ML20155J186

From kanterella
Jump to navigation Jump to search
Advises That Rev 10 to Radiological Emergency Response Plan Consistent W/Provisions of 10CFR50.47(b) & App E to 10CFR50 & Acceptable
ML20155J186
Person / Time
Site: Farley  Southern Nuclear icon.png
Issue date: 05/09/1986
From: Verrelli D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Mcdonald R
ALABAMA POWER CO.
References
NUDOCS 8605220074
Download: ML20155J186 (1)


Text

o f #c, a /

Alabamja Power Company ATTN: VMr. R. P. Mcdonald Senior Vice President P. O. Box 2641 Birmingham, AL 35291 Gentlemen:

SUBJECT:

FARLEY NUCLEAR PLANT RADIOLOGICAL EMERGENCY PLAN REVIEW DOCKET NOS. 50-348 AND 50-364 We have completed our review of Revision 10 of the Farley Radiological Emergency Plan.

Our review indicated the changes that were submitted for your Farley Radiological Emergency Response Plan meet the planning standards of 10 CFR 50.47(b) and the requirements of Appendix E to 10 CFR 50.

Please be reminded that 10 CFR 50.54(q) requires NRC approval of any changes to your plan which may decrease the effectiveness of the Plan.

However, if your safety review indicates no decrease in the level of emergency preparedness, then changes may be made without NRC approval.

In all cases, you should furnish copies of each change to the NRC in accordance with 10 CFR 50.54(q). Also, any changes to the Emergency Plan Implementing Procedures should be made in accordance with the requirements of 10 CFR 50, Appendix E, Section V.

Should you have any questions regarding this letter, please contact Mr. Thomas R.

Decker of our staff at 404/331-2600.

Sincerely, David M. Verrelli, Chief Reactor Projects Branch 2 Division of Reactor Projects I.O.Whitt, Executive cc:

/ Vice President

/J. D. Woodard, General Manager -

Nuclear Plant d(. G. Hairston, III, General Manager - Nuclear Support

/ W. McGowan, Manager-Safety Audit and Engineering Review tW". G. Ware, Supervisor-Safety Audit and Engineering Review bcc:

Reeves, Project Manager, NRR A ccument Control Desk vtfRC Resident Inspector v5ftate of Alabama RII RII R

RII DCollins HDance TD er

/[6 1/p /86 6/p /86 If1 /86 8605220074 860509 DR ADOCK 0000 0

7 gy