ML20154M696
| ML20154M696 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 05/25/1988 |
| From: | Standerfer F GENERAL PUBLIC UTILITIES CORP. |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| References | |
| 4410-88-L-0076, 4410-88-L-76, IEB-88-004, IEB-88-4, NUDOCS 8806020042 | |
| Download: ML20154M696 (2) | |
Text
-
GPU Nuclear Corporation U Nuclear
- oms r8o e
Middletown, Pennsylvania 17057-0191 717 944 7621 TELEX 84 2386 Writer's Direct Dial Number:
(717) 948-8461 May 25,1988 4410-88-L-0076/0386P US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
Dear Sirs:
Three Mile Island Nuc] ear Station, Unit 2 (TMI-2)
Operating License No. DPR-73 Docket No. 50-320 NRC Bulletin No. 88-04 NRC Bulletin No. 88-04 addressed the potential for safety-related pump loss during miniflow operation.
GoU Nuclear t'as reviewed '.he information presented in NRC Bulletin No. 88-04 and has determined that the safety-related pump loss described is not applicable to TMI-2 in the current recovery mode.
If a decision is made to restart TMI-2, this NRC Bulletin will be re-evaluated.
Based on the above, io further action is required relative to TMI-2.
Sincerely,
} I.
J j
'I f WJ
. Standerf Director, TMI-2 EDS/ emf Attactment cc: Senior Resident Inspector, TMI - R. J. Con' 3 Regional Administrator, Region 1 - W. T. Russell Director, Plant Directorate IV - J. F. Stolz Systems Engineer, TMI Site - L. H. Thonus 8806020042 880525 h' I PDR AD3CK 05000320 O
DCD GPU Nuclear Corporation 5 a subsidiary of the General Public Utilities Corporation j
I'-
{
... ~
ATTACHENT
+ -
4410-88-L-0076 ETROPOLITAN EDISDN COWANY JERSEY CENTRAL POWER Ato LIGHT COWANY PENNSYLVANIA ELECTRIC COWANY GENERAL PUBLIC UTILITIES NUCLEAR CORPORATION Three Mile Island Nuclear Station, Unit 2 (TMI-2)
. Operating License No. DPR-73 Docket No. 50-720 tRC Bulletin No. 88-04 This' letter is submitted in suoport of the Nuclear Regulatory Commission request concerning the May 5,1988, letter trar,smitting NRC Bulletin No.
88-04, "Potential Safety-Related Pump Loss." All statements contained in this response have been reviewed, and all such statements made and matters set
.forth therein are true and correct to tle best of my knowledge, information, and belief.
7
.i
/
F. R. 3tanderier V Director, TMI-2 S.4 7d and sworn before me this f _Mday of M A 4/
, 1988.
!MM 1$A
&ff9f
- Notary Public g
cemANt A. Ittmt m1ny avi,og MNf.(IWA (cfA 0.itlME CDbTTf
'?? CWN11un pty! 'Ji?C?! 20. ICC U % k. +v.x n ws s a w-*,,,
...