l DG 5/18 N 2 6 fggg W. John Arthur, III, Project Manager Uranium Mill Tailings Project Office Department of Energy Albuquerque Operations Office P.O. Box 5400 1

albuquerque, New Mexico 87115

Dear Mr. Arthur:

We have completed our acceptance review of the Draft Remedial Action Plan (dRAP) and The Draft Environmental Assessment for the Belfield and Bowman, North Dakota UMTRAP sites. As discussed in a May 16, 1988 telecon between Dan Gillen of my staff and Frank Bosiljevac of your staff, the documents are sufficiently complete for us to begin our review. However, the following information and data are needed to enable completion of the groundwater hydrology portion of the review:

1.

dRAP, p. 163 and 170. Details of monitoring well and lysimeter construction and installation at Belfield and Bowman.

2.

dRAP, p. 165 and 172. Analysis of slug / pump test data conducted in monitoring wells at Belfield and Bowman to determine hydraulic conductivity.

3.

dRAP, p. 178.

Input and output from the Domenico and Robbins model used at Bowman to predict downgradient concentrations.

4.

DEA, p. C-64 Report prepared by Roman V. Pyrih of Geochemical Engineering entitled, "Geochemical Properties of Soil Samples from Lignite Processing Site, Bowman, North Dakota, Report on Lauoratory Analysis. "

In addition, we have noted the absence of the following information that, although not essential at this stage of the review, should be provided as early.

as possible to avoid major open issues late in the review process:

1.

Geotechnical engineering calculations for slope stability, settlement, liquefaction potential, filter and bedding' materials, and radon barrier thickness.

2.

Groundwater compliance information:

Proposed concentration limits (i.e., MCLs or ACLs) for hazardous constituents in the uppermost aquifer at Bowman, and supporting analysis and justification if ACLs are proposed.

)

Point of compliance at Bowman, blm '14-8806280067 880526

(@q-Y T_74 oco gt.$

j

W 26 m e

Y DG 5/18

- Conceptual aquif, restoration plan for Bowman, or demonstration that disposal ano restoration at the Bowman site can be separated.

If you have any questions regarding this review, please. contact Dan Gillen of mystaff(FTS 492-0517).

Sincerely, IS Paul H. Lohaus,' Chief Operations Branch Division of Low. Level Waste Management and Decommissioning cc: Frank Bosiljevac, 00E/Alb.

Debbie Mann, DOE /Alb.

DISTJ118UT10N:

Je6tralFile HMSS r/f LLOB r/f DGillen, LLOB MFliegel, LLOB PLohaus, LLOB JSurmeier, LLTB MBell, LLRB JGreeves, LLWM MKnapp, LLWM RBangart, LLWM R.D. Smith, URF0 MTokar, LLTB JStarmer, LLTB L0eering, LLTB JKane, LLTB

/M no 0

1 1

NAME:0Gi42n{[g: M

LL0bhfp /

0FC: LLO

LLOB q..g(N.............................

]

/dfw :MFliegel

PLohaus

.......................,.c...........[.......................................

/D88 DATE: f/4/88

-[/f3/88 OFFICIAL RECORD COPY i