Forwards Response to NRC 990510 RAI Re NMP 981116 Application Proposing Changes to TSs to Provide Reasonable Assurance That Coupled neutronic/thermal-hydraulic Instabilities Were Detected & Suppressed in NMPN-1 Reactor
ML20196E923
Person / Time
Site: Nine Mile Point 
Issue date: 06/21/1999
From: Abbott R
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NMP1L-1440, TAC-MA4218, NUDOCS 9906290053
Download: ML20196E923 (8)


Text

,

NiagarahMohawk' l

Richard R. Abbott Pho'ie: 315.3nm2 vice President June 21,1999 Fax: 315.349.4417 j

Nuclear Engineering NMP1L 1440 k

l

{

l U. S. Nuclear Regulatory Commission Attn: Document Control Des.k Washington, DC 20555 RE:

Nine Mile Point Unit 1 Docket No. 50-220 DPR-63

Subject:

Requestfor AdditionalInfonnation Reganting Pmposed Arnendment on 11tennal-flydmulic Stability, Nine Mile Point Nuclear Station, Unit No.1 (TAC No. MA4218)

Gentlemen:

By letter dated November 16,1998, Niagara Mohawk Power Corporation (NMPC) submitted I

an application to change the Nine Mile Point Unit 1 (NMPI) Technical Specifications. These changes were proposed to provide reasonable assurance that coupled neutronic/ thermal-hydrauli; instabilities were detected and suppressed in the NMP1 reactor. By letter dated May 10,1999, the NRC requested additional information regarding our November 16,1998 Application. The Attachment to this letter provides this information.

Sincerely, th&

l 9906290053 990621 Richard B. Abbott PDR ADOCK 0500 0

Vice President Nuclear Engineering RBA/JMT/ kap Attachment xc:

Mr. H. J. Miller, NRC Regional Administrator Mr. S. S. Bajwa, Section Chief PD-I, Section 1, NRR Mr. G. K. Hunegs, NRC Senior Resident Inspector Mr. D. S. Hood, Senior Project Manager, NRR Mr. John P. Spath NYSERDA 286 Washington Avenue Ext.

j Albany, NY 12203-6399 Records Management j

Nine Mile Point Nuclear Station R0. Box 63, Lycoming, New York 13093-0063 + www nimo com I

9 e

e 1

I ATTACHMENT t

m.

ATTACHMENT RFDUEST FOR ADDITIONAL INFORMATION I

REGARDING PROPOSFn TECHNICAL SPECIFICATION CHANGE CORE THERMAI HYDRAULIC STABILITY NIAGARA MOHAWK POWER CORPORATION NINE MIT R POINT NUCI FAR STATION. UNIT NO.1 DQCKET NO. 50-270 QUESTION Reactor Systems Bmach 1.

Provide a schematic showing the approved F111A region versus the power / flow restriction region. Describe the relationship in terms of the necessity of the increment of 2 % for the upper APRMflow-blased neutronfha scram setting and 7% for APRM rod block trip settings. Justify that these proposed TS changes are still within the approved ranges of the NMP1 stability long-term solution Hproposed in GENE-A13-00360-02.

Remonse 1: to this Attachment provides a schematic showing the Extended Load Line Limit Analysis (ELLLA) region versus the power / flow restriction region.

Our November 16,1998 submittal proposed essentially two changes to the Nine Mile Point Unit 1 (NMP1) Technical Specifications (TSs). Specifically, changes were proposed to the APRM flow-biased neutron flux scram and rod block settings in the high flow region and low flow region of the power / flow map. In the high flow region of the power / flow map, Niagara Mohawk Power Corporation (NMPC) proposed a 2% increase and 7% increase in the analytical flow-biased scram and control rod block limits, respectively. This increase was proposed to allow plant operation in the previously approved ELLLA region.

NMP1 is currently restricted from full use of the ELLLA region of the power / flow map because of the setpoints for the flow-biased rod block, The setpoint methodology used assigns a penalty to account for drift of the power and flow measuring instruments. This penalty reduces the as-left setpoints of the rod block which causes it to fall into the allowable ELLLA region. Consequently, NMP1 is forced to operate a; higher core flows to avoid rod block alarms. Full use of the ELLLA region will allow for optimum core power distributions throughout the operating cycle and a gain in cycle energy. Operation in the ELLLA region was approved by Amendment No. 92 dated March 24,1987.

The current values of the APRM flow-biased neutron flux scram end rod block settings are 120% and 110%, respectively (i.e., a 10% margin between the scram and rod block settings currently exists). Prior to our November 16,1998 TS Application, an analysis had been

~

1 I

i

^.

performed to support a 2% increase in the APRM flow-biased scram analytical limit.

Accordingly, a new scram limit of 122% is proposed. Regarding the control rod block setting, calculation demonstrated that a 5% margin between the scram and rod block limits was acceptable (i.e., 122 %-5 % = 117%). The proposed control rod block setting of 117%

represents the 7% increase from the current value of 110%.

In the low flow region of the power / flow map, more conservative TS APRM flow-biased scram and control rod block setpoints were proposed. The scram value calculated will limit the oscillation magnitude assuring that the plant MCPR safety limit value is not exceeded. As shown on the attached schematic, the APRM flow-biased setpoints are based on GENE-A13-00360-02.

NEDO-32465-A, Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Applications, will be added to TS.6.9.1.f, Core Operating Limits Report. TS 6.9.1.flists those documents which describe the analytical methods used to determine core operating limits. MCPR operating limits will be reviewed each reload which will assure the setpoint derived in GENE-A13-00360-02 will prevent the MCPR safety limits from being exceeded.

Questinn?

2.

Describe the relationship between the supporting document, NEDC-32696P, and the proposed TS changes. Since this topical report has not been submitted to the NRCfor review / approval, explain why you believe it can, nevenheless, be used to support the proposed license amendment.

Response

As noted in our TS submittal, NMP1 is an Option II plant in which the existing quadrant-based APRMs are capable of initiating a reactor scram due to reactor instabilities. However, plant-specific analysis (i.e., GENE-A13-00360-02) indicated a change to the APRM flow-biased neutron flux scram would be required to limit the oscillation magnitude and limit the change in Critical Power Ratio (CPR). To facilitate this change and the other proposed TS changes, a more complex trip card was required. NMPC selected a card similar to the FCTR cards described in NEDC-32339-A, Supplement 2, " Reactor Stability Long-Term Solution:

Enhanced Option I-A Solution Design.'

As noted in our submittal, Attachment C, Page 2 of the Introduction, and our letter dated October 21,1998, as of September 22,1998, the APRM analog trip biased units were replaced with new digital FCTR cards under 10CFR50.59 and are currently capable of initiating a scram in the event of reactor instabilities. NEDC-32696P, Reactor Stability Long Term Solution: Option II Solution Design, was prepared by GE to evaluate the differences between the FCTR cards used for the Enhanced Option I-A solution option and the cards used for Option II at NMP1 and to document their acceptability. As indicated in NEDC-32696P, the card design is based on the previously NRC approved EI A FCTR card design and the card

-2

design differer.ces allow the Option II FCTR card to be enveloped by the EI A solution design safety evaluation report. The discussion of NEDC-326%P was provided in the Introduction section of our application only to provide a historical perspective on the installation of the FCTR cards which was performed under 10CFR50.59. In summary, NEDC-32696P documented the review of the physical aspects of the new FCTR card for use at NMP1 and to support installation under 10CFR50.59, but was not used to support the proposed changes to TSs.

Quesdan:

3.

Provide the technical basisfor changing the channel accuracy in the TSfrom 2 % to

+2%/-1.9%. Discuss the sigmfcance ofthis new expression ofuncertainty with respect to the reactorpower operation.

Response

NMPC requested that General Electric Nuclear Energy (GENE) recalculate the APRM flow-biased trip setpoints for implementing the Stability Long-Term Solution Option II Design and to allow plant operation in the ELLLA region. In response, GENE performed an APRM setpoint calculation per NEDC-31336, GE Instrument Setpoint Methodology, Class III October 1986, which determined the allowable values and trip setpoints for both the flow-biased scram and flow-biased rod block trip unit functions. Once the setpoints were determined, the scram

' od block curves were " burned" into the memory chips of the FCTR cards. However, a discrepancy in the calculation required that NMPC either replace the memory chips or take a

. penalty in channel accuracy. NMPC elected to take a penalty in the tolerance allowed by TS

_ (i.e., the 2% allowance) between APRM channel readings and the power value calculated by heat balance during reactor operation, which is then used to make adjustments to the APRM channel. This decision was determined by NMPC to be acceptable 6.ce the TS allowed difference between the APRM channel and rated thermal power is one of the uncertainty values used in the APRM channel calibration'setpoint calculation for Stability long-Term Solution-Option II at NMPl.

This penalty to APRM channel accuracy has no impact on the power operation of the reactor.

A channel accuracy tolerance of -1.9% is more conservative than -2% because it reduces the margin of error that the APRM trip setpoint can be in the negative direction. Therefore, it reduces the probability that reactor power will be above the APRM trip setpoint (i.e., with a channel calibration tolerance of-2%, reactor power can actually be at 102% of the trip setpoint when the APRM channel detects 100%. With a channel accuracy tolerance of-l.9%,

reactor power will be at 101.9% ofits setpoint when the APRM channel reading is 100%).

Additionally, when.the technicians perform gain adjustments to the APRM channels, the tolerances allowed by procedure at NMP1 are limited to no greater than +2%/-0%. This procedural control provides additional assurance that the APRM trip setpoints always remain enveloped by the instrument calibration calculation that is documented in the design and licensing basis for NMPI, which in turn, ensures that the TS limits will not be exceeded.

3

m Question:

' Flutrical & Intrunwnfation and Controls Branch 4.

Please supplement your submittal ofNovember 16,1998, to address the list ofcriteria in Supplemertt 2 of Topi:al Report NEDC-32339P-A, ' Reactor Stability Long-Term Solution: Enhanced Option I-A, Solution Design. " Specifcally, confrm that the plant-specipe environmental conditions (temperature, humidity, pressure, sdsmic, and electromagnetic compatibility) are enveloped by the EIA equipment environmental quahpcation values.

Response

As previously noted, NMP1 is an Option II plant in which the existing quadrant-based APRMs i

are capable of initiating a reactor scram due to reactor instabilities. However, plant-specific -

analysis (i.e., GENE-A13-00360-02) indicated a change to the APRM flow-biased neutron flux scram would be required to limit the oscillation magnitude and limit the change in CPR.

To facilitate this change and the other proposed TS changes, a more complex trip card was required. NMPC selected a card similar to the FCTR card described in NEDC-32339-A for Option I-A plants.

As noted in our TS submittal and letter dated October 21,1998, the APRM analog trip biased units were replaced with new digital FCTR cards under 10CFR50.59. As part of the modification process, it was confirmed that the card's environmental qualification values enveloped plant-specific environmental conditions (temperature, humidity, pressure, seismic, and electromagnetic compatibility).

Question:

S.

Please clarify whether you intend to apply the " shakedown " period allowedfor this equipment. (We note that the licenseefor the Brunswick plant installed the EJA and needed to make plant-specifc revisions to the equipment to preven' spurious trips and alarms.)

Response

As discussed in Responses 2 and 4, the equipment (i.e., the digital FCTR card) was installed as of September 22,1998 and is currently capable of initiating a scram in the event of reactor instabilities. The cards have rtm satisfactorily since completion of this modification. No i

" shakedown" period is planned following implementation of this TS.

4

i i

0 i

1 ENCLOSURE

l l

l l

l

~

'h

_i E! [l

,a l

=

5li

!! !!lIllllf l

hh I

I 9

IIi

!l

!!jll hll E!

lij!!!f"jglls!'ili s

l~1'!jb!i R9 I

i.

l 11 li!!

!.i jL-ri

! e~

2

- 'p il;pieill&olilslce 1

!i

. Il I!i!

j!!l1lih=!I!!!!iiiiiii ll ia ili il ~

l Pl

!2 ul-

~8 s

'1 IlL'tl II 15L,L 1 Fs.)

l i.

o, 1

~

uma suu ygj l

vi; Il Eiji

(

Z

~

~

.g Egl

_ l_

i j!

k

'I i 11 si

[tila> =

a

-g j

y

(

-O-5 s;l

-g ll Lg-l M-

11 I

~

~~

_a v,n

_w I

I II'

,3 E

i B

3 3

g F

s 2

e a

e a

a a

WI

( 031VW 30 *. I d3M0d 3W03

/

l l

l l

I l

~

~

~

_