ML20154M031

From kanterella
Jump to navigation Jump to search
Advises That Util 860109 Request for Authorization to Conduct Fuel Handling Operations W/Hydrogen Mixing Fans & Containment Coolers Out of Operation Reviewed & Acceptable
ML20154M031
Person / Time
Site: Callaway 
Issue date: 03/07/1986
From: Youngblood B
Office of Nuclear Reactor Regulation
To: Schnell D
UNION ELECTRIC CO.
References
NUDOCS 8603130285
Download: ML20154M031 (2)


Text

__

Docket No.: 50-483 MAR 0 71996 Mr. D. F. Schnell Vice President - Nuclear Union Electric Company Post Office Box 149 St. Louis, Missouri 63166

Dear Mr. Schnell:

Subject:

Regt.est for Authorization to Conduct Fuel Handling Operations With the Hydrogen Mixing Fans and the Containment Coolers Out of Operation - Callaway, Unit 1 By letter dated January 9,1986, you requested NRC review of your request for authorization to conduct fuel handling operations with the hydrogen mixing i

fans and the containment coolers out of operation. The existing FSAR analysis assumed these systems to be operating during a fuel handling accident inside containment thereby providing dilution for airborne activity inside of the containment building prior to release.

I You provided a new analysis of the fuel handling accident which calculated the radiological consequences of a dropped fuel assembly and assumed that the hydrogen mixing fans and containment coo!ers were not in operation.

The NRC staff has ccmpleted its review of your request to carry out fuel handling operations with the Callaway hydrogen mixing fans and containment coolers out of operation. Our independent review of a postulated fuel hand-ling accident, with no credit given for mixing within the containment building due to operation of the hydrogen mixing fans and the containment coolers, resulted in doses within the low population zone and the exclusion area boundary well within the 10 CFR 100 dose guidelines.

Based upon your submittal and our independent analysis summarized above, we conclude that your proposal to carry out fuel handling operations with the hydrogen mixing fans and containment coolers in operable is acceptable.

Sincerely,

\\s \\

B. J. Youngblood, Director PWR Project Directorate #4 Division of PWR Licensing-A cc: See next page i

Distribution:

M N0uncan BGrines NRC PDR BJYoungblood EJordan Local PDR PWR#4 Rdg OELD PRC System P0'Connor ACRS (10)

NSIC JPartlow i

PWRf4/DPWR-A/

PWR#4/0F(n w

hR-A P0'Connor/mac BJYoungblood 03/4 /86 03/ ( /86 06031302es e60307 gDR ADOCK 0 3

i

e o

Mr. D. F. Schnell Callaway Plant Union Electric Company Unit No. I cc:

Mr. Nichclas A. Petrick Lewis C. Green Esq.

Executive Director - SNUPPS Green, Hennings & Henry 5 Choke Cherry Road Attorney for Joint Intervenors Rockville, Maryland 20850 314 N. Broadway, Suite 1830 St. Louis, Missouri 65?51 Gerald Charnoff, Esq.

Thomas A. Baxter, Esq.

Ms. Marjorie Reilly Shaw, Pittman, Potts & Trowbridge Energy Chairman of the League of 1800 M Street,'i. W.

Women Voters of Univ.. City, M0 Washington, D. C.

20016 7065 Pershing Avenue University City, Missouri 63130 Mr. J. E. Birk Assistant to the General Counsel Mr. Donald Bollinger, Member Union Electric Company Misscurians for Safe Energy Post Office Box 149 6267 Delmar Boulevard St. Louis, Missouri 63166 University City, Missouri 63130 U. S. Nuclear Regulatory Comission Mr. Dan I. Bolef, President Resident Inspectors Office Kay Drey, Representative RRAI Board of Directors Coalition Steedman, Missouri 65077 for the Environment St. Louis Region Mr. Donald W. Capone, Manager 6267 Delmar Boulevard Nuclear Engineering University City, Missouri 63130 Union Electric Company Post Office Box 149 St. Louis, Missouri 63166 Chris R. Rogers, P.E.

Manager - Electric Department 301 W. High Post Office Box 360 Jefferson City, Missouri 65102 Pegional Administrator U. S. NRC, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Mr. Ronald A. Kucera, Ceputy Director Department of Natural Resources P. O. Box 176 Jefferson City, Missouri 65102 Mr. Glenn L. Koester Vice President - Nuclear Kansas Gas and Electric Company 201 North Market Street Post Office Box 208 Wichita, kansas 67201