Y (s f D f?

7590-01 UNITED STATES tiUCLEAR REGULATORY COMMISSION l

CAROLINA POWER & LIGHT COMPANY DOCKET NOS. 50-261 NOTICE OF ISSUANCE O_F AllEh0 MENT TO FACILITY OPERAT!hG LICENSE The U.S. Nuclear Regulatory Ccomission (Commission) has issued Amendment No.119 to Facility Operding License No. DPR-23 issued to Carolina Power

& Light Company, which revised the Technical Specifications for operation of the H. B. Robinson Steasi Electric Plant, Unit No. 2, located in Darlington County, South Carolina. The amendment is effective as of the date of issuance.

The amendment modifies the Technical Specifications to remove the restriction limiting operating power to 1380 MWt when only two safety injection pumps are operable, to permit operation at a steady state reactor core power level not to exceed 2300 MWt with two safety injection pumps operating, and to restore power peaking factor (Fq) to 2.32 from the current value of 2.26 when twc safety injection pumps are operable.

The application for the amendment complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Cosmission's rules and regulations. The Commissicn has made appropriate findings as required by the Act and the Ccomission's rules and regulations in 10 CFR Chapter I, which are set forth in the license amendment.

Notice of Consideratter. of Issuance of Amendment and Opportunity for Hearing in connection with this action was published in the FEDERAL REGISTER on May 19, 1988 (53 FR 17996).

No request for a hearing or petition for leave to intervene was filed following tnis notice.

8806290460 000620 PDR ADOCK 05000261 P

PDR

. The Comission has prepared an Environmental Assessment related to the action and has determined not to prepare an environmental impact statement.

Based upon the environmental assessment, the Comission has concluded that the issuance of this arendment will not have a significant effect on the quality of the human environment.

For further details with respect to the action see (1) the application for amendment dated May 7,1988, and supplemented May 16 and 20,1988, (2) Amendment No.119 to License No. DPR-23, and (3) the Comission's related Safety Evaluation and Environmental Assessment. The May 16 and 20, 1988 submittals provided supplemental information and corrections which did not alter the action as noted in the FEDERAL REGISTER on May 19. 1988. These items are available for public inspection at the Comission's Public Document Room, 1717 H Street NW, Washington, D. C.

20555 and at the Hartsville Memorial Library, Home and Fifth Avenues, Hartsville, South Carolina 19535. A copy of items (2) and (3) may be obtained upon request addressed to the U.S. Nuclear Regulatory Comission, Washington, D.C. 20555, Attention:

Director, Division of Reactor Projects I/II.

Dated at Rockville, Maryland this 20thday of June 1988.

FOR THE NUCLEAR REGULATORY C0411SSION hy Elinor G. Adensam, Director Froject Directorate 11-1 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation