(3 JUN 171988 Dennis L. Fadden I

Institute of Nuclear Power Operations Suite 1500, 1100 Circle 75 Parkway Atlanta, Georgia 30339-3064

Dear Mr. Fadden:

Enclosed for your information is our biweekly listing of generic comuni-cations being considered or under development by the NRC. staff. These include Bulletins (type coded BL on the list), Information Notices (IN) and Generic t

Letters (GL).

This listing includes all proposed generic comunications that had been reported to us by June 15, 1986.

Sincerely, Original Signed By j

Carl H. Berlinger 4

Carl H. Berlinger, Chief Generic Communications Branch Division of Operational Events Assessment Office of Nuclear Reactor Regulation

Enclosures:

As stated I

i DISTRIBUTION w/ enclosure All NRC Division Directors i

All NRC Branch Chiefs i

CERossi, NRR CHBerlinger, NRR DCKirkpatrick, NRR t

PDR

- Central Ffles.

<DCS'

~

00EA R/F OGCB R/F

]

DKirkpatrick R/F I

j Cd h^f l

OGCB:DOEA:NRR C/0GCB:00EA:NRR DCKirkpatJc 06//f/88 ud)

CHBerlinger

/

r 06/(6/88

[/fv 17 i

8806290363 i

PDR OHG PDR i

i r,.

.._.,,-n.,

_._,,,,._.n.._,

..,,_,, _ _,. n _ _.,.,,,,.,_-._,-,._

n--,-.,.

I' Pcgo No.

1 JUN 171988 06/15/88 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC TP ORIGIN.

SUBJECT CONTACT PHONE ISSUE OFFICE DATE IN NRR/DRIS ENVIRONMENTAL QUALIFICATION Jeff (301) 07/01/88 RVIB OF LIMITOROUE MOV ACTUATOR Jacobson 492-0996 TERMINAL BLOCKS & MARATHON 1600 TERMINAL BLKS BL AEOD/DSP THIMBLE TUBE WEAR AND OTHER Jack Ramsey (301) 08/01/88 PROBLEMS ASSOCIATED WITH FLOW 492-1167 INDUCED VIBRATION.

IN NRR/ DEST RECENT EVENTS CONCERNING Vern Hodge (301) 07/30/88 SPLB CONTROL ROOM HABITABILITY.

492-1169 BL REGION HEAT EXCHANGER FOULING.

Vern Hodge (301) 09/01/88 II 492-1169 IN NRR/DOEA BWR VESSEL OVERFILL EVENTS.

Pat (301) 07/01/88 EAB Baranowski 492-1156 BL NRR/DOEA THERMAL STRESSES IN PIPING Roger (301) 07/15/88 EAB CONNECTED TO REACTOR COOLANT Woodruff 492-1180 SYSTEMS.

GL NRR/DOEA ADEOUACY OF DESIGN CHANGE-

Schulten, (301) 06/30/88 EAB EVALUATE CAPACITY &

Fields 492-1192 CAPABILITY OF ELEC POWER SYS TO SUPPLY LOADS FOLLOWING DESIGN CHANGE GL NRR/DOEA DEBRIS IN STEAM GENERATORS Roger (301) 06/30/88 EAB CAUSING TUBE DEGRADATION.

Woodruff 492-1180 IN NRR/DOES ERRORS IN CALIBRATION OF Fred (301) 08/01/88 EAB LEAD / LAG AND RATE CIRCUITS IN Burrows 492-0783 REACTOR PROTECTION SYSTEMS.

IN NRR/ DEST UNINTENTIONAL FUEL POOL Vern Hodge (301) 08/01/88 SPLB DRAINAGES.

492-1169 i

IN REGION MARKING, HANDLING, CONTROL, Bernard (301) 06/30/88 II STORAGE AND DESTRUCTION OF Mann 492-3138 SAFEGUARDS INFORMATION GL NRR/DLPQ SAFITY PARAMETER DISPLAY Dick (301) 08/01/88 SYSTEM - ACCEPTABLE METHODS Eckenrode 492-1014 OF IMPLEMENTING REQUIREMENTS GL RES/DE SAFETY RELATED MOTOR OPERATED Owen (301) 06/30/88 EIB VALVE TESTING AND INSPECTION Rothberg 492-3815

Page No.

2 06/15/88 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC TP ORIGIN.

SUBJECT CONTACT PHONE ISSUE OFFICE DATE GL NRR/ DEST INSTRUMENT AIR SYSTEM William (301) 08/01/88 SPLB PROBLEMS AFFECTING SAFETY Lefave 492-0862 RELATED EQUIPMENT IN RES/EME LIMITOROUE SMA SPRING Jerry (301) 07/29/88 DEFORMATION Weidenhamer 492-3839 IN NRR/PnEA CHANGE IN FORMAT FOR NRC Vern Hodge (301) 08/01/S8 OGCB GENERIC COMMUNICATIONS 492-1169 GL NRR/DLPQ PUBLICATION OF NUREG/BR-0122 Susan (301) 07/30/88 LOLB EXAMINERS HANDBOOK FOR Shankman 492-1053 DEVELOPING OPERATOR LICENSING EXAMINATIONS GL RES/DE SIPPLEMENT TO GENERIC LETTER John (3C1) 07/01/88 SSEB 87-11 DEALING WITH ARBITRARY O'Brien 869-8213 INTERMEDIATE PIPE RUPTURE REQUIREMENTS IN NRR/DOEA ENVIRONMENT ENDUCED FAILURES R F Scholl (301) 06/30/88 EAB OF SAFETY EQUIPMENT 492-1171 BL NRR/ DEST REQUIREMENTS FOR RESOLUTION W C Lyon (301) 06/30/88 SRXB OF GI99 FOR OPERATION WITH 492-0891 LOWERED RCS INVENTORY AND FOR RELATED ISSUES GL NRR/ DEST INSERVICE INSPECTION OF WS (301) 01/30/89 EMTB PRESSURE RETAINING WELDS IN Ha:elton 492-0911 THE REACTOR VESSEL GL AEOD LICENSEE COMMITMENTS FOR John (301) 06/30/88 EMERGENCY RESPONSE DATA Hickman 492-4155 SYSTEM (ERDS) IMPLEMENTATION GL NRR/ DEST NRR RECOMMENDATION ON ISI OF Chen P Tan (301) 07/01/88 ESGB MARK I & II STEEL 492-0929 CONTAINMENTS, REFUELING CAVITIES & ASSOC DRAINAGE SYS IN NRR/DOEA EFFECTS OF SWITCHYARD R F Scholl (301) 06/30/88 OEAB MODIFICATIONS ON EMERGENCY 492-1171 POWER SOURCES IN NRR/DOEA SUPP TO IN 88-11: POTENTIAL R Scholl (301) 07/30/88 OEAB LOSS OF MCC AND/OR SWITCH 492-1171 BOARD FUNCTION DUE TO FAULTY TIE BOLTS

f Pcg,9 No.

3 06/15/88 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC TP ORIGIN.

SUBJECT CONTACT PHONE ISSUE OFFICE DATE GL ARM /SEC PURCHASE OF GSA APPROVED D Kidd (301) 07/29/88 SECURITY CONTAINERS 492-4124 IN NRR/DOEA FAILURE OF GE MODEL AK2-25-2 Nick Fields (301) 06/30/88 OEAB REACTOR TRIP BREAKER TO 492-1173 OPERATE IN NRR/DREP HIGH RADIATION HAZARDS FROM Charles (301) 07/01/88 RPB INCORE DETECTORS Hinson 492-3148 GL RES/DRPS INDIVIDUAL PLANT EXAMINATION Farouk (3D1) 06/30/88 RHFB FOR SEVERE ACCIDENT Eltawila 492-3543 VULNERABILITIES - 10 CFR 50.54 GL NRR/ DEST RESOLUTION OF GENERIC ISSUE Om P Chopra (301) 10/30/88 SELB B-56, DIESEL RELIABILITY 492-0835 GL NRR/ DEST INSERVICE TESTING FOR PUMPS Ted (301) 09/03/88 EMEB AND VALVES Sullivan 492-0901 IN NRR/DREP INTERPRETATION OF BIDASSAY John (301) 08/01/88 PRPB MEASUREMENTS Buchanan 492-1097 ASSESSMENTS OF INTAKES IN AEOD TESTING PRESSURIZER SAFETY Mary S (301) 07/15/88 VALVES WITH LOOP SEAL FILLED Wegner 492-7818 USING AN HYDRAULIC ASSIST DEVICE GL NRR/DOEA LINE ITEM TECHNICAL Tom Dunning (301) 08/01/88 OTSB SPECIFICATION IMPROVEMENT -

492-1189 s

REMOVAL OF FIRE PROTECTION REQUIREMENTS GL NRR/DOEA LINE ITEM TECHNICAL Tom Dunning (301) 09/01/88 OTSB SPECIFICATION IMPROVEMENT -

492-1189 REMOVAL OF t N '.LE SPECIFIC PARAMETER L','..TS GL NRR/DOEA LINE ITEM TECH SPEC Tom Dunning (301) 09/15088 OTSB IMPROVEMENT-RELOCATION OF 492-1189 RADIOLOGICAL EFFLUENT REQUIREMENTS TO OFFSITE DOSE CALCULATION MANUAL GL NRR/DOEA LINE ITEM TECHNICAL Tom Dunning (301) 10/15/88 j

OTSB SPECIFICATION IMPROVEMENT -

492-1189 REMOVAL OF COMPONENT LISTS i

l 1

l

  • ~

Pcg,e No.

4 06/15/08 PROPOSED GENERIC COMMUNICATIONS

\\

IN PREPARATION WITHIN THE NRC TP ORIGIN.

SUBJECT CONTACT PHONE ISSUE OFFICE DATE t

IN NMSS/AB EVALUATION OF EXTERNAL Harriet (301) 07/01/88 EXPOSURE READINGS OF LICENSEE Karagianni 492-0366 PERSONNEL DOSIMETERS IN NRR/ DEST REPORT OF THE FAILURE OF A Keneth (301) 07/15/98 i

EMEB MAIN STEAM ISOLATION VALVE AT Dempsey 492-0918 l

WATERFORD UNIT 3 IN NRR/DOEA 87-41 SUPP 1 CIRCUIT BREAKER Jack Ramsey (301) 07/15/88 OGCB FAILURES DUE TO LOOSE 492-1167 CHARGING SPRING MOTOR MOUNTING BOLTS IN REGION V FIRE IN PENETRATION SEALS Vern Hodge (301) 08/01/88 492-1169 9

l

_