ML20196G082

From kanterella
Jump to navigation Jump to search
Notice of Environ Assessment & Finding of No Significant Impact Re Util 871028 Application for Change to Tech Specs for Boron Acid Concentration in Refueling Water Tank,Safety Injection Tanks & Boric Acid Makeup Tanks
ML20196G082
Person / Time
Site: Arkansas Nuclear 
Issue date: 02/29/1988
From: Calvo J
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20196G087 List:
References
NUDOCS 8803040351
Download: ML20196G082 (4)


Text

.

7590-01 UNITED STATES NUCLEAR REGULATORY COMMISSION ARKANSAS POWER AND LIGHT COMPANY ARKANSAS NUCLEAR ONE. UNIT 2 C0CKET NO. 50-368 NOTICE OF ENVIRONMENTAL ASSESSMENT AND Flh0INGS OF NO SIGNIFICANT IMPACT l

The U.S. huclear Reguletory Commission (the Commission) is considering issuance of an amendment to the Technical Specifications (TSs) for Arkansas Nuclear One. Unit 2 (ANO-2) located at Russellville. Arkansas.

t ENVIRONMENTAL ASSESSHENT Identitication of Proposed Action: By letters dated October 28. 1987 (2CAN108704 and 2CAN108705). Arkansas Power and Light Company (AP&L. the t

licensee) requested a change in the plant technical specifications (TSs) to reflect a decrease in the boron concentration required in the boric acid makeup tanks (BAMTs). and an increase in the boron concentrv.!cn required for the refueling water tank (RWT) and the safety injection tanks (SITS). Additional information regarding time for loss of shutdown margin was provided in the licensees' letter of January 19.1988(2CAN016801).

i The BAMTs are presently required to contain between 5.0 and 12.0 weight percent boric acid concentration. The proposed change would permit boric acid concentrations of between 2.5 and 3.5 weight percent. Similarly. the RWT and SITS are now required to have a boron concentration between 1731 and 2250 ppm of boron. The proposed change will increase the level to between 2500 ppm and 3000 ppm.

8803040351 880229 PDR ADOCK 05000368 P

PDR

. Notice of Consideration of Issuance of Amendment to Facility Operating License and Opportunity for Prior Hearing regarding the proposed changes to the TS, wea oublished in the Federal Register on December 21,1987(52FR48348 and 52 FR48349).

Need for Proposed Action:

The proposed TS changes are needed because the licensee will be using extended cycle cores at ANO-2. The proposed changes to the TS will provide the safety and operational enhancements specifically suited to use of the extended cycle cores, i

Environmental Impact of_ the Proposed Action _: The proposed increase in boron concentration in the RWT and SITS was censidered for the applicable accident analyses in chapter 15 of the Final Safety Analysis Report. The appropriate criteria are cet and in some analyses, there are slight increases in the margin of safety due to the minimal increases in the reactor coolant system boron i

concentration. The contents of the BAMTs are not considered in accident mitigation but are assumed to be added to the containment sump inventory in the evaluation of long term emergency core cooling system performance. The decrease in the boron concentration of the BAMTs almost exactly offsets the boron increases in the RWT and SITS. Consequently there is, either minimal or no change in the potential for boric acid precipitation, spray and sump pH values, iodine removal capabilities, and containment corrosion characteristics.

Therefore the proposed changes will not increase to greater than previously determined, the probability of accident and post-accident radiological releases, nor otherwise affect radiological plant effluerts. The Comission concludes that there are no significant radiological environmental impacts associated with the proposed TS changes.

~

. With regard to potential non-radiological impacts, the proposed TS changes involve features located entirely within the restricted area as defined in 10 CFR Part 20. They would not affect non-radiological plant effluents and would have no other environmental impact.

Therefore, the l

Commission concludes that there are no significant non-radiological l

l environmental impacts associated with the proposed exemption.

Alternatives to the Proposed Actions:

The principal alternative to the proposed actions would be to deny the requested TS changes.

It has been concluded that there is no measurable impact associated with the proposed license amendment; any alternatives to the license amendment will have either no environmental impact or greater environmental impact.

Alternative Use of Resources: This action does not involve the use of any resources beyond the scope of resources used during normal plant operation.

Agencies and Persons Consulted: The Commission's staff reviewed the licensee's safety analysis and changes to the TSs that support the proposed amendment.

The staff did not consult other agencies or persons.

l l

FINDING OF NO SIGNIFICANT IMPACT Based upon the foregoing environmental assessment, the Commission 1

concluded that the proposed action will not have a significant effect on the quality of the human environment. Accordingly, the Commission has determined not to prepare an environmental impact statement for the proposed license l

amendment.

l

. For further details with respect to this action, see the applications for license amendment dated October 28, 1987, as supplemented by letter dated January 19, 1988. Copies are available for public inspection at the Commission's Public Document Room, 1717 H Street, N.W., Washington, D.C.

20555, and at the local public document room located at the Tomlinson Library, Arkansas Tech University, Russellville, Arkansas 72801.

Dated at Rockville, Maryland, this 29th day of Februa ry

,1988.

t FOR THE NUCLEAR REGULATORY COMMISSION i

[-

Ddw i

,rv~~G Jose A. Calvo, Director Project Directorate - IV Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation l

l l

l I

t I

f

_