LOUISIANA P O W E R & L i G H T! WATERFORD 3 SES

  • PO. BOX B e KILLONA LA '/00660751

$iu $ drsNU June 23, 1988 W3A88-0065 A4.05 NQA U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C.

20555

SUBJECT:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Main Steam Isolation Valve Louisiana Power & Light Company has completed our final report on the Main Steam Isolation Valve Cuide Rail failure.

Our evaluation concludes that the valve remained operable even with the guide rails missing.

Due to the generic applications of similar type valves throughout the industry and to provide the commission with the detailed information on the failure, we are forwarding a copy of the June 20, 1988 report.

N.S. Carns Plant Manager-Nuclear CRG/NSC/kal Enclosure cc:

R.D. Martin, D.L. Wigginton, NRC Resident Inspectors Office a

l 'i i

)

6280169 880623 p

ADOCK osoooggy DCD