ML20154M271

From kanterella
Jump to navigation Jump to search
Forwards Detailed Review of Amend 13 to Plant Emergency Plan & Clarifications to Some Changes.Changes Meet Provisions of 10CFR50.47(b) & 10CFR50,App E Requirements
ML20154M271
Person / Time
Site: Trojan File:Portland General Electric icon.png
Issue date: 05/19/1988
From: Brown G
NRC
To:
NRC
Shared Package
ML20154M248 List:
References
NUDOCS 8806010237
Download: ML20154M271 (8)


Text

_ _ _ _ _ _

MEMORANDUM FOR:

File EP 5.3.1 FROM:

G. A. BEown, Emergency Preparedness Analyst Emergency Preparedness Section

SUBJECT:

. Trojan Emergency Plan Change, Ammendment 13 The subject Ammendment 13 of the' Trojan Emergency Plan'was submitted under cover letter TDW-297-88, dated April 15, 1988. to this memorandum is a detailed review of the changes submitted. provide clarifications to some changes.

The overall effects of the changes were minor, being directed toward updating the plan to reflect current titles and to add an additional outlet to their Emergency Broadcasting System.

The licensee is being notified that the changes meet the provisions of 10 CFR 50.47(b) and.the requirements of 10 CFR Part 50, Appendix f.

h/ f5W

/ G. A. Brown Attachments:

1.

"Detailed Review of Ammendment 13 Changes"

2.

"Clarifications of Ammendment 13 Changes" 0806010237 880519 DR p

ADOCK 0300o344 PDR

s TROJAN EMERGENCY PLAN CHANGES AMMENDMENT-13 MARCH 1988 CLARIFICATIONS 1.

Figure 6-5 of the Overview Section deletes discussion of dose rate at containment (7.5 E-3 R/hr) as possibly being an indication of fuel melt.

Why was this deleted?

LICENSEE RESPONSE:

We now have proper instrumentation to give us this information.

An Area Radiation Monitor in the containment has been environmentally qualified for continuous operation in all atmospheres of the containmnet.

2.

On Page OV 6-9, second paragraph, is a discussion on remotely activating the Emergency Broadcasting System during the off hours.

Is KOHI also activated?

If so, the discussion does not leave that impression.

LICENSEE RESPONSE:

Radio station K0HI will not be activated remotely.

It will be activated manually.

Equipment has been installed to tape and rebroadcast KBAM announcements over K0HI.

i i

3..

On Page PGE 3-55, Section 3.8.5.1, the revision deleted the task of performing cold startup of area radiation and ventilation as one of the duties of the radiation protection technicians.

Why was this deleted?

LICENSEE RESPONSE:

Since we felt that the radiation protection technicians would likely be occupied in other tasks during an j

emergency, we transferred this responsibility to the dose assessment l

group.

l ATTACHMENT 2

i t

1 l

+

i DETAILED REVIEW 0F AMMENDMENT 13 MARCH 1988 CHANGES TO TROJAN NUCLEAR PLANT EMERGENCY PLAN l' A G E ORIGINAL REVISED OV 6-7 2nd specifies that the Dir, changes to state that CC paragraph of Columbia County OES OES releases emergency last sen, releases emergency messages via Emerg Broad-messages via KBAM Radio cast System (EBS)

OV 6-7 3rd specifies that Cowlitz changes to state that paragraph County sheriff releases sheriff releases last sen.

emergency messages via emergency messages via KBAM radio EBS OV 6-8 2nd directs public to tune to adds K0HI as an addi-para 1st KBAM for information tional station for public sen.

information OV 6-9 Item states that further states that further (6) information will be information will be given given over KBAM over KBAM and K0HI OV 6-9 2nd explains that KBAM does rewords the original para not operate 24-hours a paragraph to specify EBS day but that there is a rather than KBAM, dedicated link through however, K0HI apparently Cowlitz County to is not included in the remotely activate the off-hours dedicated re-station and broadcast mute activation link emergency messages OV 6-9 3rd discusses capability of deletes discussion of OR para OR Govenor to broadcast Govenor and substitutes over KBAM over dedicated OR E0C, Cowlitz County phone line from OR OEC and Columbia County E0Cs OV 6-9 4th N/A Adds discussion of dedi-para cated phone line to KOHI OV 6-12 Sec References PGE App C in Changes reference to PGE 6.3.7 dose calculations Section 1 Table Shows initial deposition Reduces concentration of OV 6-5 concentration for Cs-134 CS-134 to 20 uCi/sq m I

l l

PAGE - 0001.0.0 -

ATTACHMENT 1 I

PAGE ORIGINAL REVISED as 30 uCi/sq m for PAG Figure Specifics one hour time Deletes discussion of one 6-1 limit in notification of hour time limit and offsite agencies for a reduces notification time Notification of Unusual to 15 minutes for Colum-Event bia and Cowlitz Counties and 30 minutes for the two states' agencies Figure Flow chart for onsite Deletes "Unusal Event" as 6-4 protective actions, consideration and changes Provides actions for "and" to "or" Unusal Event or Alert "and" specifies dose rates Specifies protective decreases concertration action for 1-131 of I-131 to )0.25 MPC as concentrations LO.4 MPC protective action guide (PAG) threshold Specifies protective Increases concentration action for whole body to 1.0 Rem /hr for 1 hr as dose rate 10.1 Rem /hr PAG threshold.

N/A Adds specification for airborne activity concentration for PAG Specifies protective reduces PAG for 1-131 to action for I-131 con-

?.25 MPC and calls for centration of >100 MPC evacuation of ncnessen-and calls for use of tial personnel respirator gear Incluoed OSC personnel separates OSC personnel with other onsite plant and provides individual personnel for PAGs PAGs for those members N/A Adds PAG for airborne activity for TSC members contains PAG of WB dose deleted these PAGs PAGE - 0002.0.0 -

ATTACHMENT 1

=

1 PAGE ORIGINAL REVISED I

rate >10 Rem /hr for 5 minutes and I-131 con-centrations >1000 MPC for

'5 minutes for E0F person-i-

nel For EOF members contains deletes this discussion discussion on indica-tions of fuel melt and provides PAGs if these indications-are present 3

Figure Discusses PAG for loss of adds provision "due to a 0V 6-5 physical control of fa-security event" cility Figure Discusses dose rate at deletes this discusion 6

OV 6-5 containment surface of (Cont) 7.5 E-3 R/hr as a pos-sible indication of fuel melting OV 7-1 Item describes Automatic changes title to Decision 1

(2)(a)

Ring-down (ARD) telephone Makers telephone system system OV 7-2 Item describes Selective Sig-changes title to State (2)(b) nalling (SS-1) telephone Technical telephone system system l

l OV 7-2 Item describes Selective changes title to PGE (2)(c)

Signalling -2 (SS-2)

Management telephone telephone system system i

0V 7-2 Item describes Selective Sig-changes title to Opera-(2)(d) nalling-3 (SS-3) tional Support Center 3

telephone system Control telephone system.

System is also changed from 3-digit telephone numbers to 2-digit i

l OV 7-2 Item N/A adds Plant Status tele-i (2)(e) phone system that links CR, TSC, EOF and CSC, Used to exchange plant l

i i

i l

PAGE - 0003.0.0 -

ATTACHMENT 1 I

)

PAGE OR'I Gf N AL REVISED status information OV 7-3 4th describes NRC HPN system changes description to a pera as a dedicated telephone commercial telephone system system Figure Flow chart describing the updates to show the above 0V 7-1 emergency communications changes systems OV 8-9 Item provides instructions to changes instructions to (3)(a) dial radio to KSAM replace KBAM with "an EBS station" PGE 3-1 Sec references Figure PGE 3-1 deletes references to 3.1 which describes the Figure PGE 3-1 and refers normal day shift plant to the FSAR for day shift organization plant organization des-cription PGE 3-2 Sec references Figure PGE 3-5 changes the reference to 3.2.1 last which describes the emer-Figure PGE 3-3 para gency organization after the arrival of key mem-bers of the E0F PGE 3-11 describes composition of adds the position of Sec 3.5 2nd the TSC staff Manager, Personnel Pro-para tection to the staff PGE 3-12 describes Plant General adds Manager, Personnel Sec 3.5.1 Manager position Protection to those who ist para may serve as duty Plant General Manager PGE 3-14 describes the Chemistry removes the Chemistry Sec 3.5.3 Supervisor as being under Supv from this authority the authority of the and places him as a Duty Manager, Tech Serv in the Manager TSC PGE 3-15 calls for the Mgr. Tech changes the interface so Sec 3.5.3 Serv to interface with that the Mgr. Tech Serv top of pg the Technical Support nnw interfaces with the PAGE - 0004.0.0 -

ATTACHMENT 1

i I

PAGE ORIGIhAL REVISED Director Duty Plant General Mgr Duties Item calls for the Manager removes these positions (1)

Tech Serv to supervise, from the supervision of among others, the Chem the Manager Tech Serv Supv and the Rad Prot Supv PGE 3-16 discusses the authority, Replaces the section with Sec 3.5.4 duties and responsibili-a discussion of the auth-ties of the Chem Supy ority, duties and respcn-sibilities of the Mana-ger, Personnel Protection PGE 3-17 assigne the Chem Supv reassigns the Chem Supv Sec 3.5.5 repor,Ing to the Manager, to report to the Manager, Tech Serv Personnel Protection PGE 3-22 describes the duty to changes to advising the Sec 3.5.12 advise the Technical Company Support Director (2)

Support Director PGE 3-28 describes the duty of the deletes that duty Sec 3.6.5 Rad Drot Emerg Team Coord (1) to verify the OSC RWP is initiated PGE 3-37 describes the duty of the changed to supervise the Sec 3.8.2 Emerg Response Mgr to Company Support Director (1) sup-er-vise the Tech Sup-PGE 3-43 describes the duties of Adds duties to communi-Sec 3.8.3.2 the E0F Security cate PARS to Coast Represey :ative Guard, communicating with Security Watch Supv. and PGE 3-55 Describes duties of rad-deleted duty to perform Sec 3.8.5.1 iation protection techni-cold startup of area rad-cians.

iation and ventilation PGE 4-1 Includes notificiation of Changes to notification Sec 4.2 2nd Security Watch Supy as of Secondary Alarm Sta-

sen, one of duties of Shift tion Operator.

Supervisor PAGE - 0005.0.0 -

ATTACHMENT 1

a PAGE.

ORIGINAL.

REVISED

PGE'4-2 n/a adds-discussien-on.ra-

.Sec'4-2 1st

..tionale for tir.es for-

- para-notifications of differ-ences

- Table PGE n/a adds 0SC to list of areas 4-1 last which are provided a sup-item ply of.KI tablets Y

.t T

i

,PAGE - 0006.0.0 -

ATTACHMENT 1

.