ML20154N071

From kanterella
Jump to navigation Jump to search
Responds to 880328 Request for Clarification as to Whether NRC Would Find Util Proposal to Classify All Induction Heating Stress Improvements Treated Welds as Category B When Not All Treated Welds Tested.Accepts Util Classification
ML20154N071
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 05/25/1988
From: Brown S
Office of Nuclear Reactor Regulation
To: Leonard J
LONG ISLAND LIGHTING CO.
References
GL-88-01, GL-88-1, NUDOCS 8806020177
Download: ML20154N071 (4)


Text

_ _ _ -

May 25, 1988

... e Docket No. 50-322 Mr. John D. Leonard Vice President-Nuclear Operations l

'Long Island Lighting Company Shoreham Nuclear Power Station P.O. Box 618, North Country Road Wading River, NY 11792 l

Dear Mr. Leonard:

SUBJECT:

CLARIFICATION OF IGSCC CATEGORY B WELDS - SHOREHAM This is in response to your March 28, 1988 request for clarification as to whether the staff would find LILCO's proposal to classify all induction heating stress improverent (IHSI) treated welds as Category B when responding to Generic Letter 88-01 even though not all post-IHSI treated welds were ultrasonicly tested. LILCO bases this request on the results of random ultrasonic testing of IHSI treated reactor recirculation system piping welds.

Twenty-five percent of these welds were tested and no indications of cracks were detected.

The staff will accept LILCO's classification of all IHSI treated welds as Category B when responding to Generic Letter 88-01 based on the above test results.

If any additional infonnation is required in this matter please do not hesitate to contact me at (301) 492-1444.

Sincerely,

/s/

Stewart Brown, Project Manager Project Directorate I-2 Division of Reactor Projects I/II DISTRIBUTION cDocket File /

NRC PDR/LPDR EDI-2 Peading SVarga/BBoger WButler M0'Brien SBrevn/GRivenbark OGC-WF Edordan JPartlow A

ACRS (10)

PDI-2/D I

PDI-2/PM

/S

/

)lButler bI SBrown:mr ze ton CYC ng

[

88

/J./88

{ / /88 5 (g88 l

8806020177 080525 PDR ADOCK 05000322 P

PDR

,. j o cto g

,,(

jo UNITED STATES g

gy g

NUCLEAR REGULATORY COMMISSION g

E WASHING TON, D. C. 20555

%q

/

May 25, 1988 Docket No. 50-322 Mr. John D. Leonard Vice President-Nuclear Operations Long Island Lighting Company Shoreham Nuclear Power Station P.O. Box 618, North Country Road Wading River, NY 11792

Dear Mr. Leonard:

SUBJECT:

CLARIFICATION OF IGSCC CATEGORY B WELDS - SHOREHAM This is in response to your March 28, 1988 reque.st for clarification as to whether the staff would find LILCO's proposal to classify all induction heating stress improvement (IHSI) treated welds as Category B when responding to Generic Letter 88-01 even though not all post-IHSI treated welds were ultrasonicly tested. LILCO bases this requeu on the results of random ultrasonic testing of IHSI treated reactor recirculation system piping welds.

Twenty-five percent of these welds were tested and no indications of cracks were detected.

The staff will accept LILCO's classification of all IHSI treated welds as Category B when responding to Generic Letter 88-01 based on the above test results.

If any additional infonnation is required in this matter please do not hesitate to contact me at (301) 492-1444.

Sincerely, Stewart Brown, Project Manager Project Directorate I-2 l

Division of Reactor Projects I/II i

l

Mr. John D. Leonard, Jr.

Shoreham Nuclear Power Station

.Long Island Lighting Company (list 1) cc:

Stephen B. Latham, Esq.

Gerald C. Crotty, Esq.

John F. Shea, III, Esq.

Ben Wiles Esq.

Twomey, Latham & Shea Counsel to the Governor Attorneys at Law Executive Chamber Post Office Box 398 State Capitol 33 West Second Street Albany, New York 12224 Riverhead, New York 11901 Herbert H. Brown, Esq.

Alan S. Rosenthal, Esq., Chairman Lawrence Coe Lanpher, Esq.

Atomic Safety & Licensing Appeal Board Karla J. Letsche, Esq.

U.S. Nuclear Regulatory Commission Kirkpatrick & Lockhart Washington, D.C.

20555 South Lobby - 9th Floor 1800 M Street, N.W.

Washington, D.C.

20036-5891 W. Taylor Reveley, III, Esq.

Hunton & Williams Dr. Monroe Schneider Post Office Box 1535 North Shore Comittee 707 East Main Street Post Office Box 231 Richmond, Virginia 23212 Wading River, New York 11792 Howard A. Wilber Fabian G. Palomino, Esq.

Atomic Safety & Licensing Appeal Board Special Counsel to the Governor U.S. Nuclear Regulatory Comission Executive Chamber - State Capitol Washington, D.C.

20555 Albany, New York 12224 Atomic Safety & Licensing Board Panel Anthony F. Earley, Jr., Esq.

U.S. Nuclear Regulatory Comission General Counsel Washington, D.C.

20555 Long Island Lighting Company 175 East Old County Road Atomic Safety & Licensing Appeal Board Hicksville, New York 11801 Panel U.S. Nuclear Regulatory Comission Mr. Lawrence Britt Washington, D.C.

20555 Shoreham Nuclear Power Station Post Office Box 618 Gary J. Edles, Esq.

Wading River, New York 11792 Atomic Safety & Licensing Appeal Board U.S. Nuclear Regulatory Comission Martin Bradley Ashare, Esq.

Washington, D.C.

20555 Suffolk County Attorney H. Lee Dennison Building Richard M. Kessel Veteran's Memorial Highway Chairman & Executive Director Hauppauge, New York 11788 New York State Consumer Protection Board Room 1725 Resident Inspector i

250 Broadway Shoreham NPS l

New York, New York 10007 U.S. Nuclear Regulatory Commission Post Office Box B Jonathan D. Feinberg, Esq.

Rocky Point, New York 11778 New Ynrk State Department of Public Service Regional Administrator, Region I Three Empira State Plaza U.S. Nuclear Regulatory Comission Albany, New York 12223 475 Allendale Road l

King of Prussia, Pennsylvania 19406 1

l

r i

_ y.

..s Long Island Lighting Company Shoreham (1) cc:

Robert Abrams, Esq.

Town Attorney Attorney General of the State Town of Brookhaven of New York 3232, Route 112 ATTH: John Corwin, Esq.

Medford, NY 11763 New York State Department of Law Consumer Protection Rureau 120 Broadway 3rd Floor New York, New York 10271 Mr. William Steiger Plant Manager Shoreham Nuclear Power Station Post Office Box 628 Wadino River, New York 11792 MHB Technical Associates 1723 Hamilton Avenue - Suite X San Jose, California 95125 Honorable Peter Cobalan Suffolk Countv Executive County Executive / Legislative Building Veteran's Memorial Highway Hauppauge, New York 11788 Ms. Donna Ross New York State Er.ergv Office Agency Puilding 2 Empire State Plaza Albany, New York 12223 Ms. Nora Bredes Shoreham Opponents Coalition 195 East Main Street Smithtown, New York 11787 Chris Nolin New York State Assembly Energy Committee 626 Legislative Office Building Albany, New York 12248 Peter S. Everett, Esq.

Hunton & Williams 2000 Pennsylvania Avenue, NW Washington, D.C.

20036