l December 6, 1988 4-Docket Nos. 50 2P4/260/296 Mr. Oliver D. Kingsley, Jr..
Senita Vice President, hoclear Power Tennessee Valley Authority 6N 38A Lookout Place a
1101 Varket Street Chattanooga, Tennessee 37402 28G1
Dear Mr. Kingsley:
SUBJECT:
NRC SEISMIC AUDIT 9R BROWNS FEDRY 1
The NRC will perfom an audit of seismic triated do ner.+atirn 0ecember 19-23,
~
1983 in Knoxville. The objective and scope of ?. bis < idtt e identified in a
the enclo:ure.
An exit mee'ing with you or 'whars J.' four ;taff will be conducted. The date and time of this exit meetiac vill be arranged b tween Mr. Patrick Carter of your staff and Mr. Thonas Cheng o' +.he OSP staff.
r l
Project Manager, G. Gears at (301)g this activity, please contact the. NRC If you have any questions regardin i
492-3767.
Sincers'/,
Original signed by Suzanne Bla
, Assistant Director i
i I
for Projects i
1/A Projects Division Office of Special Projects
Enclosure:
PRA Audit Scope I
i cc w/ enclosure:
See next page Distribution
..N' M. Sims i-I NRC PDP.
G. Gears Local PDR D. Moran Projects Reading J. Rutberg l
OSP Reading D. Crutchfield j
B. c imes l
JPartlow r
SRichardson E..;ordan 1
SBlack ACRS(10)
BDLiaw GPA/PA j
i FMcCoy GPA/CA I [h\\
F t
WSlittle EChelliah b
I i
BFN Rdg.
i J
(.o)
~ ~ '
TVA:AD/P i
TP/.-.::
0FC :05P:TVA/LA :05P:TVA/FM
- T
[
.8 T
- SR1ac -
- NAME
- MSims a....:...........:...,y......:...........:.. 7.......:...........:...........:...........
l DATE :12/K /88
- 12/ % 8.
- 12/ V/88
- 32/5 /88 l 0FFICIAL RECORD COPY es121202s7 es12o3 PDR ADOCK 05000259 P
PDC j
6 Mr.- Oliver J. Kingsley, Jr. Browns Ferry Nuclear Plant ec:
General Counsel Regional Administrator, Region II Tennessee Valley Authority U.S. Nuclear Regulatory Comission 400 West Sumit Hill Drive 101 Marietta Street, N.W.
Atlanta, Georgia 30323 E11 B33 Xnoxville, Tennessee 37905 Resident Inspector / Browns Ferry NP Mr. R. L. Gridley U.S. Nuclear Regulatory Comission Tennessee Valley Authority Route 12. Box 637 SN 157B Lookout Place Athens, Alabama 35611 Chattanooga, Tennessee 37402-2801 Mr. C. Mason Dr. Henry 4yers Science Advisor Authority Committee on Interior Tennessee Valle) lear Plant and Insular Affairs Browns Ferry Nuc 0.0. Box 2000 U. S. ilouse of Representatives Decatur, Alabama 35602 Washington, D.C.
20515 l
Tennessee Valley Authority Mr. P. Carter Rockville Office Tennessee Valley Authority 11921 Rockville Pixe Browns Ferry Nuclear Plant Suite 402 P.O. Box 2000 Rockville, Maryland 20852 Decatur, Alabama 35602 Mr. D. L. Williams Tennessee Valley Authority 400 West Sumit Hill Drive W10 B85 Knoxville, Tennessee 37902 Chairman, Li'nestone County Comission l
P.O. Box 188 Athens, Alabama 35611 Claude Earl r x, M,0.
o State Health Officer 1
State Department of Public Health State Office Building Montgomery Alabama 36130
)
t -'l.
rg,.
ENCLOSURE l
PRA AUDIT RROWNS FERRY Audit Topic:
Downs Ferry Seismic Audit i
Date:
December 19-23, 1988 l
NRC Audit T. Cheng(NRC Contractorl T. Tsai Members:
Objective:
To obtain additional, detailed information to assist NRC in writing its Safety Evaluation:
Audit Scope:
(1) Comparison of new ARS versus original ARS based on El Centro ground motion time history.
(?) ARS generated for the soil founded structures, including
+
modeling techniques (soil sprinos, etc.) consideration of l
soil ampiification effects (soil amplification factors),
coupling of horizontal and vertical responses, etc.
(3) Mass participation to the structural responses.
(4)
Damping of steel structural members inside dyrwell (1% versus 2%).
(5)
Definition of ZPA of the new ARS.
I r
9 l
L l
i l
I l
?
i I