Advises That 880523 Response to Generic Ltr 88-03, Steam Binding of Auxiliary Feedwater Pumps, Satisfactory
ML20196L281
Person / Time
Site: Maine Yankee
Issue date: 06/30/1988
From: Sears P
Office of Nuclear Reactor Regulation
To: Randazza J
Maine Yankee
References
GL-88-03, GL-88-3, TAC-67245, NUDOCS 8807070340
Download: ML20196L281 (2)


Text

_ _.. - _ _ _ _ _ - _ _ _ _ _ - _ _ _ _ _

t.

a June 30, 1988 Docket No. 50-309 Mr..J. B. Randazza President Maine Yankee Atomic Power Company 83 Edison Drive Augusta, Maine 04336

Dear Mr. Randazza:

SUBJECT:

GENERIC LETTER 88-03, "STEAM BINDING Of AUXILIARY FEE 0 WATER PUMPS "

(TAC N0. 67245) 0n February 17, 1988, Generic Letter 88-03 was issued and requested all licensees of operating PWRs and holders of construction permits for PWRs to confirm that appropriate proceduros are in place, and will be maintained, to minimize the occurrence of steam binding of the auxiliary feedwater (AFW) pumps. The procedures require monitoring fluid conditions within the AFW system each shift during times when the system is required to be operable, and recognizing steam binding and restoring the AFW system to operable status should steam binding occur.

Your response, dated May 23, 1988, confirmed that you have in place, and will maintain, the necessary procedures. Thus, your response to Generic Letter 88-03 is satisfactory and no further action is necessary.

Sincerely, Original signed by.;

Patrick M. iears, Project Manager Project Directorate I-3 Divirion of Reactor Projects 1/11 cc: See next page DISTRIBUTION: 4 Docket' File Local & NRC PDRs, PDI-3 r/f, 0GC, BBoger, SVarga, Edoraan, BGrimes,"PSeTri, MRushbrook, ACRS (10), RWessman (M

OFC :PDI-3

PDI-3
DIR/PDI-3

....- e_.. g..-_:.......---- :..)ppyg g. :_----.......:--..........:...___....--:---__.. ___

NAAE MRushbrook

PSears:mw
RWessman
...............
. _ _.. _ _ _ _ : g/ 2e7 88 CATE frW30/88 rts/ /88
W OFFICIAL RE COPY

[C 0

8807070340 880630 DR ADOCK 05000309 PDC

b Mr. J. B. Randazza Maine Yankee Atomic Power Company Maine Yankee Atomic Power Station cc:

John B. Randazza, President Mr. P. L. Anderson, Project Manager Maine Yankee Atomic Power Company Yankee Atomic Electric Company 83 Edison Drive 1671 Worchester Road Augusta, Maine 04336 Framingham, Massachusetts 07101 Mr. Charles B. Brinkman Mr. G. D, Whittier, Manager Manager - Washington Nuclear Nuclear Engineering and Licensing Operations Maine Yankee Atomic Power Company Combustion Engineering, Inc.

83 Edison Drive 7910 Woodmont Avenue Augusta, Maine 04336 Bethesda, Maryland 20814 John A. Ritsher, Esquire Ropes & Gray 225 Frank.'n Street Boston, Ma=sachusetts 02110 State Planning Officer Executive Department 189 State Street Augusta, Maine 04330 Dr. E. T. Boulette, Plant Manager Maine Yankee Atomic Power Company P. O. Box 408 Wiscasset, Maine 04578 Regional Administrator, Region I U.S. Nuclear Regulatory Conmission 475 Allendale Road King of Prussia, Pennsylvania 19406 First Selectman of Wiscasset Municipal Building U.S. Route 1 Wiscasset, Maine 04578 Mr. Cornelius F. Holden Resident Inspector c/o U.S. Nuclear Regulatory Commission P. O. Box E Wiscasset, Maine 04578

_. _