ML20195E820

From kanterella
Jump to navigation Jump to search
Errata to Cooper Nuclear Station Semiannual Operating Rept, Radioactive Effluents Jan-June 1984
ML20195E820
Person / Time
Site: Cooper Entergy icon.png
Issue date: 04/30/1986
From:
NEBRASKA PUBLIC POWER DISTRICT
To:
Shared Package
ML20195E802 List:
References
NUDOCS 8606090237
Download: ML20195E820 (2)


Text

-

NEBRASKA PUBLIC POWER DISTRICT COOPER NUCLEAR STATION SEMI-ANNUAL OPERATING REPORT RADIOACTIVE EFFLUENTS l

DOCKET NUMBER 50-298 January 1,1984 through June 30,1984 ERRATA May 21,1986 8886 Z88E 808! L a

enn

l Table 2A.

Effluent and Naste Disposal Report Liquid Effluents - Summation of All Releases Est. Total Unit 1st Ouarter 2nd Ouarter Error %

Fission & activation cases l

1. Total release (not I

including tritium, C1 11.60 E+00 11.14 E+00 2.0 E+01 i

gases, and alpha)

2. Average dilution con-centration during j

period pCi/ml 11.19 E-07 14.85 E-08 j

3. Percent of applicable limit 6.40 E+00 4.56 E+00 Tritium
1. Total release C1 12.40 E+00 11.91 E+00 2.0 E+01
2. Average diluted con-centration during period 4 pCi/ml 11.79 E-07 18.27 E-08
3. Percent of applicable limit 5.97 E-03 2.76 E-03 Dinsolved and entrained cases
1. Total release C1
  • 18.61 E-03 11.12 E-02 5.0 E+01
2. Average diluted con-centration during period PCi/ml 16.43 E-10' 14.85 E-10
3. Percent of applicable limit Gross alpha radioactivity
1. Total release C1 11.42 E-03 12.23 E-02 5.0 E+01 Volume of waste released (prior to dilution) liters 2.38 E+06 3.41 E+06 1.0 E+01 Volume of dilution water uccd during period liters 1.34 E+10 2.31 E+10 1.0 E+01 Not applicable.

f 1

A8

'