MM F E Log # TXX 98059

=. .= File # 10010.1 r C 905.2 (clo) 7UELECTRIC Ref. # 10CFR50.55a(g)

March 5, 1998 I

c. u .e. n cry 5enior Mce President l

& PrincipalNuclear Oficer l l

U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES) UNIT 2 DOCKET NO. 50 446 SUBMITTAL OF UNIT 2 THIRD REFUELING OUTAGE INSERVICE INSPECTION (ISI)

SUMMARY

REPORT (UNIT 2: 1986 EDITION OF ASME CODL. SECTION XI, NO ADDENDA, INTERVAL START DATE AUGUST 3, 1993. FIRST INTERVAL)

Gentlemen:

This letter forwards the Inservice Inspection Summary Report for the third refueling outage of CPSES Unit 2. The enclosed report is being provided to you pursuant to the ASME Boiler and Pressure Vessel Code Section XI, <

paragraph IWA 6230. A copy of this report is also forwarded to Mr. G. Bynog in accordance with the Texas Boiler Law & Rules and Regulations, paragraph 65.100.g.4. Please note that the Relief Requests included in Appendix C of the Enclosure are for information only. A formal request for relief has been submitted by a separate transmittal (TXX 98058, dated March 5, 1998).

This communication contains no new licensing basis commitments regarding CPSES Unit 2. If you have any questions, please contact Mr. Carl B. Corbin at (254) 897 0121.

Sincerely. /

0.h & p 'l C. L. Terry 9803090347 980305 g I b $ ./[/ f' A PDR ADOCK 05000446 By:

G PDR

" " V d Roger'O. Walker [

Regulatory Affairs Manager CBC/cbc Enclosure c- Mr. E. W. Herschoff, Region IV Mr. J. I. Tapia. Region IV (clo)

Resident Inspector, CPSES Mr. T. J. Polich, NRR Mr. G. Bynog, TDLR

/, I COMANCHE PEAK STEANI ELECTRIC STATION  ! If ff P.O. Bos 1002 Glen Rose. Tesas 760 0 100_

I ENCLOSURE TO TXX 98059

- . .