05000391/LER-2020-001, Control Room Emergency Ventilation System Inoperable Due to Main Control Room Door Being Left Open
| ML20197A177 | |
| Person / Time | |
|---|---|
| Site: | Watts Bar (NPF-096) |
| Issue date: | 07/15/2020 |
| From: | Anthony Williams Tennessee Valley Authority |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| WBL-20-029 LER 2020-001-00 | |
| Download: ML20197A177 (7) | |
| Event date: | |
|---|---|
| Report date: | |
| Reporting criterion: | 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(ix)(A) 10 CFR 50.73(a)(2)(iv)(A), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) |
| 3912020001R00 - NRC Website | |
text
Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381 July 15, 2020 WBL-20-029 ATTN : Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Watts Bar Nuclear Plant, Unit 2 Facility Operating License No. NPF-96 NRC Docket No. 50-391 10 CFR 50.73
Subject:
Licensee Event Report 391/2020-001-00, Control Room Emergency Ventilation System Inoperable due to Main Control Room Door Being Left Open This submittal provides Licensee Event Report (LER) 391 /2020-001-00. This LER provides details concerning the inoperability of the Control Room ventilation system from a Main Control Room door being left open. This condition is being reported as an event or condition that could have prevented fulfillment of a safety function in accordance with 10 CFR 50.73(a)(2)(v)(D).
There are no regulatory commitments contained in this letter. Please direct any questions concerning this matter to Tony Brown, WBN Licensing Manager, at (423) 365-7720.
__,,,,,-nmony L. Williams IV Site Vice President Watts Bar Nuclear Plant Enclosure cc: See Page 2
U.S. Nuclear Regulatory Commission WBL-20-029 Page 2 July 20, 2020 cc (Enclosure):
NRC Regional Administrator - Region II NRC Senior Resident Inspector - Watts Bar Nuclear Plant
NRC FORM 366 (04-2020)
NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION (04-2020)
LICENSEE EVENT REPORT (LER)
APPROVED BY OMB: NO. 3150-0104 EXPIRES: 04/30/2020
- 1. Facility Name Watts Bar Nuclear Plant, Unit 2
- 2. Docket Number 05000391
- 3. Page 1 OF 5
- 4. Title Control Room Emergency Ventilation System Inoperable due to Main Control Room Door Being Left Open
- 5. Event Date
- 6. LER Number
- 7. Report Date
- 8. Other Facilities Involved Month Day Year Year Sequential Number Rev No.
Month Day Year Facility Name NA Docket Number 05000 05 19 2020 2020 - 001
- - 00 07 15 2020 Facility Name NA Docket Number 05000
- 9. Operating Mode
- 11. This Report is Submitted Pursuant to the Requirements of 10 CFR §: (Check all that apply) 3 20.2201(b) 20.2203(a)(3)(i) 50.73(a)(2)(ii)(A) 50.73(a)(2)(viii)(A) 20.2201(d) 20.2203(a)(3)(ii) 50.73(a)(2)(ii)(B) 50.73(a)(2)(viii)(B) 20.2203(a)(1) 20.2203(a)(4) 50.73(a)(2)(iii) 50.73(a)(2)(ix)(A) 20.2203(a)(2)(i) 50.36(c)(1)(i)(A) 50.73(a)(2)(iv)(A) 50.73(a)(2)(x)
- 10. Power Level 20.2203(a)(2)(ii) 50.36(c)(1)(ii)(A) 50.73(a)(2)(v)(A) 73.71(a)(4) 000 20.2203(a)(2)(iii) 50.36(c)(2) 50.73(a)(2)(v)(B) 73.71(a)(5) 20.2203(a)(2)(iv) 50.46(a)(3)(ii) 50.73(a)(2)(v)(C) 73.77(a)(1) 20.2203(a)(2)(v) 50.73(a)(2)(i)(A) 50.73(a)(2)(v)(D) 73.77(a)(2)(i) 20.2203(a)(2)(vi) 50.73(a)(2)(i)(B) 50.73(a)(2)(vii) 73.77(a)(2)(ii) 50.73(a)(2)(i)(C)
OTHER Specify in Abstract below or in Page 5 of 5
A. Immediate Corrective Actions
The open control room door was identified and promptly closed. Door peer checkers were placed at the MCR door to ensure proper door closure until completion of MCR lighting upgrade work and then an additional two weeks.
B. Corrective Actions to Prevent Recurrence or to reduce probability of similar events occurring in the future The individuals involved were coached on the requirement to challenge the door when traversing the control building complex. Briefings were conducted for task managed supplemental craft personnel on both shifts for this event. There is an action to brief all personnel that are in-processed on the sensitivity of all pressure boundary doors and the expectations regarding ensuring they are properly closed and latched upon entering and exiting.
VII.
Previous Similar Events at the Same Site
LER 390/2019-001-00, reported an instance where the control room boundary door had been left open due to personnel error and promptly closed by operations in response to a low control room positive pressure alarm. The cause of this event is similar.
LER 390/2019-004-00, reported two instances where a control room boundary door had been left open due to personnel error and promptly closed by operations in response to a low control room positive pressure alarm. The cause of this event is similar.
There have been other events in with the MRC doors such as LERs 390/2018-003-00, 390/2018-004-00, 390/2017-007-001 and 390/2017-014-00 with similar causes.
VIII.
Additional Information
There is no additional information.
IX.
Commitments
There are no new commitments.