r VlltGINI A ELliCTit!C AND l'OWillt COh!!%NY ltien.yoxn, Viuorx:A unu6 June 3, 1988 D. N. Ca t: Dan Vice PanminexT-Ntroena United States Nuclear Regulatory Commission Serial No.88-323 Attention: Document Control Desk PES /ISI Washington, D.C. 20555 Docket Nos. 50-338 License Nos. NPF-4 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 1 SECOND TEN YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN In accordance with 10CFR50.55a(g), Virginia Electric and PWer Company submits the Inservice Inspection Program plan for the second ten year inservice inspection interval for North Anna Unit 1. The plan, which is contained in the enclosed report, addresses inservice examinations of cmnponents and component supports and system pressure tests. The plan for inservice testing of Unit 1 pumps and valves will be submitted at the same time as the Unit 2 second ten year interval Inservice Inspection Program plan in accordance with your letter of April 26, 1988.

The plan has been written in accordance with the requirements of the 1983 Edition of the ASME Code with Addenda through Sumer 1983. However, because the unit was not designed to completely meet the detailed inservice inspection and testing requirements of Section XI of the ASME Code, we are requesting relief from certain inspection and testing requirements wilich have been determined to be impractical. These requests for specific relief from the requirements of the ASME Code are included in the program plan in accordance with 10CFR50.55a(5).

We have evaluated this request in accordance with the criteria in 10 CFR 170.

A check in the amount of $150.00 is enclosed as an application fee.

V ry truly yours, 9 .

.m D. S. C Enclosure North Anna Unit 1 Second Interval Inservice Inspection Program Plan for Components and Component Supports, Revision 0, Match, 1988 d

~) M W/A/GSi  ; 10/

8806100191 eBgggj3g ADOCK PO / check d'9 DR PDR g. gg

l cc: U. S. Nuclear Regulatory Commission 101 Marietta Street, N.W.

Suite 2900 1 Atlanta, GA 30323 l Mr. J. L. Caldwell NRC Senior Resident Inspector North Anna Power Station 1