Forwards Insp Rept 50-382/88-10 on 880418-22 & Notice of Violation.Unresolved Item Identified in Paragraph 2.a of Rept
ML20195J430
Person / Time
Site: Waterford Entergy icon.png
Issue date: 06/17/1988
From: Callan L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Dewease J
LOUISIANA POWER & LIGHT CO.
Shared Package
ML20195J436 List:
References
RTR-NUREG-0588, RTR-NUREG-588 NUDOCS 8806290132
Download: ML20195J430 (3)


See also: IR 05000382/1988010

Text

_ _ _

__

_

_______ ____

3 r.

-JUN I 71988

In Reply Refer To:

!

Docket:

50-382/88-10

Louis'iana Power & Light Compa'ny

ATTN:

J. G. Dewease, Senior Vice President

l

Nuclear Operations

317 Baronne Street

New Orleans, Louisiana 70160

Gentlemen:

This refers to the inspection conducted by Mr. J. R. Boardman of this office

during the period April 18-22, 1988, of activities authorized by NRC Operating

License NPF-38 for the Waterford Steam Electric Station, Unit 3, and to the -

'

discussion of our findings with Mr. N. Carns and other members of your staff at

the conclusion of the inspection.

The area examined during the inspection was your corrective action system.

Within this area, the inspection consisted of selective examination of

procedures and representative records, interviews with personnel, and-

observations by the NRC inspector.

The inspection findings are documented in

the enclosed inspection report.

During this inspection, it was found that certain of your activities were in

violation of NRC requirements.

Consequently, you are required to respond to

this violation, in writing, in accordance with the provisions of Section 2.201

of the NRC's "Rules of Practice," Part 2, Title 10, Code of Federal

Regulations.

Your response should be based on the specifics contained in the

Notice of Violation enclosed with this letter.

An unresolved item is identified in paragraph 2.a. of the enclosed inspection

report.

The response directed by this'1etter and the accompanying Notice is not subject

to the clearance procedures of the Office of Management and Budget as required

by the Paperwork Reduction Act of 1980, PL 96-511.

i'

09 8

Q

Reconcu k

,1

RIV:RE d

JEGa[liardo

fS

C:0RP/A

0:

C:0R

JJGagllli~ardo

JRBoardfran/tw

JLh ilhoan

DDChamberlain LJCallan

C/k /88

//)')/88

b/}D/$8

h/0;/88

GA]/88

(tl17

8-

$$A93b5 SSSUhga

\\(

XCOt \\

0

-

-

m

y

s

+

..
.-

-

Louisiana Power & Light Company-

-2-

Should you have any questions concerning this inspection, we will be pleased to-

discuss them with you.

Sincerely,

Originu ,,Q "1

1 B. B

L.?'J. Callan, Director

DivisionofReactorProjects

Enclosures:

1.

Appendix A - Notice of Violation

2.

Appendix B - NRC Inspection Report

50-382/88-10

cc w/ enclosures:

Louisiana Power & Light Company

ATTN:

G. E. Wuller, Onsite

-Licensing Coordinator

P.O. Box B

Killona, Louisiana 70066

Louisiana Power & Light Company

ATTN:

N. S. Carns, Plant Manager

P.O. Box B

Killona, Louisiana 70066

Middle South Services

ATTN:

Mr. R. T. Lally

P.O. Box 61000

New Orleans, Louisiana 70161

Louisiana Power & Light Company

ATTN:

R. F. Burski,. Acting Manager

Nuclear Safety and Regulatory

Affairs

317 Baronne Street

P.O. Box 60340

New Orleans, Louisiana 70160

Louisiana Radiation Control Program Director

,

.

Louisiana Power & Light Company -

-3-

bec to DMB (IE01)

bec distrib. by RIV:

  • RRI

R. D. Martin, RA

  • Section Chief (DRP/A)
  • DRP
  • RPSB-DRSS
  • MIS System
  • Project Engineer, DRP/A
  • RSTS Operator
  • RIV File
  • D. Wigginton, NRR Project Manager
  • DRS

Lisa Shea, RM/ALF

H. Scott, Acting E0

  • R. E. Ireland
  • J.

R. Boardman

  • J. E. Gagliardo
  • w/766

l

!

!

-