ML20154Q855

From kanterella
Jump to navigation Jump to search
Special Rept 1-SR-86-007:on 860203,during Performance of Surveillance Test 41ST-1DG02,diesel Generator B Overspeed Trip Occurred.Caused by Fiber Optic Optical Transistor Failure.Fiber Optic Printed Circuit Board Replaced
ML20154Q855
Person / Time
Site: Palo Verde 
Issue date: 02/25/1986
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
1-SR-86-007, 1-SR-86-7, ANPP-35304-EEVB, NUDOCS 8603240137
Download: ML20154Q855 (2)


Text

i.

DECEIVED IP.C Arizona Nuclear Power ProJgt rc4 28 R412: 39 P O. BOX 52034 e PHOENIX, ARIZONA 85072-2034 February [h,bb6 ANPP-35304-EEVB/KLM/98.05 Mr. John B. Martin, Regional Administrator Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region V 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596-5638

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 1 Docket No. STN 50-528, License No. NPF-41 Special Report - Nonvalid Diesel Generator Failure Due to a Fiber Optic Transistor Failure File: 86-020-404: G.1.01.10: 86-056-026

Dear Mr. Martin:

Attached please find a Special Report (1-SR-86-007) prepared and submitted pursuant to Technical Specifications 4.8.1.1.3 and 6.9.2.

This report discusses a nonvalid diesel generator failure due to a component failure in the Fiber Optic System.

If you have any questions, please contact me.

Very truly yours, e-~

CRA L.

O 'N (m E. E. Van Brunt, Jr.

Executive Vice President Project Director EEVB/KLM/ dim Attachments j

cc:

R. P. Zimmerman (all w/a)

A. L. Hon E. A. Licitra A. C. Gehr INPO Records Center 8603240137 860225 PDR ADOCK 05000528 S

PDR q'

550/

f 3

^

~yttachm:nt uo ANPP-35304 s

PALO VERDE NUCLEAR GENERi11NG STATION UNIT 1 Special Report No.1-SR 007

-NONVALID DIESEL GENERATOR FAILURE DUE TO A FIBER OPTIC TRANSISTOR FAILURE Docket No.~STN-50-528 4 -

License No. NPF-41 x

h This Special Report of _ a Diesel Generator nonvalid failure is provided

~

pursuant to Technical Specification Sections 4.8.1.1.3 and 6.9.2, and includes the information recommended in Regulatory Position C.3.b of Regulatory Guide 1.108, Revision 1, August 1977.

.At -2350 on February 3,

1986, during performance of Surveillance Test 41ST-1DG02 in accordance with Technical Specification 4. 8.1.1. 2a, a Diesel Generator _ "B" overspeed trip occurred as a result of a Fiber Optic optical transistor failure.

This is not to be considered a valid test or failure because the trip was caused by a component. failure in the Fiber Optic System.

The Fiber Optic System is bypassed in the Emergency Mode of operation and, therefore, would not have prevented Diesel Generator "B" from starting in the s

-event of an emergency actuation signal.

At the time of this event, there had been 3 Diesel Generator failures in the last 100 valid tests (on a per nuclear unit basis) and the test interval. of not,more than 7 days was being implemented in accordance with the schedule of l

Regulatory Position C.2.d of Regulatory Guide 1.108.

]

The Fiber Optic printed circuit board containing the faulty optic transistor was replaced.

i 4

A valid test was performed and Diesel Generator "B" was returned to OPERABLE j

status at 1612 on February 5, 1986.

I 1

i e

i.

i t

I-F

_