L.

June 22,1988 r

Docket No. :

50-029 Mr. George Paponic, Jr.

Senior Project Engineer-Licensing Yankee Atomic Electric Company 1671 Worcester Road Framingh6m, Massachusetts 01701

SUBJECT:

STEAM BINDING 0F AUXILIARY FEEDWATER PUMPS - YANKEE NUCLEAR POWER STATION

Dear Mr. Papanic:

On February 17, 1988, Generic Letter 88-03 was issued to Yankee Atomic Electric Company and requested all licensees of operating PWRs and holder; of construc-tion permits for PWRs to confiru that appropriate procedures are in place, and will be mainteined, to minimize the eccurrence of steam binding of the auxiliery feedwoter (AFW) pumps. The procedures require monitoring fluid conditions within the AFW system each shif t during times when the system is required to be operable, and recognizing steam binding and restoring the AFW svstem to operable status should steam binding occur.

Your response, dated May 25, 1988 for the Yankee Nuclear Power Stetion, confirmed that you have in place, and will maintain, the necessary procedures.

Thus, your response to Generic Letter 88-03 is satisfactory and no further action is necessary.

Sincerely, Origilial Signed by:

Morton B. Foirtile, Project Manager Project Directorate I/III Division Reactor Projects I/II cc: See next page DISTRIBUTION: 08cketIFjle, NRO & Local Pdrs, SVarga, BBoger, MRushbrook, 0GC, EJor~ dan, BGrimes, ACRS(10), RWessman, MFairtile 8806300300 000602 PDR ADOCK 050000D9 P

PDR

PDT_3 D7PDT23 i:

DTE~iPDI-3 f_____:MFairtile.....,8(.S @:

____.34V..:_________..:........___.:.._________:.__________

NAME :MR s Drook

RWessman DATE :06 88
06/W88
06 /-g/88 0FFICIAL RECORD COPY

t lb l

T o

t l

Mr. George Papanic, Jr.

l Yankee Atomic Electric Company Yankee Nuclear Power Station l

l l

cc:

Mr. James E. Tribble, President Mr. George Papanic, Jr.

Yankee Atomic Electric Company Senior Project Engineer-Licensing 1671 Worcester Road Yankee Atomic Electric Company Framingham, Massachusetts 01701 1671 Worcester Road Framingham, Massachusetts 01701 Thomas Dignan, Esquire Ropes and Gray 225 Franklin Street Boston, Massachusetts 02110 1

Mr. N. N. St. Laurent Plant Superintendent Yankee Atomic Electric Company Star Poute Rowe, Massachusetts 01367 l

l Chairman Board of Selectmen Town of Rowe Rowe, Massachusetts 01367 Pesident Inspector Yankee Nuclear Power Station c/o U.S. NRC Post Office Box 28 Monroe Bridge, Massachusetts 01350 Regional Administrator, Region !

U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406 Robert M. Hallisey, Director Radiation Control Program Massachusetts Department of Public Health 150 Tremont Street, 7th Floor Boston, Massachusetts 02111 I

l l

l I