Notice of Violation from Insp on 881017-21.Violation Noted: Corrective Actions Taken Re Potential for Mixed Grease in Limitorque Operators Required to Be Environmentally Qualified,Inadequate
ML20196E440
Person / Time
Site: Summer 
Issue date: 12/02/1988
From: Herdt A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20196E439 List:
References
50-395-88-23, NUDOCS 8812090342
Download: ML20196E440 (1)


Text

-

ENCLOSURE 1 NOTICE OF VIOLATION South Carolina Electric and Gas Company Docket No. 50-395 V. C. Sumer, Unit 1 License No. NPF-12 During the Nuclear Regulatory Comission (NRC) inspection conducted on Octobei 17-21, 1988, a violation of NRC requirements was identified.

In ment Actions," 10 CFR Part 2 Appendix C (1988)y and Procedure for NRC Enforce-accordance with the "General Statement of Polic

, the violation is listed below:

10 CFR 50, Appendix B, Criterion XVI, Corrective Action, requires that conditions adverse to quality, such as failures, malfunctions, deficiencies, deviations, defective material and equipment, and non-conformances be promptly identified and corrected.

Contrary to the above, corrective actions taken in response to SER 7-84 (documented on NCN 1673), regarding the potential for mixed grease in limitorque operators required to be environmentally qualified, were inadequate in that all affected operators were not evaluated for the problem.

Consequently, on January 14 and 25, 1988, at least eight additional operators were identified as potentially having mixed grease after NCN 1673 was closed in 1987.

At the time of the inspection at least three (3) of the operators were confirmed to have mixed grease.

This is a Severity Level V violation (Supplement I).

FOR THE NUCLEAR REGULATORY COMMISSION lan R. Herdt, Chief Engineering Branch Division of Reactor Safety Dated at Atlanta, Georgia this g day of 1988 m29Ba8! 8%TW G