March 2, 1998 Mr. H. B. Barron i
Vice President, McGuire Site Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, North Carolina 28078-8985
SUBJECT:
SAFETY EVALUATION FOR GROUNDWATER ALARM MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 (TAC NOS. M97709 AND M97710)
Dear Mr. Barron:
The staff has completed its review of Special Report (SR) No. 96-04 dated November 14,1996, and subsequent revisions, which were submitted by you, as required by Selected Licerwee Commitment No.16.9-8, " Groundwater Level (GWL] Monitori,1g System." As stated in the enclosed safety evaluation, the staff finds that the GWL alarms received at Well Mk. GWA 2, since October 1996 located near the Unit 2 Reactor Building, do not pose any safety hazard either for the safety-related structures, systems, or components or for the public.
The staff considers this matter resolved and is closing out TAC Nos. M97709 and M97710.
Sincerely, ORIGINAL SIGNED BY:
Frank Rinaldi, Project Manager Project Directorate ll 2 Division of Reactor Projects - 1/Il Office of Nuclear Reactor Regulation Docket Nos. 50 369 and 50 370
Enclosure:
As stated cc w/ encl: See next page DISTRIBUTION:
Docket File JZwolinski ACRS PUBLIC HBerkow LPlisco, Rll
[/{} l PD ll 2 Rdg.
LBerry COgle, Rll GBagchi FRinaldi RPichumani, ECGB OGC To receive a copy of this document, Indicate in the box: "C" = Copy without attachment / enclosure
'E" o Cop'/ with attachment / enclosure "N" = No copy OFFICE PM:PDll 2 LA:PDil M dGQ D:PDN%el NAME FRina'di:crL,lf'l _
LBerry M>
M*
HBerkoM /
DATE
'l / L /98 C
og/q/98 7
/ /98 \\
5/ L /9B
/ /98
/ /97 f
DOCUMENT NAME: G:\\MCGUIRE\\M97709.WPD OFFICIAL RECORD COPY o
hm
_ a
pm Cio ye UNITED STATES s
_}
NUCLEAR REGULATORY COMMISSION
't WASHINnTON D.C. 306 4 0001
%.....[
March 2, 1998 i
Mr. H. B. Barron Vice President, McGuire Site Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, North Carolina 28078-8985
SUBJECT:
SAFETY EVALUATION FOR GROUNDWATER Al. ARM MCGUIRE NUCLEAR-STATION, UNITS 1 AND 2 (TAC NOS. M97709 AND M97710)
Dear Mr. Barron:
The staff has completed its review of Special Report (SR) No. 96-04 dated November 14,1996, and subsequent revisions, which were submitted by you, as required by Selected Licensee Commitment No.16.9-8, " Groundwater Level [GWL) Monitoring System." As stated in the enclosed safety evaluation, the staff finds that the GWL alarms received at Well Mk. GWA 2, since October 1996, located near the Unit 2 Reactor Building, do not pose any safety hazard either for the safety related structures, systems, or components or for the public.
The staff considers this matter resolved and is closing out TAC Nos. M97709 and M97710.
Sint,erely, Q tm.ft n % A.s i
/
Frank Rinaldi, Project Manager Project Directorate 112 Division of Reactor Projects - 1/ll Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50 370
Enclosure:
As stated cc w/ encl: See next py,
i McGuire Nuclear Station cc:
Mr. Paul R. Newton Ms. Karen E. Long Legal Department (PBOSE)
Assistant Attomey General Duke Energy Corporation North Carolina Department of 422 South Church Street Justice Charlotte, North Carolina 28242 P. O. Box 629 Raleigh, North Carolina 27602 County Manager of Mecklenburg County L. A. Keller 720 East Fourth Street Manager. Nuclear Regulatory Charlotte, North Carolina 28202 Licensing Duke Energy Corporation Michael T, Cash 526 South Church Street Regulatory Compliance Manager Charlotte, North Caroita 28242 Duke Energy Corporation i
McGuire Nuclear Site Regional Administrator, Region ll 12700 Hagers Ferry Road U.S. Nuclear Regulatory Commission Huntersville, North Carolina 28078 Atlanta Federal Center 61 Forsyth Street, S.W., Suite 23T85 J. Michael McGarry, Ill, Esquire Atlanta, Georgia 30303 Winston and Strawn 1400 L Street, NW.
Elaine Wathen, Lead REP Planner Washington, DC 20005 Division of Emergency Management 116 West Jones Street Senior Resident inspector Raleigh, North Carolina 276031335 clo U.S. Nuclear Regulatory Commission Mr. Richard M. Fry, Director 12700 Hagers Ferry Road Division of Radiation Protection Huntersville, North Carolina 28078 North Carolina Department of linvironment, Health and Natural Mr. Peter R. Harden, IV Resources Account Sales Manager 3825 Barrett Drive Westinghouse Electric Corporation Raleigh, North Carolina 27609 7721 Power Systems Field Sales P. O. Box 7288
- Mr. T. Richard Puryear Charlotte, North Carolina 28241 Owners Group (NCEMC)
Duke Energy Corporation Dr. John M. Barry 4800 Concord Road Mecklenberg County York, South Carolina 29745 Department of Environmental Protection 700 N. Tryon Street Charlotte, North Carolina 28202
.