Summary of Operating Reactors Events Meeting 88-47 on 881129.List of Attendees,Events Discussed & Significant Elements of Events,Two Events Suggested for long-term Followup & Summary of Reactor Scrams Encl
ML20196B982
Person / Time
Site: Dresden, Nine Mile Point, 05000000
Issue date: 12/01/1988
From: Lanning W
Office of Nuclear Reactor Regulation
To: Rossi C
Office of Nuclear Reactor Regulation
References
GL-88-15, OREM-88-047, OREM-88-47, NUDOCS 8812070119
Download: ML20196B982 (14)


Text

'.*

DEC 91 M MEMORANDUM FOR:

Charles E. Rossi, Director Division of Operational Events Assessment FROM:

Wayne D. Lanning, Chief Events Assessment Branch Division of Operational Events Assessment

SUBJECT:

THE OPERATIND REACTORS EVENTS MEETING November 29, 1988 - MEETING 88-47 C '.ovember 29, 1988, an Operating Reactors Events meeting (88-47) was held to brief senior managers from NRR, AE00, OSP, Commission Staff, and Regional Officos on events which occurred since our last meeting on November 22, 1986.

The list of attendees is included as Enclosure 1.

The events discussed and the significant elements of these events are presented in Enclosure 2. presents two events suggested for long-term followup and a sumary of reactor scrams.

One significant event was identified for input to NRC's performance indicator program.

Wayne D. Lanning, Chief Events Assessment Branch Division of Operational Events Assessment

Enclosures:

As ste.ted cc w/ Encl.:

See Next Page DISTRIBUTION g'/

Central File EAB Reading File Circulating Copy. EAB Staff gro3 9

MLReardon, EAB

~ lff J

fi [,j)// M, y) y 00udinot. EAB I

'j LKilgore, SECY

.h l'/

PDR

./

g

~.

\\

, IEi rf q

1lli A

OFC :EA /,

C:E RB/01 m:

....:........l....:............:............:............:............:...........

NAME :MLReardon

WDLanning DATE :11/ 74/88
1D

/88 i

l OFFICIAL RECORD COPY G812070119 881201 PDR ORG NRRB PDC

1,

cc:

L T. Murley, 12G-18 B. Siegel, 130-1 F. Miraglia, 12G-18 D. Muller, 13D-1 J. Sniezek, 12G-18 M. Haughey, 148-2 E. Jordan, AE00 R. Capra, 148-2 I

J. Taylor, 17G-13 E. Beckjord, NL-007 W. Russell, RI M. Ernst, RII B. Davis, RI!!

R. D, Martin, RIV l

J. 3. Martin, RV W. Kane, RI L. Reyes, RI!

E. Greenman, RI!!

L. Callan, RIV D. Kirsch, RV f

S. Varga, 14E-4 t

D. Crutchfield, 13A-2 i

B. Boger, 14A-2 G. Lainas, 14H-3 G. H91ahan, 138-4 L. Shao, 8E-2 J. Partlow, 70-24

[

B. Grimes, 9A-2 F. Congel, 10E-4 E. Weiss, AE00 T. Martin, EDO J. Guttmann, SECY A. Thadani, 7E-4 S. Rubin, AE00 i

J. Forsyth, INP0 R. Barrett, 10E-2 M. Harper, MNBB 4210 t

4

g. n o, 6

'o UNITED STATES

/*

8'

?.

NUCLEAR REGULATORY COMMISSION e

WAS HIN3 TON, D, C. 20655

'%,.....,/

DEC 011El MEMORANDUM FOR:

Charles E. Rossi, Director Division of Operational Events Assessment FROM:

Wayne D. Lanning, Chief Events Assessment Branch Division of Operational Events Assessment

SUBJECT:

THE OPERATING REACTORS EVENTS MEETING November 29, 1988 - MEETING 88-47 On November 29, 1988, an Operating Reactors Events meeting (88-47) was held to brief senior managers from NRR, AE00, OSP, Commission Staff, and Regional Offices on events which occurred since our last meeting on November 22, 1988.

The list of attendees is included as Enclosure 1.

The events discussed and the significant elements of these events are presented in Enclosure 2. presents two events suggested for long-term followup and c summiry of reactor scrams. One significant event was identified for input to NRC's performance indicator program.

& MYY Wayne D. Lanning, h ef Events Assessment Branch Division of Operational Events Assessment

Enclosures:

As stated cc w/ Encl.:

See Next Page I

1

ENCLOSURE 1 l

LIST OF ATTENDEES OPERATING REACTORS EVENTS BRIEFING (88-47)

November 29, 1988 NAME ORGANIZATION NAME ORGANIZATION t

T. Murley D:NRR U. Potapovs NRR/RVIB i

L. Zerr NRR/DOEA F. Rosa NRR/SELB J. Lazevnick NRR/SELB S. Juergens SECY M. Fields OSP R. Kendall NRR/DOEA 4-J. Kudrick NRR/SPLB J. Carter NRR/D0EA

]

R. Karsch NRR/DOEA R. Borchardt OEDO L. Norrholm OCM/KC H. Faulkner IP/GPA V. Benaroya AEOD/OSP M. Haughey NRR/DRPI-2 i

G. West, Jr.

NRR/HFAB C. Haughney NRR/DRIS M. Reardon NRR/DOEA B. Boger NRR/ADR-1 E. Rossi NRR/DOEA J. Roe NRR/DLPQ B. Grimes NRR/DRIS T. Gwynn OCM/LZ B. Siegel NRR/PD3-2 J. Dyer NRR/DRIS d

e i

1 l

1 i

(

I 1

r i

l l

I

?

i

)

9 ENCLOSURE 2 OPERATING REACTORS EVENTS BRIEFING 88-47 EVENTS ASSESSMENT BRANCH LOCATION:

12-B-11 WHITE FLINT TUESDAY, NOVEMBER 29, 1988, 11:00 A.M.

NINE MILE POINT 1 DEGRADED VOLTAGE IN 125 VOLTAGE DC SYSTEM DRESDEN UNIT 2 DAMAGE TO SAFETY-RELATED EQU:? MENT DUE TO ELEVATED DRYWELL TEMPERATURES

88 47 NINE MILE POINT 1 DEGRADED VOLTAGE IN 125 VOLTAGE DC SYSTEM NOVEMBER 18, 1988 PROBLEb THE 125 V0LTAGE DC (VDC) SYSTEMS DO NOT MEET THEIR DESIGN BASIS, E.G..

INSUFFICIENT VOLTAGE SUPPLIED TO POWER BOARDS TO ALLOW BREAKER OPERATION.

ChiLSE DESIGk DEFICIEliCY:

EXCESSIVE VOLTAGE DROP If1 CABLES SAFETY SIGlilFICANCE l

A LOSS OF NORMAL AC POWER COULD LEAD TO A COMPLETE LOSS OF DC POWER Afl0 THE SUBSECUENT LOSS OF EMERGEllCY AC POWER.

I DISCUSSION l

l 0

REACTOR SHUTDOWN SitiCE 12/57 AND CURRENTLY DEFUELED.

0 PROBLEM DISCOVERED DURING REDESIGN EFFORT.

o BATTERIES CONSIDEREL OPERABLE (PER TECHNICAL SPECIFICATIONS) WITH BATTERY TERMINAL VOLTAGE GREATER THAN 106 VDC.

o 114 VDC AT BATTERY TERhlNALS, REQUIRED TO MEET MANUFACTURER's MINIMUM OF 90 VDC AT BATTERY BOARD FOR BREAKER GPERATION.

o WITH 114 VDC, BATTERY CHARGERS MAY NOT SWITCH 10 EMERGENCY AC POWER, CAUSING BATTERY TO RUN DCWN AND TRIP EDG PROTECTIVE RELAYS, o

LICEllSEE DGES NOT PERFORM AN 18 MONTH SERVICE TEST.

l 0

LICENSEE L0ES liOT KNOW/HAVE DESIGN BASIS OR ORIGINAL TESTING DATA.

l o

NIAGARA M0 HAWK WAS SYSTEM DESIGNER.

i o

LICENSEE PLANNED TO DOCUMENT REVISED DESIGli BASIS FOR Ti1ElR RECORDS.

o LICENSEE WILL SUBMIT BASIS FOR NRR REVIEW, o

GENERIC LETTER (GL) 68-15 "ELECTRIC POWEk SYSTEMS - INADE00 ATE C0hTROL OVER DESIGN PROCESS" ENVELOPES THIS EVENT, LICENSEE HAS GL.

FOLLOWUE o

REGION T0 lilSPECT MODIFICATIONS, o

NRR TO REVIEW REVISED DESIGN AND BASIS, CONTACT:

J. CARTER

REFERENCE:

50.72 # 14039 AtlD MORllikG REPORT 11/22/88

88-47 i

DRESDEN UNIT 2 DAMAGE TO SAFETY-RELATED EQUIPMENT DUE_ID ElfVATED DRYWELL TEMPERATURES NOVEMBER 15, 1988 EB03LES t

SAFETY-RELATED EQUIF.EliT DEGRADED DUE TO HIGH TEMPERATURE IN UPPER REGION OF DRYWELL.

thDBE INADECUATE VEllTILAT10N.

SAEEIY SIGNIFICAufE DEGRADATION OF SAFETY-RELATED EO EQUIPMEllT AND ELECTRICAL WlRING.

DISCUSSJdB c

DURING THE REFUELING OUTAGE, LICENSEE DISCOVERED EVIDEflCE THAT THE PAINT IN ThE DRYWELL WAS EXPOSED TO ELEVATED TEMPERATURES.

o FURTHER IfiVESTIGATION REVEALED THE LIMITORQUE OPERATOR Off THE i

STEAM SUPPLY VALVES TO THE HPCI AND ISOLATION CONDEllSER HAD EVIDENCE OF EXCEEDIliG THE E0 DF. SIGN TEMPERATURE (DEGRADED GREASE AND DAMAGE TO OllE DEARING),

ALSO THERE WAS SOME CRACKING OF CABLE INSULATION.

o MAJOR DAMAGE RESTRICTED TO LEVEL 4 WITH MINOR DAMAGE TO CABLE SEAL TIGHT JACKETS Oli LEVEL 3.

l 0

ELEVATED TEMPERATURE RESULTED FROM FOUR VEllTILATION PORTS (2 SUPPLY AND 2 RETURil) EEING LEFi I!1 CLOSED POSIT 10!! SINCE APRIL 19. 1987.

l BOTH fiANWAY HATCHES WERE OPEll, i

0 MAINTEflANCE PROCEDURE HAD WORDS THAT SAID "HATCHS ARE OPEN".

PERSONNEL THOUGHT THAT HATCH REFERRED TO THE LARGE MANWAY COVERS AND DIDil'T CHECK THE OPEN!!'GS Oft VEf4TILAT10N DUCTS, o

HPCI AND ISOLATION CONDENSER VALVES DO NOT NEED TO OPEfi IN CASE OF A LOCA (THEY ARE h0RMALLY OPEN).

HOWEVER, THEY D0 tiEED TO OPERATE FOR CollTAINMENT ISOLATI0!i.

i C0 fit ACT:

T. GREENE

REFERENCE:

MORf!!NG REPORT 11/15/88 s

~

DRESDEN UtilT 2 88-47 o

SURVEILLAfiCE TESTIliG PERFORMED WEEKLY AfiD MONTHLY FOR VALVES, o

LICENSEE HAS FORMED A TASK FORCE, o

LICEf1SEE PLANS TO REPLACE ALL CABLES IN LEVEL 3 AND 4.

o PAINT AND GREASE HAS BEEli SENT OUT TO BE ANALYZED.

o MARK I CONTAINMEliTS HAVE HISTORY OF HIGH DRYWELL TEMPERATURES, TEMPORARY IllSTRUCTION (T/I) 2515/98, "INFORMATION OF HIGH TEMPERATURE If. SIDE C0fiTAINMEfiT/DRYhELL IN PWR Al4D BWR PLANTS" WAS ISSUED ON 06/30/88, RESP 0fiSES TO T/I ARE SCHEDULED FOR MID-DECEMBER.

FOLLOWUP o

LICEliSEE IS FREPARIf!G PROCEDURES TO CLARIFY THAT BOTH MANWAY AND VEliTILATION EUCTS ARE TO EE OPEN, o

LICEfiSEE PLAfiS TO IfiSTALL TEMPERATURE DETECTORS If1 UPPER REG 10ft, 0

DOEA IS WORKING WITH SPLB TO DETERMINE IF Afi INFORMATION NOTICE OR OTHER STRONGER ACTION IS NECESSARY,

DRESDEN UNIT 2 Unit 2 Drywell Top Floor

  1. v !.dY$

P p\\S 3

g an sde., m eV

, Ventiletten retum dwet atHetlen ey dwet O

6 g - A0V 33647 ADV 90646 f " *i

~

VESSEL HEAD VENT i MAN 1' it LIQUID CONTROL VALVES (TWO)

MAIN ENANCE STOP VALVE (50N-EQ)

(NON EQ) i Leedet down b

WOV M414 yg STEAM SUPPLY ".NE TO HPCI Ventitution r wn doet -

' Venehttlea esppy ggN

(

O

.s STEAM SUPPLY VALVE TO 88WHrey ISOLATION CONDENSER h8000.00s 1144 l

i l

SHIELD EQ.U1P M E NT

\\

PUEL PLUGS

!. STORAGE POOL POOL 3

me _ _

S'

._]

s L3 au sa l g head C

1

-1

- - - wa-

-=-

10 LOGICAL __

$HIELD mu t

a DRYWELL A

REACTOR VISSEL una t

.a zo

,,g_,

l

_.Lrvi,. t t

1

~

1

)

a f-

_1%tentp D

bj

  • ~

~

PRESSUT<E SUPPRESSION

'id f '

U.

POOL DRESDEN l' NIT 2

6 u.

EMCLOSURE 3 Np hs.

I 11/23/I3 i

RlMlliti LDulttu Fat:0 Htt y Ptte 344 es) plf Ills:Fltut Intflu FKLtd Allllutet tulMIT[I Ill11T110s lJGllt IPt:tti feAeFIA T2:

C *.tt!:4 r titut

t. tut lAtt l

H/ Hill CD 1

.f.

M 'le ttfa:eH Lt3 littl M As>;R ptlel 111:3/M luPVil TimlFINO TC st/tftl. f(f attitPfl

//

l C4:1 W4tl. Ir.tittlatt 14 CA.!! CF filik81 AP! IllJEltU 10 ( AGAtt 74 WITT IFt!:All>l

[

H: Littelt! LA3 W It'Mithi. Il FJBt(t F3 ALL Ll:teltti B40 Mf M4 $181tM Mill! Ail t

Etttt C A:!th (t:t3?

le Wtit-t!L4tti Cl*0stifl II !!#164 l

tev:sttMlail. (Mau!C fila ITAf 10 IC@t litK9 tufte 2 t#t811R1 illiflH) Ana C :t Witt i

i i 2 (etP3tt it/Hin)).

Hl09/H ID 2

.f.

M0ttu 8tta:(a Axt lict on as:st spuel 11/21/881r411 feassrtatti il asa!!Cl. f41 att!!'il

//

C43 4b13. It1111517114 CA31 C# FAILWI Att t!Ettf[1 il (WG4f t f( WI1119t!;At! Del Ae: Litteill LC 7 MP3fini. Il Flat (t F04 ALL Littugtl M Mt M4 llP tM M*tt!A.1 Gluttit A:113E htt: tit la WIff.Aftetti (WW.uti It I:n:tna ItVll3h(stl. (Matt! lllJE = $f'J:113 !CCE llaK8 (MVM 2 (9tt38718/11/H) amt C;3 Wlil i I 2 (*tPWT 99/H/H)).

M/p/II 488:1

.F.

>A: stint (1c1:3 as) WiknH W fitsinAt R ll, ant /ty!I 73 Mitwist 17 fall 15 Wttf ut:Av!!

//

CICI: I!!! 5411:n Lla3 a:51 Inl. int!Du. FlO lila:FICH1, ]F 1118 14 tittat 7 T4 C#A:lltl Iwit il f( tutti Metalt 10 fugt acct Wytt, Aq IF M Ixt >tal ntet Ac lAettel Iflits VAatli 818 !W:#MilOE 5:11:1 !!

3.e:It ;C:ta BJtlel SHvt:11 11 Anf twy:tRtut 8 tac!tti. I?.lf fl ICQ( Milli (!!415) AR:

Ef1:e Puiti? list.!! ant A:*;fl>A;lila:F;; sat n:llst;u (WIP:tf thF Ana?!:e I!!d Vit::A Mh;d.

Hi2G/ H).

C9 /*0 8 1:1!=l's

.F.

fult; B::: 44 vtst Wytl atti a:1 (Wit (s' vtt:t ItaCv yttL FILos UP gu fx]l Pcl;tt 13 puiti:3

/I I

rAlf!!) 40 C1 tm Litteltt s Ex:'ntet Mftst;nt IF 11 Il li.Fitf tils!Fltat, tr 17 Il KAL:FltAtt:s Lili, n.f atti f(f c1 tg in!l 6 tut:L fl Ad TAlltf 80CI WWtl, A411F M L!!it tal 74 vtect neA#t fdf f41 Scal N InF> eat!*n Ef :t il MW!sti, lint 10 It!Ntst FA!F:t:$ g!LL 4 PAtt 21 ct!Figatt:q ICLtt wail (!!413) Aa: t;l;nt:u (etP:sf M lit,tl* !! T4 f t:tta !! cat f3 f4 Matll l9129/11).

tkint 13415' MllilJ ly; spat:3 4t1:1.

10/ l/11 Iltlit tut ** 2 of.

IF;att Ittalett KOct I?ct Ct Ae>* ;l IAntti 11/23/11 ItNT: Tem!FttMI ft st/tutt, f(f stAltati i/

DE:t WVit tr.tttilatt f4 C4J! f/ FA:ttt! Att stLtt'[I 73 (MLAtt f4 $4FITT 19i:;4:l*t!

80 LA*J 07 LI:ttttt sis;st;nt, tl F;st(t p;s 4;t tt:tittti g MI u.t fle:taa M*ttla.

Itttil: A:ft:esti:tli te laFitf sttain CW38tCl II 11444 i

tynt:enett ($tt[3:t Illa. StJIt 13 ICV:t 518F.3 Cuf:t ! [gtt:41 Illif/H) nel txt galts

! I I (#tp tf H/ Hill)).

i i

I I

l t

l l

~

. Page No.-

1 11/29/83 PERFORMANCE INDICATORS SI6NIFICANT EVENTS

  • PLCT NAME EVENT EVENTDESCA!Pil0N OTR S!6N!FICANCE DATE MC6UIRE 1 11/18/88 CROS! CONNECTS FRCM DIESEL STARTING AIR TO INSTRUMENT AIR 0POTENilALFORORACTUALDE6RADATION TANKS PA0 VIDE BACKUP A!R. HOWEVER, THIS COULD RESULT IN OF SAFEif-RELATED EQUIPRENT.

AN INADE00 ATE SUPPLY OF STARTING AIR DUR!h6 A BLAC100T.

MC6UIRE 2

!!/18/98 CROSS CONNECTS FROM O!ESEL STARi!NG AIR TO INSTRUMENT AIR 0 POTENTIAL FOR OR ACTUAL DEGRADAi!ON TANKS PROVIDE BACKUP A!R. NCWEVER, THIS COULD RESUt,T IN OF SAFETY RELATED EQUIPMENT.

AN INAIEDUATE SUPPLY OF STARTING AIR DURING A BLACK 0UT.

1 I

k l

I I

i i

i 2

J i

I

_.. _ __ _~ _,-,,

6 REACTOR SCRAR

SUMMARY

NEEKEmelN611/27/M

!. PLANT SPEttFl DATA HIE S!it UNIT PONER 5!ENAL CAUSE COMPLI-YTD YTD YTD Call 0NS A80VE MLON TOTAL L

!$1 151 I

11/21/93 I!6 RCCK PO!NT 1

93 A EDU!PMENT NO 2

2 4

11/22/84 'ht!AN PJINT 2 100 A EDUlFMENT N0 3

1 4

11/23/88 CATANIA 2

48 M PERSONNEL NO I

1 9

11/23/98 COOK 1

90 A EOUIPMENT N0 3

0 3

11/26/06 thDIAN POINT 2 100 A EOUIPMENT N0 4

1 5

r 11/27/88 DRESHN 3

17 A E90!PMENT NO 1

0 1

i f

l I

n i

I i

)

i i

[

4 I

r I

1 I

i t

4 I

,.. ~

  • NOTES 1.

PLANT SPECIFIC DATA BASED ON INITIAL PEVIEW 0F 50.72 REPORTS FOR THE WEEK OF INTEREST.

PERIOD IS MIDNIGHT SUNDAY THROUGH MIDNIGHT SUNDAY.

SCRAMS ARE DEFINED AS REACTOR PROTECTIVE ACTUATIONS WHICH RESULT IN ROD MOTION, AND EXCLUDE PLANNED TESTS OR SCRAMS AS PART OF PLANNED SHUTDOWN IN ACCORDANCE WITH A PLANT PROCEDURE.

THERE ARE 109 REACTORS HOLDING AN OPERATING LICENSE.

2.

COMPLICATIONS: RECOVERY COMPLICATED BY EQUIPMENT FAILURES OR PERSONNEL ERRORS UNRELATED TO CAUSE OF SCRAM.

3.

r RSONNEL RELATED PROBLEMS INCLUDE HUMAN ERROR, PROCEDURAL DEFICIENCIES, AND MANUAL STEAM GENERATOR LEVEL CONTROL PROBLE!!S.

4 "0THER" INCLUDES AUTOMATIC SCRAMS ATTRIBUTED TO ENVIRONMENTAL CAUSES (LIGHTNING), SYSTEM DESIGN, OR UNKNOWN CAUSE.