Responds to NRC Compliance Bulletin 87-002 Re Fastener Testing to Determine Conformance W/Applicable Matl Specs. Plan Incorporating All Required Elements of Bulletin Implemented.Full Compliance Anticipated on or Before 880211
ML20195J042
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 01/11/1988
From: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
IEB-87-002, IEB-87-2, TXX-88029, NUDOCS 8801200456
Download: ML20195J042 (2)


Text

_ _ _ _ _ _ - _ _ _ _ _ _ _ _ - _. _ _ _ _ _ _ _ - _ _ _

l-log # TXX-88029 2

=

File # 10119 r

C Ref. # Bulletin 87-02 119 ELECTRIC sI,$,7,$dS<U.

January 11, 1988 Mr. Robert D. Martin Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, TX 76011

SUBJECT:

COMANCilE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 NRC COMPLIANCE BULLETIN N0. 87-02:

FASTENER TESTING TO DETERMINE CONFORMANCE WITH APPLICABLE MATERIAL SPECIFICATIONS

Dear Mr. Martin:

The subject Compliance Bulletin required that CPSES provide information within 60 days concerning receipt inspection and internal control procedures for fasteners and results of independent testing of fe.steners.

CPSES has developed and is implementing a plan which incorporates all required elements of Compliance Bulletin No. 87-02.

The plan includes discussion of receipt inspection techniques and procedures, fastener sampling plan, testing requirements, testing and further evaluation, if required.

Sampling and testing methods have taken longer than expected. We anticipate that all actions to comply with bulletin requirements will be completed no later than February 11, 1988.

Very truly yours, gDR ADDCK 050 5

[

/ g/7 8801200456 880111 W. G. Counsil BSD/grr c - U. S. Nuclear Regulatory Commision (original)

Document Control Desk Washington D. C. 20555 Resident inspectors, CPSES (3) 400 henk oms Street i B al Dallas. Tew HN) h a

TXX-88029 January 11, 1988 Page 2 of 2 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of

)

)

Texas Utilities Electric Com any

)

(Comanche Peak Steam Electric

)

Station, Units 1 & 2)

)

AFFIDAVIT W. G. Counsil being duly sworn, hereby deposes and says that he is Executive Vice President, Nuclear Engineering and Operations of TV Electric, the Applicant herein; that he is duly authorized to sign and file with the Nuclear Regulatory Commission this response to NRC Bulletin 87-02 that he is familiar with the content thereof; and that the matters set forth therein are true and correct to the best of his knowledge, information and belief.

I

'47tM W. G. Counsil Executive Vice President, Nuclear Engineering and Operations STATE OF TEXA5

)

)

COUNTY OF DALLAS

)

Sub.cribed and sworn to before me, a Notary Public in and for o,/-

, on this

//a(_ day of d amo m o.

, 1988.

/

6/

d 0rr,

+ A v.), w

.n-cNotary Public/

My commission expires? 3 /J 90