Text
ff.-l Q SEP2;gy f
.o Rick Jacobs Institute of Nuclear Power Operations Suite 1500, 1100 Circle 75 Parkway i
Atlanta, Georcia 30339-3064 l
f
Dear Mr. Jacobs:
Enclosed for your information is our biweekly listing of generic comunications l
being(considered or under development by the NRC staff.These include Bulle.
tins type coded BL on the list), Information Notices (!N) and Generic letters (GL).
Tits listing includes all proposed generic comunications that had been l
reported to us by $eptember 15, 1988.
i We have added a new category of listings consisting of Temporary Instructions
[
(TI).
The Temporary Instructions Itsted cover the special NRC inspection effor^ resulting from certain generic comunications.
In addition, starting i
with this listing, the subject column for all new entries will be prefaced by the bracketed word (NEW) to facilitate the identification of new entries added l
since the publication of the previous listing.
l Sincerely, Original Signed By f
Carl H. Ecrlinger Carl H. Berlinger, Chief i
Generic Cow unications Branch i
Division of Operational Events Assessment l
Office of Nuclear Reactor Regulation l
Enclosure:
As stated i
a
)
DISTRIBUTION w/ M elosure 111 NRC Division Directors
~
i All NRC Branch Chiefs j
t
'I OCKirkpatrick, NRR
[
FDR
(
I CeleeliFiles -
I l
g 00EA R/F l
OGCB R/F l
0Kirkpatrick R/F i
L0erderian. 00L l
RBarber, DOE l
- SEE PREY!0US CONCURRENCES OM3
)h l
J
- 0GCB:DOEA:NRR C/0GCB:DOEA:NRR l
DCKirkpatrick CHPeritnger hj g )'
, v A
f3 j
09/16/88 09/r /88 1J '
i L
r I
h
$$A $7 00!$$h
'y
{
p--
Dennis L. Fadden Institute of Nuclear Power Operations Suite 1500, 1100 Circle 75 Parkway Atlanta, Georgia 30339-3064
Dear Mr. Fadden:
our biweekly listing of generic communications Enclosed for your infoi" a
. tent by the NRC staff. These include Bulle-being(consideredorund-
, Information Notices (IN) and Generic Letters tins type coded BL on
'e (GL). This listing int
. proposed generic communications that had been reported to us by Septemo,
.a, 1988.
We have added a new category of listings consisting of Temporary Instructions (TI). The Temporary Instructions listed cover the special NRC inspection Ir, addition, starting effort resulting from certain generic communications.
with this listing, the subject column for all new entries will be prefaced by the bracketed word [NEW], so that those who have an interest in the new entries do not have to review the entire listing.
Sincerely, Carl H. Berlinger, Chief Generic Communications Branch Division of Operational Events Assessment Office of Nuclear Reactor Regulation
Enclosure:
As stated DISTRIBUTION w/ enclosure All NRC Division Directors All NRC Branch Chiefs CERossi, NRR CHBerlinger, NRR DCKirkpatrick, NRR PDR Central Files OCS DOEA R/F OGCB R/F DKirkpatrick R/F LDerderian, DOE i
RBarber, DOE l
OGCB:00EA:NRR C/0GCB:00EA:NRR DCKirkpatr,(ck CHBerlinger 09//6/88 A(f, 09/ /88
Pcgn No.
1 SEP 211988 09/20/88 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC TP ORIGIN.
SUBJECT CONTACT PHONE ISSUE nFFICE DATE IN NRR/DRIS ENVIRONMENTAL QUALIFICATION Steve (301) 09/30/88 RVIB OF LIMITOROUE MOV ACTUATOR Alexander 492-0995 TERMINAL BLOCKS & MARATHON 1600 TERMINAL BLKS GL REGION HEAT EXCHANGER FOULING.
Vern Hodge (301) 11/01/88 492-1169 II IN NRR/DOEA BWR VESSEL OVERFILL EVENTS.
Pat (301) 09/23/88 EAD Baranowski 492-1156 IN NRR/ DEST ERRORS IN CALIBRATION OF Joe Joyce (301) 12/01/88 SICB LEAD / LAG AND RATE CIRCUITS IN 492-3265 REACTOR PROTECTION SYSTEMS.
GL NRR/DLPQ SAFETY PARAMCTER DISPLAY Dick (301) 11/01/88 SYSTEM - ACCEPTABLE METHODS Eckenrode 492-1014 OF IMPLEMENTING REQUIREMENTS GL RES/DE SAFETY RELATED MOTOR OPERATED Owen (301) 10/01/88 EIB VALVE TESTING AND INSPECTION Rothberg 492-3815 IN RES/EME LIMITOROUE SMA SPRING Jerry (301)
'0/15/88 DEFORMATION Weidenhamer 492-3839 IN NRR/DOEA CHANGE IN FORMAT FOR NRC Vern Hodge (301) 10/01/08 OGCB GENERIC COMMUNICATIONS 492-1169 GL RES/DE SIPPLEMENT TO GENERIC LETTER John (301) 12/01/88 SSEB 87-11 DEALING WITH ARDITRARY O'Brien 492-3928 INTERMEDIATE PIPE RUPTURE REQUIREMENTS GL NRR/ DEST REQUIREMENTS FOR REGOLUTION W.
C. Lyon (301) 10/01/88 SRXD OF GI99 FOR CSERATION WITH 492-0891 LOWERED RCS INVENTORY AND FOR RELATED ISSUES GL NRR/ DEST INSERVIFE INSPECTION OF W.
S.
(301) 01/30/09 EMTB PRESSURE RETAINING WELDS IN Ha:olton 492-0911 THE REACTOR VESSEL GL AEOD LICENSEE COMMITMENTS FOR John (301) 12/30/88 EMERGENCY RESPONSE DATA Hickman 492-4155 SYSTEM (ERDS) IMPLEMENTATION GL NRR/ DEST NRR RECOMMENDATION ON ISI OF Chen F. Tan (301) 12/30/88 ESGB MARK I & II STEEL 492-0829 CONTAINMENTS, REFUELING CAVITIES & ASSOC DRAINAOE SYS
Pcg6 No.
2 49/20/88 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC TP ORIGIN.
SUBJECT CONTACT oHONE ISSUE OFFICE DATE GL RES/DRPS INDIVIDUAL PLANT EXAMINATION Farouk (301) 09/22/88 RHFB FOR SEVERE ACCIDENT Eltawila 492-3910 VULNERABILITIES - 10 CFR 50.54 GL NRR/ DEST RESOLUTION OF GENERIC ISSUE Om P.
(301) 10/30/88 SELB B-56, DIESEL RELIABILITY Chopra 492-0835 GL NRR/ DEST INSERVICE TESTING FOR PUMPS Ted (301) 10/31/88 EMEB AND VALVES Sullivan 492-0901 GL NRR/DOEA LINE ITEM TECHNICAL Tom Dunning (301) 11/01/88 OTSB SPECIFICATION IMPROVEMENT -
492-1189 REMOVAL OF CYCLE SPECIFIC PARAMETER LIMITS GL NRR/DOEA LINE ITEM TECH SPEC Wayne (301) 10/15/88 OTSB IMPROVEMENT-RELOCATION OF Meinke 492-3152 RADIOLOGICAL EFFLUENT REQUIREMENTS TO OFFSITE DOSE CALCULATION MANUAL GL NRR/DOEA LINE ITEM TECHNICAL Tom Dunning (301) 10/15/88 OTSB SPECIFICATION IMPROVEMENT -
492-1189 REMOVAL OF COMPONENT LISTS IN NMSS/AB EVALUATION OF EXTERNAL Harriet (3( 1) 10/01/88 EXPOSURE READINGS OF LICENSEE Karagianni 49?-0633 i
PERSONNEL DOSIMETERS IN NRR/DRIS INADEQUATE ~ IRE DAMPER Joe (301) 11/10/88 VIB OPERABILITY TESTS UNDER AIR Petrosino 492-0979 FLOW CONDITIONS i
IN NRR/DRIS POTENTIAL MANUFACTURER Joe (301) 12/02/88 VIO DEFECTS IN CUTLER HAMMER E-30 Petrosino 492-0979 SWITCHES MANUFACTURED PRIOR TO A CERTAIN DATE IN REGION FAILURE OF AMP-KYNAR SPLICES A.
S.
(312) 10/01/88 III AND THOMAS h BETTS NYLON WIRE Gautam 790-5523 CAPS DURING EQUIPMENT OUALIFICATION TESTING IN NRR/DREP IMPROPER IMPLEMENTATION OF Tom Essig (301) 10/05/88 RPB HIGH RADIATION AREA CONTROL 492-1146 REQUIREMENTS 4
GL NRR/ DEST MINIMUM EDGE DISTANCE FOR J Ma & R (301) 11/01/88 ESGB INSTALLATION OF ANCHORG IN Lipinski 492-1376 CONCRETE t
.m
i Pcgo No.
3 C9/20/88 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC r
TP ORIGIN.
SUBJECT CONTACT PHONE ISSUE OFFICE DATE IN NRR/ DEST THERMAL STRATIFICATION P.
T.
Kuo (301) 10/01/88 EMEB INDUCED OVERSTRESS CONDITION 492-0907 OF SURGE LINE PIPING AT TROJAN IN NRR/DRIS SUPP TO IN 87-33: 10CFR PART J.
J.
(301) 09/30/88 VIB 21 ISSUES REGARDING Petrosino 492-0979 PDRIS INADEOUATELY PERFORMED EVALUATIONS OF DEVIATIONS &
NONCONFORMANCES IN NRR/DRIS VALVE FRICTION FORCE J.
J.
(301) 01/17/89 VIB CALCULATION METHODS IN REGARD Petrosino 492-0979 PDRIS TO VALVE OPERATOR SIZING IN NRR/DRIS DEFECTIVE MOTOR SHAFT KEYS IN Jeff (301) 09/30/88 RVIB LIMITOROUE MOTOR ACTUATORS Jacobson 492-0996 4
IN AEOD THE REPORTING OF SAFETY VALVE Mary S.
(301) 10/15/88 AND SAFETY-RELIEF VALVE Wegner 492-7818 EVENTS PURSUANT TO 10 CFR 50.73 GL NRR/DREP CHANGE IN THE REGULATORY John (301) 10/03/88 PRPB LIMIT FOR OCCUPATIONAL Buchanan 492-1097 EXPOSURE OF THE SKIN TO BETA RADIATION FROM HOT PARTICLES IN NMSS ACTIONS TAKEN TO DATE ON Michael (301) 10/01/88 DLLWD/TB TOPICAL REPORTS ON LOW LEVEL Tokar 492-0590 WASTE FORMS AND HIGH INTEGRITY CONTAINERS IN NRR/DRIS KAPTON INSULATION USED IN Richard C.
(301) 10/01/88 VIB ELECTRICAL CONTAINMENT Wilson 492-0997 PENETRATION CIRCUITS 1
l IN NMSS SHIPMENT OF CCNTAMINATED A.
W.
(301) 11/15/88 SGTR/OD EQUIPMENT BETWEEN NUCLEAR Gre11a 492-3381 POWER STATIONS GL NRR/DOEA VOLUNTARY ENTRY INTO R.
J.
(301) 11/15/88 OTSB TECHNICAL SPECIFICATION 3.0.3 Giardina 492-1188 GL RES/DSIR ASME SECTION 3 REPLACEMENTS Robert (301) 12/15/88 EIB Kirkwood 492-3814 I
GL RES/IED RESOLUTION OF: GI/70, PORV R Kirkwood 492-3814 12/15/08 t< RPSIB AND BLOCK VALVE RELIABILITY, E Throm
-3567 AND GI/94, ADDITIONAL LOW TEMP OVERPRESS PROTECTION FOR LWRS
~
Pcga No.
4 09/20/88 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC
=
TP ORIGIN.
SUBJECT CONTACT PHONE ISSUE OFFICE DATE TI NRR/ DEST [NEW3 INSDECTION OF A.
(301) 01/15/89 EMEB IMPLEMENTATION OF BULLETIN Masciantonio 492-0920 TO EXTEND IEB 85-03 "MOV COMMON MODE FAILURES DURING PLANT TRANSIENTS TI NRR/ DEST ENEWJ INSPECTION OF T.
E.
(301) 03/01/89 SRXB COMPLIANCE WITH BULLETIN Collins 492-0897 88-04: "SAFETY-RELATED PUMP LOSS" TI NRR/DRIS ENEWJ INSPECTION OF Jim Conway (301) 11/01/88 LVIB IMPLEMENTATION OF BULLETIN 492-0978 07-02: FASTENER TESTING TO DETERMINE CONFORMANCE WITH MATERIAL SPECS TI NRR/ DEST [NEW3 MONITOR LICENSEE L.
Phillips (301) 10/01/88 SRXB RESPONSES TO BULLITIN 88-07:
492-3235 POWER OSCILLATIONS IN BWRs TI NRR/DRIS ENEWJ FOLLOW-UP OF RESPONSES Ray (301) 01/06/89 TO BULLETIN 88-05:
Cilimberg 492-3220 NONCONFORMING MATERIALS PROVIDED BY PSI /WJM IN REGION
[NEW3 OPERATING WITH MULTIPLE Z, Falevits (312) 10/30/88 III GROUNDS IN DIRECT CURRENT 790-5772 DISTRIBUTION SYSTEMS IN REGION V CNEW3 DETERIORATION OF Jaime (301) 10/07/88 WESTINGHOUSE ARD440 RELAYS Guillen 492-1170 IN REGION I CNEWJ STATION BATTERY CELL Julio Lara (215) 10/28/88 DEGRADATION 337-5144 DL NRR/ DEST ENEW3 NONCONFORMING Paul Gill (301) 10/01/88 SELD ELECTRICAL EQUIPMENT 492-0811 COMPONENTS AND DEVICES TI NRR/ DEST ENEW3 FOLLOWUP TO GENERIC Warron Lyon (301) 10/15/88 SRXD LETTER ON OPERATION WITH 492-0891 LOWERED REACTOR COOLANT SYSTEM INVENTODY BL NRR/ DEST ENEWJ UNEXPECTED SURGE LINE S.
Hou (301) 12/01/88 EMED DEFLECTION DUE TO THERMAL 492-0904 STARATIFICATION
I
- Pcg2 No.
5 09/20/08 PROPOSED GENERIC COMMUNICATIONS IN PREPARATION WITHIN THE NRC TP ORIGIN.
SUBJECT CONTACT PHONE ISSUE OFFICE DATE GL NRR/DLPO ENEW3 REVISIONS TO John Hannon (301) 09/23/88 LOLB NRC-ADMINISTERED 492-1031 REQUALIFICATION EXAMINATIONS IN NRR/ DEST ENEW3 POTENTIAL FOR Y.
Li (301) 10/15/88 EMEB DEGRADATION OF CHECK VALVES 492-0915 DUE TO REDUCED POWER
)
OPERATION DURING THE DROUGHT i