OFFICIAL USE ONLY - PROPRIETARY INFORMATION June 5, 2020 Mr. Gary Peters, Director Licensing and Regulatory Affairs Framatome, Inc.
3315 Old Forest Road Lynchburg, VA 24501
SUBJECT:
DRAFT SAFETY EVALUATION FOR FRAMATOME INC. TOPICAL REPORT ANP-10337, REVISION 0, SUPPLEMENT 1P, REVISION 0, DEFORMABLE SPACER GRID ELEMENT (EPID: L-2018-TOP-0037)
Dear Mr. Peters:
By letter dated September 21, 2018 (Agencywide Documents Access and Management System (ADAMS) Package Accession No. ML18268A153), as supplemented by letters dated July 19, 2019 (ADAMS Package Accession No. ML19204A227) and November 8, 2019 (ADAMS Package Accession No. ML19317E157) Framatome, Inc. (Framatome) submitted Topical Report (TR) ANP-10337, Revision 0, Supplement 1P, Revision 0, Deformable Spacer Grid Element, to the U.S. Nuclear Regulatory Commission (NRC) staff for review and approval.
Enclosed for Framatome review and comment is a copy of the NRC staff's draft safety evaluation (SE) for the TR.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), we have determined that the enclosed draft SE may contain proprietary information. If you believe that any information in the enclosure is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Twenty working days are provided for you to comment on the proprietary aspects and provide any factual errors or clarity concerns contained in the draft SE. The final SE will be issued after making any necessary changes and will be made publicly available. The NRC staff's disposition of your comments on the draft SE will be discussed in the final SE.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION
OFFICIAL USE ONLY - PROPRIETARY INFORMATION To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SE showing proposed changes and provide a summary table of the proposed changes.
If you have any questions, please contact Ngola Otto at 301-415-6695.
Sincerely,
/RA- Michael D.Orenak for/
Dennis C. Morey, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Project No. 728 Docket No. 99902041
Enclosure:
As stated OFFICIAL USE ONLY - PROPRIETARY INFORMATION
ML20154K138 (Package)
ML20154J959 (Letter)
ML20154J954 Draft SE
- concurrence via email NRR-106 OFFICE NRR/DORL/LLPB* NRR/DORL/LLPB* NRR/DSS/SNPB NRR/DORL/LLPB NAME MOrenak for NOtto DHarrison RLukes DMorey DATE 06/4/20 06/4/20 06/5/20 06/5/20