May 26,1988 Docket No. 50-482 Mr. Bart D. Withers President and Chief Executive Officer Wolf-Creek Nuclear Operating Corporation i

Post Office Box 411 Burlington, Kansas 66839

Dear Mr. Withers:

SUBJECT:

REQUEST FOR ADDITIONAL' INFORMATION REGARDING THE WOLF CREEK STEAM GENERATOR TUBE RUPTURE ANALYSIS (TACNO.57363)

The staff is continuing its review of your May 15, 1987 submittal concerning the-Wolf Creek steam generator tube rupture analysis. The staff requests:

additional information identified in the enclosure to continue its review.

This request for information affects fewer than 10 respondents; therefore, OMB clearance is not required.under P.L.96-511.

Sincerely, Paul

. O'Connor, Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, Y and Special Projects

Enclosure:

As stated cc w/ enclosure:

See next page DISTRIBUTION

. Docket File j.

NRC PDR Local PDR PD4 Reading L. Rubenstein J. Calvo P. Noonan P. O'Connor OGC-Rockville E. Jordan J. Partlow ACRS(10)

PD4 Plant File PD4/LA//<

PD4/PM f PD4/D h PNoonan P0'Connor:sr JCalvo 05/s//88 05/2'f/88 05/17/88 G806020272 880524 PDR ADOCK 0500 2

f May 26, 1988 e

' Docket No. 50-482 Mr. Bart D. Withers President and Chief Executive Officer Wolf Creek Nuclear Operating Corporation Post Office Box 411 Burlington, Kansas 66839

Dear Mr. Withers:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING THE WOLF CPEEK STEAM GENERATOR TUBE RUPTURE ANALYSIS (TAC NO. 57363)

The staff is continuing its review of your May 15, 1987 submittal concerning the Wolf Creek steam generator tube rupture analysis. The staff requests additional information identified in the enclosure to continue its review.

This request for information affects fewer than 10 respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, Paul' 0'Connor, Project Panager Project Directorate - IV Division of Reactor Projects - III, IV, Y and Special Projects

Enclosure:

As stated cc w/ enclosure:

See next page I

i DISTRIBUTION Docket File NRC PDR Local PDR PD4 Reading L. Rubenstein J. Calvo P. Noonan P. O'Connor OGC-Rockville E. Jordan J. Partlow ACRS(10)

PD4 Plant File PD4/LA PD4/PM f PD4/D M l

PNoonan P0'Connor:sr JCalvo l

05h.//88 05/2M/88 05/17/88 L

l l

e.

e-gp ftGp p,

'o,,

UNITED STATES a

g NUCLEAR REGULATORY COMMISSION 5

.- l WASHING TON, D. C. 20655

  • g..... /

May 2 4,1988 Docket No. 50-482 Mr. Bart D. Withers President and Chief Executive Officer Wolf Creek Nuclear Operating Corporation Post Office Box 411 Burlington, Kansas 66839

Dear Mr. Withers:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING THE WOLF CREEK STEAM GENERATOR TUBE RUPTURE ANALYSIS (TACNO.57363)

The staff is continuing its review of your May 15, 1987 sutrittal concerning the Wolf Creek stcar generator tube rupture analysis. The staff requests additional infomation identified in the enclosure to continue its review.

This request for infomation affects fewer than 10 respondents; therefore, OMB cleararce is not required under P.L.96-511.

Sincerely, Paul W. O'Connor, Project Manager Project Directorate - IV Division of Reactor Projects - III.

IV, V and Special Projects

Enclosure:

As stated cc w/ enclosure:

See next page

0 Mr. Bart D. Withers Wolf Creek Generating Station Wolf Creek Nuclear Operating Corporation Unit No. I cc:

Jay Silbe_rg, Esq.

Mr. Gerald Allen Shaw, Pittman, Potts & Trowbridge Public Health Physicist 1800 M Street, NW Bureau of Air Quality & Radiation Washington, D.C.

20036 Control Division of Environment Chris R. Rogers, P.E.

Kansas Department of Health Manager, Electric Department and Environment Public Service Commission Forbes Field Building 321 P. O. Box 360 Topeka, Kansas 66620 Jefferson City, Missouri 65102 Mr. Gary Boyer, Plant Manager Regional Administrator, Region III Wolf Creek Nuclear Operating Corp.

U.S. Nuclear Regulatory Commissicn P. O. Box 411 799 Roosevelt Road Burlington, Kansas 66C39 Glen Ellyn, Illinois 60137 Pegional Administrator, Region IV Senior Resident Inspector / Wolf Creek U.S. Nuclear Regulatory Commission c/o V. S. Nuclear Regulatory Commission Office of Executive Director P. O. Box 311 for Operations Burlington, Kansas 66839 611 Ryan Plaza Drive Suite 1000 Arlington, Texas 76011 Mr. Robert Elliot, Chief Engineer Utilities Division Mr. Otto Maynard, Manager Licensing Kansas Corporation Commission Wolf Creek Nuclear Operating Corp.

4th Floor - State Office Building P. O. Box 411 Topeka, Kansas 66612-1571 Burlington, Kansas 66839 1

L

4 ENCLOSURE I REQUEST FOR ADDITIONAL INFORMATION 1.

In the May 15, 1987 response to the staff's request for additional informa-tion regarding the Wolf Creek Nuclear Operating Corporation estimated doses for a steam generator tube rupture accident assuming that offsite power was lost and that a safety valve on the secondary side of the plant failed to completely reseat. The staff notes that the estimated deses to the thyroid for Case 1 of this analysis are larger than the values in FSAR Table 15.6.5.

However, the submittal contains insufficient information for the staff to independently reassess these doses.

Please provide information for the present analysis that is similar to that in FSAR Table 15.6-4.

J=

t i

- _,