J Engineering November 19,1998 IEN/NRC 9811-01 U.S. Nuclear Regulatory Commission ATTN: Charles D. Petrone Mail Stop: 0-12D3 Washington, D.C. 20555-0001

SUBJECT:

Draft Information Notice Regarding I.caks in the Emergency Diesel Generator Lube Oil and Jacket Water Piping Fairbanks Morse Owners' Group Comments

{

Dear Mrl Petrone,

Thank you fo'r'proViding IEN Engineering a copy of the seco'nd draft of the subject Draft Infoiilation Notice'for comments. Below, please ' find several comments on the subject Draft Information Notice by the Fairbanks Morse Owners' Group.

Comment 1 The Draft Information Notice identifies that Vermont Yankee, Millstone Unit 2 and Crystal River have experienced leaks in the lube oil and jacket cooling water system piping of their Fairbanks Morse EDGs. I am not aware of leaks in the jacket cooling water system piping resulting from degraded or partial penetration welds on the diescl generators of these plants. Crystal River found partial penetration welds on the new cooling water system piping for their planned upgrade of the engines -(this upgrade was cancelled).

However, it is my understanding there were no leaks found in this piping.

It is recommended the reference to leaks in the jacket cooling water system piping for these three operating units be removed from the verbiage in the Draft Information Notice.

Comment 2 The first full sentence on the last page of the Draft Information Notice reads "Therefore licensees should not assume that the successful completion of the l-startup and preoperational test programs will ensure that all potential weld l

O l

" problems were identified".' -This sentence may be interpreted to mean that all

' - welds on the' skid are not' demon'strated to me'et the des.i;n'and licensing bases of

- the operating units. It is assum-d this is not'the intent of this sentence. Itis Cg "reebmmended that this sentence be emoved from the Draft Information Notice.

4 9812070069 991119 i

PDR ADOCK 05000271 h 8

G PDR "a 19 uarden Road, Marblehead, MA 01945 g &Q

[}(

ej

,, o c (781)6319219 Fax:(781)6319032

,q _! = m p E-Mail:ieneng@aol.com

..'m-t

,n

~,,

IEN/NRC 9811-01, dated November 19,1998 E

Engineering Comment 3 The last sentence of the last full paragraph on the third page of the Draft Information Notice reads "In

addition, plants such as

..............................., but who have subsequently performed testing and replaced most of the vibration-prone sections of the piping, are not subject to the concerns described in this information notice". This sentence implies that only those who have performed both testing and replacement of the vibration-prone sections of piping are not subject to the concerns in the Draft Information Notice.

We recommend that the verbiage be changed to "In addition, plants such as

........................., but who have subsequently performed testing and taken appropriate actions or r:placed most of the vibration-prone sections of the piping, are not subject to the concerns described in this information notice" so that those who have performed either testing or replacement of piping are not subject to the concerns of the Draft Information Notice.

Another alternate would be to replace the words " replaced most of" in this sentence with the words "or taken appropriate action concerning" The above comments on the subject Draft Information Notice is respectfully submitted on behalf of the Fairbanks Morse Owners' Group.

IEN Engineering will be pleased to discuss the contents of the subject Draft Information Notice and provide clarifications on the above comments, as well as clarifications of comments previously submitted, at your request. On behalf of the Fairbanks Morse Owners' Group, I appreciate the opportunity to review this Information Notice and submit comments on it.

If you have any questions regarding the above, please contact me at (781) 631-9219.

Sincerely, Y&k.

?W Harold E. Epstein IEN Engineering l

I 2

l 1

s, (L11d 7c' Decater 3,1998 i

l I

NOTE T0: File Please place the attached doctment in the PDR. If you have any questions, contact Charles Petmne.

t W. Petrone can be reached at 415-1027.