CVlWS

,,,o 3.6.17 L

3.6 CONTAINMENT SYSTEMS 3.6.17 Containment Valve injection Water System (CVlWS) l LCO 3.6.17 Two CVlWS trains shall be OPERABLE.

APPLICABILITY:

MODES 1,2,3, and 4.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME l

A.

One CVlWS train A.1 Restore CVlWS train to 7 days inoperable.

OPERABLE status.

B.

Required Action and B.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time not met.

AND B.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> -

l SURVEILLANCE REQUIREMENTS 4

SURVEILLANCE FREQUENCY SR 3.6.17.1 Verify system surge tanks pressure is 2 36.4 psig.

31 days

/

SR 3.6.17.2 Verify valve injection flow rate is < 1.29 gpm (Unit 1) 18 months

< 1.21 gpm (Unit 2) for Train A and < 1.16 gpm for Train B with a surge tank pressure z 36.4 psig.

SR 3.6.17.3 Verify each automatic valve actuates to its correct 18 months position on an actual or simulated actuation signal.

9811270079 981120 PDR ADOCK 05000413 P

PDR Catawba Units 1 and 2 3.6.17-1 Amendment Nos.173/165

., -