Amends 204 & 234 to Licenses DPR-71 & DPR-62,respectively, Revising TS 5.2.2.f Re SRO Licensing Requirement for Operations Manager
ML20195C370
Person / Time
Site: Brunswick  Duke Energy icon.png
Issue date: 11/04/1998
From: Hebdon F
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20195C376 List:
References
NUDOCS 9811170094
Download: ML20195C370 (8)


Text

_ _

r putoo

[

k UNITED STATES l

g j

NUCLEAR REGULATORY COMMISSION l

o WASHINGTON, D.C. 20666-0001 i

<Q*****

CAROLINA POWER & LIGHT COMPANY. et al.

DOCKET NO. 50-325 SRUNSWICK STEAM ELECTRIC PLANT. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE l

Amendment No. 204 License No. DPR-71 1.

The Nuclear Regulatory Commission (the Commission) has found that:

i A.

The application for amendment filed by Carolina Power & Light Company (the licensee), dated August 17,1998, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the l

Act, and the rules and regulations of the Commission; l

l C.

There is reasonable assurance (l) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the l

Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the l

Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications, as indicated in the attachment to this license amendment; and the first paragraph of 2.C.(2) of Facility Operating License No. DPR-71 is hereby amended to read as follows:

9811170094 981104 PDR ADOCK 05000324 P

PDR I

I i

2-(2)

Technical Soe'ificationt c

The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 204, are hereby incorporated in the license. Carolina Power & Light Company shall operate the facility in accordance with the

)

Technical Specifications.

l 3.

This license amendment is effective as of the date of its issuancs and shall be l

implemented within 30 days of issuance.

l FOR THE NUCLEAR REGULATORY COMMISSION k(

A( tWM) l 1)I c-Frederick J. Hebdo, Director Project Directorate ll-3 Division of Reactor Projects - 1/il Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of issuance:

November 4,1998 i

4 1

ATTACHMENT TO LICENSE AMENDMENT NO. pna FACILITY OPERATING LICENSE NO. DPR-71 i

DOCKET NO. 50-325 Replace the following page of the Appendix A Technical Specifications with the enclosed page.

i The revised areas are indicated by marginal lines.

Remove oaag insert Paae 5.0-3 5.0-3 1

1

Organization 5.2 5.2 Organization 5.2.2 Facility Staff (continued) b.

At least one licensed Reactor Operator (RO) shall be present in the control room when fuel is in the reactor.

In addition, when either unit is in MODE 1, 2, or 3, at least one licensed Senior Reactor Operator (SRO) shall be present in the control room. With one unit in MODE 1, 2, or 3 and the other unit defueled, the minimum shift crew shall include a total of two SR0s and two R0s.

c.

Shift crew composition may be less than the minimum requirement of 10 CFR 50.54(m)(2)(i) and Specifications 5.2.2.a and 5.2.2.g for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the shift crew composition to within the minimum requirements.

d.

An individual qualified in radiation protection procedures shall be on site when fuel is in the reactor.

The position may be vacant for not more than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, in order to provide for unexpected absence, provided immediate action is taken to fill the required position.

Administrative procedures shall be developed and implemented e.

to limit the working hours of facility staff who perform safety related functions (e.g., licensed SR0s, licensed R0s, health physicists, auxiliary operators, nd key maintenance i

personnel). These procedures shall meet the working hour guidelines published by the Nuclear Regulatory Commission in Generic Letter 82-12.

f.

The operations manager or assistant operations manager shall hold an SR0 license.

g.

The shift technical advisor shall serve in an advisory capacity to the shift superintendent on matters pertaining to the engineering aspects assuring safe operation of the unit when either unit is in MODE 1, 2, or 3.

Brunswick Unit 1 5.0- 3 Amendment No.204 l

49' Op aar%+,

i g

UNITED STATES g

j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 206aH001

$4*****

,o CAR LINA POWER & LIGHT COMPANY. et al.

DOCKET NO. 50-324 BRUNSWICK STEAM ELECTRIC PLANT. UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 234 License No. DPR-62 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment filed by Carolina Power & Light Company (the licensee), dated August 17,1998, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment; and the first paragraph of 2.C.(2) of Facility Operating License No. DPR-62 is hereby amended to read as follows:

s I

i i

. (2)

Technical Soe'cifications The Technical Specifications contained in Appendices A and B, sa revised through Amendment No. 234, are hereby incorporated in the license. Carolina Power & Light Company shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance and shall be implemented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION c'

.f Frederick J. Hebdo, Director Project Directorate 11-3 Division of Reactor Projects -l/ll Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: November 4,1998 l

i s

- - -. ~..

-. = -.

ATTACHMENT TO LICENSE AMENDMENT NO. 234 FACILITY OPERATING LICENSE NO. DPR-62 DOCKET NO. 50-324 Replace the following page of the Appendix A Technical Specifications with the enclosed page.

The revised areas are indicated by marginallines.

Remove naoe Insert Paoe 5.0-3 5.0-3 l

r l

Organization 5.2 5.2 Organization 5.2.2 Facility Staff (continued) b.

At least one licensed Reactor Operator (RO) shall be present in the control room when fuel is in the reactor.

In addition, when either unit is in MODE 1, 2, or 3, at least one licensed Senior Reactor Operator (SRO) shall be present in the control room. With one unit in MODE 1, 2, or 3 and the other unit defueled, the minimum shift crew shall include a total of two SR0s and two R0s.

c.

Shift crew composition may be less than the minimum requirement of 10 CFR 50.54(m)(2)(1) and Specifications 5.2.2.a and 5.2.2.g for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate ~ unexpected absence of on-duty shift crew members provided imediate action is taken to restore the shift crew composition to within the minimum requirements, d.

6 individual qualified in radiation protection procedures stia11 be on site when fuel is in the reactor. The position may be vacant for not more than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, in order to provide for unexpected absence, provided immediate action is taken to fill the required position.

e.

Administrative procedures shall be developed and implemented to limit the working hours of facility staff who perform safety related functions (e.g., licensed SR0s, licensed R0s, health physicists, auxiliary operators, and key maintenance personnel). These procedures shall meet the working hour guidelines published by the Nuclear Regulatory Commission in Generic Letter 82-12.

f.

The operations manager or assistant operations manager shall hold an SRO license.

g.

The shift technical advisor shall serve in an advisory capacity to the shift superintendent on matters pertaining to the engineering aspects assuring safe operation of the unit when either unit is in MODE 1, 2, or 3.

l Brunswick Unit 2 5.0- 3 Amendment No.2341

-