t.

i 1987 ANNUAL REPORT FOR WHOLE 800Y EXPOSURE I

4 i

t I

r 1

I l

s I

L i

l l

1 9

1 l

l I

r i

i 4

8803010457 890224 PDR ADOCK 05000302 R

PDR 4

e,

~,.

.--..,--,r,,,v..-,,---

,,-n-,,,,

,,.-.,,,m-_,,,,

,,-,wv.n,,,,.-w... _,, -,.

ye,

-ww..,,

WHOLE BODY EIPOSURE FOR CALENDER YEAR 1987 Licencee Reporting ( Name and Address)

NRC license No(s)

FLORIDA POWER CORPORATION DPR-72 CRYSTAL RIVER UNIT 3 PO B0X 1240 CRYSTAL RIVER. FL 32629 O

If personnel monitoring was not requird to be provided to any individual during the year, checking this box will constitute a negative report indicating that such personnel monitoring was not required.

OTHERW ISE, COMPLETE THE FOLLOWING TABLE:

Estimated AnnualWhole Body Number of Individuals Exoosure Ranaes * (Rems) in Each Range No Measurable Exposure.......

.1029 Less Than 0.100..

..483 0.100 - 0.250...

...308 0.250 - 0.500..

...243 0 500 - 0.750..

..127 0.750 - 1.000.

.91 1.000 - 2.000.

.122 2.000 - 3.000..

.. 5 3.000 - 4.000.

.0 4.000 - 5.000..

.0 5.000 - 6.000...

..0 6.000 - 7.000..

.0 7.000 - 8.000....

.0 8 000 - 9.000..

.0 9.000 - 10.000....

.0 10 000 - 11.000.

.0 11.000 - 12.000.

.0 Exposure GreaterThan 12.000.

.0 TOTAL NUMBER OF INVIDIDUALS REPORTED 2413 The above information is submitted for the total number of individuals for whom personnel monitoring was: (check one)

O required under 10 CFR 20.202(a) or 10 CFR 34 33(a) during the calendar year.

I 3 provided during the calendar year.

' Individual values exactly equal to the values separating exposure ranges shall be reported in the higher range.

v' s

FLORIDA POWER CORPORATION CRYSTAL RIVER UNIT 3 P.O. BOX 1240 CRYATAL RIVER, FLORIDA LICENSE: DPR.72 TECHNICAL SPECIFICATION JOB-DOSE CATEGORY INFORMATION REPORT YEAR: 1987 Work Job Function Function Utl.

Sta. Cntr.

Utl.

Sta.

Cntr.

3E33333333333333333333E33333333333333355EE33333333333333333333 Reactor Maint.

0 2

6 0.335 1.613 4.673 Ops.

Ops.

0 25 0

0.011 7.007 0.060 and HP & Lab 0

8 60 0.000 2.346 29.688 Surv.

Supv.

0 4

2 0.064 1.389 0.996 Eng.

0 0

2 0.123 0.149 0.434 3333333333333333333333333333553EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE Routine Maint.

75 139 316 68.456 51.638 166.586 Plant Ops.

0 25 1

0.000 8.594 1.038 Maint.

HP & Lab 0

22 73 0.000 9.548 32.236 Supv.

0 5

30 0.000 3.369 14.497 Eng.

3 3

38 1.029 0.874 30.930 E335535353E3333533555EE3533333555553333555E33543E333333333333E In-Maint.

0 1

15 0.024 0.180 4.131 service ops.

0 7

0 0.000 2.052 0.000 Insp.

HP & Lab 0

1 2

0.000 0.110 0.823 Supv.

0 2

1 0.005 0.242 0.347 Eng.

0 0

10 0.070 0.031 4.445 33333333333535333333333333355333E353E333333333333353555333E53E Special Maint.

0 0

0 0.000 0.000 0.000 Plant Ops.

0 0

0 0.000 0.000 0.000 Maint.

HP & Lab 0

0 0

0.000 0.000 0.000 Supv.

0 0

0 0.000 0.000 0.000 Eng.

0 0

0 0.000 0.000 0.000 3333333333333333F333335333333EE3B333333333335535E3333333355555 Waste Maint.

1 9

3 0.543 4.428 1.047 Proc.

Ops.

0 0

0 0.000 1.666 2.309 HP & Lab 0

1 7

0.000 1.243 1.547 Supv.

0 0

0 0.000 0.000 0.000 Eng.

0 0

0 0.000 0.000 0.000 E3333333333333333333335555555533333333333333333333EE5233533335 Re-Maint.

50 13 1

13.853 2.970 0.373 fuel Ops.

0 0

0 0.000 0.059 0.000 HP & Lab 0

0 2

0.000 0.151 1.360 Supv.

0 5

2 0.098 1.376 0.927 Eng.

0 0

11 0.000 0.137 2.869

=+=+=+=+=+=+=+R+=+=+=+=+=+S+=+=+=+=+=+E+=+=+=+=+=+=+=+=+E+=+=+

Sub Maint.

126 164 341 83.211 60.829 176.810 Totals ops.

0 57 1

0.011 19.378 3.407 HP & Lab 0

32 144 0.000 13.398 65.654 Supv.

0 16 35 0.167 6.376 16.767 Eng.

3 3

61 1.222 1.191 38.678

++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

Grand Total 129 272 582 84.611 101.172 301.316

--