OPERATING DATA REPORT DOCKET NO. 030-0298
. + -
DATE n6-n6-R8 COMPLETED BY J.
T.
Scheuerman TELEPHONE (402) 825-3811 OPERATING STATUS bOI'5'
- 1. Unit Name: _ Cooper Nuc1nar Station
- 2. Reporting Period:
May 1988 2381
- 3. Licensed Thermal Power (MWt):
836
- 4. Nameplate Rating (Gross MWe):
778
- 5. Design Electrical Rating (Net MWe):
7R7
- 6. Maximum Dependable Capacity (Gross MWe):
764
- 7. Maximum Dependable Capacity (Net MWe):
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report,Give Reasons:
- 9. Power Level To Which Restricted,if Any (Net MWe):
- 10. Reasons For Restrictions,if Any:
This Month Yr..to.Date Cumulative
- 11. Hours In Reporting Period 744.0 3,647.0 _
122,016.0
- 12. Number Of Hours Reactor Was Critical 0.0 1.297.0 91,304,4
- 13. Reactor Reserve Shutdown llours 0.0 0,0 0.0
- 14. Hours Generator On.Line 0.0 1,281.2 89,825.6
- 15. Unit Reserve Shutdown Hours 0,0 0.0 0.0
- 16. Gross Thermal Energy Generated (MWH) 0.0 2,629,440.0 177,260,147.5
- 17. Gross Electrical Energy Generated (MWH) 0.0 872,027.0 56,931,108.0
- 18. Net Electrical Energy Generated (MWH) 0.0 840.096.0 54,868,720.0
- 19. Unit Service Factor 0.0 35.1 73.6
- 20. Unit Availability Factor 0.0 35.1 73.6
- 21. Unit Capacity Factor (Using MDC Net) 0.0 30.2 58.9
- 22. Unit Capacity Factor (Using DER Net) 0.0 29,6 57.8
- 23. Unit Forced Outage Rate 0.0 16.8 4.8
- 24. Shutdowns Scheduled.Over Next 6 Months (Type. Date.and Duration of Each):
- 25. liShut Down At End Of Report Period. Estimated Date of Startup:
June 10, 1988
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achieved INITIA L CRITICALITY INITIA L ELECTRICITY COMMERCI AL OPER ATION 8806140322 880531
{DR ADOCK 05000293 (9/77:
AVERAGE DAILY UNITl OWER LEVEL DOCKET NO.
050-0298 UNIT CNS DATE 06-06-88 COMPLETED BY J. T. Scheuerman
/,
TELEPHONE (402) 825-3811 MONTH May 1988 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1 0
37 0
.2 0
18 0
-3 0
19 0
4 0
20 0
5 0
21 0
6 0
22 0
7 0
23 0
8 0
24 0
0 25 0
9 10 0
26 0
1I O
27 0
12 0
28 0
13 0
0 29 14 0
30 0
15 0
3l 0
16 0
INSTRUCTIONS On this format. list the average daily unit power levelin MWe Net for each day in the reporting month, Compute to the nearest whole megawatt.
(9/77) e * -.
UNITS!!UTDOWNS AND POWillt REDUCI10NS DOCKliT NO.
050-0298 UNI T NAit E CNS DA1E 06-06-88 COAIPl.ETliD ltY J.
T.
Schonorrna n REPORT AlONTil May 1999 lELEPllONE (402) 825-181i l
.$ E "g
Y 1.icensee 5-(
1, Cause & Cinacceive N".
DJ!c Q
5$
R
_E s E livent u?
o-3 Acilim to f5 5
5 Q, y Itcputt it NG
&U Psevent itecut Lacc O
O 88-02 880305 S
744.0 C
2 N/A N/A N/A Reactor shut down for 1988 (EOC 11)
Refueling and Maintenance Outage i
l t
2 3
4 17: Forced Itesson:
Method:
1:ahibit G-Instructions 5: Scheduled A-linguipmen Failure (Explain) 1-Manual
- for Pseparation of Daia Il-Maintenance of Test 2 Manual Scram.
lin: y Sheces fin 1.ieensee C Itefueling 3 Automatic Scram.
IIrent Itcp.n (Llilt)liite INtiltl'ti-D Itegulatory itestriction 1-Othet (lixplain) 0161)
IM1perator Training & l.icense !!xaminatinn 12 Administrative 5
G.Operasinnal Error (Explain)
Exhibii 1. Same Source
~ l'8/77 ).
Il-Other (Explain)
i
~
Operations Narrative Cooper Nuclear Station May 1988 The plant remained shut down in May for the 1988 (EOC 11) Refueling and Maintenance Outage,
a e
o COOPER NUCLET.R STATION g' ?!4 F
Nebraska Public Power District
" ' " "A"e" aliM;1""^i" ^ " " '
l CNSS887287 June 6, 1988 Document Control Desk U.S. Nuclear Regulatory Commiasion Washington, D.C.
20555
Subject:
Monthly Operation Status Report for May, 1988 Docket No. 50-298 Gentlemen:
Enclosed for your information and use is the Cooper Nuclear Station Monthly Operating Status Report for May, 1988. The report includes Operating Status, Average Daily Unit Power Level, Unit Shutdown Data, and a Narrative Summary of Operating Experience.
Should you have any comments or require additional information regarding this report, please contact me.
Sin re y
W Horn Division Manager of Nuclear Operations GRH/JTS:ss Enclosure cc:
G. D. Watson w/ enc.
R. D. Martin w/ enc.
\\\\
memammusumurmermmammmaarrmanners a -.
-