Confirmatory Action Ltr RIII-88-024 Re Repeat Failure of Reactor Recirculation Loop B Discharge Valve to Close on Signal from Control Room.Util Actions to Resolve Issue Acceptable.Concurs W/Decision to Restart Reactor
ML20155D233
Person / Time
Site: Fermi 
Issue date: 10/04/1988
From: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Sylvia B
DETROIT EDISON CO.
References
NUDOCS 8810110139
Download: ML20155D233 (2)


Text

_ _ _ -

OCT 4 1988 Docket No. 50-341 The Detroit Edison Company ATTN:

B. Ralph Sylvia Senior Vice President Nuclear Operations 6400 North Dixie Highway Newport, MI 48166 Gentlemen:

Reference:

Confinnatory Action Letter (CAL) RIII-88-024 This letter confirms the telephone conversation between Mr. H. J. Miller of this office and Mr. W. S. Orser of your staff on October 4,1988, regarding l

a Confinnatory Action Letter (CAL-RIII-88-024) issued August 30,1988, for Fenni. This CAL was in regard to the repeat failure of the "B" reactor recirculation loop discharge valve to close when signaled to do so from the control room. Based on our meeting at the NRC's Region III office on September 27, 1988; your submittal dated September 28, 1988; and several subsequent telephone conversations, we have concluded that the actions you have taken satisfy the requirements of the Confirmatory Action Letter.

l Therefore, I concur with your decision to restart Fermi and CAL-RIII-88-024 will be closed upon issuance of NRC Inspection Report No. 50-341/88025(DRS).

l Should you have any questions. I will gladly discuss them with you.

Sincerely.

Original signed by Carl J. Paperiello (for)

A. Bert Davis Regional Administrator See Attached Distribution nr vtr W

g h

p ni 1 son /jk Cooper Mfr son Knop

. iller 10/04/88 10/ov/88 10/ /68 10/W/88 10/*4 /88 RIII Rl!! m RI R

fiff v ~,

((f[

h i

gGMe.an Virgilic h rTo 'e apdriello s

10/o4/88 10/a'r/88 10/q/88 10/6T88 10/tV/88

{$A*A85338!$8llgt 3(p

The Detroit Edison Company 2

Distribution cc:

Patricia Anthony, Licensing P. A. Marquardt, Corporate Legal Department DCD/DCB(RIDS)

Licensing Fee Management Branch Resident Inspector, RIII Ronald Callen, Michigan Public Service Coninission Harry H. Voight, Esq.

Michigan Department of Public Health Monroe County Office of Civil Preparedness J. Strasma, RIII J. Clifford, ED0 W. Lenning, NRR F. Miraglia, NRR G. Holahan, NRR M. Virgilio, NRR T. Quay, NRR J. Lieberman, OE L. Chanaler, 0GC