j' REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY _ EVALUATION OF_ SEALED SOURCE lNO.: NR-300 S-861-S DATE:
OCT 21 1998' PAGE 1 OF 3
' SEALED SOURCE TYPE: Radiography Source MODEL:
VXP'
- MANUFACTURER / DISTRIBUTOR:
Gamma Industries, Inc.
P.O.--Box 2543 Baton-Rouge,-LA'.70821 ISOTOPE:
MAXIMUM ACTIVITY:
l Iridium-192 30 Ci (1.11 TBq)
LEAK TEST FREQUENCY:
- 6. Months PRINCIPAL USE:
(A) Industrial Radiography
' CUSTOM SOURCE:
YES X
NO 9810260096 981021 PDR RC
[
- SSD PDR g
t 4
,e
-4 a
m y
m
Y' s
~
(,
REGISTRYf0F RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY. EVALUATION OF SEALED SOURCE NO.: NR-300-S-861-S DATE.
OCT 21E1998 PAGE 2 OF 3
~
' SEALED SOURCE-TYPE: Radiography Source DESCRIPTION:
- The Model VXP capsule consists of Iridium-192 metallic pellets, contained'in a singly encapsulated aluminum 7075-T651, or-stainless steel 304, 316 enclosure.
.The capsule cavity is sealed by insertion of a plug that is heliarc (TIG) welded to the main capsule body.
The outside of the capsule is threaded for insertion inte a 7/16-20NF taped hole, and the end has a.1/16" (1.59 mm) screw: driver slot for inserting.
The source is designed for use in the North American X-Ray Model VXR-F and the VXR-G Exposure-Devices.
Loading of the exposure device should
-only be done at Gamma Industries.
' PROTOTYPE TESTING:
~These sources have a classification of E32212, as described in ANSI publications N5.10-1968. The manufacturer states that
- prototype sources have met the test criteria specified in the
. ANSI document.
' QUALITY ASSURANCE AND CONTROL:
Each source assembly is visually inspected after fabrication, then subjected to a contamination wipe test.
If the wipe test indicates contamination,Lthan a hot water bubble test will be performed.
LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:
.* The device shall be possessed and used by persons
- specifically licensed by the NRC or an Agreement State.
- Handling, storage, use, transfer, and disposal:
To be determined by the licensing authority.
- 'This registration sheet and the information contained within the references shall not be. changed without the written consent of the NRC.
p
~
REGICTRY OF RADIOACTIVE SEALED-SOURCES AND DEVICES
-SAFETY EVALUATION OF SEALED SOURCE HNO.:-NR-300-S-861-S
- DATE:
OCT 21 1998 PAGE 3 OF 3-
-SEALED SOURCE TYPE: Radiography Source SAFETY-ANALYSIS
SUMMARY
The Model VXP source.is no longer-manufactured or distributed by
' Gamma Industries, Inc.4 and Gamma Industries, Inc. is ao longer in business.
Therefore,' the registration. certificate is being converted to an inactive' registration ' certificate.
The source:was. originally. approve'd-for/ licensing purposes by the Louisiana Division of Radiation Control.
NRC attempted to obtain copies of all_information submitted-by?the! registrant in-support l of the' evaluation. 'However, NRC could not' locate all the information.
Therefore,.no* safety evaluation ~of the source was
- performed as partLof the.. conversion of the certificate to sinactive status.
-ISSUING AGENCY:
U.S. Nuclear Regulatory ~ Commission
. ?
/
OCT 211998 Reviewer:
, g>
-Date:
/J' ohn W.
Lubinski
.Date':
I l999 Concurrence:
NkNd I oufa Michele L. Burgess
-1
v PAGE1 NRC FORM 567 U.S. NUCLEAR REGULATORY COMMISSION 5 83)
REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION Al?
INSTRUCTIONS: Send this request AND a copy of all related letters /appilcatkms and drawings to: The Seeled Source Safety Sechon, ATTN: CNef, OWFN Mail Stop 6 H3. Change the License Tracidng System milestone to 19 and assign to reviewer code I-5.
NOTE: Retain a copy of this request with the application and background files.
REQUESTER REGION / LOCATION:
a TQdHONE NUMBER DATE
~ ~
NfJ lI li til R IV RV R HQ LFDCB
_ })/M42'.
(
7/ ///
TYPE OF ACTION REQUESTED (Check as, vy.*___
APPUCANTS NAME SOURCE REVIEW AMENDMENT OF REGISTRATION SHEET N BER(S)
MAL CONTROL NUMBER (S)
DEVICE REVIEW A[R-3hh-h-h'8~5 terrER/APPUCATON DATE UCENSE NUMBER (S)
CUSTOM REVIEW l
b P6 Amf c23V Akta Wozure,3La '7689/
FOR SSSS USE ONLY REVIEWER MODEL NUMBERS NUMBER ASSIGNED
/On/
Wro
[
DATE AS$aGNED '
DATE TO FEES DATE RECEIVED
/
[;/]-
TYPE OF AC1,-e t,
.,M, e,
c.,,T,.)
l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)
SOURCE (9C)
DEVICE (9A)
SOURCE (90)
DEVICE (98)
]NEW.
~JiEW NEW
]NEW AMENDMENT AMENDMENT AMENDMENT AMENDMENT
/
_l NO SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED j OTHER (Specoy)
TOTAL NUMBER OF NOTES REVIEW HOURS
/r d--
l.
NUMBER OF DEFICIENCY LETTERS NUMBER OF DEFICIENCY CALLS FOR BILLING PURPOSES ONLY j NEW REGISTRATION -
_j PRODUCT INACTIVE -
f NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING
/
FOR FEE USE ONLY TYPE OF FEE C
FEE CATEGORY
{L dLNDy
]9A R 98
~
9C U 90 gS3 AMOUNT RECE>m CHECK NUMBER MATANN UPDATED
/
- AS REQUIRED
}
yM j MATSYS UPDATED DATE OF CHECK w
LOG
( r smW Dy AS REQUIRED
-oVEo.,
-E -"
dQ 5y
^'"
\\
COMMENTS
\\
l NRC FORM 667 @S3)
A NINAL.TO SSSS
.s pl$ 0 '
~
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES
[
SAFETY EVALUATION OF DEVICE (Amended in its entirety)
& 1 NR-300-D-145-S DATE: APR 171992 PAGE 1 OF 5 DEVICE TYPE:
Gamma Gauge MODEL:
1001 MANUFACTURER / DISTRIBUTOR:
Gamma Industries 2255 Ted Dunham Avenue Baton Rouge, LA 70821 SEALED SOURCE MODEL DESIGNATION:
Gamma Industries Model VD-HP Amersham Model CKC.P1
(
ISOTOPE:
MAXIMUM ACTIVITY:
Cobalt-60 2 curies Depleted Uranium 33 millicuries (91 kg)
LEAK TEST FREQUENCY:
6-month intervals PRINCIPAL USE:
(D) Gamma Gauges GUSTOM DEVICE:
X YES NO g53 CUSTOM USER:
Haynes International (previously Cabot Corporation) 1020 West Park Avenue-Kokomo, Di 46901
. k.
_,,n
.