Text
F-JUN E3 15N)
MEMORANDUM FOR: Carl H. Berlinger, Chief Generic Comunications Branch Division of Operational Events Assessment Office of Nuclear Reactor Regulation FROM:
Jack E. Rosenthal, Chief Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data
SUBJECT:
AE0D/T809:
BLOCKED THIMBLE TUBES / STUCK INCORE DETECTOR Enclosed is a technical review report on blocked thimble tubes / stuck detectors. You may wish to consider this subject for an information notice because of the recent events at Braidwood 1 and their potential for occurring at other PWRs.
M 88vowf by Jack E. Rosenthal, Chief Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data
Enclosure:
As Stated
Contact:
Mary S. Wegner 492-7818 Distribution:
R0AB R/F MTaylor, EDO JRosenthal JPartlow, OSP MChiramal CHel temtes MWegner Edordan VBenaroya MWilliams KBlack
- SEE PREVIOUS CONCURRENCES Ib
'i.b 4
- R0AB:DSP:AE0D
- ROAB:DSP:AE0D AB:DSP:AE0D DSP:AE0D MWegner MChiramal Rosenthal VBenaroya 6/ /88 6/ /88 6//$88 6/J1188 gg7ioB!lSki' P
MEMORANDUM FOR: Carl H. Berlinger, Chief Generic Comunications Branch Division of Operational Events Assessment Office of Nuclear Reactor Regulation FROM:
Jack E. Rosenthal, Chief Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation of Operational Data
SUBJECT:
AE00/T809: -BLOCKED THIMBLE TUBES / STUCK INCORE DETECTOR s
Enclosed is a technical review report on blocked thimble tubes / stuck detectors. You may wish to consider this subject for an information notice because of the recent events at Braidwood 1 and their potential for occurr.ing at other PWRs.
Jack E. Rosenthal, Chief Reactor Operations Analysis Branch Division of Sa'fety Programs Office for Analysis and Evaluation of Operational Data
Enclosure:
As Stated
Contact:
Mary S. Wegner 492-7818 I
Distribution:
ROAB R/F JRosenthal MChiramal MWegner fy:w'jk js d R0AB G;;':?.EnD ROAB:DSP:AE00 R0AB:DSP:AE00
/i""P MWeg/8'g MChiramal\\w JRosenthal ner 6/,s 6/g/88 6/ /88
.-