Text

.

Duxn POWER GOMPANY P.O. HOX 33180 CIIARLOTTE, N.C. 28242 IIAL II. TUCKER rutnertown

{704) ON@

VICE PERSLDENT BLELEAR PROmflON June 2, 1988 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

Subject:

RII/PTB Catawba Nuclear Station IE Report 50-413, 414/88-16

Dear Sir:

The subject Inspection Report referenced our commitment to establish a station policy with regard to guidance for reverifying and documenting system status and test pre-requisites for interrupted tests.

We are. incorporating a statement into our Station Directive on testing which provides guidance on the acceptable duration of test interruptions and actions required to re-initiate testing af ter such interruptions.

This revision will be added to a package of other planned revisions which are cur 2ently being reviewed by Station Managemenc for approval.

It is expected that the revised Station Directive will be approved and ready to implement by July 8, 1988.

Very truly yours, A</44 3'4 Hal B. Tucker t~

LTB/02/ bhp cc:

J. Nelson Grace Regional Administrator U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW Suite 2900 Atlanta, GA 30323 P.K. Van Doorn NRC Resident Inspector Catawba Nuclear Station I U 8806100232 880602 PDR ADOCK 05000413 G