Text
-
. _ - - .
. .-
- -.
-
-
-.
- - -
.
=
-
-
3
e
March 4, 1998
University cf Virginia
ATTN: Dr. R. U. Mulder, Director
Reactor Facility
Charlottesville, Virginia 22901
Gentlemen:
J
SUBJECT: NRC INSPECTION REPORT NO. 50-62/98-201, NOTICE OF VIOLATION, AND
i
NOTICE OF DEVIATION
i
On January 26-28, 1998, the NRC conduct.ed an inspection.of your University of Virginia
F.eactor (UVAR) facility. The enclosed report presents the results of that inspection.
\\*arious aspects of your radiation protection and safety programs were inspected 3 'cluding
selective examinations of procedures and representative reccrds, interviews with personnel,
and observation of activities in progress.
As a result of the inspection, a violation and a deviation were identified. The NRC is concerned
because the violation appears to have been the result of a lack of attention to detail. The
deviation appears to have resulted from insufficient staffing. The violation and deviation are
cited in the enclosed Notice of Violation (Notice) cnd Notice of Deviation, and the
circumstances surrounding the violation and deviation are described in detailin the enclosed
report.
in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and
its enclosure will be placed in the NRC Public Document Room (PDR).
If you have any questions concerning this inspection, please contact us.
Sincerely,
ORIGINAL SIGNED BY:
Marvin M. Mendonca, Acting Director
Non-Power Reactors and Decommissioning
Project Directorate
Division of Reactor Program Management-
Office of Nuclear Reactor Regulation
Dockat No. 50-62
License No. R-66
Enclosures:
1.
NRC Inspection Report No. 50-62/98-201
l
2.
3.
Notice of Deviation
g
cc: _ See next page
' , .[
3 3
'
DISTRIBUTION:
4
HARD COPY
m
(? Docket File 50-62M
SWeiss
, g-
PUBLIC
CBassett
AAdams
WEresian
_ g
o.
PDND r/f
EHylton
TBurdick
SHolmes
DScrenci, (2)
BJones
PDoyle
Plsaac
g:o
5
WDean, OEDO
MMendonca
TMichaels
JRoe
. DISP /PIMB (012-H7)
TDragoun
ng
_
M
'g
f
-
b
PD,
- PM
P
- bA
PDND:(A)D
U
/
ett
s
n
MMendonca
Oa:
3/i/98
3/ /98
3/ /98
3/f/98
No
OFFICIAL RECORD COPY
DOCUMENT NAME: G\\SECY\\BASSETTilR50-62
NP& Hl.E CENTBil COPY
ll li Ill!II,ll llll
- _____ _- -_- -____- - _--- - - - - - -- - - -
--
-
<.
.
..
,
March 4, 1998
University of Wrginia
-
ATTN: Dr. R. U. Mulder, Director
Reactor Facility
Charlottesville, Virginia 22901
Gentlemen:
SUBJECT: NRC INSPECTION REPORT NO. 50-62/98 201, NOTICE OF VIOLATION, AND
NOTICE OF DEVIATION
On January 26 28, 1998, the NRC conducted an inspection of your University of Virginia
Reactor (UVAR) facility. The enclosed report presents the results of that inspection.
Various aspects of your radiation protection and safety programs were inspected including
selective examinations of procedures and representative records, interviews with personnel,
and observation of activities in progress.
As a result of the inspection, a violation and a deviation were identified. The NRC is concerned
because the violation appears to have been the result of a lack of attention to detail. The
deviation appears to have resulted from insufficient staffing. The violation and deviation are
cited in the enclosed Notice of Violation (Notice) and Notice of Deviation, and the
circumstances surrounding the violation and deviation are described in detailin the enclosed
report.
In accordance with 10 CFR 2.700 of the NRC's " Rules of Practice " a copy of this letter and
its enclosure will be placed in the NRC Public Document Room (PDR).
l
If you have any questions concerning this inspection, please contact us.
Sincerelv,
ORIGINAL SIGNED BY:
Marvin M. Mendonca, Acting Director
Non Power Reactors and Decommissioning
Project Directorate
Division of Reactor Program Management
Office of Nuclear Reactor Regulatk,n
Docket No. 50-62
License No. R 66
Enclosures:
1.
NRC Inspection Report No. 50-62/98-201
2.
3.
Notice of Deviation
cc: See next page
DISTRIBUTION:
HARD COPY
Docket File 50-62
SWeiss
E-Mall
PUBLIC
CBassett
AAdams
WEresian
PDND r/f
EHylton
TBurdick
SHolmes
DScrenci, (2)
BJones
PDoyle
Pisaac
WDean, OEDO
MMendonca
TMichaels
JRoe
DISP /PIMB (012-H7)
TDragoun
G
m
h
, lR
PDN :PM
D
PDND:(A)D
dsett
.
affis
ton
MMendonca
3/4/98
3/Y /98
3/ /98
3/f /98
OFFICIAL RECORD COPY
DOCUMENT NAME: G\\SECY\\BASSETT\\lR50-62
,
.
..
_._
._
.
.
.
pun
o
y*
t
UNITED STATES
s
j
NUCLEAR REGULATORY COMMISSION
.
t
WASHINGTON, D.C. 2M6H001
%.....
March 4, 1998
University of Virginia
t
ATTN: Dr. R. U. Mulder, Director
Reactor Facility
Charlottesville, Virginia 22901
Gentlemen:
SUBJECT: NRC INSPECTION REPORT NO. 50-62/98 20! h ~)TICE OF VIOLATION, AND
NOTICE OF DEVIATION
On January 26 28,1998, the NRC conducted an inspection of your University of Virginia
Reactor (UVAR) facility. The enclosed report presents the results of that inspection.
Various aspects of your radiation protection and safety programs were inspected including
selective examinations of procedures and representative records, interviews with personnel,
and observation of activities in progress.
As a result of the inspection, a violation and a deviation were identified. The NRC is
concerned because the violation appears to have been the result of a lack of attention to
detail. The deviation appears to have resulted from insufficient staffing. The violation and
deviation art cited in the enclosed Notice of Violation (Notice) and Notice of Deviation, and
the circumstances surrounding the violation and deviation are described in detailin the
enclosed report,
in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter and
its enclosure will be placed in the NRC Public Document Room (PDR).
If you have any questions concerning this inspection, please contact us.
Sincerely,
m
%_
,
'
-c7.
M
M de
%.
Marvin M. Mendonca, Acting Director
Non-Power Reactors and Decommissioning
Project Directorate
Division of Reactor Program Management
Office of Nuclear Reactor Regulation
Docket No. 50-62
License No. R-66
Enclosures:
1.
NRC Inspection Report No. 50-62/98-201
2.
3.
Notice of Deviation
cc: See next page
.,.
.
a
.
.
,
.
University of Virginia
Docket Nos. 50-62/396
cc:
Department of Environmental Quality
Dr. Ronald D. Flack, Chairman
Office of Grants
Department of Mechanical, Aerospace
Manegement/ Intergovernmental
and Nuclear Engineering
Affairs
University of Virginia
629 East Main Street, Sixth Floor
Charlottesville, VA 22901
Richmond, Virginia 23219
Te2., Research, and Training
Mr. Preston Farrar
Reactor Newsletter
Nuclear Reactor Facility
University of Florida
School of Engineering
202 Nuclear Sciences Center
and Applied Science
Gainesville, FL 32611
,
University of Virginia
Charlottesville, Virginia 22903
Leslie P. Foldesi, Director
Bureau of Radiological Health
Dr. Ronald D. Flack, Jr., Chairman
Division of Health Hazards Control
Department of Mechanical, Aerospace
109 Governor Street, Room 916
and Nuclear Engineering
Richmond, VA 23219
University of Virginia
Charlottesville, Virginia 22903
Dr. William Vernetson
Director of Nuclear Facilities
Department of Nuclear Engineering
Sciences
University of Florida
202 Nuclear Sciences Center
Gainesville, Florida 32611
Dr. Rolan E. Hertel, Director
Neely Nuclear Research Center
Georgia lostitute of Technology
900 Atlantic Drive, N.W.
Atlanta, Georgia 30332
Mr. Pedro B. Perez, Associate Director
Nuclear Reactor Program
North Carolina State University
P. O. Box 7909
Raleigh, North Carolina 27695-7909
Office of the Attorney General
101 North 8th Street
'
Richmond, Virginia 23219
Bureau of Radiological Health
Division of Health Hazards Control
109 Governor Street, Room 916
Richmond, Virginia 23219