0 NOTICE OF VIOLATION Toledo Edison Company Docket No. 50-346 As a result of the inspection conducted on February 17, 1986, through May 9, 1986, and in accordance with the " General Policy and Procedures for NRC Enforcement Actions," 10 CFR Part 2, Appendix C (1985), the following violation was identified:
Technical Specification Surveillance Requirement 4.7.1.2c requires that the Auxiliary Feed Pump Turbine (AFPT) Steam Generator (SG) Level Control System be demonstrated operable by the performance of a channel functional check on a monthly basis in modes 1, 2, and 3.
Contrary to the above, from July 24, 1977, when the unit first entered mode 3, until June 9, 1985, the AFPT SG Level Control System was not demonstrated operable in that ST 5071.04, " Auxiliary Feedwater System Channel Functional Test," did not test the AFPT SG Level Control System with steam generator level both above and below the level setpoint on a monthly basis as required by the surveillance requirement.
This is a Severity -Level IV violation (Supplement I).
[
t i
Date tarl J. Paperiello, Director Division of Reactor Safety