l.

1 l.-

. REGISTRY OF-RADIOACTIVE' SEALED-SOURCES AND DEVICES

~ SAFETY EVALUATION OF SEALED l SOURCE NO.: NR-3'00-S-854

' DATE:

,gy y.g PAGE 1 OF'4

-SEALED SOURCE-TYPE:< Seal'edi ource S

4 4

MODEL':

.. CS-1000 ~. (HPI.

I MANUFACTURER / DISTRIBUTOR:

Gamma Industries, Inc.

P.O.

Box 2543 i

Baton Rouge,fLA. 70821 j

i ISOTOPE:

MAXIMUM ACTIVITY:

Any' Beta-Gamma Emitter-20 Ci- (740 GBq)

LEAK ' TEST FREQUENCY:

6 Months PRINCIPAL USE:

(F) Well Logging CUSTOM SOURCE:

YES X

NO 9810260204'981021 PDR RC SSD PDR

l REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE NO.: NR-300-S-854-S DATE:

OCT 2'1 1998 PAGE 2 OF 4 i

SEALED SOURCE TYPE: Sealed Source DESCRIPTION:

The CS-1000 (HP) source is used for well' logging'in custom designed logging tools, in industrial gauging devices, and other applications' requiring the source capsule to withstand temperatures from -57 to +595 C (-70 to 1,103 F), and pressures to 25,000 psia (172.38 MPa).

The radioactive material (ceramic or metallic pellets) is doubly encapsulated in 304 or 316 stainless steel.

The inner capsule is cylindrical with 0.019" (0.48 mm) minimum wall thickness.

The seal weld is performed using.a "TIG" welding technique. -The inner capsule is inserted into the outer capsule and a threaded end plug is inserted and "TIG" welded in position.

Outer capsule wall thickness is maintained at 0.030" (0.76 mm) minimum.

The completed source assembly is 1.485" ( 3. 77 cm) 'long by 0. 3 44 "

(8.73 mm) diameter.

External threads.on the end plug are 8-32 UNC, 0.070" (1.78 mm)'-long.

LABELING:

.The outer: capsule will be engraved with the following information:

.GI-Mod.

CS-1000.- (HP)

.....Ci

................(isotope)

Ser.#

..................(serial no.)

Date PROTOTYPE TESTING:

This source assembly has a classification of 46515 (well logging) as described in ANSI publication N5.10-1968.

The manufacturer L

states that prototype sources have met the test criteria j

specified in the ANSI document.

.~

~

. REGISTRY.0F' RADIOACTIVE-SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE 1

NO.: NR-3 0'0 - S - 8 5 4 '- S DATE:

OCT. 21 1998

-PAGE 3 OF 4 SEALED SOURCE' TYPE:. Sealed. Source QUALITY ASSURANCE AND CONTROL:

Each source is visually inspected'aftersinner.and outer capsule.

. welding, then subjected to a contamination wipe-leak test.

If.

-l

'the wipe test indicated: contamination, then a hot water bubble test will be. performed.

LIMITATIONS.AND/OR OTHER CONSIDERATIONS OF USE:.

. The source shall be possessed and used by persons specifically. licensed by the NRC or an Agreement State.

.-Handling, storage, use, transfer, and disposal:

To be

' determined by the licensing. authority.

. This registration sheet and the information. contained within the references shall not lme changed without the written consent of the NRC.

SAFETY ANALYSIS

SUMMARY

. The : Model CS-1000 -(HP) source is no longer manufactured or Edistributed'by Gamma Industries, Inc. and Gamma Industries, Inc.

isfno:-longer;;in' business.

Therefore, the registration certificate'is being converted to an inactive registration certificate.

i e

l l

l l

i-1

- - - ~.

l l

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY' EVALUATION OF SEALED SOURCE L

t-NO.:'NR-300-S-854-S DATE:

OCT 21 -1998 PAGE 4 OF 4 SEALED SOURCE TYPE: Sealed Source i.

SAFETY ANALYSIS

SUMMARY

The source was originally approved for licensing purposes-by the i

Louisiana. Division of. Radiation Control.

NRC attempted to obtain D

_ copies of all'information submitted by the registrant in support

. of the evaluation.

However, NRC.could not locate all the information.

Therefore, no safety evaluation of the source.was E

performed as part of the., conversion of:the certificate to inactive status.

ISSUING AGENCY:

U.S. Nuclear. Regulatory Commission'

- Date:

2 l 1998 Reviewer:

'k

[

. John W.

Lubinski i

./.

L-Date:

- N 2 T 100o

. Concurrence:

/1', ]M /d,, _ m ls

~

Michele L. Burgdss L-

+

s

(

i.

PAGE 1 l

NRC FORM 567 U. S. NUCLEAR REOULATORY COMMISSION i

(6es)

REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION w%L. -

J INSTRUCTIONS: Send tNs request AND a copy of all reisted letterstapplications and draw 6ngs to: The Scaled Source Safety Section, ATTN: Chief, OWFN Mail Stop 6 H3. Change the Ucense Tracidng System rnilestone to 19 and assign to reviewer code I-S.

NOTE: Retain a copy of this request with the application and background f':ss.

REQUEs1 7)Ory)/y)d.

/')d// $

f REGION / LOCATION:

TELEPHONE kUMBER DAtE

~

/83 lI R 11 lil IV V R HQ LFDCB TYPE OF ACTION REQUESTED (Check as ;- -vin; APPUCANTS NAME SOURCE REVIEW AMENDMENT OF REGISTRATION SHEET uAn. CONTROL NUMBER (S)

DEVICE REVIEW NUMBER (S) l LETTER /APPUCATON OATE UCENSE NUMBER (S)

CUSTOM REVIEW

/Sh COMMENTS.

7 c(m a. 4Jis+nes,

'<>C -

0-

.x

-25y3

-Inn Amice

/A

'7MfDI

'~

JOR stSS USE ONLY "IZA"inerD7xhlaI "~"~ 9 & S D 578MK DATE h I~

~'

OATE TO FEES DATE RECENEO f/nM3 TYPE OF ACTION (Indicate the number of each type)

/

l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPUCANT (CUSTOM)

SOURCE (9C)

DEVICE (9A)

SOURCE (90)

DEVICE (98)

NEW JEW NEW NEW

] AMENDMENT AMENDMENT AMENDMENT AMENDMENT j NO SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED j OTHER (Specify)

TOTAL NUMBER OF NOTES k

/

1 NUMBER OF DEFICIENCY LETTERS NUMBER OF DEFICIENCY CALLS FOR BILLING PURPOSES ONLY REGISMATN j MODUCT EM-NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY TYPE OF FEE

( ( N L ys FEE CATEGORY

~

9C R 90

\\

l9A U 98 i

CHECK NUMBER AMoVNT REgvED MATANN UPDATED

/

AS REQUIRED

[

j p

j MATSYS UPDATED OATE OF CHECK LOG MV# % %

hMb(h ku AS REQUIRED APPROVED BY DATE RETURNV /}

DATE

(

)

COMMENTS

\\

L NRC FORM $61 (Se3)

NINA! TO 8888

l -.

l-c 1

l I

/

l

[

\\

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.:

LA30001330 DATE:

April 1977 PAGE 1 0F 5 DEVICE TYPE:

. Radiographic Exposure Device MODEL:

Pipeliner Model 201 MANUFACTURER / DISTRIBUTOR:

Gamma Industries, Inc.

P.O. Box 2543 Baton Rouge, LA 70821 MANUFACTURER / DISTRIBUTOR:-

SEALED SOURCE MODEL DESIGNATION:

Gamma Ind. PL-2 I

ISOTOPE:

Iridium-192 MAXIMUM ACTIVITY:

200 curies Depleted Uranium Shielding, 11.5 kilogrums LEAK TEST FREQUENCY:

POINCIPAL USE:

Industrial Radiography l

CUSTOM DEVICE:

YES X N0 l

l k

AW f

.