DRAWING 208-005 SHEET AH-74

. SENSING ELEMENT:

AH-3598-DPS, AH-359A-DPS AR-401' Rev. 19 Page 163

LNCLOSURE 1

,h]

(Page 162 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 B

DIESEL GEN RM FAN TROUBLE EVENT POINT 0459 1

INDICATED CONDITION:

o D'ESEL GENERATOR "A" CONTROL ROOM TEMPERATURE IS >118' F AS SENSED BY AH-540-TS je V

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o HIGH AMBIENT TEMPERATURE CONDITIONS IN THE "A" DIESEL GENERATOR CONTROL ROOM OPERATOR ACTIONS FOR A VALID ALARM:

o INSPECT "A" DIESEL GENERATOR CONTROL ROOM FOR ANY SIGNS OF A FIRE o LOWER TEMPERATURE BY STARTING AHF-22A OR 22B o ENSURE AHF-28A IS RUNNING DISCUSSION:

HIGH AMBIENT TEMPERATURES IN THE CONTROL ROOM CAN ADVERSELY IMPACT THE OPERABILITY OF THE EMERGENCY DIESEL GENERATORS

REFERENCES:

DRAWING-208-005 SHEET AH-76 C/

SENSING ELEMENT: AH-540-TS AR-401 Rev. 19 Page 164

ENCLOSURE 1 q

(,/

(Page 163 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE EVENT POINT 0461 INDICATED CONDITION:

o AHF-22C BREAKER OPEN WITH THE CONTROL HANDLE IN NORMAL AFTER START T

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-22C CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o IF ECDG-1B IS RUNNING ENSURE AHF-22D 15 RUNNING o INVESTICATE CAUSE OF FAN TRIP o' REFER TO ITS 3.8.1 & 3.8.2 AND CONTACT NPTS DISCUSSION:

DIi.SEL GENERATOR FANS WILL TRIP IF DIESEL SPEED IS <810 RPM AS SENSED BY EG-20-55.

SECURING.THE FAN LOCALLY WILL ACTUATE THIS ALARM.

4

REFERENCES:

- DRAWING 208-005 SHEET AH-77 SENSING ELEMENT:- CONTROL SWITCH CONTACTS AR-401 Rev. 19-Page 165

~

ENCLOSURE 1

(

(Page 164 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE EVENT POINT 0462 INDICATEJ CONDITION:

o AHF-22D BREAKER OPEN WITH THE CONTROL HANDLE IN NORMAL AFTER START (O.

.J-REDUNDANT INDICATION VHICH WILL VERIFY ALARM:

o CREEN LIGHT ON WITH A RED FLAG ON AHF-22D CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o IF EGDG-1B IS RUNNING ENSURE AHF-22C IS RUNNING o INVESTIGATE CAUSE OF FAN TRIP o REFER TO ITS 3.8.1 & 3.8.2 AND CONTACT NPTS DISCUSSION:

DIESEL GENERATOR FANS WILL TRIP IF DIESEL SPEED IS <817 RPM AS SENSED BY EG-20-SS.

SECURING THE FAN LOCALLY WILL ACTUATE THIS ALARM.

KaFERENCES:

DRAWING 208-005 SHEET AH-78

(

SENSING ELEMENT:- CONTROL SWITCH CONTACTS AR-401L

_Rev. 19 Page 166 i

4 ENCLOSURE 1 y/.

(Page 165 of 183)

.PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03' DIESEL GEN RM FAN TROUBLE EVENT POINT 0463

. INDICATED COMITION:

o DIESEL CENERATOR "B" ROOM DUCT AIR FLOW <0.25" "H20" AS SENSED BY AH-3698-DPS WITH AHF-22D OR AH-369A-DPS WITH AHF-22C ON-A REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL FLOW INDICATION ON JOHNSON CONTROL PANEL OPERATOR ACTIONS FOR A VALID ALARM:

o IF ECDG-1B IS RUNNING SWAP OiMATING AHF-22 FANS o NOTIFY AUX BLDG OPERATOR TO ENSURE INLET FILTERS ARE CLEAR OF DEBRIS AND OBSTRUCTIONS TO AIR FLOW o REFER TO ITS 3.8.1 & 3.8.2 AND CONTACT NPTS DISCUSSION:

p

REFERENCES:

ORAWING 208-005 SHEET AH-77

\\

SENSING ELEMENT: AH-3698-DPS, AH-369A-DPS 4

AR-401 Rev. 19 Page 167

i y

-fq ENCLOSURE 1

- V (Page_166 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 4

J DIESEL GEN RM FAN TROUBLE 9

EVENT POINT 0464 -

INDICATED CONDITION:

o DIESEL GENERATOR "B" CONTROL' R00M TEMPERATURE IS >118' F AS-SENSED BY AH-$41-TS REDUNDANT INDICATION WHICH WILL VERIFY LARM:

o HIGH AMBIENT TEMPERATURE CONDITIONS IN THE DIESEL GENERATOR CONTROL ROOM OPERATOR ACTIONS FOR A VALID ALARM:

o INSPECT "B" DIESEL GENERATOR CONTROL ROOM FOR ANY SIGNS OF A FIRE o LOWER TEMPERATURE BY STARTING AHF-22C OR 22D o ENSURE AHF-28B IS RUNNING DISCUSSION:

o HIGH AMBIENT TEMPERATURES IN.THE CONTROL ROOM CAN ADVERSELY IMPACT THE OPERABILITY OF THE EMERGENCY DIESEL GENERATORS

REFERENCES:

DPAWING 208-005 SHEET AH-79 SENSING' ELEMENT: AH-541-TS AR-401-Rev. 19 Page 168

~

J ENCLOSURE 1 p

(Page 167 of 183) 4f PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06 DIESEL GEN RM FAN TROUBLE EVENT POINT 1539 INDICATED CONDITION:

o AHF-22A BREAKER CLOSED WITH THE CONTROL HANDLE IN NORMAL AFTER STOP REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT ON WITH A GREEN FLAG ON AHF-22A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

.o INVESTIGATE CAUSE-0F FAN AUTO START o

PL!G CONTROL HANDLE FOR AHF-22A TO NORMAL AFTER START POSITION TO MATCH FLAGS THAT WILL ENABLE THE LOW FLOW ALARM DISCUSSION:

DIESEL GENERATOR FANS WILL AUTO START IF DIESEL SPEED IS >810 RPM AS SENSED BY EG-19-SS.

STARTING THE FAN LOCALLY WILL ACTUATE THIS ALARM.

.r

REFERENCES:

DRAWING 208-D05 SHEET AH-74

(\\

SENSING ELEMENT: CONTROL SWITCH CONTACTS

AR-401 Rev. 19 Page 169

ENCLOSURE 1

-)

(Page 168 of 183)

- x) l PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE EVENT POINT 1540 INDICAT'iD CONDITION:

o EGDG-IA SPEED IS >810 RPM AS SENSED BY EG-19-SS AND AHF-22A AND AHF-228 ARE NOT RUNNING 1

- [(y REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o EGDG-1A READY OR RUN LIGHT ON AND AHF-22A AND AHF-22B GREEN INDICATORS ON OPERATOR ACTIONS FOR A VALID ALARM:

c START AHF-22A AND/OR AHF-228 o REFER TO ITS 3.3.1 & 3.8.2 AND CONTACT NPTS DISCUSSION:'

DIESEL GENERATOR FANS PROVIDE C001.ING FOR THE DIESEL GENERATOR ROOM.

OPERATION OF THE EMERGENCY DIESEL GENERATOR WITH NO COOLING FANS RUNNING MUST BE CLOSELY MONITORED 50 AS TO NOT EXCEED 120F ENGINE ROOM

~ TEMPERATURE.

REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

V)f 4-REFEPENCES:

DRAWING 208-005 SHEET AH-74 SENSING ELEMENT:

3 ERA AND BREAKER CONTACTS AR-401-Rev. 19 Page 170 4

l-

h I

r~

ENCLOSURE 1

(]j (Page 169 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-03 F-06-03 l

DIESEL GEN RM FAN TROUBLE EVENT POINT 1541 INDICATED CONDITION:

o AHF-22B BREAKER CLOSED WITH THE CONTROL HANDLE IN NORMAL AFTER STOP REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT ON WITH A GREEN FLAG ON AHF-22B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF FAN AUTO START o PLACE CONTROL HANDLE FOR AHF-22B TO NORMAL AFTER START POSITION TO MATCH FLAGS THAT WILL ENABLE THE LOW FLOW ALARM DISCUSSION:

DIESEL GENERATOR FANS WILL AUTO START IF DIESEL SPEED IS >810 RPM AS SENSED'BY EG-19-SS.

STARTING THE FAN LOCALLY WILL ACTUATE THIS ALARM.

REFERENCES:

DRAWING 208-005 SHEET AH-75

[m'\\

\\_)

SENSING ELEMENT:

CONTROL SWITCH CONTACTS AR-401 Rev. 19 Page 171

.. =.

ENCLOSURE 1

'i (Page 170 of 183)

PSA-F ANNUNCIATOR RESPONSE =

PSA-X-06-03 F-06-03 DIESEL GEN RM FAN TROUBLE EVENT POINT 1542 INDICATED CONDITION:

o AHF-22C BREAKER CLOSED WITH THE CONTROL HANDLE IN NORMAL AFTER STOP O

. U.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

s o RED LIGHT ON WITH A GREEN FLAG ON AHF-22C CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF FAN AUTO START o

PLACE CONTROL HANDLE FOR AHF-22C TO NORMAL AFTER START POSITION TO MATCH FLAGS THAT WILL ENABLE THE LOW FLOW ALARM i

DISCUSSION.

DIESEL GENERATOR FANS WILL AUTO START IF DIESEL SPEED IS >810 RPM AS SENSED BY EG-20-SS.

STARTING THE FAN LOCALLY WILL ACTUATE THIS ALARM.

A-

REFERENCES:

DRAWING 208-005 SHEET AH-77

. (V)

SENSING ELEMENT: CONTROL SWITCH CONTACTS AR-401.

Rev. 19 Page 172

4 g-ENCLOSURE 1

(

(Page.171 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06 F-06-03 DIESEL GEN RM FAN TROUBLE r

t EVENT POINT 1543 INDICATED CONDITION:

4 o EGDG-1B SPEED IS >810 RPM AS SENSED BY EG-20-SS AND AHF-22C AND AHF-22D ARE NOT RUNNING 1

Asf REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o ECDG-1B READY OR RUN LIGHT ON AND AHF-22C AND AHF-22D GREEN INDICATORS ON OPERATOR ACTIONS FOR A VALID ALARM:

o START AHF-22C AND/OR AHF '.2D o REFER TO ITS 3.8.1 & 3.8.2 AND CONTACT NPTS DISCUSSION:

4 DIESEL GENERATOR FANS PROVIDE COOLING FOR THE DIESEL GENERATOR ROOM.

' OPERATION OF THE EMERGENCY DIESEL GENERATOR WITH NO COOLING FANS RUNNING MUST BE' CLOSELY MONITORED 50 AS NOT TO EXCEED 120F ENGINE ROOM TEMPERATURE.

' REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

-L

REFERENCES:

DRAWING 208-005 SHEE

.F-77 L

SENSING ELEMtNT:

3 ERB AND BREAKER CONTACC AR-401 Rev. 19 Page 173

-g ENCLOSURE 1

(

(Page 172 of 183)

PSA-F ANNUNCIATOR' RESPONSE PSA-X-06-03 F-06 - DIESEL GEN RM FAN

- TROUBLE EVENT POINT 1544 INDICATED CONDITION:-

o AHF-220 BREAKER CLOSED WITH THE CONTROL HANDLE IN ;40RMAL AFTER STOP b

L/

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT ON WITH A GREEN FLAG ON AHF-22D CONTROL STATION OPERATOR-ACTIONS FOR A VALID ALARM:

o INVESTICATE CAUSE OF FAN AUTO START o

PLACE CONTROL HANDLE FOR AHF-22D TO NORMAi. AFTER START POSITION TO MATCH FLAGS THAT WILL ENABLE THE LOW FLOW ALARM DISCUSSION:

-DIESEL GENERATOR FANS WILL AUTO START IF DIESEL SPEED IS >810 RPM AS SENSED BY EG-20-SS.

STARTING THE FAN LOCALLY WILL ACTUATE THIS ALARM.

g-

REFERENCES:

DRAWING'208-005 SHEET AH-78

'C-SENSING ELEMENT: CONTROL SWITCH CONTACTS'

' AR-401-Rev. 19 Page 174

ENCLOSURE 1 y(g) _-

(Page 173 of 183).

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-04 F-06-04 SAMPLING P.OOM FAN TROUBLE EVENT POINT 0508 INDICATED CONDITION:

o AHF-44A BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CREEN LIGHT ON WITH A RED FLAG ON A4F-44A CONTROL STATION o T0XIC CAS ACTUATION o RADIATION HIGH RAD ALARM RM-A5 OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF, FAN TRIP o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION o REFER TO AP-250 OR AP-513 DISCUSSION:

DUCTWORK TEMPERATURE >135* AS SENSED BY AH-402-TS WILL TRIP THIS FAN.

AHF-20A MUST BE RUNNING IN EITHER FAST OR SLOW FOR THIS FAN TO RUN.

t

REFERENCES:

- DRAWING 208-005 SHEET aH-98

'N/

SENSING ELEMENT: CONTROL STATION CONTACTS AR-401

.Rev. 19 Page 175

I

-l ENCLOSURE 1 f]

(Page 174 of 183)

(j PSA-F ANNUNCIATOR RESPONSE PSA-X-06-04 F-06-04 i

SAMPLING F.JOM FAN TROUBLE 4

EVENT POINT 0509 INDICATED CONDITION:

o AHF-448 BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CREEN LIGHT ON WITH A RED FLAG ON AHF 44B CONTROL STATION o TOXIC CAS ACTUATION o RADIATION HIGH RAD ALARM RM-A5 OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF FAN TRIP o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION o REFER TO AP-250 OR AP-513 4

DISCUSSION:

DUCTWORK TEMPERATURE >135* AS SENSED BY AH-545-TS WILL TRIP THIS FAN.

AHF-208 MUST BE RUNNING IN EITHER FAST OR SLOW FOR THIS FAN TO RUN.

7~

REFERENCES:

DRAWING 208-005 SHEET AH-99 SENSING ELEMENT: CONTROL STATION CONTACTS AR-401 Rev. 19 Page 176

4 ENCLOSURE 1

(-

.(

(Page 175 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06 F-06-04 SAMPLING ROOM FAN TROUBLE -

EVENT FOINT 0510 INDICATED CONDITION:

o AHF e4A DUCIWORK TEMPERATURE >I35T AS SENSED BY AH-402-TS

< - f%

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-44A TRIPS o WHITE. " TEMP NORM" LIGHT IS OUT FOR AHF-44A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH TEMP o IF FIRE CONDITIONS EXIST REFER TO AP-880 o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION DISCUSSION:

f

REFERENCES:

DRAWING 208-005' SHEET AH-98 b

SENSING ELEMENT: -AH-402-TS l'

hi-LAR-401 Rev. 19.

Page 177 l

. ~..

- (N

. ENCLOSURE 1

)

(Page 176 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-04 F-06-04 SAMPLING ROOM FAN TROUBLE EVENT POINT 0511 INDICATED CONDITION:

o AHF-44A EXHAUST FLOW <0.10" H,0 AS SENSED BY All-403-DPS v

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOW FLOW ON LOCA; INDICATION FOR Ah/-44A OPERATOR ACTIONS FOR A VALIO ALARM:

o INVESTIGATE CAUSE OF LOW FLOW o CONSIDERATION SHOULD BE GIVEN TO SWAPPING TO "B" SIDE CONTROL COMPLEX VENTILATION o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION DISCUSSION:

AHF-20A MUST BE RUNNING PRIOR TO STARTING AHF-44A

REFERENCES:

DRAWING 208-005 SHEET AH-98 SENSING ELEMENT: AH-403-DPS

_AR-401'-

Rev. 19 Page 178

ENCLOSURE 1 I

(Page 177 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-04 F-06-04 SAMPLING ROOM FAN TROUBLE 1

EVENT POINT 1530 INDICATED CONDITION:

o AHF-44B EXHAUST FLOW <0.10" H,0 AS SENSED BY AH-544-DPS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOW FLOW ON LOCAL INDICATION FOR AHF-44B OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF LOW FLOW o CONSIDERATION SHOULD BE GIVEN TO SWAPPING TO "A" SIDE CONTROL COMPLEX VENTILATION o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION DISCUSSION:

AHF-20B MUST BE RUNNING PRIOR TO STARTING AHF-448

REFERENCES:

DRAWING 208-005 SHEET AH-99 i>

SENSING ELEMENT: AH-544-DPS AR-401 Rev. 19 Page 179

=-.

ENCLOSURE 1 f(4 (Page 178 of 183)

)_

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-04 F-06-04 SAMPLING ROOM FAN TROUBLE 4

EVENT POINT 1531 INDICATED CONDITION:

o AHF-44B DUCTWORK TEMPERATURE >135T AS SENSED BY AH-545-TS O

l'd REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o AHF-44B TRIPS o WHITE " TEMP NORM" LIGHT IS OUT FOR AHF-44B CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF HIGH TEMP o IF FIRE CONDITIONS EXIST REFER TO AP-880 o NOTIFY CHEMISTRY OF LOSS OF SAMPLE HOOD VENTILATION DISCUSSION:

4

,c

REFERENCES:

-DRAWING 208-005 SHEET AH-99 t

J' -

SENSING ELEMENT: AH-545-TS-AR-401 Rev. 19 Page 180

ENCLOSURE 1 f(r*)

(Page 179 of 183) v PSA-F-ANNUNCIATOR RESPONSE PSA-X-06-05 F-06-05 INTERMEDIATE BLDG FAN TROUBLE EVENT POINT 0376 INDICATED CONDITION:

o AHF-24A BREAKER CLOSED AND DISCHARGE DAMPER AHD-67, CLOSED REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL DAMPER INDICATION OPERATOR ACTIONS FOR A VALID' ALARM:

o SHUTDOWN AHF-24A o SWAP TO "B" SIDE INTERMEDIATE BUILDING FANS PER OP-409 DISCUSSION:

OPERATION OF AHF-24A WITH THE DISCHARGE DAMPER CLOSED MAY CAUSE FAN DAMAGE.

REFERENCES:

- DRAWING 208-005 SHEET AH-51 I9 V-SENSING ELEMENT: 2-AHF-24A, AHF-24A-KS AR-401 Rev. 19 Page 181

f ENCLOSURE 1

}

(Page 180 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-05 F-06-05

~

INTERMEDIATE BLDG FAN TROUBLE EVENT POINT 0377 INDICATED CONDITION:

o AHF-24B BREAKER CLOSED AND ITS DISCHARGE DAMPER AHD-68, CLOSED REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL DAMPER INDICATION OPERATOR ACTIONS FOR A VALID ALARM:

o SHUTDOWN AHF-248 o SWAP TO "A" 5IDE INTERMEDIATE BUILDING FANS PCR OP-409 i

DISCUSSION:

' OPERATION OF AHF-248 WITH THE DISCHARGE DAMPER CLOSED MAY CAUSE FAN DAMAGE.

REFERENCES:

DRAWING 208-005 SHEET AH-52 7, s d

SENSING ELEMENT:- 2-AHF-248,-AHF-248-KS

~

AR-401 Rev. 19 Page 182

= _.

j ENCLOSURE i f]

(j

.(Page 181 of 183)-

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-O'; l F-06-05 INTERMEDIATE BLDG FAN TROUBLE EVENT POINT 1548 INDICATED CONDITION:

o AHF-29A BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-29A CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP TO "B" SIDE INTERMEDIATE BUILDING FANS PER OP-409 o INVESTIGATE CAUSE OF FAN -TRIP DISCUSSION:

REFERENCES:

DRAWING 208-005 SHEET AH-53 SENSING ELEMENT: CONTROL STATION CONTACTS

'AR-401'

-Rev. 19 Page 183

f' ENCL 01URE 1

.(

(Page 182 of 183)

PSA-F ANNUNCIATOR RESPONSE PSA-X-06-05 F-06-05 INTERMEDIATE BLDG FAN TROUBLE EVENT POINT 1549 INDICATED CONDITION:-

o AHF-29B BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION

,n

-(j -

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT ON WITH A RED FLAG ON AHF-298 CONTROL STATION OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP TO "A" SIDE INTERMEDIATE BUILDING FANS PER OP-409 o INVESTIGATE CAUSS OF FAN TRIP 07.SCUSSION:

REFERENCES:

DRAWING 208-005 SHEET AH-54

\\ )-

SENSING ELEMENT:

CONTROL STATION CONTACTS AR-401 Rev. 19

-Page 184

ENCLOSURE 1

- ~q f

(

I (Page 183 of 183) y).

.PSA-F ANNUNCIATOR RESPONSE PSA-X-06-08 F-06-08 f

l REACTOR BLDG PERSONNEL DOOR OPEN 4

EVENT POINT 1212 INDICATED CONDITION:

4 o REACTOR BUILDING PERSONNEL OR EQUIPMENT HATCH INNER OR OUTER DOOR NOT CLOSED

/~'i 4

V REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RB DOOR INDICATION PANEL MCB PSA SECTION OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTICATE OPEN HATCH o REFER TO OP-417 f

DISCUSSION:

REFER TO TS FOR ADMINISTRATIVE REQUIREMENTS.

l

REFERENCES:

DRAWING 208-064 SHEET ME-04 j

lu)

SENSING ELEMENT:

ME-1,3,5,7,23,24,25 & 26-KS AR-401 Rev. 19 Page 185 (LAST PACE)