Text
_ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _
p b Form 374-- -- --- -- - - -- - --- - - ---Tumrs'admETTmmrF2PETRTatssm Terg's-
l NR
1
3
PAGE
OF
PAGES
(F 83)
U.S. NUCLEAR REGULATORY COMMISSION
g
{
l
Amendment No. 17
MATERIALS LICENSE
,
l ~ Pursuant to'the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93 -438),
g
Code of* Federal Regulations, Chapter I, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations
l,
g
heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct,
p
l
source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below; to )
I
deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This
I
%
l license shall be deemed to contain the conditions specified in Section 183 of the
subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any
!
'
y
conditions specified below.
p
E
Ucensee
i
In accordance with letter
!
3
dated September 25, 1987
l
l
1.
State of Alaska
3. License number 50-14102-01 is amended in
i
g
Dept. of Transportation & Public Fac.
its entirety to read as follows:p'
.
!
s
Headquarters Meterials
_
l
g
2.
P. O. Box 196900
~,
n- .'
8
Anchorage, Alaska 99519-6900
'
4. Espiration date April 30, 1991
i
.
q
q
5. Docket or
-
!
l
.'
Reference No.
030-07710
7. Chemical and/or physical
( 8. Maximum amount that licensee
k
1
6. Byproduct, source, and/or
N
I
N
fann
imay possess at any one time
E
!" ,
~
' under this license
i
A.
' Sealed sources
f
A.
,Not to exceed
l
[I
'
I
A.
l
'(Trox)er: Dwge A-102112):
i >10 millic; ries
-
g
y
,
.
(,per source
g
-
I
. _.
i. !
k
.
-
i
B.
1-
-B.
Sealed' neutron sources'-.
B.
- Not to exceed
y
l
(..
(Troxler Owg.cA-102451) .
',
- 50 millicuries
@
~ }T 7
' j. ;
.(
E
3 per source
j
s
g
,
E
i
g
C.
i- 1
C.; i Sealdd 'netdron sou'rcos i
Ci
Not to exceed
-
%g-
+L
-(Troxler'Dwg.-No.
..
330 millicuries
i
,
I
A-100337,.RevisionB)
s
per source
y
1
.
j >
'
.;.
y
'
D.
Not to exceed
(
l
/ .
Sealed source's
~#
0.
D
t -
q
(Campbell Pacific Nucleari
10 millicuries
$g
-
i
Model CPN-131),
per source
jlk
'
1
.
E.
Not to exceed
<
E
I
E.
E.
Scaled neutron sources
I
50 millicuries
l
Model CPN-131)
per source
!g
E
i
g
F.
F.
Sealed neutron sources
F.
Not to exceed
4
I
50 millicuries
,
,
ModelCPN-131)
per source
,,
i.
G.
G.
Sealed sources
G.
Not to exceed
l
Humboldt Scientific, Inc.
11 millicuries
!
Dwg. No. 220064
per sourcc
lgl
f
H.
H.
Sealed sources
H.
Not to exceed
y
Humboldt Scientific, Inc.
44 millicuries
A(
l
Dwg. No. 220067
per source
,
y
-)
!g
y
8806200218 871015
ll{(J
g
REGS LIC30
t/
'y
l (
j
50-14102-01
g
MXCMermsweriM&wrmmmerzxwthymm. metr +wwww.dritd
- _ _ _ _ _ _ _ _ _
,
p---.--------------------------------=----------m==--=9
I
q
CC Form 374A
U.S. NUCLEAR RE!ULATORY COMMISSION
PAGE
OF
TAGES
l
- $."14Y02-01
!
MATERIALS LICENSE
I
g
-
pocket or aererence number
l
SUPPLEMENTARY SHEET
030-07710
i
>
l
.
l
l
Amendment No. 17
y
b
q
9.
Authorized use
i
I
i
I
A.
For use in Troxler Model 4545 or Model 4640 to measure properties of materials.
I
F
l A. and B. For use in Troxler Model 3400 Series Moisture-Density gauges to measure
y
q
properties of construction materials.
.g
i
i
i
C.
For use in Troxler Model 2226 or 3241 gauges to measure asphalt content of
I
l
construction materials.
[
l D and E. For use in Campbell Pacific Nuclear!Model HC Series gauges to measure
f
4
properties of construction: materials.1 - ! ?
g
f
i
4
.
e ..
e
4
F.
For use in Campbell Pacific Nuclear Model AC-2 gauges'to measure properties of
>
j
construction materials.
-
,
l
l G. and H. For use in Humbol'dt: Scientific, Inc. Model 5001 series jauges to measure
f
propertiesofjonstructionmaterials.
.,
>
4
>
1
>
4
CONDITIONS,'
1 a
,
>
4
-
!
,
10. Licensed material'may be ased at 5700 East Tudo'r' Road, Anchorage, Alaska; 2301
l
l
g
Peger Road, Fairb'ank:..
4aska; Mile:7 Old Glacier Highway, Juneau, Alaska; and
y
E
at temporary job 'sitcs of the licensee anywhere'in the: United States where the
>
4
U. S. Nuclear Regulatory Connission maintains jurisdiction for? regulating the
>
'
j
use of licensed material.;
{
11.
Licensedmaterialshaklbeused-by,'or'underthesupervisionandinthephysical
l
l
~
q
presence of, Jerry S 4 Roach, Patrick H.. Harmon . James E. Wright, Ted C. Harwood,
p
4
Willard M. Knoppe, Jr., or, individuals whothave successfully completed the
>
/l
M,
training progran for gauge, users as specified in application dated March 5,
$
1986, and letters dated Apr.il 1,;1986 and April 2, 1987, and who have been
f
designated by the Radiation Protection Officer, Jerry S. Roach. The licensee
p
q
shall maintain records of individuals' designated as users.
p>
'
4
i 12. Sealed sources containing licensed material shall not be opened.
i>
>
l4
llg
13.
A.
The source (s) specified in Item (s) 7.A. through 7.C., 7.G., and 7.H., shall
be tested for leakage and/or contamination at intervals not to exceed
4l
q
6 months. Any source received from another person which is not accompanied
p
dj
by a certificate indicating that a test was performed within 6 months
>
4i
before the transfer shall not be put into use until tested.
>
4'
t
B.
The source (s) specified in Item (s) 7.D. through 7.F. shall be tested for
l
l
4
leakage and/or contamination at intervals not to exceed 1 year.
p
'
k'>
d
k
C.
Any source in storage and not being used need not be tested. When the
i
source is removed from storage for use or transfer to another person, it
%
l
shall be tested before use or transfer.
4
'>
4
!>R
i l
bl
dkwrxistrXWsmsary sxtymirK%zmrmsLwirrmmimrxistrxrmr_tists.r$
.
--
-
-
_ _ _ - _ _ _ _ _ _ _ _ _ _ _ _
-
-
,c.,,,s+-
m,o
,>,o;-
4; 'm---=-----=======mm===
-
WRC Form 374A
U.S. NLsCLEAR REGULATORY COMMISSION
DA9E
OF
PAGES_
l
N "1Nd2-01
MATERIALS LICENSE
q
-
3,,,,,,,y,,,,,,,,,3,,
1
SUPPLEMENTARY SHEET
030-07710
(
>
-
f
l
Amendment No. 17
4
I
q
[;
I
CONDITIONS
!?
q
I:
l (continued)
h
l
D.
The test shall be capable of detecting the presence of 0.005 microcurie of
g
radioactive material on the test sample.
If the test reveals the presence
N
i
of 0.005 microcurie or more of removable contamination, the source shall be
F
4
removed from service and decontaminated, repaired, or disposed of in
k
I
accordance with Comission regulations. A report shall be filed within 5
l
l
days of the date the leak test result is kn.own with the U. S. Nuclear
p-
g
Regulatory Comission, Region.V; Nuclear Materials Safety and Safeguards
t-
q
Branch; 1450 Maria Laneh Suite 210; Walnut Creek,. California 94596. The
F:
H
report shall specify.the source involved, the test results, and corrective
i
~
k
4
action taken.
Records of leak test results shall be kept in units of
l
microcuries and shall be maintained for inspection bj.the Comission.
(
Records may be , disposed of following Con nission inspection,
p
g
.
1
F:
<
4
E.
The licensee is authoriiedito collect leak test samples for analysis by
>:
4
Gulf Nuclear," Inc., Troxler Electronics Laboratories, Inc. , or tests for
>:
>
4
leakage and/or contamination.shall.be performed.by persons specifically
licensed by the Commission or an Agreement State to perform'such services.
[
l
J
,
_
d
P-
The licensee shall: conduct a physical inventory every.sixl(6) months to account
>:
g 14.
7
R
for all sources and/or devices received and possessed under th~elicense.
>-
4
Records of the inventories shall be maintained.for two (2) years from the date
f
l
of each inventory.
[
,
_,.
q
>:
q 150 The licensee may transp' ort licensed material 'in acc'ordance with the provisions
p.
4
of 10 CFR Part 71, "Packaging and Transportation of Radioactive Material".
>:
4
R:
f 16. Except as specifically provided otherwise in this license, the licensee shall
[l
g
conduct its program in accordance with the statements, representations, and
p
4
procedures contained in the documents' including any enclosures, listed below,
g
I,
y
The Nuclear Regulatory Comission's regulations shall govern unless the
k
[4
statements, representations and procedures in the licensee's application and
>-
{j
correspondence are more restrictive than the regulations,
y
i
A.
Application dated March 5,1986
[
- l
B.
Letter dated April 1, 1986
p
q
s
C.
Letter dated April 2,1987
p
4
D.
Letter dated July 10, 1987
>
j
E.
Letter dated September 25, 1987
h
f
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
dj
ik
,
original signed by B. A. Riedlinger
l>
l{>
l
Date October 15, 1987
By
Beth A. Riedlinger
Health Physicist (Licensing)
l
l
Nuclear Materials Safety Section
S
l
Degion V
- )
>
!
>>
i
AravaramuraTsansavamsmrasTATazrmvamarsamuramaarmesws
i