T 69 y
i USEC
, A Global Enwgy Company l
November 20,1998 GDP 98-0251 Dr. Carl J. Paperiello Director, Office of Nuclear Material Safety and Safeguards l
Attention: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Portsmouth Gaseous Diffusion Plant (PORTS)
Docket No. 70-7002 Certificate Amendment Request - Update the Application Safety Analysis Report - Proposed Changes
Dear Dr. Paperiello:
By letter dated October 31,1997 (Reference 1), USEC submitted a certificate amendment request (CAR) containing the Safety Analysis Report Update (SARUP) required by Issue 2 of DOE /ORO-2027," Plan for Achieving Compliance with NRC Regulations at the Portsmouth Gaseous DitTusion Plant" (the Compliance Plan), for NRC review and approval. By letters dated April 30,1998 (Reference 2) and October 19,1998 (Reference 3), USEC submitted proposed changes to the SARUP certificate amendment request. This letter provides additional changes to the SARUP certificate amendment request.
USEC's October 31,1997 letter contained the following commitment (Enclosure 1, Table 1, item 5):
The SARUP re-classifies the X-330 rail cars for tails cylinders as Q components. A seismic analysis will be performed to assess the capacity of the rail cars to withstand j
the evaluation basis earthquake event. The results of the analysis, including the identification of any necessary modifications and the associated implementation schedule, will be submitted to the NRC by August 3,1998.
4 In accordance with this commitment, a seismic analysis of the rail cars was completed and a summary of the results was submitted to the NRC on July 31,1998 (Reference 4). In Reference 4, USEC l
committed to revise the boundary description in SARUP Table 3.8-1 for the rail cars and to submit the revision to the NRC by November 20,1998.
9811270072 991120 7 PDR ADOCK 0700 0 C
6903 Rockledge Drive, Bethesda, MD 20817-1818 Telephone 301-564-3200 Fax 301-564-3201 http://www.usec.com O$ces in Livermore, CA Paducah, KY Portsmouth, OH Washington, DC 2 3 RB 4
~ Dr. Carl J. Paperiello November 20,1998
. GDP 98-0251, Page 2 l
In accordance with this commitment, SARUP Table 3.8-1 has been revised to clarify the "Q" y
l boundary for the rail cars. SARUP Section 3.8.6.3.3 has also been revised to reflect the conclusions l
from the seismic study. Enclosure 2 to this letter provides a detailed description of the proposed changes to SARUP. Revised SARUP pages and insertion / removal instructions are provided in. Revisions are noted by a revision bar in the left-hand page margin. The conclusions stated in Enclosure 2 to Reference 1, that the proposed changes associated with the CAR are significant, are not affected by this revision and thus no significance determination is provided..
Any questions regarding this matter should be directed to Steve Routh at (301) 564-3251. There are no new commitments contained in this submittal.
Sincerely,
/1
- s. a.
I Steven A. Toelle Nuclear Regulatory Assurance and Policy Manager
References:
- 1. Letter from James H. Miller (USEC) to Dr. Carl J. Paperiello (NRC), Cenificate Amendment Request - Update the Application Safety Analysis Report, USEC Letter GDP 97-0189, October 31,1997.
- 2. ; Letter from James.H. Miller (USEC) to Dr. Carl J. Paperiello (NRC), Certificate l
Amendment Request - Update the Application Safety Analysis Report - Proposed Changes, USEC Letter GDP 98-0096, April 30,1998.
i
- 3. Letter from Steven A. Toelle (USEC) to Dr. Carl J. Paperiello (NRC), Certificate l
Amendment Request - Update the Application Safety Analysis Report - Proposed
~
L Changes, USEC Letter GDP 98-0212, October 19,1998.
I
- 4. Letter from Steven A. Toelle (USEC) to Dr. Malcolm R. Knapp (NRC),
l Certificate Amendment Request - Update the Application Safety Analysis Report i
- Submittal of Rail Car Seismic Analysis Results, USEC Letter GDP 98-0157, July 31,1998.
L i
)
F c
--4
. ~,,
,,,,,-a
,.,n,.
i Dr. Carl J. Paperiello November 20,1998 l
. GDP 98-0251, Page 3
Enclosures:
- 1. - Affidavit
- 2. United States Enrichment Corporation (USEC), Proposed Changes, Certificate Amendment Request, Update the Application Safety Analysis Report, Detailed l
Description of Change i
j'
- 3. Proposed Changes, Certificate Amendment Request, Safety Analysis Report l
Update, Insertion / Removal Instructions, October 19,1998 cc: Mr. Robert C. Pierson, NRC NRC RegionIII OHice NRC Resident Inspector - PORTS
. NRC Resident Inspector - PGDP Mr. Randall M. DeVault, DOE i
1 i
i t-l a
t.
f l.
t
~
- = _.
~.
l l-OATH AND AFFIRMATION I, Steven A. Toelle, swear and affirm that I am the Nuclear Regulatory Assurance and Policy c
Manager of the United States Enrichment Corporation (USEC), that I am authorized by USEC to l
. sign and file with the Nuclear Regulatory Commission these proposed changes to the Safety Analysis Report Update for the Portsmouth Gaseous Diffusion Plant, as described in Letter GDP 98-0251, that I am familiar with the contents thereof, and that the statements made and matters set forth therein are 1
true and correct to the best of my knowledge, information, and belief.
l
/l 1
- 5. A.
I Steven A. Toelle i
i On this 20th day ofNovember 1998, the individual signing above personally appeared before me, is known by me to be the person whose name is subscribed to within the instrument, and acknowledged that he executed the same for the purposes therein contained.
L In witness hereofI hereunto set my hand and official seal.
00AM i/Al} }J-~
VLabrie M. Knisley, Notary Public
[/
~~
State of Maryland, Montgomery County l
My commission expires March 1,2002 i
i P
Y
.h..
1 L
GDP 98-0251 Page 1 of 2 United States Enrichment Corporation (USEC)
Proposed Changes Certificate Amendment Request Update the Application Safety Analysis Report Detailed Description of Change 1.0 f.urRQ1t f
The purpose of this submittal is to provide revised pages to the Safety Analysis Report Update (SARUP) previously transmitted in USEC letters GDP 97-0189, dated October 31,1997 (Reference 1); GDP 98-0096, dated April 30,1998 (Reference 2); and GDP 98-0212, dated October 19,1998 (Reference 3) for NRC review and approval.
2.0 Description of Submittal The following changes are included in this submittal which modify the latest version of the SAR Update certificate amendment request. The revised pages are included in Enclosure 3.
A.
The Revision Log has been updated to reflect the changes included in this revision.
B.
The List of Effective Pages has been updated to reflect the changes included in this revision.
1 C.
SARUP Section 3.8.6.3.3 has been revised to reflect the conclusions from the rail car seismic study.
I D.
SARUP Table 3.8-1 has been revised to reflect the new "Q" boundaries for the rail cars. The boundary includes the cylinder saddle, supports, and associated attachments to the rail car frame; the rail car frame; and the rail car truck assembly.
3.0 Basis for the Revision The SARUP re-classifies the X-330 rail cars for tails cylinders as Q components. The L
previously submitted SARUP "Q" boundary description for the rail cars provided no specificity pending completion of a seismic analysis of the rail cars. The changes to the "Q" boundary definition l
for the rail cars contained herein (SARUP Table 3.8-1) are based on the results of the completed seismic analysis (described in Reference 4) and include those components that are within the load path for a cylinder being carried on a rail car.
I l
l GDP 98-0251 Page 2 of 2 References 1.
Letter from James H. Miller (USEC) to Dr. Carl J. Paperiello (NRC), Certificate Amendment Request - Update the Application Safety Analysis Report, USEC Letter GDP 97-0189, October 31,1997.
l 2.
Letter from James H. Miller (USEC) to Dr. Carl J. Paperiello (NRC), Cenificate Amendment l-Request - Update the Application Safety Analysis Report - Proposed Changes, USEC Letter GDP 98-0096, April 30,1998.
3.
Letter from Steven A. Toelle (USEC) to Dr. Carl J. Paperiello (NRC), Certificate Amendment Request - Update the Application Safety Analysis Report - Proposed Changes, USEC Letter GDP 98-0212, October 19,1998.
4.
Letter from Steven A. Toelle (USEC) to Dr. Malcolm R. Knapp (NRC), Certificate
- Amendment Request - Update the Application Safety Analysis Repon - Submittal of Rail Car t
Seismic Analysis Results, USEC Letter GDP 98-0157, July 31,1998.
i l
l I
1 i
l GDP 98-0251
~
Page 1 of 6 7
t 4
7;7 qv 35FETYANAL 51S'REPORTUPDATE) l CERTIFICATE AMENDMENT REQU.ESTJ.
- NOVEMBER 20 ;1998 REVISION /
's 1
Remove Pages Insert Pages SARUP Revision Log SARUP Revision Log Ii i
SARUP List of Effective Pages SARUP List of Effective Pages SARUP-1, SARUP-3 SARUP-1, SARUP-3 SARUP Section 3.8 SARUP Section 3.8 l
3.8-51, Table 3.8-1 sheet 4 3.8-51, Table 3.8-1 sheet 4 1
l s
.. -. ~. -
- - _ - - - - ~. - - - - -..
. November 20,1998 United States Enrichment Corporation Portsmouth Gaseous Diffusion Plant Safety Analysis Report Update REVISION LOG Dale Descrintion 8/18/97 Initial Issue. Included: changes to SAR Chapter 2 (changed pages only); new SARUP Sections 4.1,4.2.1 through 4.2.5,4.3.1,4.4.
10/31/97 Submittal of complete SARUP (including 8/18/97 sections unchanged), with the exception of changes to Application SAR Chapter 3. Included: changes to SAR Chapters 1 and 2 and Sections 5.2,5.4, and 5.6 (changed page.s only); complete replacement of Section 3.8, Chapter 4, and the TSRs; new Section 5.2, Appendix A.
4/30/98 Submittal to remove the fixed fire suppression sprinkler systems within the I
X-324-A and X-344-A facilities and the sanitary and fire water system (SFWS),
including its distribution and elevated storage tank as safety (AQ) systems.
Sections revised include: Section 3.8.7.2, Table 3.8-2, Table 4.2-5, Table 4.2-11, I
Section 4.3.2.2.16, TSR Table of Contents, TSR 2.2.3.3, TSR 2.4.3.1.b, TSR O
2.4.3.2.a, and TSR 2.4.3.2.b. A SARUP List of Effective Pages is added.
10/19/98 Submittal to incorporate modifications to install additional handswitches at building exits for remote manual isolation of the remote feed isolation system in Building X-342-A; add a clarification to the Technical Safety Requirements, Section 2.1.3.6, Basis regarding draining raw cooling water (RCW) from process gas coolant condensers as a method to preclude introduction of a moderator (RCW) to the process system; add a reference to carbon dioxide ice blasting as an additional controlled means of field removal of uranium contamination from process equipment and facilities; make corrections to AQ-NCS boundary
)
definidons regarding the high pressure venting system; revises the highest fire system sprinkler flow demand requirements; adds commitments to certain codes and standards for process building cranes; corrects a standard edition date error; and clarifies the commitment to codes and standards for liquid UF. cylinder handling cranes.
l 11/20/98 Submittal to inciude a description of the Q boundary for rail cars. Revised Section l
3.8.6.3.3 and Table 3.8-1.
i
l SARUP-PORTS November 20,1993 l
l LIST OF EFFECTIVE PAGES REVISION LOG CHAPTER 2 (Continued)
Eagg RAC/ Revision /Date Eagg RAC/ Revision i
i November 20,1998 2.3-7 RAC 97-X0248 (RO) 2.3-8 RAC 97-X0248 (RO)
CIIAPTER 1, APPENDIX A 2.3-9 RAC 97-X0248 (RO) 2.3-10 RAC 97-X0248 (RO)
Eage RAC/ Revision 2.3-11 RAC 97-X0248 (RO)
A-1 RAC 97-X0506 (RO) 2.3-12 RAC 97-X0248 (RO)
A-2 RAC 97-X0506 (RO) 2.3-13 RAC 97-X0248 (RO)
A-3 RAC 97-X0506 (RO) 2.3-14 RAC 97-X0248 (RO)
A-4 RAC 97-X0506 (RO) 2.3-15 RAC 97-X0248 (RO)
RAC 98-X0130 (RO) 2.3-16 RAC 97-X0248 (RO)
A-5 RAC 97-X0506 (RO) 2.3-17 RAC 97-X0248 (RO)
RAC 98-X0130 (RO) 2.3-18 RAC 97-X0248 (RO)
A-6 RAC 97-X0506 (RO) 2.3-19 RAC 97-X0248 (RO)
A-7 RAC 97-X0506 (RO) 2.3-20 RAC 97-X0248 (RO) l A-8 RAC 97-X0506 (RO) 2.3 21 RAC 97-X0248 (RO)
A-9 RAC 97-X0506 (RO) 2.4-2 RAC 97-X0248 (RO)
L A-10 RAC 97-X0506 (RO) 2.4-6 RAC 97-X0248 (RO) l
.b
RAC 97-X0506 (RO) 2.4-7 RAC 97-X0248 (RO)
A A-12 RAC 97-X0506 (RO) 2.4-8 RAC 97-X0248 (RO)
U 2.4-9 RAC 97-X0248 (RO)
CllAPTER 2, CONTENTS 2.4-11 RAC 97-X0248 (RO) 2.6-1 RAC 97-X0248 (RO) i Eage RAC/ Revision 2.6-2 RAC 97-X0248 (RO) ii RAC 97-X0248 (RO) 2.6-3 RAC 97-X0248 (RO) iii RAC 97-X0248 (RO) 2.6-4 RAC 97-X0248 (RO) iv RAC 97-X0248 (RO) 2.6-5 RAC 97-X0248 (RO) y RAC 97-X0248 (RO) 2.6-6 RAC 97-X0248 (RO) 2.6-7 RAC 97-X0248 (RO)
CHAPTER 2 2.6-8 RAC 97-X0248 (RO) l 2.6-9 RAC 97-X0248 (RO)
Eage RAC/ Revision 2.6-10 RAC 97-X0248 (RO) 2.1-6 RAC 97-X0248 (RO) 2.6-11 RAC 97-X0248 (RO) 2.3-1 RAC 97-X0248 (RO) 2.6-12 RAC 97-X0248 (RO) 2.3-2 RAC 97-X0248 (RO) 2.6-13 RAC 97-X0248 (RO) 2.3-3 RAC 97-X0248 (RO) 2.7-1 RA :. 97-X0248 (RO) l 2.3-4 RAC 97-X0248 (RO) 2.7-2 RAC 97-X0248 (RO) l 2.3-5 RAC 97-X0248 (RO) i 2.3-6 RAC 97-X0248 (RO) 4 h
SARUP-1
- - - - -.. ~. - - - -. - -. -
_ ~ -..
SARUP-PORTS November 20,1998 LIST OF EFFECTIVE PAGES CHAPTER 3.8 (Continued)
CHAPTER 3.8 (Continued)
Eagg RAC/RevisiQD Eage RAC/ Revision 5
3.8-45 RAC 97-X0506 (RO) 3.8-77 RAC 97-X0506 (RO) 3.8-46 RAC 97-X0506 (RO) 3.8-78 RAC 97-X0506 (RO) 3.8-47 RAC 97 X0506 (RO) 3.8-79 RAC 97-X0506 (RO) 3.8-48 RAC 97-X0506 (RO) 3.8-80 RAC 97-X0506 (RO) 3.8-49 RAC 97-X0506 (RO) 3.8-81 RAC 97-X0506 (RO)
{
RAC 98-X0130 (RO) 3.8-82 RAC 97-X0506 (RO) 3.8-50 RAC 97-X0506 (RO)
RAC 98-X0130 (RO)
CHAPTER 3.8, TABLES 3.8-51 RAC 97-X0506 (RO)
RAC 98-X0152 (RO)
East RAC/ Revision 3.8~52 RAC 97-X0506 (RO)
T3.8-1, Sht.1 RAC 97-X0506 (RO)
)
3.8-53 RAC 97-X0506 (RO)
T3.8-1, Sht. 2 RAC 97-X0506 (RO) 3.8-54 RAC 97-X0506 (RO)
T3.8-1, Sht. 3 RAC 97-X0506 (RO)
RAC 98-X0044 (RO)
T3.8-1, Sht. 4 RAC 97-X0506 (RO) i 3.8-55 RAC 97-X0506 (RO)
RAC 98-X0152 (RO)
RAC 98-X0044 (RO)
T3.8-1, Sht. 5 RAC 97-X0506 (RO)
RAC 98-X0129 (RO)
T3.8-2, Sht.1 RAC 97-X0506 (RO) 3.8-56 RAC 97-X0506 (RO)
T3.8-2, Sht. 2 RAC 97-X0506 (RO) l C RAC 98-X0044 (RO)
T3.8-2, Sht. 3 RAC 97-X0506 (RO) 3.8-57 RAC 97-X0506 (RO)
T3.8-2, Sht. 4 RAC 97-X0506 (RO)
'3.8-58 RAC 97-X0506 (RO)
T3.8-2, Sht. 5 RAC 97-X0506 (RO) 3.8-59 RAC 97-X0506 (RO)
T3.8-2, Sht. 6 RAC 97-X0506 (RO) l 3.8-60 RAC 97-X0506 (RO)
T3.8-2, Sht. 7 RAC 97-X0506 (RO) 3.8-61 RAC 97-X0506 (RO)
T3.8-2, Sht. 8 RAC 97-X0506 (RO) 3.8-62 RAC 97-X0506 (RO)
T3.8-2, Sht. 9 RAC 97-X0506 (RO) 3.8-63_
RAC 97-X0506 (RO)
RAC 98-X0044 (RO) 3.8-64 RAC 97-X0506 (RO)
T3.8-2, Sht.10 RAC 97-X0506 (RO) 3.8-65 RAC 97-X0506 (RO)
T3.8-2, Sht,11 RAC 97-X0506 (RO)
RAC 98-X0130 (RO)
T3.8-2, Sht.12 RAC 97-X0506 (RO) 3.8-66 RAC 97-X0506 (RO)
T3.8-2, Sht.13 RAC 97-X0506 (RO) 3.8-67 RAC 97-X0506 (RO)
T3.8-2, Sht.14 RAC 97-X0506 (RO) l 3.8-68 RAC 97-X0506 (RO)
T3.8-2, Sht.15 RAC 97-X0506 (RO) 3.8-69 RAC 97-X0506 (RO)
T3.8-3, Sht.1 RAC 97-X0506 (RO) i RAC 97-X0561 (RO)
RAC 97-X0561 (RO) i-3.8-70 RAC 97-X0506 (RO)
T3.8-3, Sht. 2 RAC 97-X0506 (RO) i 3.8-71 RAC 97-X0506 (RO)
T3.8-3, Sht. 3 RAC 97-X0506 (RO) 3.8-72 RAC 97-X0506 (RO)
T3.8-3, Sht. 4 RAC 97-X0506 (RO) 3.8-73 RAC 97-X0506 (RO)
T3.8-4 RAC 97-X0506 (RO) 3.8-74 RAC 97-X0506 (RO)
T3.8-5 RAC 97-X0506 (RO) 3.8-75 RAC 97-X0506 (RO)
T3.8-6 RAC 97-X0506 (RO) 3.8-76 RAC 97-X0506 (RO)
O SARUP-3
SAR-PORTS PROPOSED November 20,1998 f)
RAC,97-X0506 (RO), RAC 98-X0152 (RO) v 3.8.6.3 Liquid UF Cylinder Handling Equipment 3.8.6.3.1 Safety Function i
The liquid UF, cylinder handling equipment shall not fail in a manner to cause UF primary system 6
failure. Theliquid UF cylinder handling equipment provides for the safe movement ofliquid UF, cylinders.
3.8.6.3.2 Functional Reaulrements The liquid UF cylinder handling equipment shall be designed in accordance with the following 6
functional requirements to ensure the capability to accomplish the required safety function:
The cylinder handling equipment shall be designed to withstand the evaluation basis earthquake and not fail in a manner such that the cylinder will be dropped and failure will occur.
The cylinder handling equipment shall be designed to withstand the evaluation basis wind loading and i
not fail in a manner such that the cylinder will be dropped and failure will occur.
3.8.6.3.3 System Evaluation
'Ihis system includes scale carts and railcars used for moving cylinders that contain liquid UF.. The required safety ftmetion associated with the liquid UF. cylinder handling equipment is that it must not fail in a manner that will result in the failure of a cylinder during normal operadon, upset events that do not address (g) failure of the equipment, or natural phenomena events. By protecting the integrity of the cylinders, this system provides protection for on-site perwnnel and the off-site public from releases that could result if the system failed. Administrative controls require that (1) the UF, cylinder handling equipment be approved for the applicable use before handling UF, cylinders, (2) filled cylinders must complete a prescribed cooldown period l before they are moved with handling equipment not approved for use with liquid UF. cylinders, (3) cylinder l handling cranes be inspected daily (prior to first use) for obvious defects, and (4) a railcar carrying liquid l cylinders shall not be loaded with greater than three type 480 cylinders filled with liquid UF.
6 The scale carts and railcars were evaluated to assess their ability to withstand natural phenomena events. The analyses indicated that the scale carts will not % ave any structural damage, will remain in place, l ar.d will not release their loads during an evaluation l' asis earthquake. The scale carts and railcars are insensitive to evaluation basis wind loadings. Floods do not reach the elevation of the facility and, therefore, do not threaten equipment capabili+y.
Pud on the design requirements and administrative controls, the safety fueruon for the UF. cylinder handling cgaipment can be accomplished.
f*
d 3.8 5i
7 d(.
k.)
( _,./
9 CC nN cm 9O Table 3.8-l. Boundary Definition for Q Structures, Systems, and Components (continued)
XN 8d o
System Facility Boundary Definition Suppon Systems 1
N Liquid UF6 Cylinder X-326 1.
Cylinders with the capacity of holding more than No suppen systems are required.
o (Section 3.8.6.1)
X-330 500 lb of UP.
X-333 2.
Cylinder valve h
X-342A 3.
Cylinder plug n
X-343 g
X-344A Cylinder valve protector is classified as AQ. See Table g
3.8-2.
o Liquid UF, Cylinder X-326 1.
Iloist brakes The crane braking system is fail safe d
llandling Cranes (Section X-330 2.
Poist motor upon loss of the electrical suppon g
3.8.6.2)
X-333 3.
Upper movement paddle limit switch system o
m X-342A 4.
Wire rope and hook X-343 5.
Hoist shaft / coupling X-344A 6.
Pendant control / radio control p
7.
Passive mechanical and structural aspects of the O
crane and suppons as indicated on plant boundary o
drawings y
8.
Geared up/down limit switch o
Liquid UF, Cylinder Lifting X-326 1.
Lifting fixture assembly No support synems are required.
Fixtures (Section 3.8.6.2)
X-330 2.
Wire rope legs (belly bands for X-344A cranes)
X-333 X-342A X-343 X-344A Liquid UF, Cylinder X-326 1.
Scale carts (inchiding cradles)
No suppon systems required llandling Equipment (Section X-330 2.
Railcars (X-330 Tails operations only) 3.8.6.3)
X-333
- Cylinder saddles and suppons, including X-344A attachments to rail car frame
- Rail car frame 7
- Rail car truck assembly g
n B?
4 8
88 m