ML20195J010
| ML20195J010 | |
| Person / Time | |
|---|---|
| Site: | Fort Saint Vrain |
| Issue date: | 01/15/1988 |
| From: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | |
| Shared Package | |
| ML20195J000 | List: |
| References | |
| 50-267-87-25, NUDOCS 8801200445 | |
| Download: ML20195J010 (1) | |
See also: IR 07100018/2011021
Text
m
,
4
I
APPENDIX A
-NOTICE OF VIOLATION
<
'
- Public Service Company of Colorado-
Docket: 50-267
Fort St. Vrain
'
License: DPR-34
- ,.
,
During-an NRC inspection conducted ~on October 18,through November 21, 1987, a
.
'
violation of.NRC requirements was identified. The violation involved failure
to make management notifications required by Section 2.1 and Attachment 2 of
the "Fort St. Vrain Medical Emergency Plan," Issue 20.
In accordance with the
.
"General. Statement of Policy ~'and Procedure for NRC Enforcement Actions," 10 CFR
,
Part 2, Appendix C (1987), the violation is listed below:
The licensee's Technical Specification AC 7.4.a.5 requires written
-procedures be established and implemented covering emergency plan
implementation.
The "Fort St. Vrain: Medical . Emergency Plan (MEP)," Issue 20, including
Procedural Deviation Reports 87-2039 and 87-2042 prescribes those actions
taken in the event of onsite injury to personnel.
'
Contrary to the abow, on October 26, 1987, the shift supervisor failed
to make the management notifications required by Section 2.1 and
Attachment 2 of MEP, Issue 20 when a contractor electrician had injured
himself in a fall while onsite and had been transferred by amublance to
an off site medical facilty.
.
This is a Severity Level V violation.
(Supplement;VIII.E)(267/8725-01)
Pursuant to the provisions of 10 CFR 2.201,
is hereby required to submit a
written statement or explanstion to this Office within 30 days of the date of
4
the letter transmitting this Notice. This reply, should include for each
-violation:
(1) the reason for the violation if admitted, (2) the corrective
i
steps that have been taken and the results achieved, (3) the corrective steps
that will be taken to avoid further violations, and (4) the date when full
compliance will be achieved. Where good cause is shown, consideration will be
given to extending the response time,
,
,
n
Dated at Arlington, Texas,
1987.
this
Ag a
day of
%
L
8801200445 080115
DR
ADOCK 050002e7