Forwards Response to Six Specific Actions Requested,Per IE Compliance Bulletin 87-002, Fastner Testing to Determine Conformance W/Application Matl Specs
ML20195H480
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 01/12/1988
From: Murphy W
VERMONT YANKEE NUCLEAR POWER CORP.
To: Russell W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
FVY-88-03, FVY-88-3, IEB-87-002, IEB-87-2, NUDOCS 8801200135
Download: ML20195H480 (106)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

VERMONT YANKEE NUCLEAR POWER CORPORATION FVY 88-03 RD 5, Box 169, Ferry Road, Brattleboro, VT 05301

,,,L,y,

. p' ENGINEERING CFFICE 1671 WORCESTER ROAD FR AMING, LAM, MASS ACHUSETTS 01701 e

T EtEPHONE 617-672-6100 January 12, 1988 U. S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

William T. Russell Regional Administrator

References:

a)

License No. OPR-28 (Docket No. 50-271) b)

Letter, USNRC to All Holders of Operating Licenses for Nuclear Power Reactors, NVY 87-173, dated 11/6/87 (IE Compliance Bulletin 87-02)

Dear Sir:

Subject:

Vermont Yankee Response to IE Compliance Bulletin No. 87-02, "Fastener Testing to Determine Conformance with Applicable Material Specifications" By letter dated November 11, 1986 (Reference b), the NRC's Office of Nuclear Reactor Regulation requested that licensees 1) review their receipt inspection requirements and internal controls for fasteners; and 2) indepen-dently determine, through testing, whether fasteners (studs, bolts, cap screws and nuts) in stores at their facilities meet required mechanical and chemical specification requirements.

In accordance with the subject Bulletin 87-02, the following information is previded in response to the six specific actions requested.

ACTION ITEM 1 describes the fastener characteristics examined during receipt inspection and internal controls implemented during storage through end use.

ACTION ITEMS 2 AND 3 As prescribed, eleven (11) safety related fasteners, ten (10) cafety related nuts, ten (10) non-safety related fasteners, and ten (10) non safety related nuts were selected from current, in use, stock.

Attempts were made to select materials representative and proportional to plant use.

In addition, all portions of the selection process were performed in concert with the two Vermont Yankee NRC resident inspectors.

8801200135 880112 PDR ADOCK 05000271 y i G

PDR t

i

r VERMONT YANKEE NUCLEAR POWER CORPORATION U. S. Nuclear Regulatory Commission January 12, 1988 Page 2 ACTION ITEMS 4 AND 5 Chemical, hardness, and mechanical testing of the selected fasteners was performed by a Vermont Yankee approved vendor (Dirats Laboratories) as spe-cified by the subject Bulletin Action Item 4.

Results of all tests "ith sup-porting information is provided in accordance with Bulletin Action item 5 in.

Based on the results of the required testing, the following specimens were identified to have single elements out of prescribed range.

Nut

  1. VY-87-02-13SR-N Carbon 0.05% Lo*

Nut

  1. VY-87-02-18SR-N Chrome 0.44% Lo*
  • Below specified range Based upon the review of the above discrepancies, additional testing was performed on specimens taken from the same (respective) lots. This testing included chemical analysis, hardness testing, and proof testing performed in accordance with the requirements of ASTM A-194.

For those nuts from the same lot as specimen #VY-87-02-13SR-N, all sub-sequent test results were within specified chemistry and hardness ranges.

Proof tests were also performed and the results were satisfactory.

For those nuts from the same lot as specimen #VY-87-02-18SR-N, subsequent test results were identical to the earlier test in that chemistry analysis iden-tified that the chrome content was typically 0.44% low. All other chemistry and hardness was within specified range.

Proof tests were also performed and the results were satisfactory.

Specific results of this subsequent testing is provided in Enclosure 3.

A review and evaluation of the chemical properties, hardness tests plus subsequent proof testing of these specimens concludes that had these items been used, their structural functionality would rat have been impaired and, there-fore, would have had no adverse affect on the operability of safety related plant components.

ACTION ITEM 6 Based on the above testing and supporting evaluation and the review of existing procedures and material controls, no other actions are planned at this time.

l

VERMONT YANKEE NUCLEAR POWER CORPORATION U..S. Nuclear Regulatory Commission January 12, 1988 Page 3 Completion of this response involved approximately 400 manhours of engi-neering time and $6,000 to perform the testing.

We trust that the information provided is responsive to the request of the subject Bulletin; however, should you have any questions or require additional information, please contact us.

Very truly yours, VERMONT YANKEE NUCLEAR POWER CORPORATION h

Warren M

Vice President d

Manager of Operations

/dm cc:

USNRC Document Control Desk (Original)

STATE OF VERMONT)

)ss WINDHAM COUNTY )

Then personally appeared before me, Warren P. Murphy, who, being duly sworn, did state that he is Vice President and Manager of Operations of Vermont Yankee Nuclear Power Corporation, that he is duly authorized to execute and file the foregoing document in the name and on the behalf of Vermont Yankee Nuclear Power Corporation and that the statements therein are true to the best of his knowledge and belief.

pt M. ccy, V

()

O AL M.

PGw l

Diane H. McCue Notary Public gg My Commission Expires February 10, 1989 l

o

/

COUNU' l

ENCLOSURE 1 INSPECTION AND CONTROL OF FASTENERS AT VERMONT YANKEE A.

Prior to receipt inspection, fasteners are subjected to a cursory inspection to verify these items were not subjected to shipping damage.

This inspec-tion will identify rough handling, excessive exposure, contamination, and other environmental or shipping influences.

B.

The formal Receipt Inspection of safety related fasteners records, verifies, or examines the following characteristics:

1.

Verification of the delivered material agains the Purchase Order:

a.

Purchase order number b.

Item number c.

Description d.

Part number e.

Serial / heat / batch lot number f.

Drawing / spec, number g.

Quantity received and quantity inspected h.

Storage level 2.

Notification / Shipping Point Acceptance a.

Verification of pre-shipment surveillance, witness of receipt inspection, or shipper acceptance (as required by Purchase Order).

3.

Identification and Marking a.

Part numbers, heat numbers, lot numbers, and/or serial numbers match associated documentation (as required by the Purchase Order).

4.

Certification (as reauired by the Purchase Order) a.

C of C or certified material test reports traceable to Purchase Order and the item.

b.

C of C or documentation that the item was manufactured, inspected, tested, and/or supplied in accordance with the Purchase Order requirements.

1.

C of C's should contain the following:

a.

Signature of a qualified vendor representative.

b.

Reference to the Purchase Order and item.

1 j

c.

Adequate detail to provide assurance that the vendor has understood and complied with the requirements of the Purchase Order.

l l

L

ENCLOSURE 1 (Continued) d.

When certifying statements do not provide word-for-word correspondence to the certification requested, verification that the vendor has given a clearly binding acknowledgment of responsibility for compliance must be done, e.

Statements such as "similar to", "equivalent to", or "typical" must be subjected to further technical evaluation by cognizant engineering to determine acceptability.

2.

Certified Test Reports should contain the following as appli-l cable:

I a.

Material spec. number and year, b.

Results of tests of the chemical and physical properties by heat or lot number.

c.

A written statement certifying that the test results are correct or that the requirements of the spec have been met.

d.

Signature of a qualified vendor representative.

Other documentation as required by the Purchase Order (Obtain technical 5.

l review and acceptance as necessary).

l l

a.

Nondestructive testing 1.

Type of test and procedure used.

2.

Lot or batch number of material used.

1 3.

Features of surfaces tested.

4.

Resulto of test and acceptance.

(

5.

Signature of test personnel and date.

I 6.

Signature of level II or III reviewer and date.

b.

Testirg Personnel Qualification Records 1.

Name of individual and method and level to which certified.

2.

Results of general, specific, and practical examinations.

3.

Signature of certifying authur:ty.

c.

Heat Treatment Records 1.

Actual furnace recceder chart showing time iten was held at tem-perature.

)

l

~-

w

ENCLOSURE 1 (Continued) 2.

Procedure, which should describe the process.

3.

Type of quench.

4.

Identification of item treated and date.

5.

Identification of thermocouples.

6.

Signature of vendor's or manufacturer's representative.

7.

Above documentation traceable to the associated item and the Purchase Order.

8.

Above documentation must be reviewed by cognizant engineering personnel.

6.

Protective coatings, covers, seals, inert gas blankets, and special packaging as required by the Purchase Order.

a.

Present and intact as required by quality level, b.

At required by vendor special packaging procedure provided with shipment.

7.

Desiccant as required by the Purchase Order, a.

Present and not saturated or damaged.

8.

Physical Condition a.

Visual Inspection 1.

Configuration agrees with Purchase Order requirements.

2.

No cracks or discontinuities exist at the junction of the head and shank.

3.

Threads are clean and in good condition; free from nicks, cracks, burrs, and tool induced defects (blunt threads, double threads, etc).

b.

Dimensional Inspection 1.

Utilizing the appropriate calibrated measuring and test equip-ment and the Machinery's Handbook or the applicable ANSI Standard, the following are inspected as applicable:

a.

Major or minor diameter b.

Threads per inch c.

Shank length

ENCLOSURE 1 (Continued) d.

Working length of thread e.

Nut thickness f.

Washer diameter and thickness g.

Overall length h.

Correct marking C.

Control of safety related fasteners (storage and issuance) is detailed as follows:

1.

Upon successful completion of the receipt inspection, safety class fasteners are identified with a red "P" tag which contains the following information as applicable:

a.

Purchase order number b.

Safety class c.

Stock code and description d.

Vendor / manufacturer part number e.

Serial / heat / lot / batch number f.

Storage location and level g.

Application h.

EQ and shelf life data i.

Inspector's initials and date 2.

At the completion of acceptance of non-safety related fasteners, the fasteners may be identified with a green tag which reflects the following as applicable:

a.

Purchase order number b.

Stock code and oescription c.

Vendor / manufacturer part number d.

Level of storage e.

Inspector's initials and date NOTE:

Non-safety related fasteners may be stored without tags.

Any material without the red "P" tag must be assumed to be non-safety related.

ENCLOSURE 1 (Continued) 3.

Except as required by the material specification, safety related

-fasteners one inch nominal diameter and smaller, and other pro-ducts, where the largest space available for marking is one inch in any direction, need not be individually marked provided that they are stored in packages or containers which are clearly identified by legible marking to insure positive identification of the material. All other fasteners are marked with their purchase order number as follows:

a.

Electrochemical etching may be used on:

1.

Hardened material with minimum required yield strength of 90,000 psi or greater.

2.

Cobalt based materials.

3.

Pressure boundary parts less than 1/8 inch thick, b.

Vibration marking 1.

Materials greater than 1/8 inch thick.

c.

Stamping 1.

Materials greater than 4 inch thick, d.

Ink markers 1.

Ink markers are the least desirable type of markers and are only used as a last resort.

The chemical content of the ink is monitored for acceptability as required by the ANSI standards.

e.

Other issuing controls 1.

Non-safety class material cannot be issued for safety class work.

Personnel verify that the issued safety class material is properly identified and marked with a red "P"

tag, 2.

Issued material can only be used for the application identified.

Other usage required the return of the material for re-issue.

3.

Administrative controls are in place to insure main-tenance of the above during other than normal working

hours, 4.

Unused safety related material returned to the Stores Ceoartment is required to be receipt inspected by the E igineering Support Department prior to being returned to stock.

ENCLOSURE 1 (Continued) 5.

Unused non-safety related material returned to the Stores Department is visually inspected for ser-viceability prior to returning it to stock.

l 4.

Storage:

a.

Fasteners are stored in specified locations that provide the required protection for the item and accessibility for withdrawal when required. Safety class fasteners are stored in a manner suitable to the quality level identified in the purchasing document and in accordance with ANSI N45.2.2-1972.

Both safety class and non-safety class fasteners may be stored in the same general location but are subject to the controls described in C above.

1.

Storage areas are inspected on a quarterly basis for the following as applicable:

a.

Protective covers in place, b.

Temporary preservatives intact.

c.

Desiccants monitored.

d.

Identifiction and marking intact.

e.

Physical damage.

f.

Cleanliness.

g.

Access controls in force.

h.

Protection from rodents, fires, weather, or other factors that could damage stored items.

i.

Requirements for special storage addressed.

J.

Any unsatisfactory items discovered during the course of the inspection are documented and the corrective action addressed.

5.

Issuing:

a.

Fasteners are issued utilizing a material issue slip.

The following is recorded prior to issuance:

1.

Date and end use of the material.

2.

Authorization for use.

3.

Material description, part number, serial / heat / lot / batch numbers, safety class, purchase order.

4.

Quantity issued.

i ENCLOSURE 2 FASTENER TESTING DATA NOTE:

The following acronyms are used in the Enclosures 2 and 3.

ANSI American National Standards Institute ASTM American Society for Testing Materials 8

Boron C

Carbon Co Cobalt C of C Certificate of Compliance CMTR Certified Material Test Report Cr Chrome CS Carbon Steel Cu Copper ELG in 4D Elongation in 4 Diameters F

Fastener FE Iron HHCS Heavy Hex Carbon Steel HRB Rockwell Hardness Scale B HRC Rockwell Hardness Scale C Mn Manganese Mo Molybdenum N

Nut ND Not Detected Ni Nickel NNS Non Nuclear Safety P

Phosphorus l

Pb Lead R/A Reduction in Area j

i REM Remainder S

Sulfur SAE Society of Automotive Engineers Si Silicon SR Safety Related SS Stainless Steel l

V Vanadium YS Yield Strength l

1 Page 1 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-1SR-F Fastener

Description:

5/8" -11 X 4" CS Stud Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A193 GR B7 Head Marking (Specification and Manufacturer):

87

+

Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Radwaste Cask / Transportation Vendor:

NUS Process Services QA Requirements Imposed on Vendor:

C of C Licensee Representative:

//N/88 O.

.ANgued I **

Signature t9erro

Page 2 of 82

{

ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ID# VY-87-02-1SR-F MECHANICAL ANALYSIS HARDNESS TENSILE, KSI YIELD @ POINT, KSI ELG IN 40, }

R/A, %

HRC 32.5 128.5 110.2 19.2 65.4 CHEMICAL ANALYSIS g1 E.1 3

J1 FE REM P

.029 Si

.23 Mn

.90 Cr

.90 Mo

.17 S

.010 C

.40

Page 3 of 62 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-2SR-F Fastener

Description:

7/8"-9x2 3/4 CS Hachine Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

  • Commercial Head Marking (Specification and Manufacturer):

Unstamped - No manufacturer stamp Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Radwaste Cask / Transportation (This fastener was purchased to maintain the configuration of a 6-inch sheet metal cap over a lifting lug during transportation)

Vendor:

NUS Process Services QA Requirements Imposed on Vendor:

C of C Licensee Representative:

M6 htye,fu 6. bM Date Signature

  • The associated purchase order procured numerous items for a Radwaste Shipping Cask. This fastener was designated as "commercial" by the supplier.

No speci-fication or material strength requirements were applied to this fastener.

j

Pag 2 4 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO 2)

ID# VY-87-02-2SR-F MECHANICAL ANALYSIS HA80 NESS TENSILE, KSI YIELD @ POINT, KSI ELG IN 40, %

R/A, %

HRB 90.0 75.5 74.4 11.8 59.5 CHEMICAL ANALYSIS, El El

)

[L, 3

FE REM P

.025 Si

.02 Mn

.42 Cr

<.01 Mo

.01 S

.0^d C

.07 8

ND<.0003

Pag) 5 cf.82.

ENCLOSURE 2 FASTENER TESTING DAT- (SHEET NO. 1) 108 VY-87-02-3SR-F Fastener

Description:

4"-13X1% CS Socket Head Cap Screws Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N.45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A-574 Head Marking (Specification and Manufacturer):

C 104 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Main Steam Vendor:-

Hardware Specialty Co. Inc.

QA Requirements Imposed on Vendor:

C of C Licensee Representative:

Signature

<. d O

8crbML Date

//a[#F le s

Page 6 of 82 i

l ENCLOS'JRE.2 DATA

SUMMARY

(SHEET NO. 2) 108-VY-87-02-3SR-f

[

MECHANICAL ANALYSIS HARONESS HRC 43.0 NOTE:

Based on length of 1 3/4" and in i

accordance with ASTM A-574, tensile test is not required.

CHEMICAL ANALYSIS Ek I

Ek I

Ek I

FE REM V

<.01 P

.013 Mn

.79 Ni

.01 Cr

.12 Pb

<.01 Mo

.20 S

.018 C

.37

~

i M

L r

P P

Ptga 7 cf 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) 10# VY-87-02-4SR-F Fastener

Description:

1%"-8x4" HHCS Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM 193 GR B7 Head Marking (Specification and Manufacturer):

BlS B7 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spare Parts Vendor:

Hardware Specialty Co.

QA Requirements Irooc~d on Vendor:

C of C CMTR 4

Licensee Representative:

Signature

.b C. g) yJ4 Date f //#3

/

um, l

Paga 8 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ID# VY-87-02-4SR-F MECHANICAL A!!ALYSIS HARONESS TENSILE, KSI YIELD @ POINT, KSI ELG IN 40, %

R/A, %

HRC 34.5 147.6 129,7 16.8 64.9 CHEMICAL ANALYSIS E

L E

FE REM P

.013 Si

.24 Mn

.83 Cr 1.01 Mo

.21 S

.011 C

.39 1

Paga 9 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-5SR-F Fastener

Description:

%"-20x1%" HHCS Description of Sample Stock Location:

Utility Strokroom in accordance Ndth ANSI N45.2.2 Quality Level B Material Specification as Documented by litansei r.ecords:

ASTM 193 GR B7 Head Marking (Specification and Manufactu.~0r):

BlS B7 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spare Parts Vendor:

Hardware Specialty Co.

QA Requirements Imposed on Vendor-C of C Licensee Representative:

Signature he MEM Date

//#/58 mp

Page 10 of-62 i

ENCLC3 ORE 2 DATA

SUMMARY

(SHEIT NO. 2) 10# VY-87-02-5SR-F M,ECHANICAL ANALYSIS HARDNESS TENSILE, KSI YIELD @ POINTu_]g5[ RLG IN 40, %

R/A, %

HRC 31.0 143.3 132.8 12.0*

59.2 Minimum elongation per ASTM A-193 is 10%. Based upon the unic,u? con-figuration cf the test coupon and the increased potential for error, this individual result is submitted for itifo mation and cannot ee used exclusively. Tensile atrength and yield strength are identified as the valid indicators for e.his bolt character. On this basis, this speci-men is determined acceptable and no further actior, is requir'eo.

s CHEMICAL AfiALYSIS E

1 E

E 3

FE REM P

<.002 Si

,21 Mn

.81 Cr

.87 Mo

.18 S

.618 C

.39 l

l l

r l

l l

w w,

n

.~m ws

-a, u

Page 11 of 82 r

ENCLCSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-6SR-F Fastener Descript-lon:

h"-20x3/4" HHC5 Dolt Det.cription of Samp'a Stock Location:

Utility Stockroom ir, accordance with ANGI N45 2.2 Quality Level B Material Srecification es Documented by Licensee Records:

[

ASTM A193 Gr B7 m

Fead Maskir.3 (Specification and Manufacturer):

E O

B7 BLO e

C1sss/ Procurement Level:

Gafety Related General Plant Application (e.g., Precsure Boundar,, Structural)

Spares Vendor:

A&G Engineering Co.

QA Requirements Irposed on Vendor:

C of C CMTR Licensee Representttive:

~

m

Page 12 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-6SR-F MECHANICAL ANALYSIS HARONESS TENSILE, KSI YIELO @ POINT, KSI ELG IN 40, %

R/A, %

HRC 36.0 141.8 130.0 14.8*

59.1 Minimum elongation per ASTM A-193 is 16%.

Based upon the unique con-figuration of th? test coupon and the increased potential for error, this individual result is submitted for information and cannot be used exclusively. Tensile strength and yield strength are identified as the valid indicators for this bolt character.

On this basis, this speci-ment is determined acceptable and no further action is required.

CHEMICAL ANALYSIS E

}

E,1 1

E FE REM P

.021 Si

.25 Mn

.88 Cr 1.01 Mo

.15 S

.020 C

.40 l

Paga 13 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) 10# VY-87-02-7SR-F Fastener Descriptien:

3/4"-10x2" HMCS Bolt Description of Sainple Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level 8 Material Specification as Documented by Licensee Records:

ASTM A193 G.

B7 Head Marking (Specification and Maruf&Jturer):

87 TB Class / Procurement f.evel:

Safety Rel,

^d General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

Hardwire Specialty Co., Inc.

i QA Requirements Imposed on Vendor:

C of C l

Licensee Representative:

unw Date

/[//M8 l

Signature onM O.

i

Paga 14 of 82 l

ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ID# VY-87-02-75R-F MECHANICAL ANALYSIS HARDNESS TENSILE, KSI YIELD @ POINT, KSI ELG IN 40, %

R/A, %

HRC 30.0 141.4 127.9 20.8 65.6 CHEMICAL ANALYSIS El 3

ji 3

E,1

}

FE REM P

.009 Si

.23 Mn

.87 Cr

.99 Mo

.22 S

.044 C

.39

Pags 15 of 02 i

i i

ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-8SR-F Fastener

Description:

3/4"-10x4" HHCS Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A193 Or 87 Head Marking (Specification and Manufacturer):

JB7 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Stock Vendor:

Hardware Specialty Co.,

Inc.

QA Requirements imposed on Verdor:

C of C Licensee Representative:

Signature A,% O. M cd Date

////[S8

Paga 16 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHFET N0, 2) 10# VY-87-02-8SR-F MECHANICAL ANALYSIS HARDNESS TE,f!SILE, KSI YIELD @ POINT, KSI ELG IN 40, %

R/A, %

HRC 30.0 136.3 133.5 17.7 60.2 CHEMICAL ANALYSIS E

1 fl 3

E_L.,

3 FE REM P

.022 Si

.19 Mn

.83 Cr

.97 Mo

.15 S

.019 C

.42 1

Paga 17 of 82 ENCLOSURE 2 FASTENER TESTING OATA (SHEET NO. 1) 10# VY-87-02-9SR-F Fastener

Description:

7/8"-9x6" HHC3 Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Material Specification as Documented by Licensee Records:

ASTM A193 GR B7 Head Marking (Specification and Manufacturer):

BlS B7 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Strtictural)

Spares Vendor:

Hardware Specialty Co., Inc.

QA Requirements Imposed on Vendor:

C of C Licensee Represer.tative:

Signature ow<k 0 dkerdA Date

/// B5

Page 18 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ID# VY-87-02-9SR-F MECHA*;ICAL ANALYSIS HARONESS TENSILE, KSI YIELO O POINT, KSI ELG IN 40, %

R/A, %

HRC 33.0 150.1 137.1 17.2 63.8 CHEMICAL ANALYSIS E

I E

A E

I FE REM P

.007 Si

.24 Mn

.88 Cr

.94 Mo

.17 S

.017 C

.41 t

l 1

y,

Page 19 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-10SR-F Fastener

Description:

3/4" - 10 x 4" HHSS Description of Sample Stock Locotion:

Utility Stockroom in accordance with ANSI N 45.2.2 Material Specification as Documented by Licensee Records:

ASTM A193 GR 88 Head Marking (Specification and Manufacturer):

JB8 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

Hardware Specialty Co., Inc.

QA Requirements Imposed on Vendor:

C of C Licensee Representative:

Signature bai,E 6.

O Date 3[#/6F

Paga 20 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) ids VY-87-02-10SR-F MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HARDNESS TENSILE, KSI YIELD @ POINT, KSI ELG IN 40, %

RfA _3 g

HRB 92.5 104.8 49.0 67.3 76.9 CHEMICAL ANALYSIS E

3 E

3 E

3 FE REM P

.023 Si

.57 Mn 1.05 Ni 8.21 Cr 18.13 Mo

.03 S

.022 C

.08 l

l L_

Page 21 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-11SR-F Fastener

Description:

5/16" - 18 x 3/4" HHSS Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI 45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A193 GR. B8 Head Marking (Specification and Manufacturer):

388 4 TB Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Stock Vendor:

Hardware Speciality Co., Inc.

QA Requirements Imposed on Vendor:

C of C i

Licensee Representative:

i Signature Me4,,,a A M :

ph 4

cate

Paga 22 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY 87-02-11SR-F MECHANICAL ANALYSIS HARDNESS TENSILE, KSI YIELD 0 POINT, KSI ELG IN 4D, %

R/A, %

HRB 81.5 88.8 46.4 56.0 73.6 CHEMICAL ANALYSIS E

E i

E FE REN P

.023 Si

.49 Mn 1.63 Ni 12.09 Cr 18.54 S

.017 C

.05 NOTE:

This item was compared against ASTM A-193, 1974.

Page 23 of 62 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-12SR-N Fastener

Description:

3/4"-10 CS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N 45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

SAE J995 Head Marking (Specification and Manufacturer):

h3 2H Class / Procurement Level:

Safety Related General riant Application (e.g., Prer,sure Boundary, Structural)

Radwaste Cast / Transportation Vendor:

NUS Process Services QA Requirements Imposed on Vendor:

C of C Licensee Representativer l/(//#

Signature ctMa O. ht#4tj Date

Paga 24 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEEY NO. 2)

ID# VY-87-02-12SR-N MECHANICAL ANALYSIS HARONESS UTS-0.2% YS HRC 28.0 N/A N/A CHEMICAL ANALYSIS E

I E

I E

I FE REM P

.021 Si

.20 Mn

.73 Cr

.01 Mo

.01 S

.018 C

.43 l

t

r-Pag 2 25 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) 10# VY-87-02-13SR-N Fastener

Description:

5/8"-11 CS Plated Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level "B" Material Specificetion as Documented by Licensee Records:

ASTM A194 Grade 1 Head Marking (Specification and Manufacturer):

None Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Main Steam Isolation Valve Vendor:

Rockwell QA Requirements Imposed on Vendor:

C of C Licensee Representative:

d. M;di Date N6 Signature 6,<m,

. 4, -

Page 26 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 108 VY-87-02-13SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 96.5 N/A N/A CHEMICAL ANALYSIS E

E_L 3

h 3

P

.020 Si

.0S Mn

.43 Cr

.06 Mo

.02 S

.025.

C

.08*

  • This specimen was identified to have one element (C-0.05%-Lo) out of specifica-tion. A review and evaluation of the chemical properties and the hardneJs test concludes that had this item been used, its structural functionality would not have been impaired and, therefore, would have had no adverse affect on the plant.

Pcg2 27 of 82 l

ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) l ID# VY-87-0?-14SR-N Fastener

Description:

1%"-8 HHN-CS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A194 Grade 7 Head Marking (Specification and Manufacturer):

k9 7 AB Class / Procurement level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Reactor Water Cleanup System Vendor:

A&G Engineering Co.

QA Requirements Imposed on Vendor:

C of C CMTR Licensee Representative:

Signature he,d 6. M ff Date

/M

t Paga 28 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ID! VY-87-02-14SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 27.0 N/A N/A t

CHEMICAL ANALYSIS E

I E

I E

I

[

FE REM P

.020 Si

.24 Mn

.94 Cr 1.04 Mo

.16 S

.016 C

.38

Pcge 29 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-15SR-N Fastener

Description:

1/4"-20 CS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A194 Grade 2H Head Marking (Specification and Manufacturer):

U 2H Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spare Parts Vendor:

Hardware Specialty QA Requirements Imposed on Vendor:

C of C Licensee Represe,etative:

MT Signature ewM d fjmM Date m

Fago 30 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-15SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YL HRC 28.0 N/A N/A CHEMICAL ANALYSIS El 3

El 3

E,.1 3

FE REM P

.023 Si

.21 Mn

.76 Cr

.02 Mo

.01 S

.023 C

40 j

1 s

Pag 2 31 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-16SR-N Fastener

Description:

3/4"-10 SS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A194 Grade 8 Head Marking (Specification and Manufacturer):

T8 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

i Hardware Specialty Co., Inc.

QA Requirements Imposed on Vendor:

C of C Licensee Representative:

Signature bewaL l'.

nan +ei Date if// 33 i

Paga 32 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

I_03 W-87-02-16SR-N 0

MECHANICAL ANALYSIS HARONESS UTS 0.2% YS HRB 75.0 N/A N/A L

CHEMICAL ANALYSIS E

I E

I E

I I

FE REM P

.026 Si

.67 f

Mn

.88 Ni 9.64 Cr 18.72 S

.44 S

.013 C

.02 i

t l

l f

i i

i t

s 7-Page 33 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) 10# VY-87-02-17SR-N Fastener

Description:

3/8"-16 SS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A194 Grade 8 Head Marking (Specification and Manuf actur er):

T8 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

Hardware Speciality Co. Inc.

QA Requirements Imposed on Vendor:

C of C Licensee Representative:

Signature 21hjy F Ntr sk Date J /)ff

a i

Pags 34 of 82 r

ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-17SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 89.0 N/A N/A CHEMICAL ANALYSIS fl 1

fl 3

El

}

FE REM P

.027 Si

.82 Mn 1.40 Ni 8.99 Cr 18.36 1

Mo

.67 S

.005 C

.06 l

4 1

Paga 35 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-18SR-N Fastener

Description:

5/16-18 SS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N 45.2.2 Quality Level 8 Material Specification as Documented by Licensee Records:

ASTM 194 Grace 8 Head Marking (Specification and Manufacturer):

B8 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

Hardware Specialty Co., Inc.

QA Requirements Imposed on Vendor:

C of C Licensee Representative:

Signature

/ (?uE O.

  1. /,41 Date _/, //!MB

Page 36 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 36) 10# VY-87-02-18SR-N MECHANICAL ANALYSIS HARONESS UTS 0.2% YS HRB100.5 N/A N/A CHEMICAL ANALYSIS

)

E E

3 E

l FE REM P

.021 Si

.32 l

l l

Cu 3.08 Mn

.51 Ni 8.20 j

Cr 17.54 Co

.14 Mo

.13 S

.003 C

.03 I

l l

  • This specimen was identified to have one element (Cr-0.44%-Lo) out of speci-fication. A review and evaluation of the chemical properties and the hardness test concludes that had this item been used, its structural functionality would not have been impaired and, therefore, would have had no adverse affect on the plant.

Page 37 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) 10# VY-87-02-19SR-N Fastener

Description:

1\\"-8 CS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM 194 Grade 2H Head Marking (Specification and Manufacturer):

69 AMG 2H Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

A50 Engineering Co.

QA Requirements Imposed on Vendor:

C of C CMTR Licensee Representative:

Signature t_xy, 0. OH <*ti Date_/biI*e

r-Pago 38 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-19SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 29.0 N/A N/A CHEMICAL ANALYSIS E

I E

I E

I FE REM P

.018 Si

.16 Mn

.76 Cr

.01 Mo

.01 S

.016 C

.43

Pege 39 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-20SR-N Fastener

Description:

3/4"-10 CS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A194 Grade 2H Head Marking (Specification and Manufacturer):

8 2M AMC Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

ASG Engineering Co.

QA Requirements Imposed on Vendor:

C of C CMTR Licensee Representative:

Signature he115 0. 83yst Date

//"lB8

r i

Pcga 40 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-20SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 28.0 N/A N/A CHEMICAL ANALYSIS

{1 1

E_1 3

J1 1

FE REM P

.036 Si

.25 Mn

.93 Cr

.12 Mo

.02 S

.018 C

.38 t

Pago 41 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-21SR-N Fastener

Description:

7/8"-9 CS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

ASTM A194 Grade 2H l

l Head Marking (Specification and Manufacturer):

63 l

l 2H AMD Cless/ Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

A&G Engineering Co.

QA Requirements Imposed on Vendor:

C of C CMTR Licensee Represent 9tive.

Signature beM C.

M Date _ f, M M

Paga 42 of 82 ENCLOSURE 2 OATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-21SR-N MECHANICAL ANALYSIS HARONESS UTS 0.2% YS HRC 28.0 N/A N/A CHEMICAL ANALYSIS E

I E

I E

I FE REM P

.020 Si

.22 j

Mn

.78 Cr

.01 S

.019 C

.40 P

l

'l Page 43 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-22NFS-F Fastener

Description:

3/4"-10 x 4% CS Plated Bolt Description of Sample Stock location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

Head Marking (Specification and Manufacturer):

N/

Rockford Class / Procurement Level:

1 NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts t

Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

Signature

%p',

0 htwtE Date i/al88 i

  • Identification as SAE J429 is assumed or by physical inspection, Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification, i

I

Pag) 44 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ID# VY-87-02-22NNS-F MECHANICAL ANALYSIS HARONESS UTS 0.2% YS HRC 30.0 N/A N/A CHEMICAL ANALYSIS E

I E

I E

I FE REM P

.016 S

.025 C

.34

7 Paga 45 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) 10# VY-87-02-23NNS-F Fastener

Description:

3/4"-10 x 5" SS Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

316 Class / Procurement Level:

NNS General Plant Application (e.g., Presdare Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

i Date

//"/FF Signature he,d 6. O jdt n

  • Identification as ASTM A193 GR BBM is assumed or by physical inspection.

Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

1

1 Pag 2 46 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO 2)

IC# VY-87-02-23-NNS-F MECHANICAL ANALYSIS HARONESS UTS 0.2% YS HRB 94.0 N/A N/A CHEMICAL ANALYSIS E

I E

I E

I FE REM P

.036 Si

.58 Mn 1.47 Ni 11.68 Cr 17.43 Mo 2.86 S

.012 C

.04 i

Page 47 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) 10# VY-87-02-24-NNS-F Fastener

Description:

7/8"-9 x 3%" CS Bolt Description of Sample Stock Location:

Utility Stockroom in eccordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

(}S

'N

/

I Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

_ /,////f(F Signature er1E 6.

M*i Date i

  • !dentification as SAE J429 Class 5 is assumed or by physical inspection.

Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

I L

Pa00 48 of 82 i

ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ION VY-87-02-24NNS-F MECHANICAL ANALYSIS Hf90 NESS UTS 0.2% YS HRC 29.0 N/A N/A CHEMICAL ANALYSIS E

I E

3 E

1 FE REM P

.006 Si

.21 Mn

.85 Cr

.01 Mo

.01 S

.014 C

.36

e Pag) 49 of 82 l

l ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) 108 VY-87-02-25NNS-F Fastener Description 5/8"-11 x 24" SS Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

None Class /P;ocurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

Signature

  1. M 6.

Mvhee *L Date

//a/J8

  • Identification as ASTM A193 is assumed or by physical inspection.

Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

(________________-_--

Pcga 50 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

' i F

ids VY-87-02-25-NNS-F MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 33.5 N/A N/A i

CHEMICAL ANALYSIS i

f1 i

E1 1

!1

}

i FE REM P

.027 Si

.37 Mn 1.24 Ni 14.11 Cr 15.83 No 2.51 S

.004 C

.04 l

l I

i i

r 7

.; 7 4

Pagt 52 of 82 ENCLOSURE 2 FASTENER TESTING DATA _(SHEET NO, 1)

^'

108 VY-87-02-26NNS-F Fastener

Description:

5/8"-11 x 1\\" SS Bolts Description of Sample Stock Location:

1 Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by.ti,censee Records:

Class / Procurement Level:

.NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

Sigr,at ure h6,6 O

..h Date NF

  • Identification as GM 455-M is assumed or by physical inspection. Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

l

-,__y

r.

Paga 52 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 108 VY-87-02-26-NNS-F MECHANICAL ANALYSIS HARCNESS UTS 0.2% YS HRC 34.5 N/A N/A CHEMICAL ANALYSIS E

I E

I E

I FE REM P

.025 Si

.34 Mn 1.29 Ni 12.15 Cr 18.32 S

.020 C

.04

Pag? 53 of 82 i

ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-27-NNS-F Fastener

Description:

1/2"-13 x 2" SS Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N452.2 Quality Level B Material Specification as Documented by Licensee Records:

None Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

1 None Licensee Representative:

((M Signature hem,)

MMt Date

  • !dentification as ASTM A193 is assumed or by physical inspection. Material was purchased NNS and, therefore, the vendor was rot required to meet any stated specification.

Pcga 54 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

J_0* VY-87-02-27-NNS-F 0

MECHANICAL ANALYSIS HARONESS UTS 0.2% YS HRC 24.5 N/A N/A CHEMICAL ANALYSIS E_(

)

gk I

{.(

}

FE REM P

.028 Si

.54 Mn 1.54 Ni 15.00 Cr 15.70 i

Mo 2.62 9

.007 C

.04 i

a i

Pag? 55 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ION VY-87-02-28-NNS-F Fastener

Description:

3/8-16 x 3/4" SS Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

316 Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor-Not Identified QA Requirements Impased on Vendor:

None Licensee Representative:

8, h M/

Date

/N 8 Signature

eug, i
  • Identification as ASTM A193 is assumed or by physical inspection.

Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

r Page 56 of 82 ENCLOSURE 2 DATA SUMMAF.Y (SHEET l10, 2) 10# VY-87-02-28-NNS-F t

MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 36.0 N/A N/A CHEMICAL ANALYSIS E(

3 E_(

}

E_(

3 FE REM P

.031 Si

.60 Mn 1.00 Ni 11.31 Cr 16.82 Mo 2.06 S

.005 C

.05 i

I

r Paga 57 of 82 ENCLOSURE 2 FASTENER TESTING OATA (SHEET NO. 1)

ID# VY-87-02-29-NNS-F Fastener

Description:

3/8"-24 x 1%" CS Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

None Class / Procurement Level:

NHS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

/,/a/Js Signature Ogu,2 O. Ma Date

  • Identification as SAE J429 is assumed or by physical inspection.

Material was I

purchased NNS and, therefore, the vendor was not required to meet any stated specification.

L

Page 58 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02 N,45-F MECHANICAL ANAf.YSIG HARDNESS UTS 0.2% YS HRC 40.0 N/A N/A CHEMICAL ANALYSI_S EL EL 3

EL 1

FE REM P

.017 Si

.27 Mn

.82 Cr

.16 Mo

.22 S

.011 C

.36

Page 59 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-30-NNS-F Fastener

Description:

7/16"-14 x 34" CS Plated Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

Rockford

'\\ /

l Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

A Date sk//88 Signature _

19 kgy, 0. NccN

  • Identification as SAE J429 Class 5 is assumed or by physical inspection.

E Mateeial was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

l

T Paga 60 of 82 CNCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 108 VY-87-0?-30-NNS-F' MECHANICAL ANALYSIS HARONESS UTS 0.2% YS HRC 29.0 N/A N/A t

I l

CHEMICAL ANALYSIS

!~

El

)

El

)

fl

)

FE REM P

.013 Si

.20

]

Mn

.86 Cr

.02 Mo

.02 S

.023 C

.39 i

l Pago 61 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET ND, 1)

ID# VY-87-02-31-NNS-F Fastener

Description:

1/4"-20 x 4" CS Plated Bolt Description of Sample Stock Location:

Utdlity Stockroom in accordance With ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

\\

Rockford l

Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts l

Vendor:

l Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

Signature

%$ O, et/d Date, //v!B8' -

1 l

l

  • Ider.tification as SAE J429 is assumed or by physical inspection. Material was l

purchased NNS and, therefore, the vendor was not required to meet any stated I

specification.

l l

l r-Pago 62 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-31-NNS-F MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 33.5 N/A N/A CHEMICAL ANALYSIS E

I E

3 E

3 FE REM P

.019 Si

.19 Mn

.99 Cr

.12 Mo

.01 S

.017 C

.37

Page 63 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-32-NNS-N Fastener

Description:

5/8-11 SS-18-8 Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

None Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Idenfified QA Requirements Imposed on Vendor:

None Licensos Nepresentative:

/,/a/b 8 Signature

/ h[

O. M gEt, Date

  • Identification as ASTM A194 is assumed or by physical inspection. Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

l

Page 64 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

IO# VY-87-02-32-NNS-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 26.0 N/A N/A CHEMICAL ANALYSIS E

I E

I E

1 FE REM P

.032 Si

.34 Mn 1.19 Ni 10.22 Cr 18.04 Mo

.15 S

.008 C

.03

s Page 65 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-33-NNS-N Fastener

Description:

5/8"-18 CS Nuts Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N452.2 Quality Level B Material Specification as Documented by Licensee Records:

None Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts l

Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

Signature

/ cul R

II sci Date

/////b 6'

  • Identification as SAE J995 is assumed or by physical inspection. Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

I t

r Page 66 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ID# VY-87-02-33-NNS-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 97.0 N/A N/A CHEMICAL ANALYSIS E_(

3 EL 1(

)

FE REM P

.009 Si

.13 Mn

.49 Ni

.03 Cr

<.01 Mo

.01 S

.013 C

.05

Pago 67 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 67)

ID# VY-87-02-34-NNS-N Fastener

Description:

3/4"-10 CS Nuts Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

None Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Impesed on Vendor:

None Li:ensee Representative:

Signature _

en,yb

0. bo i

Date

/////36

  • Identification as SAE J995 is assumed or by physical inspection.

Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

F-Page 68 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ID# VY-87-02-34-NNS-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 78.0 N/A N/A CHEMICAL ANALYSI)

El 3

EL 3

JL FE REM P

.023 Si

.04 Mn

.42 Cr

<.01 Mo

.01 S

.028 C

.17

f-Page 69 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-35-NNS-N Fastener

Description:

3/4'-10 SS Nuts Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

None Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

/,//<[36 Signature 62,N O.

rA< <lt Date

  • Identification as ASTM A194 is assumed or by physical inspectior:. Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

r-Page 70 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-35-NNS-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 27.0 N/A N/A CHEMICAL ANALYSIS E_1

}

El 3

E.1 3

FE REM P

.034 Si

.45 Mn 1.06 Ni 9.19 Cr 18.01 S

.009 C

.04

Page 71 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

=

10# VY-87-02-36-NNS-N

[

Fastener

Description:

1/2"-13 SS Nuts Description of Sample Stock Location-Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

None Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

Signature hC/hto b.

U * <-i Date

/////# 6

  • Identification as ASTM A194 is assumed or by physical inspection. Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

Pag 2 72 of 82 ENCLOSURE 2 DATA

SUMMARY

-(SHEET NO. 2) 10# VY-87-02-36-NNS-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 26.5 N/A N/A CHEMICAL ANALYSIS EL 3

{k

}

g.L

}

FE REM P

.029 Si

.50 Mn 1.13 Ni 9.05 Cr 18.23 Mo

.24 S

.005 C

.04

Page 73 of @2 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-37-NNS-N Fastener

Description:

1/4"-20 CS - Plated Nuts Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

  • General - Commercial Grade Head Marking (Specification and Manufacturer)r None Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

\\

None Licensee Representative:

mf,[,

8, 8thard Date d///5'8 Signature o

  • Identification as SAE J995 is assumed or by physical inspection. Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

Page 74 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

ID# VY-87-02-37-NNS-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 91.5 N/A N/A CHEMICAL ANALYSIS E_L_

3 fl E.1 3

FE REM P

.025 Si

.05 Mn

.33 Cr

.01 Mo

.01 S

.014 C

.11

1 Page 75 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-38-NNS-N Fastener

Description:

3/8"-16 CS Plated Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

s

(

)

v Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

Signature Cnud d.

pk Date__4a/re

/

  • Identification as SAE J995 is assumed or by physical inspection. Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

Page 76 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-38-NNS-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 24.0 N/A N/A CHEMICAL ANALYSIS E

E I

E I

FE REM P

.008 Si

.24 Mn

.80 Cr

.07 Mo

.02 S

.015 C

.33 l

l

{-

Pags 77 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1) 10# VY-87-02-39-NNS-N Fastener Desetiption:

3/8"-16 CS Plated Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

None Class / Procurement Level:

None General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

Signature

/hCnge_).

O.

dIu i Date q//</gE

  • Identification as SAE J995 is assumed or by physical inspection. Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

Pege 78 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-39-NNS-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 93.0 N/A N/A CHEMICAL ANALYSIS kk It Ek I

Ek I

FE REM P

.011 Si

.05 Mn

.33 Cr

.01 Mo

.01 S

.027 C

.12 l

5 Poge 79 of 82

/,

ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

IO# VY-67-02-40-NNS-N Fastener

Description:

7/16"-14 CS Plated Nuts Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

(

Class / Procurement Level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Ieposed on Vendor:

None Licensee Representative:

Signature e g E b. d f vc2

/,////tB Date

  • Identification as SAE J995 is assumed or by physical inspection.

Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

=

s

-r Page 80 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2)

\\

ID# VY-87-02-40-NNS-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRC 74.5 N/A N/A CHEMICAL ANALYSIS E_L.,

ft EL

.)

FE REM P

.010 Si

.13 Mn

.43 Cr

.02 Mo

.01 S

.014 C

.17 I

i i

i

n- -

Page 81 of 82 ENCLOSURE 2 FASTENER TESTING DATA (SHEET NO. 1)

ID# VY-87-02-41-NNS-N Fastener

Description:

7/8"-9 CS Plated Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level B Material Specification as Documented by Licensee Records:

None

' Class / Procurement level:

NNS General Plant Application (e.g., Pressure Boundary, Structural)

Stock Parts Vendor:

Not Identified QA Requirements Imposed on Vendor:

None Licensee Representative:

Signature Md M i

Date NW

  • Identification as SAE J995 is assumed or by physical inspection.

Material was purchased NNS and, therefore, the vendor was not required to meet any stated specification.

Paga 82 of 82 ENCLOSURE 2 DATA

SUMMARY

(SHEET NO. 2) 10# VY-87-02-41-NN3-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 82.0 N/A N/A CHEMICAL ANALYSIS

_E(

3 E.L._

3 E_(

)

FE REM P

.005 Si

.04 Mn

.34 Cr

.03 Mo

.01 S

.014 C

.05

Page 1 of 14 ENCLOSURE 3 FASTENER TESTING DATA (SHEET 1 of 2)

ID# VY-87-02-42SR-N*

Fastener

Description:

5/8"-11 CS PlLted Bolt Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level "B"

Material Specification as Documented by Licensee Records:

ASTM A194 Grade 1 Head Marking (Specification and Manufacturer):

2T Class /Procurenent Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Main Steam Isolation Valve Vendor:

Rockwell QA Requirements Imposed on Vendor:

C of C Licensee Representative:

8x$7 f Mugd Date

//d*#

Signature

/

i

  • This item from the same lot as #VY-87-02-13SR-N t

Page 2 of 14 ENCLOSURE 3 DATA

SUMMARY

(SHEET 2 of 2)

ID# VY-87-02-42SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% Y,e HRB 89.0 N/A N/A CHEMICAL ANALYSIS E_(

)

{(

)

g,(

)

1 FE REM P

.018 Si

.28 Mn

.72 Cr

.06 Mo

.01 S

.012 C

.40 PROOF TESTIN0 Area Applied Lbs.

Results

.223 30510 No Stripping l

l

Pag 2 3 of 14 ENCLOSURE 3 FASTENER TESTING DATA (SHEET 1 of 2)

ID# VY-87-02-43SR-N*

Fastener

Description:

5/8"-11 CS Plated Bolt Description of Sample Stock location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level "B" Material Specification as Documented by Lictnsee Records:

ASTM A194 Grade 1 Head Marking (Specification and Mar,ufacturer):

2T Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Main Steam Isolation Valve Vendor:

Rockwell QA Requirements Imposed on Vendor:

C of C Licensee Representative:

Signature

/ g O. Jethde

/,/a4*#

Date

  • This item from the same lot as #VY-87-02-13SR-N.

Paga 4 of 14 ENCLOSURE 3 DATA

SUMMARY

(SHEET 2 of 2)

ID# VY-87-02-43SR-N HECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 89.0 N/A N/A CHEMICAL ANALYSIS Ek 3

E,L, g(

3 FE REM P

.022 Si

.25 Mn

.69 Cr

.03 Mo

.01 S

.013 C

.40 PROOF TESTING Area Applied Lbs.

Results

.226 30510 No Stripping

Page 5 of 14 ENCLOSURE 3 FASTENER TESTING DATA (SHEET 1 of 2)

ID# VY-87-02-44SR-N*

Fastener

Description:

l 5/16"-18 SS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level "B" Material Specification as Documented by Licensee Records:

ASTM A194 Grade 8 Head Marking (Specification and Manufacturer):

B8 Class / Procurement Level Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

Hardware Specialty Co., Inc.

QA Requirements Imposed on Vendor:

C of C Licensee Representative:

Signature cum O. Mr / cst Date _//// ff AThis item from the same lot as #VY-87-02-18SR-N.

Page 6 of 14 ENCLOSURE 3 DATA

SUMMARY

(SHEET 2 of 2)

ID# VY-87-02-44SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 101.5 N/A N/A CHEMICAL ANALYSIS E

I E

51 FE REM P

.023 Si

.28 Cu 3.09 Mn

.52 Ni 8.19 Cr 17.52 S

.002 C

.03 PROOF TESTING Area Applied Lbs.

Results

.0524 3930 No Stripping 4

1

D P ge 7 of 14 ENCLOSURE 3 FASTENER TESTING DATA (SHEET 1 of 2) 10# VY-87-02-45SR-N*

Fastener

Description:

5/16"-18 SS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level "B" Material Specification as Documented by Licensee Records:

ASTM A194 Grade 8 Head Marking (Specification and Manufacturer):

B8 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural) l Spares Vendor j

Hardware Specialty Co., Inc.

QA Requirements Imposed on Vendor:

l C of C Licensee Representative:

i 4

Signature Os-ird 8. Mr$ch Date

////b8 e

I

  • This item from the same lot as #VY-87-02-18SR-N.

l 5

Y l

Paga 0 of 14 ENCLOSURE 3 DATA

SUMMARY

(SHEET 2 of 2) 10# VY-87-02-45SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 102.0 N/A N/A CHEMICAL ANALYSIS E

I E

3 E

I FE REM P

.021 Si

.28 Cu 3.06 Mn

.32 Ni 8.22 Cr 17.48 S

.002 C

.03 PROOF TESTING Area Applied Lbs.

Results

.0524 3930 No Stripping i

t

Paga 9'of 14 ENCLOSURE 3 FASTENER TESTING DATA (SHEET 1 of 2)

ID# VY-87-02-46SR-N*

Fastener

Description:

S/16"-18 SS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level "B" Material Specification as Documented by Licensee Records:

ASTM A194 Grade 8 Head Marking (Specification and Manufacturer):

B8 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

Hardware Specialty Co., Inc.

QA Requirements Imposed on Vendor:

C of C

'icensee Representative:

nmh 6. dl[fft Date q///MP Signature e

  • This item from the same lot as #VY-87-02-18SR-N.

Page 20 of 14 ENCLOSURE 3 DATA SUMN'9Y (SHEET 2 of 2) 10# VY-87-02-46SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 102.5 N/A N/A CHEMICAL ANALYSIS El 3

El 3

g 3

FE REM P

.023 Si

.28 Cu 3.07 Mn

.52 Ni 8.24 Cr 17.46 S

.002 C

.03 PROOF TESTING Area Applied Lbs.

Results

.0524 3930 No Stripping

P;g) 11 Cf 14 ENCLOSURE 3 FASTENER TESTING DATA (SHEET 1 of 2) 108 VY-87-02-47SR-N*

Fastener

Description:

S/16"-18 SS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level "B"

Material Specification as Documented by Licensee Records:

ASTM A194 Grade 8 Head Marking (Specification and Manufacturer):

B8 Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

Hardware Specialty Co., Inc.

QA Requirements Imposed on Vendor:

C of C Licensee Representative:

0 N c b c> h Date

/b/b"U Signature

/ tu.a,

  • This item from the same lot as #VY-87-02-18SR-N.

Paga 12 of 14 ENCLOSURE 3 DATA

SUMMARY

(SHEET 2 of 2)

ID# VY-87-02-47SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 102.0 N/A N/A CHEMICAL ANALYSIS E

I E

I E

I FE REM P

.024 Si

.26 Cu 3.08 Mn.

.52 Ni 8.24 Cr 17.44 S

.002 C

.03 PROOF TESTING Area Applied Lbs.

Results

.0524 3930 No Stripping

-1 Pag) 13 of'14

)

ENCLOSURE 3 FASTENER TESTING DATA (SHEET 1 of 2)

IDS VY-87-02-48SR-N*

Fastener

Description:

5/16"-18 SS Nut Description of Sample Stock Location:

Utility Stockroom in accordance with ANSI N45.2.2 Quality Level "B" Material Specification as Documented by Licensee Records:

ASTM A194 Grade 8 Head Marking (Specification and Manufacturer):

B8 Class / Procurement Level Safety Related oeneral Plant Application (e.g., Pressure Boundary, Structural)

Spares Vendor:

Hardware Specialty Co., Inc.

QA Requirements Imposed on Vendor:

C of C Licensee Representative:

Signature ex,u; 0. b sjet Date

//n/bh

  • This item from the same lot as #VY-87-02-18SR-N.

a m

(

Page 14 of 14' ENCLOSURE 3 DATA

SUMMARY

(SHEET 2 of 2) 108 VY-87-02-48SR-N MECHANICAL ANALYSIS HARDNESS UTS 0.2% YS HRB 102.0 N/A N/A CHEMICAL ANALYSIS E

I E

I E

I FE REM P

.024 Si

.28 Cu 3.08 Mn

.52 Ni 8.17 Cr 17.43 S

.002 C

.03 PROOF TESTING Area Applied Lbs.

Results

.0524 3930 No Stripping l

t