Safety Evaluation Supporting Util 850924 Proposal Not to Replace Existing Containment Purge & Vent Isolation Valves W/New Clow Valves
ML20197B880
Person / Time
Site: Oyster Creek
Issue date: 10/10/1986
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20197B877 List:
References
NUDOCS 8610310011
Download: ML20197B880 (24)


Text

{{#Wiki_filter:- e ~

  1. "pn an,.\\

UNITED STATES 8 ? NUCLEAR REGULATORY COMMISSION O p WASHINGTON. D. C. 20555 %...../ SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATING TO REPLACEMENT OF CONTAINMENT PURGE AND VENT ISOLATION VALVES GPU NUCLEAR CORPORATION JERSEY CENTRAL POWER AND LIGHT COMPANY OYSTER CREEK NUCLEAR GENERATING STATION DOCKET NO. 50-319

1. 0 Requirement Demonstration of operability of the containment purge and vent valves, particularly the ability of these valves to close during a design basis LOCA accident, is necessary to assure containment isolation.

This demonstration of operability is required by BTP CSB 6-4 and SRP 3.10 for containment purge and vent valves which are not sealed closed during operational conditions 1, 2, 3 and 4. 2.0 Description of Purge and Vent Valves Valve No. (Inches) Location Manufacturer Use V27-1 18 Outside Containment Centerline Drywell Vent V27-2 18 Outside Containment Centerline Drywell Vent V27-3 18 Outside Containment Centerline Drywell Purge V27-4 18 Outside Containment Centerline Drywell Purge V23-13 8 Outside Containment Fisher Drywell Purge V23-14 8 Outside Containment Fisher Drywell Purge V23-15 8 Outside Containment Fisher Torus Purge V23-16 8 Outside Containment Fisher Torus Purge V23-17 12 Outside Containment Fisher Torus Vent V23-18 12 Outside Containment Fisher Torus Vent The containment purge and vent valves are butterfly valves manufactured by Fisher Controls Co. (8-inch and 12-inch valves) and Centerline (18-inch valves). Fisher Model No. 656-60 actuators (air to open, spring to close) are used on both the 8-inch and 12-inch valves. The 18-inch Centerline valves use double-acting actuactors (air to open, air to close) with an accumulator as a fail safe device. Valve opening angles for all valves are limited to 30 open (90* = full open). 3.0 Demonstration of Operability 3.1 GPU Nuclear Corporation (GPUN) has provided operability demonstration information for the purge and vent system isolation valves at their Oyster Creek Nuclear Generating Station in the following submittals: A. GPUN letter dated September 24, 1985 from R. F. Wilson (GPUN) to John A. Zwolinski (NRC) containina TDR #266, Rev. 1. 0610310011 861010 PDR ADOCK 0500 9 P

E. GPUN letter dated June 17, 1986 from R. F. Wilson (GPUN) to John A. Zwolinski containing Colorado State Unisersity Report #179, dated Sectember 1935 (Centerline valves). (Proprietary) C. May 1986 revie of P~ sher test reports for butterfly valve model testing that furnish bases ' ' determination of dynamic torque coefficients. (At Fisher Plant, Marshalltown, Iowa.) D. Summary of April 3,1986 meeting (NRC, JCPL, GPUN) dated June 2,1986. E. Fisher memo dated March 12, 1986 from John Dresser to Kent Rummelhart entitled " Torque Coefficient Basis for Oyster Creek Purge and Vent Valves (QER:86QN21). (Contained in Attachment Z to Reference D.)

  • F.

Telecopy from GPUN to BNL dated April 21, 1986 containing valve numbers and manufacturers.

  • G.

Telecopy from GPUN to SNL dated May 1,1986 containing Centerline actuator closing torque curves and data.

  • H.

Telecopy from GPUN to ENL dated July 7, 1986 containing spring torque availability table for Model No. 656-60 Actuators (Fisher 8" and 12" valves).

  • I.

Telecopy frvm GPUN to BNL dated July 23, 1986 containing revisions to Stress Table 5 (3 pages), part of TDR 266, Re'. No. 2. 3.2 Valve dynamic loads during closure from the 30 limited opening position are determined using dynamic torque coefficients based on model tests of similar butterfly valve discs. Fisher International performed model tests at their Marshalltown, Iowa, facility, from which dynamic torque coef ficients were determined for the 8-inch and 12-inch Oyster Creek valves. Modol tests used in determining dynamic torque coef ficients for the Centerline valves (18-inch) were performed by the liydro-Machinery Lab of Colorado State University, and are described in proprietary Report No. 179 by W. Rehmeyer entitled " Cavitation, Torque, and Performance Testing of a 6-inch and 12 inch Elliptical Disc and a 6-Inch Symmetrical Butterfly Valve Disc." Valve dynamic loads during closure are determined using the valve manufac-turer's torque coef ficients. Fluid velocity and the pressure drop across each valve at a specified disc opening angle between 0 and 30 are generated [ using mass conservation and mcmentum equations. Based on valve torque calculations, the stresses generated at the valve components under combined seismic and LOCA conditions were analyzed using the design rules for Class 1 valves, as detailed in Paragraph NB-3540 of Section III of the ASME Boiler and Pressure Vessel Code. F~ SEE APPENDIX

. 4. 0 Evaluation 4.1 Dyr.amic Torque Coefficients (C ) for the 8-inch, 12-inch and 18-inch 7 containmer' curge and vent valves at Oyster Creer -ere developed from model testing o' similar, smaller test discs. Fisher terr.ational performed tnese r tests at its Marshalltown, Iowa. facility. Tes: - eports describing the model tests and test results were reviewed by the staff and found acceptable at the Fisher plant c-May 28 and 29, 1986. For the 18-inch valves manufactured by Centerline, model testing was performed by the Hydro-Machinery Lab of Colorado State University. Proprietary Hydro-Yachinery Lab Report No. 179 (Ref. B) entitled " Cavitation, Torque and Performance Testing of a 6-inch and 12-inch Elliptical Disc and a 6-Inch Symmetrical Butterfly Valve Disc." The report was reviewed by the staff and found to be acceptable. 4.2 The basis for valve torque determination by GPUN is ANSI /AWA Specifica-tion C504-80. Torque equations from this specification are as follows: 2 T =C D s S 2 T = 4.71 D df Ap b T 0 OP d t 4 T = 3.06 D h where T = seating torque in ft. -lbs. 3 T = bearing torque in ft. -lbs. b T = fluid dynamic torque in ft. -lbs. d T = hydrostatic torque in ft. -lbs. h D = diameter of valve in ft. d = diameter of shaf t in inches ap = pressure drop across valve in psi C = c efficient of seating torque s C = c ef f cient of dynamic torque t f = bearing friction coefficient = 0.25

Safety ' tors of 1.5 and 3 for valve shaft in plane and out of plane with an upstrean. ' bow are used by GPUN in lieu of test data for these configurations. Inlet pressures are based on the DBA containment pressure response curves for dry and wet wells (page 11 of TDR No. 266 - Ref. A). Friction losses at fittings and valves are considered in the analysis. The staff finds the approach used by GPUN in determining valve loads acceptable. 4.3 The stress analysis for valve critical parts by GPUN uses the design rules for Class 1 valves, as described in Paragraph NB-3540 of Section III of the ASME Boiler and Pressure Vessel Code. The analysis is conservative, since the design rules for Class 2 and Class 3 valves are exceeded by those for class 1 valves. Combined seismic and fluid loads are used in the analysis with seismic loads conservatively taken at 1.5 times the specified design loads. Calculated stresses are compared to code allowable stresses, and as shown in reference G, the allowable stresses are not exceeded by the calculated stresses. 4.4 The structural adequacy of the valve operators is demonstrated by comparing the LOCA-induced torques at different disc positions with the design torques for the operators. Table 3 of TDR No. 266 Rev. 1 (Reference A) shows that the operator design torques are not exceeded. References E and F containing Centerline and Fisher actuators closing torque data demonstrate adequate torque margin when compared to the LOCA-induced torques. 4.5 Seismic qualification has not been addressed or referenced in the information submitted. This item must be addressed under the Unresolved Safety Issue A-46, Seismic Qualification of Equipment in Operating Plants. 5.0 Summary The staff has completed review of the information submitted to date concerning operability of the 8-inch, 12-inch and 18-inch valves used in the containment purge and vent system at Oyster Creek. The staff finds that the information submitted adequately demonstrates the ability of the purge and vent valves V-27-1, 2, 3 and 4 (18-inch), V28-17, 18 (12-inch), and V23-13, 14, 15 and 16 (8-inch) to close from the 30 opening position (90 = full open) against the rise in containment pressure in the event of a DBA/LOCA. Seismic qualifica-l tion is to be addresses under USIA-46, Seismic Qualification of Equipment in Operating Plants. l 6.0 References See Section 3.0. i i Principal Contributor (s): J. Lombardo Da ted: October 10, 1986 l l

s 5 APPENDIX REFERENCE F Telecopy from GPUN to BNL dated April 21, 1986, containing valve numbers and manufacturers. 0YSTER CREEK Nu'_' LEAR GENERATING STATION CONTAINMENT VENT AND PURGE VALVES Valve Nos. Manufacturer V-27-1, 2, 3, 4 Centerline V-23-13, 14, 15, 16 Continental Equipment Co. (Which became Continental Division of Fisher) <-28-17, 18 Continental Division of

  • isher Note:

Continental Model Nos. are also Fisher Model Nos. -_. _.. _._-~

6 APPENDIX REFERENCE G Telecopy from GPUN to BNL dated May 1, 1986, containing Centerline actuator closing torque curves and data. Oyster Creek Containment Vent and Purce Valves 1. Provide cross section of valve discs and verify that they are the same as those used in the Fisher test. Fisher provided disc data in 1991 which was confirmed via telecon on 4/11/86. For the 8" valve the diameter is 8" and the maximum thickness is 2", resulting in an aspect ratio of 4:1. For the 12" valve the diameter is 12" and the maximum thickness is 2 3/8", resulting in an aspect ratio is 5:1. Fisher in their memo of March 12, 1986 reconfirmed the aspect ratios anc the fact that the discs (8" is conventional and 12" is fishtail) are considered symmetrical. Fisher also stated in their memo that the 8" test valve had an aspect ratio of 4.57:1, which is similar to the 8" valve, and that the 4" test valve with a fishtail disc had an aspect ratio of 5:1 which is the same as the 12" valve. With respect to the Fisher / Continental valves, verify that the Fisher test report methodology and test data is applicable to these valves. Fisher in their memo of March 12, 1986 referred to Fisher Laboratory Reports as being applicable for both the 8" and 12" valves. Continental was a subsidiary and then a division of Fisher. The model numbers for the valves and actuators are Fisher model numbers. Note: March 12, 1986 memo given to Brockhaven during our meeting in Bethesda on 4/3/86. Provide spring torque vs. valve closure positions. The Centerline valves have double acting actuators (air to open, air to close) with an accumulator as a fail-safe device (added per LER 84-023). Based on a minimum supply air pressure of 60 psig, the available output torques are as follows: Disk Position Output _ Torque 30 (open) 15903 in-lbs 15* (open) 14706 in-lbs 5 (open) 12711 in-lbs 1 (open) 11514 in-lbs 0 (closed) 11286 in-lbs

7 APPENDIX REFERENCE G (Continued) The output torque values are less than those listed in TDR 266 but still result in asailable safety factors above these required by TDR 266. It should be noted that the nominal supply air pressure is 80 psig and this will result in output toroues greater than those in TDR 266 for all disc positions except for 1 open. At 1 open the output torque will be 96% of that shown in the TDR.

8 APPENDIX REFERENCE H Te'ecopy from GPUN tc BNL dated July 7, 1986 containing spring torque avail-atility table for Model No. 656-60 actuators (Fisher 8" and 12" valves). OYSTER CREEK NUCLEAR GENERATING STATION Containment Vent and Purge Valves Spring Torque Availability for 656-60 Actuators Assuming Control Air Vented (Diaphragm Casing Pressure = 0 psig) For 8"~9100 For 8" 9100 For 12" 9500 $/N: 103160-61 S/N: 103162-63 5/N: BF200233-234 0-90 Rotation 0-60 Rotation 0-90 Rotation Valve 4" Actuator Stroke 4" Actuator Stroke 4" Actuator Stroke Position 6-26 psig Air 6-26 psig Air 3-15 psig Air Spring: 1K162827082 Spring: 1K162827082 Spring:1K162727082 (Degrees Open) Spring Closes Spring Closes Spring Closes Degree Torque (in-lb) Torque (in-lb) Torque (in-lb) 0 2322 4022 1161 1 2397 4173 1196 5 2675 4754 1323 15 3250 6060 1587 30 3930 7825 1899 45 4518 9590 c169 60 11629 90 6714 3177 t

9 R REFERENCE I i Telecopy f rom GPUN to BNL July 23, 1986, containing revisions to Stress Table 5 (3 pages) part of TDR 266, Rev. No. 2. 4 a l l. l I i I t L,.--_..--,---.---_

c, y~.,'. 'l.; I..'f.,; w :,- n.. Coc h Q h h d*.b hw Dc U3Ves

n...

' ' \\ '..;.

r o n. m. zic w, no.
a.

l; ,s f

  • i<.s,.g. I e % 3'

, '.. ~.. , 3., '. p,.' , m: 5 - s: m A n ce m ass Amatrsts yvnt U-e oc.,::.:m. w:e;/: j smss - ! c:es Imr. _. I ,,#2nw.ut smzss m

n
' o ce s o omsrom t

, euo a.<c _.aan . _u_s n u m.-

  • o.

o -,h..,..

  • d,-

? i /421 !.ra b. t 9 s } g.. .,[i / ~ v

      • ' 5 2 +

l T.. ol 4 e {-. .,_ ___260u, 2 703Oj Ma 1545.l(a) (1),..,gggg( ) ../ - - P;-i.v.cf pus saxrxkir/ (p k I.,. .s:.., e,

c...

at.resa d e to irte. m i. ,m2 r ,~ uanss.2 tal lu s. 1,... ~ P - j f we, l [ tw_a s. g.. [g s.- lOW Am t.al. , INd f g*h. 4M4 9, Bc(/, {n. A ;' *.;j,,.' rc.httica , Aa 154 5.2 (b) O) -6 7---.- strc a - Le siin; Rb gyg a,* l -. l 16611 .g&,+,.- ;-. ..,; g l na1545.2 th) (1) l,. )'- l l hden Pet 8t 48 33_ 'M;?-2d.f. fwwM45.2(b) ( 18900 ,P ~*7* 3.E '. ! l *Eka 8Iha::m1 acarrdarf I } Ct 444 f

  • p
my, t

M ~ k, [nN Op Nh Y" N E.. l 23d85 72i. arf pla. % p. 6, '], , 1% gg 4.. t th;c.a 'k. .,'. ;.,' - ::U,.::.

C;-ci. n! D m ii.q 5

O r . J. ' L' - /, ' 9.. w.cr.a1 13rar St:ma _ }. (1) .5 m Tec~ s i L;. c.;,'.,... ' S rce s c. tis: cmtaril.ma 2m gg e

gco

} S(9) l 2is6 ~f. $.j. (.'- [, ~~ J 2ini.W ar n re a j :sM) i 2735 l 'tni2/3sy,'/4st) ..s =taht467,1750)l* "N

  • M*I

{['... --' "f,h, Sh.e.t.' C.r.cOmite:W:q ,S(5) I gg3 [ min.2/1 w, AM M

4.,

7[,,,.. J.'. -j t=Ln{26067.175ai,; } unn46.'3 ta) , 6 N.3 p..' '.= ' p ' t:crMral suess . S(4) 7 -- - ~. M' [ s.in-2/3 sy, 1/6 set l ' (stau.Lt a;d LAsditz)) Nd ('a.in 26447, 175GOf ) ,. - O,. . l., 'c.3 :

  • 4

.Y S :.#t J.c*a,. f+ Czc'. Stress Cr) i 'f S (lf.) 4g [ 4.b/3 De * * * ^, .*C -S. '. j Aa'] { ain ('16667,17500[ esa)S46.3(a) } if.- 1

  • 0.1wh+se -

.eci stress iti S(17) ./no I man f7/3 sy,1/4 st) .,g g -[, ,pt:4 - i pi:,,, minpocco,22soo) s (gaft ceari:g}jl. writs stress in - n.d.wp i., c., , g', q .G t21) i 1217 lnmressive alwue*

  • *.. ~

Ix.:r.1:>3s '40'4 p. . '/ *,, i l Opcr4*.is".- l '!'tfr.jJ:n M Idt3 E S!$43 1510 "Lak#/3 D I/* 8N r,64 ' * - . p. -.' c* .n. g.1:9 +st%) miaOnco '175cc) sa1546. 3 (a) .c: .,, i ,'..".i.i. ,.s .[* I S(57) 24n I",jd2fi g ggty _j,;,34,,,3g,, . g, o .y

e

. m.. N e. 3 f,. f.,.'. k..au.'sh ~ ~i.? f hN e. ~ p

  • i q'.:l

. ;..~ z. p r..> /.? W '7 .,1. 1 .s .. -. w*t. -*,,.f g .s. e

y l '} ' (o Y O b & 4. Eu y K Q ~ .. 3 g. " - c[ T O A 90 24 G Rev As,. 2. d. y.. . -f.. o o 'g.7. f y,' 9 <. 2 or-3 AI .g , v.. l% ~ 4 1 ' ' ' ^ ^ ' *t,3:L $ ' Cmt.M: s . A .' \\M'C. I WE AC %.YZ- -I (l'SI) I. 5

  • . V3' lS~'. d l

S"C'S IDE. I M 11AW4 SIMES peu Asms t x t orvg s tog 1 C<1.JP COXtCC ' (PSI) PAPE?Q% ,Pf rirrf Arranc .. l Pm l

stafh, j

f ulub1(a)(1), an1524 f 0.95Y ) 1%O ,,.,.y i ~ p 1 an3JM tal

  • g, fs?:.../phsueurd.h:y 4 Cp

{ g5 t.cm,.:e sa,e w :r,tenal ulu s.2 (a) (1)

  • f-

,g { pec.:; :e l _n--. I pips Ane; } Wc J32G l15 * . hals45.2 a) ( O .:.] g.. J.;' \\ mu t .N ~:- : a. sm st.rss IA.' Uq 4M l Q'f le3%s.2m.)n) .. +[ '.'s..*4-47 6 ! 2 gnn r pet j 7211 L.s a 4 +

?MM '
8.,,

WQ 8'B35'b2 (b) Li ' t,1,.. .1 -.- lu; beccM:.:y l \\, Oc w

u

~ m3 ..w.. - wa3us.2 e.

,s t

4 r. I !Prinryplus Sn I 11237 1m m).c%2 . j( 7 t ua eq nu. a paao ..:e m,.s.) ii! e . b.. . 2w

C.cLirei Berdv.3 SIlI

'm 1.5 r.a 5 St.reas ca di.x ca.atarlina g xalu6.2 (' .-C ,ssc g s "I. ; b.4 M_$Edl.Mf.EW87 ' SISI l $H

  1. 4 #"I i

I" ' #/ 3 S Y w "in {61u7,'1 sumo) f mM4 7 Cr.cui St v.c stless. . s?4 l. 6u .j-m r

a.

s 7

  • )

l, ' St.Lft' Ocrti xxi berk 11r4, i S(5) l 49.2 min 2/1 sy,1/4'.1t} ) wn)M.)(a)

  • ;M:
a. -

ums t , ~. . um 3 u C m.% r.txuss ' 5!41 l min {2/1 sy,1/4 st) ! reiv.u.i d., s. - l# -' l c/- i p4 J.,1to dary,. ) ,, L..g,61467, be,noj , us%C.2 i '.',p', ,. s Shaft Key E. aw s:.rcss cm S!Ni miaNI O' d u1%6.3 (a) ..Id gg44 ,{ - ).cy man {66M7, 18 75o} .1 s - g l *.ill7J min {2/3 sy,1/4 dej I t- ,Olu: t;qpe:r. . S e.Lr'heress it. i.

y....

.n n

pirs ;

i l 19 m min {o m, n.,o1 '- f "' 2"' ' ' '* 3 s 4. 1 ;f e-i . a r.p l M r my stress in. f 9,a - 0 eg ressive al.1pl e* lS(21) 6 7 - _ ;,- gi:g{ : a.,hltys ,10003 .P ' l ,.y ~ ! 'lbv 4m in toit.s - !S('4) It.135 ! *Ia',2/3 a y, 1/4 St) u154.3 (a) ';,* ', ?q, , 7 , J..I ' ,j - Cpc :4 ;;r

  • %.,,,, -~ )cre,c.;.gq

.t ~ l +M 55) 'a- ? OOO, IM%Y '~t ,g,;.., Ah.r,aba to l S(07) 106 % "lat2/1 s y, 1/g utj ,ugg,yg,3 ',j[. I g.* - *ior,:ue a rolt.s f minfWh h LM '.n l i 4 , ?,e., s.'*. c " . s '. *,. s... 'p#

  • 5

'*J

  • g" y, '
  • ##47aI4 Ace,6.5

,., ~.. - I' - J ; ;, <' ', , : =.,.g.,, i' 4!r. 9 ',

s i,. -

w,.

&;.... y-...,

.4

  • n-9 hd

CO&% &h-t%'f N f &a$ I ~~ ,. I bpe 3 Gb 3 mate s'scont a.) DR C+. "Zl.,4. hv. 4<2 . c w:.:, we j.m r.m . wm ir.u. i auama: cms {s i., - m omm > . - cxw N cxcar 1 va::.c s w t. gen c_s n - ois4s.u.u n. w m 4.. w. .e. . '3 i q

reira y m r.m j

i . m p. o. o. .a.,,, o. s Ds us4 r !m t =a. :i4sm. v4 ~~ y: s' .u22.i.i 8 w. m n i s a s< m i w ..n v 6trces d,a to it.Ler.ul A. 27

manes.2(=3 0)
  • a:

' 14',0c - r. a:.. pcc.: s.s.re ~ s '.,..t. j we. emum { ^e k??. I,ous.2 o,) m E .Sj G jaw- .1 ui=1 - .v... >.. ,[* l m)us.2(b)(1) ..w,,..'. ! at.:ess T.wcdity l a~to i l ll 5 % l unses.2(b)(U b; ;.':.. p_-L14.,Y; {__ ___{._. ors i.2:s l Pet i 16440

v
u.:.s, m,

mma 4;- 4V,2 M 6),"f / l W:m t *,m~.fary 419 ns CL .' M, Stress 14 % o mus45.2 p . C "" II ' Prunef ph.s Es. 25629 3 nn (uns45.2 L 'E - O-saxe.darf s:cesa

4 l',G0 l

' 9 ;'. q.M... q..~.hi, trees on ese cose:-une kl . j f,P  ;,'. ,ciac crtairai s::erfing ls(1) } mam.2nnm.nei us2 't.s s. .,{ v.,,y.;, ;a, , 2nse 'Tk-' l t.- .1 ar.sur Stn:ss ! 5!9: } 5271 i.kn {2/3 sy. 1/4st} ., j. ',- \\,$ ~ .. ~. ["E,cavursuces g m,) j ini2u23 is7se; I **

  • 3

'_ 6f,:

/,.

,,.( it. r--- sm if

?. s.9.c...

v.au. , - j s(5) .t[{2/3 sy, 1/4stj i [.*. ' c::nc4.ed bcrding .'(, ). g,- + g ,1 . l =ao nn,,rus 1 usa.u.) w yk - i .G.g;...g(..,.

  • tGT Sftesh S(4) 1A(2/3sy, 1/4St)

,,v.cc an1 txrdirg) essa EMsM.3 f e) C - E .. k r.tnpim. la?sc} / ..q y / s. : .~.:-i n c.: n r m cra c a:z ~ en i sus) =snian er su sti ,i. u.. *'.3- ,u, .mm. u, 5 +: uf .u pu67, ta7so) ~ -l_ .. - s 'n' .x , p. , y

.i.copsi i s..u st.:ess in

.s(17 1 .inf2n sr.1/4 Sti ! maisis.3(.)

] 'Y, ' -.

1un2 p s .n. c p u I pi.n 3 .intanu,saww]

  • *;:.; 3.,.

S(21) 64 & rsaswas&ve alwa ,Q . _ ~ _ b g,'d.a*'$ M *.'nu m isp,

  • 71 '-f.r.' NW

':.uf t tearfrg)t *emel.N r,tzesa in.. .l N g. j.', M, y ~,

.Aise.inp it y f,.-

': . ? ? A.. ,,y.c = .:.y.su,3 m rat, ' scs42 t r.4ns =ta ten er. to st) a nses. m > l ': = 7,q q x e.u:4 ~ .scss .w3,wi,1873oj c 7 ') ,D.~.[,...h '.' ' I*W.( 6.8 to 'SN[ i *I"I#U 8Y* I/* 8' I W81546. 3 (a) i 1342s ~.M timw m tn1ts .,l 'q f..A. _.inosooo. leisoj ,j. ~ . Q., I

1. c.:.

y ~ , 9..,,. . /... .'^ ,..M f h eder.ca 4.5 ' ' ~. '...'y**

  • 9 y-

'. e.. .g).,- s ,'..i -;g: - ,.y,;,,. 3..g

  • s f'.h ^

.r. p,~ v , ~.z- :. '.C. .s- ~ s. e - .y.-. ...s.. . ~. <w

v. __...c.a. m.z ~._ m.m k UfflTED STATES t NUCLEAR REGULATORY COMMISSION

B I

wasumarow, n.c. massa \\o / ooo* SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATING TO REPLACEMENT OF CONTAINMENT PURGE AND VENT ISOLATION VALVES GPU NUCLEAR CORPORATION JERSEY CENTRAL POWER AND LIGHT COMPANY OYSTER CREEK NUCLEAR GENERATING STATION DOCKET NO. 50-219

1. 0 Requirement Demonstration of operability of the containment purge and vent valves, particularly the ability of these valves to close during a design basis LOCA accident, is necessary to assure containment isolation.

This demonstration of cpirability is required by BTP CSB 6-4 and SRP 3.10 for containment purge and vent valves which are not sealed closed during operational conditions 1,.2, 3 and 4. 2.0 Description of Purge and Vent Valves Valve No. (Inches) Location Manufacturer Use V27-1 18 Outside Containment Centerline Drywell Vent V27-2 18 Outside Containment Centerline Drywell Vent V27-3 18 Outside Containment Centerline Drywell Purge V27-4 18 Outside Containment Centerline Drywell Purge V23-13 8 Outside Containment Fisher Drywell Purge V23-14 8 Outside Containment Fisher Drywell Purge V23-15 8 Outside Containment Fisher Torus Purge V23-16 8 Outside Containment Fisher Torus Purge V23-17 12 Outside Containment Fisher Torus Vent V23-18 12 Outside Containment Fisher Torus Vent Th2 containment purge and vent valves are butterfly valves manufactured by Fisher Controls Co. (8-inch and 12-inch valves) and Centerline (18-inch valves). Fisher Model No. 656-60 actuators (air to open, spring to close) are used on both the 8-inch and 12-inch valves. The 18-inch Centerline valves use d2uble-acting actuactors (air to open, air to close) with an accumulator as a fall safe device. Valve opening angles for all valves are limited to 30* open (90* = full open). 3.0 Demonstration of Operability 3.1 GPU Nuclear Corporation (GPUN) has provided operability demonstration information for the purge and vent system isolation valves at their Oyster Cr ek Nuclear Generating Station in the following submittals: A. GPUN letter dated September 24, 1985 from R. F. Wilson (GPUN) to John A. Zwolinski (NRC) containing TDR #266, Rev. 1.

[0ff.. q:.as;;;.:.= n&&'~='* ='"='

  • W ' +Wf'M-'+

N& ' %:.=. = v ~" . B. GPUN letter dated June 17, 1986 from R. F. Wilson (GPUN) to John A. Zwolinski containing Colorado State University Report #179, dated Septembir 1985 (Centerline valves). (Proprietary) ~ C. May 1986 review of Psher test reports for butterfly valve model testing that furnish bases 'w* determination of dynamic torque coefficients. (At Fisner Plant, Marshalltown, Iowa.) D. Summary of April 3,1986 meeting (NRC, JCPL, GPUN) dated June 2,1986. E. Fisher memo dated March 12, 1986 from John Dresser to Kent Rummelhart entitled " Torque Coefficient Basis for Oyster Creek Purge and Vent Valves (QER:86QN21). (Contained in Attachment Z to Reference D.)

  • F.

Telecopy from GPUN to BNL dated April 21, 1986 containing valve numbers and manufacturers.

  • G.

Telecopy from GPUN to BNL dated May 1,1986 containing Centerline actuator closing torque curves and data.

  • H.

Telecopy from GPUN to BNL dated July 7, 1986 containing spring torque availability table for Model No. 656-60 Actuators (Fisher 8" and 12" valves).

  • I.

Telecopy from GPUN to BNL dated July 23, 1986 containing revisions to Stress Table 5 (3 pages), part of TDR 266, Rev. No. 2. 3.2 Valve dynamic loads during closure from the 30* limited opening position are determined using dynamic torque coefficients based on model tests of similar butterfly valve discs. Fisher International performed model tests at their Marshalltown, Iowa, facility, from which dynamic torque coefficients were determined for the 8-inch and 12-inch Oyster Creek valves. Model tests used in determining dynamic torque coefficients for the Centerline valves (18-inch) were performed by the Hydro-Machinery Lab of Colorado State University, and are described in proprietary Report No. 179 by W. Rehmeyer entitled " Cavitation, Torque, and Performance Testing of a'6-inch and 12 inch Elliptical Disc and a 6-Inch Symmetrical Butterfly Valve Disc." Valve dynamic loads during closure are determined using the valve manufac-turer's torque coefficients. Fluid velocity and the pressure drop across each valve at a specified disc opening angle between 0 and 30* are generated using mass conservation and momentum equations. Based on valve torque calculations, the stresses generated at the valve components under combined seismic and LOCA conditions were analyzed using the design rules for Class 1 valves, as detailed in Paragraph NB-3540 of Section III of thi ASME Boiler and Pressure Vessel Code. w*

  • SEE APPENDIX

~ i l l

,.Li'i.J.,.Z5uCOC72 MN~ ''2f E*'**"~'"'**t W'" CC!~~ 4.0 Evaluation 4.1 Dynamic [TorqueCoefficients(C)forthe8-inch,12-inchand18-inch 7 containme.: purge and vent valves at Oyster Cree ere developed from model testing osimilar, smaller test discs. Fisher ternational performed these tests at its Marshalltown, Iowa, facility. Test eports describing the model tests and test results were reviewed by the staff and found acceptable at the Fisher plant c-May 28 ano 29, 1986. For the 18-inch valves manufactured by Centerline, model testing was performed by the Hydro-Machinery Lab of Colorado State University. Proprietary Hydro-Machinery Lab Report No.179 (Ref. B) entitled " Cavitation, Torque and Performance Testing of a 6-inch and 12-inch Elliptical Disc and a 6-Inch Symmetrical Butterfly Valve Disc." The report was reviewed by the staff and found to be acceptable. 4.2 The basis for valve torque determination by GPUN is ANSI /AWA Specifica-tion C504-80. Torque equations from this specification are as follows: 2 D T, = C3 2 T = 4.71 D df Ap b 3 Td"Ut D 3p 4 Th = 3.06 D where T, = seating torque in ft. -lbs. T = bearing torque in ft. -lbs. b T = fluid dynamic torque in ft. -lbs. d Th = hydrostatic torque in ft. -lbs. D = diameter of valve in ft. d = diameter of shaft in inches op = pressure drop across valve in psi C, = coefficient of seating torque C = coefficient of dynamic torque t f = bearing friction coefficient = 0.25

[.i _: _A._.15U "7-AN1 "" N'$.c c b i - f -GA: . Safety factors of 1.5 and 3 for valve shaft in plane and out of plane with an upstream elbow-are used by GPUN in lieu of test data for these configurations. Inlet pressures are based on the DBA containment pressure response curves for dry and wet. wells (page 11 of TDR No. 266 - Ref. A). Friction losses at fittings and valves are considered in the analysis. The staff finds the approach used by GPUN in determining valve loads ccceptable. 4.3 The stress analysis for. valve critical parts by GPUN uses the design rules for Class 1 valves, as described in Paragraph NB-3540 of Section III of th2 ASME Boiler and Pressure Vessel Code. The analysis is conservative, since the ' design rules for Class 2 and Class 3 valves are exceeded by those for class 1 valves. Combined seismic and fluid loads are used in the analysis with seismic loads conservatively taken at 1.5 times the specified design loads. Calculated stresses are compared to code allowable stresses, and as shown in reference G, the allowable stresses are not exceeded by the calculated stresses. 4.4 The structural adequacy of the valve operators is demonstrated by comparing the LOCA-induced torques at different disc positions with the design torques for the operators. Table 3 of TDR No. 266 Rev.1 (Reference A) shows that the operator design torques are not exceeded. References E and F containing Centerline and Fisher actuators closing torque data demonstrate adequate torque margin when compared to the LOCA-induced torques. 4.5 Seismic qualification has not been addressed or referenced in the information submitted. This item must be addressed under the Unresolved Safety Issue A-46, Seismic Qualification of Equipment in Operating Plants. 5.0 Summary The staff has completed review of the information submitted to date concerning operability of the 8-inch, 12-inch and 18-inch valves used in the containment purge and vent system at Oyster Creek. The staff finds that the information submitted adequately demonstrates the ability of the purgeiand vent valves V-27-1, 2, 3 and 4 (18-inch), V28-17, 18 (12-inch), and V23-13, 14, 15 and 16 (8-inch) to close from the 30' opening position (90* = full open) against the i rise in containment pressure in the event of a DBA/LOCA. Seismic qualifica-tion is to be addresses under USIA-46, Seismic Qualification of Equipment in Operating Plants. i 6.0 References i See Section 3.0. { i Principal Contributor (s): J. Lombardo ~ Dated: October 10, 1986 ' ~ -~-

.2; ,..- - a - ~ ~-- - = 5 APPENDIX s REFERENCE F + ~ Telecopy from GPUN to BNL dated April 21, 1986, containing valve numbers and manufacturers. 0YSTER CREEK Nu' LEAR GENERATING STATION CONTAINMENT VENT AND PURGE VALVES Valve Nos. Manufacturer V-27-1, 2, 3, 4 Centerline V-23-13, 14, 15, 16 Continental Equipment Co. (Which became Continental Division of Fisher) V-28-17, 18 Continental Division of Fisher Note: Continental Model Nos. are also Fisher Model Nos. i i a ; we 6

l':. ..:.::..~.ni:.*:: a*:^.^2MlMWWTM^f %F ~~~^='C.~^ 6 APPENDIX REFERENCE G + e Telecopy from GPUN to BNL dated May 1,1986, containing Centerline actuator closing torque curves and data. Oyster Creek Containment Vent and Purce Valves 1. Provide crcss section of valve discs and verify that they are the same as those used in the Fisher test. Fisher provided disc data in 1981 which was confirmed via teleton on 4/11/86. For the 8" valve the diameter is 8" and the maximum thickness is 2", resulting in an aspect ratio of 4:1. For the 12" valve the diameter is 12" and the maximum thickness is 2 3/8", resulting in an aspect ratio is 5:1. Fisher in their memo of March 12, 1986 reconfirmed the aspect ratios ana the fact that the discs (8" is conventional and 12" is fishtail) are considered symmetrical. Fisher also stated in their memo that the 8" test valve had an aspect ratio of 4.57:1, which is similar to the 8" valve, and that the 4" test valve with a fishtail disc had an aspect ratio of 5:1 which is the same as the 12" valve. With respect to the Fisher / Continental valves, verify that the Fisher test report methodology and test data is applicable to these valves. Fisher in their memo of March 12, 1986 referfed to Fisher Laboratory Reports as being applicable for both the 8" and 12" valves. Continental was a subsidiary and then a division of Fisher. The model numbers for the valves and actuators are Fisher model numbers. Note: March 12, 1986 memo given to Brookhaven during our meeting in Bethesda on 4/3/86. 1 Provide spring torque vs. valve closure positions. The Centerline valves have nouble acting actuators (air to open, air to close) with an accumulator os a fail-safe device (added per LER 84-023). Based on a minimum supply air pressure of 60 psig, the available output torques are as follows: Disk Position Output Torque 30* (open) 15903 in-lbs JS* (open) 14706 in-lbs a 5* (open) 12711 in-lbs 1* (open) 11514 in-lbs 0* (closed) 11286 in-lbs ~

[ CI.~_'_.;r.ia:o7O 2dC5 C_r*E O N iN"b~lN 5 dif.).uad " ~ O'N?"'59 Y N "~~~"' } 7 APPENDIX REFERENCE G (Continued) t 3 Tho output torque values are less than those listed in TDR 266 but still result in available safety factors above those required by TDR 266. It should be noted that the nominal supply air pressure is 80 psig and this wil.1 result in output torques greater than those in TDR 266 for all disc positions except for l' open. At 1* open the output torque will be 96% of that shown in the TDR. 9 p. .,m-,... _. -. ,,-__.~,_.--.,,..___-.,-..,-.,m.

V"2..:.d.M.Cu'.l"nM2= tt'W"'m' i 'e== *= rr=Lr.::'"*"~"'~"~&***~.::= ^ ~ 8 APPENDIX REFERENCE H Telecopy f~ro'm GPUN to BNL dated July 7,1986 containing spring torque avail-atility table for Model No. 656-60 actuators (Fisher 8" and 12" valves). OYSTER CREEK NUCLEAR GENERATING STATION Containment Vent and Purge Valves Spring Torque Availability for 656-60 Actuators Assuming Control Air Vented (Diaphragm Casing Pressure = 0 psig) For 8" 9100 For 8" 9100 For 12" 9500 S/N: 103160-61 S/N: 103162-63 S/N: BF200233-234 0-90 Rotation 0-60* Rotation 0-90* Rotation Valve 4" Actuator Stroke 4" Actuator Stroke 4" Act0ator Stroke Position 6-26 psig Air 6-26 psig Air 3-15 psig Air Spring: 1K16?827082 Spring:1K162827082 Spring:1K162727082 (Degrees Open) Spring Closes Spring Closes Spring Closes Dsgree Torque (in-lb) Torque (in-lb) Torque (in-lb) 0* 2322 4022 1161 1* 2397 4173 1196 5* 2675 4754 i 1323 15* 3250 6060 1587 30* 3930 7825 1899 45' 4518 9590 2169 60* 11629 90* 6714 3177 4 %W.

05;. Z C z ; ;. a ;. a u.;m _ m e u - r - = - :- - -a-9 REFERENCE I Telecopy from GPUh to BNL July 23, 1986, containing revisions to Stress Table 5 (3 pages) part of TDR 266, Rev. No. 2. e, e# e 1 L .: 2 e ~~ T.

a. ~% M:w. we.. d.

4. %

.*t o.

  • .t klof'":F

., ty.. w. .:;.3....... l- .. g . r. :;.s9..y. t. .v ..s .....s. o..;.:.. ,i., g .,.4.], Mt.F3.W. -

e. 7Antz $?- stavtAar or s'rassa amatins

.c.. (

e.. x..

it ^ 3 y,.. t tau 2JP 'M *,. -(W!.Mt ~ g. STROS Fl1ME laE3, AtJDeLalJt Stless lews) Agge 333 eggeston 1

k. t De0E3rf '.

sewe-Am sueat-(F.11) (Pst) ramme===w mo.

  • 1 Ic..s..ss,I mmnu'^

g ;,. Ig . '. :p un i _22600, 27000j '[t...., [,,,{4+.....!. t. h @ h aw,, .a. Pm usu26(e(.. f a( a; t. 888 '545 1I*3IIIe y. ,.,8,,

t. V Ye hinwy plus secord.uy cp
..f,,:;n. g. :. > 3 m

c.. t. ....e. stre.u e a to 1 recant-2012 m me n s.2tasitt .j.

e. V

. pre sure. tuo h, s.;.r. i.:* .:.l.:.. k:p pipac Antal l Pad ..,e; / ~;. !T;8.. . >j[2b,-l,. am#.-,;, reacticas na 1545.2 m) (!) 5 45F4 Ii .m .l.: '..: g. ,= n,., m, mn .a.. m., o,,,,, p,. l.: M,.ve IE n.m[.p,( k'- 't a k he Q,

== m s. n.1 f

r.

,wo-r mi.y 2 .4 p

n. p

~m en.= a.-.4.....- mzr n., s 2,.., . a t.%g..; n ne nean m ..w-J.y -un.> c L. W:.c . -o

m.

-Aa -*, . sm. 1.s. 4.. q :. s..-g.._,..

74..

%s..-, Stress en disc cantar1Lt. 2s71 ,,, m., go,co q .s N.sh, '.. [' -l stonal shear stzens ' S(9) 2ts6 .33{2/3 sy, V4 et}

  • ;?

[. ; F e+.y ;., ' .c,c 1.Ein.1 snear m sm ans .mbe.a7.trsoo} ""2' 7, ../.. : r1: @t'g.m.

== s ?a s /* cre:6mi bardings ;; . sm .mfaner,veyel , ;,,i. L; *:

p... f,.,s; angt -

32n .n 3:o) ..r. n d.- .i. 966u. uw .;'...i,p. - ' '.'. i s :. ; f...- -w .saIvi ur, va er L l'.. 3- -t=f2'' 5aal } t ihinal stress: sm a

9. ' f E s art,se n r': d'Mi. -

( ***' "' d '**di' ~ 3* '. d.:. n.. h .r 4:, 4 ;-V'::.. -m[v2s -.N shaarf. mess en. 9.- a(16) c, r [:, l;f - W: am(25457,t'rsocF "" ' 8* 8

7...' i.,

4.. =. n sy, v4 s=. '.~; R.:. ca m la w.c shear: crm in st173 m ia .: 1 =1= socoa. 21soo} )

        • M*)

7

+

l'1.:,:::G...p1ns-pu. (.

1. '

I ~j, ' 7* '[.. ' m:td.rgs.'.'" R.erirug stime la -,- $(21) 1317 W we allrasehle*

  • f E.*
  • s

.2;p,. If ', y-(et.af t. bearing) ra.shings 4000 s. .r. . K.).. , Jo Tsuis&on in hnits, :, 'StS41, > 1... 1510 mu{ussy,yest). r,. Opsratdr =~ f V... nl... .sas . w a m o. u se.; .,.y pg; ,,gg,3 g,y w. 1 A...Q. s.,. j3 f.::s:..:. ,C"A'."&,, s. :

2',N'c IMP muu w>

v 8., s. a - ~. ...,,*r...

..c

.t n :,g, ., =.,

.;~,e.:.

n ~ ..o..

o,..u..,...~. ],.)-
: g'?...g.g *betonemee $@

. y>.. c., r: ,,, -. *. t. ..e .t*r .p... .. ?,

  • g-j 2,,

.y. '. I. ' .}- 1- ~. .i:* rf, ". *!); f..,*, :- ,*,g. . - y =.*te. -. 'f 3 0Ce df 2 s' 4 j. p. : :: 8.. - y. _*.2* .4..-. ~. .1r

l .h ~v-' 6. - ~ ' - e-- ~ -.*- P... 4 2. e 3 [.. a:... ;.; .c, c..:e@r c..>.W ).' = .c W **:; w. [. f . ' ' 4 '.

  • FASTE s'(Omt.'d1
  • /[-
  • ,k IMINE

?.' Wh&M: i 'Snm sti c tart 2. Auamarz suess esei assim t r ervienas 1 i gegy '$. f. CDGCaeDar - Wa A#O S9eCL ' -/. (Pst) (Pst)- pW. [, {' muilse, o.s sy j_h_ essis45.t(e)(1), m3524 . 'C i E.; ~ PrleiryJesseane ~ Pm 1360 , i.b.u.H.f ensip26tm, 2 V e m 33364st- ',, -{T. [r . -Q,.

d..

~ : h. - triu/ plus serurtary CP sus n Tr -..jg,.

g. :

c'., .7 A,.:.,g. strer.2 due to inteamt. 'm u..- menes.a c.ut) ecccoute

i. !
s..r.:.,.:,y.

,e.h-e.

l?'f.

'. ? 1"3 'Y-'.. 'i ; pipe' Azieli. Pre J320 15* sesses.2 as(1) - i.x. masy ; . roncuen a , 3. '... (. ' '., stress accxlG4-Peb 9050 i h__ .-((: ,us M 45.3EM tt) -e. . r.. -..12t1 . t I' t S-2s47,y.Y... ,Qn 1ersion ' Pet 7,,, L ,,,n,,,,,,,yg,, u. -.s .Asl seconlary ot . : c;. rai 62s;1st.- 1,.*;.... - bross .20 I1 .i -;.,.'... - nesses.t . ;-,i v. y

g... z

,,, p,. Prieary plus Sn 11237 19e mim.2 8 4 .e

e...

,: /e;y.* I i. v,,l '., p}i .. cue.ry ser-. neco ,.* w ~) e '.j...o(.; Dime stress on disc contar11ns ' 7,*f w' C! (traatret perdine - Stil T" ! , ;. '. f

lis, t.s sua ne ues.2

.(.,y .,7 .tn[V3 sy, U4 st} .,., e e. -. q a,,, [q ? r.., e' : i,,7 ideslonni ar.nar street. sa) s7t2 ,,3g, y,3

  • y,., ' 1.c s

=Sa(53867.15a00} ~ ,. ' '.., 1,.~. "Er&Tumi f6Es'tTess. s(61 . seas 1 P. 2 min 2/sor, vest) 'esa n46.3q.3 ~,;C '. ;P,. t

c.,., j ',

,, maan.., otseined bendire,. S(5) H. 4 4,12 L stJtSs - ein 63M7. 35000} 6.- ...f, ',, ,, ;. j,,, [2 y h..f..q, is

  • 4 8114 )
  • tn{2/1sy,yeut) p

.-'. l I' 5 *.:-. ., b Ctr61ruzi stress ans ,,,,,3 e .*g eM Isidirgl-

  • Lal'3457. 3*003
emis46.2

} T l h.:3.p'.,{.. -

  • N*

, FF,. ala{2/3 sy, .. aQ ,,,3 ,3 g,3 . h,.,. . 5 ~.'.. Shatt.Xay 'srm,r stress en - s(16) g g,, 4,y i.g.' ] (g r,.,*,,( ).uy - =lal66667. 18 750}

'-. (s k'[f g.

g i-'4 ; Cla: tasper. Shed;stressin l :JH7) alakV3 8Y. U4 dh g. t

  • ,. ; y?g]'

~* Cv .,J.,g .l^. pim - pir.s + 19077 , min {s3113, 35o00) "1

  • ~

3;3 ..,4 5 +;.;n.,.. l T. t-

  • - 11 2.093...

twm; stress in, s(21) ,st - crossressive al1<=aah8e* .g

v....

9s.:,. p.i. : w b,+1 e tw.usns noua ~< 4' V::.2),. ' .h. " wow.und) .s=(2/3sr.Uest m 2546.stel "y,4 p?:.,.'. 7 d N

y. weaor :*

Tension 'ir, tolts - - StL4) 16: opsrat +stsss - 35 t ..t m =r. v<y) .sms. u.> a s.c. v' a,y: sum m ss m r.~ toTor e e vibolts, ;...

  • 1 =' '"""" *
a...

5e . t... y.9,..s,. +....e t . t: O o+ 4*j +- q; pt'.R. ,,.. ; r 3. . t:'. p..~?,,.,* : 1.. : ?. ,.a.L., f,. W .t,; ...l, ... * *.. r ., t.., ol y,; p. ...,,.'.,A,5t'.. b, Massace,0.I.. .p. P.. ; ,c* g.'.,,,-

  • s.

~.. - ; -. f*f., ....,..,4.*:,. p -' s a y.. ag s 3*..,. ;..;; e, * :... * = ...r. ,?

..-(-.
..;.e.

t g ..f ...,.8'

i. <.

j'lp%; fsTl ='.-~.,',.... .. J. s .s .; e 8.; s. . -* d e. .e**. 1 y.., ..y ;,. -.+. .ss.- (?

[.40 ."?: ,.O,-.

  • w

_- y . tasas - N W.te -sncss si Ess saur. atarmeaut suuss ' ioni s.s sus estvi;sas a ~<- 5;. iE {pS1) (PSI) .wasc.anr3 amp. .'.. D. 'I ' - MIS. ' 7#* G300E3R - DWCJWO S19El. .ia {sm. e.9 sri. , instS4%.ita) til, senze. '.5.:. *. s e.. 4 & ..4: s-Pris.asy Prweacano. 34. 1394 .L. 14500. J7000) M26 8 5 i, h.. .J. p Q.i.[! .gf. !..,,*y

    • b#

Prismary plus urmdary (gi .f, . s.. ?.-l l g.' t f. U* '.'..,.,.. {.h -c:.- .." 4. ' seseos itsse to internal 3927 m m3ses.2(at til a g ?;.. 14sco gn.,

' M. !,

.. af 1 p, >.:. ~. n y W".e.'g 8 "i 5;Q $ :....Q s.;. ' ' pipe- . i ami 2. 'ea ,,...um i, 1i w P._;y. a=4r- ! E m" s~ r== edam ..t.. mj,y ),,,n.s.2 n. un ^ " ' h:- .:.i .aws a -ata, Pa, O r,12cig,7'I- *.,*r 3 M.. '.,1.' *. 4 b23-L23-14 M t.. st>rslam peg i 16446 1.5 9a l g,. g ggy t 4 250 .:'.f...,.., 4 3'. I b23 15, ! V.:r. '. p,g. -* I O

5.,.!! -

1.. 3 thecvisL a oordary ce. 413 an - 9:n-14.- i4sco = m s.2 a <..~..:/..-. . stress @.; f. $,.. i,f V. i. Prtsury plus sn 7stae 3 si. . 3g,,, ,si F;.'.f ~'.5 3 a q. e 4 saxweary strans,..- usoe . s s. .t 4gy \\ i... '. v. 5. <...>. ometne aarding - sm ion i.s s. e ...niae --

    • N *3

,p ;i. R. ~. f...y :... .strees on atse canterline- . d.. ). [**:FJT'd I to : ut sent series - sist s27t =ml2h sy. v4 s=} T. J.C. ' -

3. g.p. '.if.1. -

"E W Scarstr== sm 1 d. T.a f.F im -u 9 m). u'5*f I ? s. t

  1. .,i. 5 g;.

= b.* ; s 's.i. unti cter,mi berdinen. stsi .ta(an sr. us st) W,. M, f M. stro== .a {2n,,. v,,4 st) . ;.....l Q =alami.isno)

    • 5"**

i= ..g. 's(4) 35.. u., . e ..' i. ' li.:. .p kw/.".,?gl.$ .'tr ? ..t. 1 -l.. - - Ainst stresa i ishear ans herdust..

k. 'g,'..b.,J:

me ,1,p 3 m, 3, ,g ,r,,g.7,,,,, e o.. u 3 . y nar q .;1- ' s t1(,) = tai 2n sr. V8 stJ .nu. u.s t ;;;f.. y i- ' 'p;':< igm-2. shaft say. shear sert-w on, em

.,.: s.

n j,a.. 3 i:. .apsus, nanot N;p s ed ,: s fy.y p w.,Q ciscasyni msar-ser.s. in. sil71 u ma ~ =wl2n er.1/' **I l.-- d .iolami, annoj l non es. s t=> .f.D,. F,, 6 -l :,. c piasi ..r ... :. p s - c

1. t~p; ::

C=' = d a ^18a

  • 1* *

- :v ?. :.;.'".W; e. sc 4-e.srih.ame u... s(zu we g.-4...VM.: a=hin,.. i:.. v..a 4, 2a" . g-.,uaa e w.at, s ...s 3 .s ssi malm co. immJ ~.i. T. i;. d ~ =wl2n sv. V* 8'l = n a.uai l M, S - sis 4: m4m .rq.jp.. cp r. ear - ren s,in a mait 5.- m eg% sV71 r a .1, c..H 3 sn =,o to ,m3 .inisn.,. temav..s e . u,, .f.g... . 1 4.o w,., nau .a omoa.. ,. e'....,;..t h. 3. . ::(:s. :.y. a. r,t b t>P.:;... y,., 2.: : /. -i .?. O, .9:; .....'.:: :. ?. .M... : h;

  • .v

~. w....wo .s'.: 9 :.. M,m.au.a. s.s. ..\\.....%.- y g.%. ;g..v. - ....,.....,....r,;.. , a,. .c. ; -. ..,v ..s .s,. r.... +.c ~. m... s..- ??... Q

, e. :
t...

,L

n.. :.. u. m.g.:..

~ s".;. -.y.-n.. s

c.,..

,.s ;. <.. < u

s.

t i .. =.. m...- 7l. .}}