Text
. _ _
flarch 4,1993 Docket Nos. 50-338 9ISTRIBUT!0N and 50-339 A JEi W Tf7F' C. Kim NRC & Local PDRs ACRS(10)
PD22 Reading Gray File Mr. W. L. Stewart S. Varga Vice President - Nuclear Operations G. Lainas Virginia Electric and Power Company D. Miller Post Office Box 26666 H. Berkow Richmond, Virginia 23261 OGC-WF L. Engle
Dear Mr. Stewart:
E. Jordan J. Partlow
SUBJECT:
SAFETY EVALUATION REPORT FOR ITEM 2.2 (PART 1) 0F GENERIC LETTER 83-28. EQUIPMENT CLASSIFICATION (PROGRAM FOR ALL SAFETY-RELATED COMPONENTS), FOR NORTH ANNA POWER STATION UNITSN0.1ANDNO.2(NA-182)(TACNOS.53693AND53694}
Generic Letter 83-28 Item 2.2.1 required licensees to describe in detail their program for classifying all safety-related components other than RTS components as safety-related on plant documents and in information handling systems that are used to control plant actuations that may affect these components.
By letters dated November 4,1983 and February 8,1985, Virginia Electric and Power Company (VEPC0) submitted responses to Generic letter 83-28. Item 2.2.1.
Our review of the VEPC0 submittals is documented in the enclosed NRC contractor's report (EG&G-NTA-7379) and in our enclosed Safety Evaluation Report which docu-ments our concurrence with the contractor's findings which finds the VEPC0 responses to be acceptable.
Therefore, we find Item 2.2.1 to be completed by this action.
In your response, you stated that the development of a new and more complete listing of safety-related components was in planning but no specific date for completion was provided.
In order that inspection-related scheduling may be addressed for this matter, we request that you provide a schedule for the com-pletion of the new listing and for implementation within 60 days of the date of this letter.
It is noted that both Items ?.2.1 and 2.2.2 of Generic Letter 83-28 have been followed by the NRC Technical Assignment Control (TAC) numbers 53693 and 53694 for NA-1&2, respectively.
Since Iten ?.2.2 remains open, we are closing out TAC numbers 53693 and 53694, and we will issue new TACs for NA-1&2 Item 2.2.2.
8803100022 800304 PDR ADOCK 05000338 P
r. _.. _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ - _ _ - _ _ _ _ _
?*:
d Mr. W. L. Stewart.
The reporting and/or recordkeeping. requirements contained in this letter affect fewer than'10 respondents; therefore, OMB clearance;is not required under P.L.96-511.
Sincerely, Leon'Engle, Project Manager Project Directorate'II-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation
Enclosures:
As stated cc w/ enclosures:
See next page
- See previous concurrence
- LA:PDII-2
- PM:PDII-2 D:
(@
DMiller LEngle:bg HB&4M 2/ /88 2/ /88
]Uq/88
Docket Nos. 50-338 DISTRIBUTION and 50-339 Docket File-C. Kim NRC & Local PDRs ACRS (10)
PD27, Reading Gray File Mr. W. L. Stewart S. Varga Vice President - Nuclear Operations G. Lainas Virginia Electric and Power Compaay D. Miller Post Office Box 26666 H. Berkow Richmond, Virginia 23261 OGC-WF.
L. Engle
Dear Mr. Stewart:
E. Jordan J. Partlow
SUBJECT:
SAFETY EVALUATION REPORT FOR ITEM 2.2 (PART 1) 0F GENTRIC LETTER 83-?8, EQUIPMENT CLASSIFICATION (PROGRAM FOR All.
SAFETY-RELATED COMPONENTS), FOR NOPTH ANNA POWER STATION, UNITS 1&P (NA-1&?) (TAC NOS. 53693 AND 53694)
Generic letter 83-28, Item 2.2.1 required licensees to describe in detail their program for classifying all safety-related components other than RTS components as safety-related for documents and in handling systems that are used to control
, plant actuations that may affect these componnits.
By letters dated November 4,1983 and February 8,1985, Virginia Electric and Power Company (VEPCO) submitted responses to Generic letter 83-?8, Item 2.?.1.
Our review of the VEPC0 subnittals is documented in the enclosed NRC contractor's report (EGAG-NTA-7379) and in our enclosed Safety Evaluation Report which docu-ments our concurrence with the contractor's findings which finds the VEPCO responses to be acceptable. Therefore, we find Item 2.7.1 to be completed by this action.
It is noted that both Items 2.2.1 and ?.2.? of Generic Letter 83-28 have been followed by the NRC Technical Action Control (TAC) numbers 53693 and 53694 for NA-1&P, respectively. Since Item 2.2.7 remains open, we are closing out TAC numbers 53693 and 5369A, and we will issue new TACs for NA-1&? Item 2.?.?.
Sincerely, Leon Engle, Project Manager Project Directorate II-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Pegulation
Enclosures:
As stated cc w/ enclosures:
See next page A,
L2 PM D:PDII-?
or LEn e:ba HBerkow 7/88 2/K/88' 2/ /88
Mr. W. L. Stowart North Anna Power Statier virginia Electric & Power Company Units 1 and ?
cc:
Mr. William C. Porter, Jr.
Atomic Safety and Licensing Appeal County Administrator Roard Panel i
Louisa County U.S. Nuclear Regulatory Comission l
P.O. Rox 160 Washington, DC ?0555 Louisa. Virginia ?3093 Fw ieral Administrator, Region II Michael W. Maupin, Esq.
U.S. Nuclear Reoulatory Comission Hunten and Williams Office of Executive Director P. O. Box 1535 for Operations Richmorri, Virginia 23212 101 Marietta Street N.W., Suite 2900 Atlanta, Georgir 30323 Mr. W. T. l.ough Virginia Corporation Commission Mr. F. W. Harrell Divisien of Energy Pegulation P. O. Box 402 P. O. Box 1197 Mineral, Virginia ?3117 Dichmond, Virginia 23209 Old Dominion Electric Concerative Ellyn R. Weiss. Esq.
c/o Executive Vice President Harmon, Weiss and Jordan Innsbrook Corporate Center 2001 S Street NW 4222 Cox Road, Suite 102 Washington, DC 20009 Glen Allen. Virginia 23060 Mr. J. T. Rhodes James B. Kenley, M.D., Comissioner Senior Vice President - Power Ope.
Department of Health Virginia Electric and Power Co.
109 Governor Street Post Office Box 26666 Richmond, Virginia 23219 Richmond, Virginia 23261 Fr. Patrick A. O' Hare Office o' the Attorney General Supreme Court Ruilding 101 North Pth Street Richmond, Virginia ?3219 Resident Inspector /Forth Anna c/o U.S. NRC Senior Resident Inspector Peute 2. Box 78 Mineral, Virginia 23117