REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.: NR-8095-D-808-S DATE:
OCT 0 71998 PAGE 1 OF 5 DEVICE TYPE:
Source Storage Assembly MODEL:
CDV-791, CDV-792 MANUFACTURER / DISTRIBUTOR:
Federal Emergency Management Agency (FEMA) 500 C Street S.W.
Washington, DC 20472 ISOTOPE:
MAXIMUM ACTIVITY:
LEAK TEST FREOUENCY:
Not Required l
PRINCIPAL USE:
(T) Other Note: This is the storage and shipment container P. hat was used by FEMA for their sources.
i CUSTOM DEVICE:
YES X
NO 9810150044 981007
~
_~ _
I REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF-DEVICE
.]
OCT 0 71998 i
NO,: NR-8095-D-808-S DATE:
~
PAGE 2 OF 5 1
DEVICE TYPE:
Source Storage Assembly e
DESCRIPTION:
i The CDV-791/CDV-792 is a steel clad lead containment system used.
by FEMA and-its contractors to transport and store millicurie quantities of Co-60 or Cs-137 that is doubly encapsulated.. The radioactive materials are placed in a CDV-791 first, a smaller, steel. shielded, lead filled container which is then placed in the CDV-792. The CDV-791 is cylindrical in shape with an outer diameter of 3-5/8 inches (92.1 mm) and a height of 3-7/16 (87.31mm). The CDV-792 is cylindrical with an outer-diameter of 8-3/4 inches (222.3 mm) and a height (excluding handles) of 8-5/8 inches (219.1 mm).
The container contains an
' internal cavity with a diameter of 4-3/8 inches (111.1 mm) and a depth of 5-1/4 inches (133.4 mm). The lid is secured with four bolts 90 degrees apart.- Two of the bolts, 180 degrees apart, are i
permanently welded to the flange on the container.
The' remaining i
two bolts are removable and are replaced by padlocks during i
storage.
The removable bolts contain a transverse hole through the bolt near the end where the nut is placed.
After the nut is secured,.a wire seal is placed-through this hole and crimped to prevent unauthorized opening.
The nut cannot be removed without breaking this seal.
i The container and lid each contain handles for lifting the container.and removing the lid.
A CDV-792 container without the lid. weights approximately 140.lbs (63.4 kg).
The lid weighs an additional 45 lbs (20.4 kg). The CDV-191, inner container, weights 16 lbs (7.2 kg).
The maximum total shipping weight of a complete assembly will weigh no more than 210 lbs (95.1 kg).
j DIAGRAMS:
See' attachments 1 and 2.
LABELING:
j The CDV-791 has the trefoil symbol, as well as, the words l
"CDV-791, Model 4," and the serial number (to be the same as the j
serial number assigned to the CDV-792 it accompanies).
4 -
L l
l t
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE OCT 0 71998 NO.: NR-8095-D-808-S DATE:
PAGE 3 OF 5 DEVICE TYPE:
Source Storage Assembly LABELING: (Cont.)
The CDV-792 has three adhesive backed labels affixed to it. One label contains the words "OCD Item No.
CDV-792, Model No.
4, Serial No.,
Radioactive Material, B.E. Permit No.
- 361, I.C.C, No.
55xxx", and the manufacturer's name, city and state.
The secono label contains the words " USA DOT 7A Type A,"
" Radioactive Material, Federal Emergency Management Agency, Washington,
D.C." and tde gross weight of the container 210 lbs.
The third label is affixed to the lid and meets the requirements of 10 CFR 20.1901 and 20 CFR 20.1904.
CONDITIONS OF NORMAL USE:
The Model CDV-791 and CDV-792 are used to provide sufficient shielding and containment for FEMA sealed sources during storage or transport.
In addition, these containers are designed to maintain their performance for the normal and accident conditions characteristic of a Department of Transportation Type A Package.
PROTOTYPE TESTING:
l The CDV-792 container was tested in accordance and meets the l
Departmer.t of Transportation (DOT) Type A Packaging requirements l
that inciuded the following:
- Free drop test
- Penetration test Compression test l
[
The CDV-191 was omitted from testing since it is not considered an integral structural part of the containment system.
EXTERNAL RADIATION LEVELS:
When a single source containing 10 millicuries (370 MBq) of Co-60 is placed in the CDV-791, the gamma exposure rate at any point on the surface of the container shall be less than 1.5 R/hr (15 mSv/hr).
l i
i REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO,; NR-8095-D-808-S DATE:
OCT 0 719$8 PAGE 4 OF 5 DEVICE TYPE:
Source Storage Assembly EXTERNAL RADIATION LEVELS: (Cont.)
When a single sealed source containing 10 millicuries of Co-60 is placed inside the combination of both (the CDV-791 inside the
)
CDV-792) containers, the gamma exposure rate at any point on the surface of the CDV-792 container shall be less than 25 mR/hr (0.25 mSv/hr).
OUALITY ASSURANCE AND CONTROL:
Federal Emergency Management Agency had a quality and control program which was deemed acceptable for licensing purposes by the NRC.
I LIMITATIONS AND/OR OTHER CONSIDERATIONS OF USE:
- This device may be used only by specific licensees of the NRC or Agreement States.
i
- These devices will no longer be commercially distributed but may still be approved for licensing purposes.
This registration sheet and the information contained within the references shall not be changed without the written consent of the NRC.
SAFETY ANALYSIS
SUMMARY
FEMA had notified the NRC that effective August 15, 1996, radioactive sources in their possession would be either transferred to a properly licensed recipient or disposed of as radioactive waste.
These devices had been previously deemed acceptable for licensing purposes by the NRC.
Based on the DOT Type A Packing Classification for the Model CDV-792, we continue to conclude that these containers are acceptable for specific licensing.
r I
REGISTRY OF RADIOACTIVE-SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE 07M NO.: NR-8095-D-808-S DATE:
PAGE 5 OF 5 DEVICE' TYPE:
Source Storage Assembly
' SAFETY ANALYSIS
SUMMARY
- (Cont.)
Furthermore, we continue to conclude that these containers would be expected to maintain their shielding integrity for normal
~ conditions of use and accidental conditions which might occur
'during uses specified in this-certificate.
REFERENCES:
The'following supporting documents for the CDV-791 and CDV-792 Source Storage Assemblies-are hereby incorporated by reference and are made a part of this registry document:
- Federal Emergency Management Agency letter dated March 17, 1997.
- Federal Emergency Management Agency memorandum " Compliance Testing of the CDV-792: Container as a DOT Type A Package" dated April 9, 1981.
- Office'of Civil Defense Standard Item Specification revised November 1, 1959, for the Model'CDV-791 and CDV-792.
ISSUING AGENCY:
l~
U.S. Nuclear Regulatory Commission
-Date:
Reviewer:
YuM ow t
'Michele L Burge5fs l
l OCT 0 71998 Date:
Concurrence:
7 n W.
Lubinski d
8 l
l i
REGISTRY OF RADIOACTIVE SEALED SOURCES'AND DEVICES SAFETf EVALUATION OF DEVICE
)
h NR-8095-D-808-S DATE: OCT 0. 7 1998 -
ATTACHMENT 1 i
I REVISED N OV. I,19 5 9 CD V.- 791
)
3 n
1 I
i I
Loo 3eq.
(fd i
-- 9 E ____.
1 l
)
i l
17-24 TN3 2/lOLES CONTAINER 70 BE BREAK CORNERS RLLED W/TH LEAD A *0PTIONAL 1
A
/20SH WITH TOP
+
+
l6 ONT. WELO h
.!. 0. R. MA X.
m.. y pe #g, 4
A i
s
.f e
2
+
e20 GA.
l 7
I.
l Si i
U 1
- 0. C. D.
f" p y
MATERIAL AAILD. STEEL
U FINISH SEE 4.3 l
A-5
.u
n i
f i
REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES l
SAFETY EVALUATION OF DEVICE l
1 NO,; NR-8095-D-808-S DATE: OCT 0 71998 ATTACHMENT 2 I
i V ',1, y CO V-792 CON TalNER AS$ Y
- E v'sto nov n. osse g
45'
/
N.
7 N
Eald
/
N
/
ms
/
\\
Lu!L^ T /
l N/
I x
\\,M f
e r
,,f
\\l d=,
-M
}
l u/
, t e!*4
,_ \\ '
\\.
l fj i p
/
/
\\
')N
\\
sj gi
..,m-l
/
i
/
_....ff.
\\
f
/
f fM OMTLL FOR RTf fL ll W
tvL rett e rhg LONG E !!N D!A
- Mf LD DOVN S *Of $ Of **ekOL f S M $ %f u C, *tnO 4TER f!L L f NQ (DMfNUOds ofL t
l k?k
{3e.}4a-if
. *n.t KAL *,
- I H 'r -;) x2 ::::: "." la L ?! R
) l}
=-
e t'
"i",hj!Td[fhNL,,,,
!h If i
j
.u..a a
u = u....
wfLD ?09(M" i
$$ 2k dfM.
N~ [ *b l^
l Ti ts, 1 >.e.e oprio~n y n o V4 MAE OM ge h pA A QR C e y, MA A On Capt ofLDy SALLE l
O
\\
N f
a+t.-
Vemon L. Wingert :
M 0 7 w-Chairperson, Radiation Control Committee Federcl Emergency M:nagement Ag ncy 500 C Street S.W.
Washington, DC 20472
Dear Mr. Wingert:
1 Based on the request submitted in your letter dated March 17,1997, we have transferred the following registration certificates below to inactive status. The registration numbers of the certificates have been changed:
FROM TO MODEL(S)
NR-283-D-801-S NR-8095-D-801-S UDM1 A (CDV-793)
NR-283-D-802-S NR-8095-D-802-S CDV-795 NR-283-D-803-S NR-8095-D-803 S CDV-798 NR-283-D-101-S NR-8095-D-804-S CDV-757 NR-283-S-102-S NR-8095-S-805-S CDV-778, CDV-782, CDV-784, CDV-786 NR-283-D-105-S NR-8095-D-806-S CDV-794, Model 2 NR-283-D-106-S NR-8095-D 807-S CDV-797
/
NR-283-D-110-S NR-8095-D-808-S CDV-791, CDV-792 NR-283-D-111-S NR-8095-D-809-S CDV-790, Model 1 Please review the registration certificates (copies enclosed) in their entirety and notify us immediately if there are any errors or omissions.
If you have any questions, please contact me at (301) 415-5799 or Michele Burgess at (301) 415-5868.
Sincerely, 6
Eric B. Compton, Engineering Aide Materials Safety Branch Division of Industrial and Medical Nuclear Safety Office of Nuclear Material Safety and Safeguards
Enclosures:
As stated cc w/ encl: SKimberley, LFDCB Distribution:
SSSS r/f NE01 NR-8095-D-801-S NR-8095-D-802-S NR-8095-D-803-S NR-8096-D-804-S NR-8095-S-805-S NR-8095-D-806-S NR-8095-D-807-S NR-8095-D-808-S NR-8095-D-809-S
' DOCUMENT NAME: H:\\ERIC\\COMPl_TR\\N80958XX.WPD Ta receive e copy of this document. Indicate in the box: "C" = Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N" = No copy OFFICE MSB l c. MSB lE i
l NAME ECompton c
MBurgess > u.
DATE 9/n /98 9/. ;/98 OFFICIAL RECORD COPY I
gg wAS-c&{-
i retu i
'p UNITED STATES t
- NUCLEAR REGULATORY COMMISSION
- U j
wAsw Norow, o.c. soessaan I
- ,/
l
}
l l
I NOTE TO:
- SSD97-23/28 i
Federal Emergency Management Agency (FEMA)
FROM:
Eric B. Compton, Engineering Aide Materials Safety Branch r-
[gm ^
Division ofindustrial and Medical
(&
l Nuclear Safety i
Office of Material Nuclear Safety and Safeguards DATE:
September 14,1998 RE:
REFERENCES NOT FOUND IN FILE l
i
' in the process of transferring several of FEMA's registration certificates to inactive status it was i
discovered that a number of items which had been referenced in the original registration certificates were not in the background file. These included the following:
l 1.
Federal Civil Defense Administration Standard item Specification dated May 23,1956, I
for the Model CDV-786.
2.-
Office of Civil and Defense Mobilization letter dated April 6,1959, s'ating that the l
CDV-784 was to replace the CDV-786..
3.
Manual of Procedure for the Use and Control of the CDV-778 Radiation training Source Set dated August 1975.
4.
- Equipment Manual /Use and Control of the CDV-798 Model I Radiological Survey Meter Calibrator dated August 1975.
5l Federal Emergency Management Agency letter dated February 17,1983, with enclosures thereto.
6.
Federal Emergency Management Agency renewal applicatinn for Materials License L
No. 08-01297-06, dated August 10,1992 with enclosures thereto.
1
[
L:
j
$Y O
y- ' -e a
ww yy-g r,
w
-w--
7 w,
1 April 2,1997 i
ASSIGNMENT NUMBER: 97-23 to 97-28 Mr. Vemon Wingert j
Federal Emergency Management Agency 500 C Street S.W.
Washington, DC 20472 l
i
SUBJECT:
ACKNOWLEDGEMENT OF REQUEST FOR SAFETY EVALUATION i
Dear Mr. Wingert:
This letter acknowledges the receipt of your March 17,1997, application that requested a safety evaluation and registration of various Models. We have performed a cursory review of your application and determined that enough information has been provided to allow a technical reviewer to initiate the evaluation process. Applications are assigned to technical j
reviewers on a first-in basis. Therefore, your application will be assigned in turn. Please note that the technical reviewer may contact you to request information that wac omitted from your application or to obtain clarification of technicalissues conceming your application. If you i
have any questions concerning the status of your application, please contact me at (301) 415-7857. Please reference the assignment number listed above in your questions or i
correspondence.
Please be aware that your request may be subject to the NRC's application fees in i
accordance with 10 CFR Part 170. Therefore, a copy of your application has been forwarded to the License Fee and Debt Collection Branch for approval of the fee category and amount.
l
!f you have any questions concerning the fees associated with your application, please contact the Licen e Fee and Debt Collection Branch at (301) 415-7554.
Sincerely,
/ Sl KimBerly Randall, Registration Assistant Sealed Source Safety Section Medical, Academic, and Commercial Use Safety Branch Division of Industrial and Medical Nuclear Safety Office of Nuclear Material Safety and Safeguards Distribution:
SBaggett SSSS r/f SSD-97-23 to 97-28 NE01 SSD File #
NR-283-D-101-S NR-283-S-102-S NR-283-D-105-S NR-283-D-106-S N
NR-283-D-111-S l
l DOCUMENT NAME:P:97-23.wpd I-in receive e copy of this document, indicate in the boa:
'C" = Copy without attachment / enclosure "E" = Copy with attachment /enclosura "W = No copy OFFICE IMAB g
NAME KRanda F DATE 4/.2197
, -- m PAGE1 j
NRC FORM 567 U. S. NUCLEAR REGULATORY COMMISSION i
i REQUEST FOR A SEALED SOURCE OR DEVICE EVALUATION INSTRUC110NS: Send this request AND a copy of all reisted lettere/apphcetions and drawings to: The Sealed Source Safety Section, ATTN: Chief, OWFN Mall Stop 6 H3. Change the Ucense Tracidng System milestone to 19 and seeign to reviewer code I-5.
NOTE: Retain a copy of this request with the appl 6 cation e.1d background files.
REQUESTER REGION / LOCATION:
IN ll ll Ill IV UV R HQ C LFDCB TELEPHONE NUMBER DATE TYPE OF ACTION REQUESTED (Check as ~...A)
APPUCANTS NAME SOURCE REVIEW AMENDMENT OF g/MoA
@d/
REGISTRATION SHEET DEVICE REVIEW NUMBER (S)
MAIL CONTROL NUMeER(S)
D UCENSE NUMBER (S)
CUSTOM REVIEW N
8 ~~
N~A LETTER /APPUACA I?lA1y peg w tt gaafup
&xitwu+ Wey-
~ ~~ '
9y L.
& cCf 3' N
- mash Aa'~hc Av2L L/
FOR SSSS USE ONLY REVIEWER MODEL NUMeERS NUMBER ASSIGNED
('T2-H/, av-79e 97 ~~c27 4li/f?
v'/x/H'
" " " ~
~~
~ ~ "
I
'/
TYPE OF ACTION (Indicate the number of each type) l COMMERCIAL DISTRIBUTION (FORMAL) l USE BY A SINGLE APPLICANT (CUSTOM)
SOURCE (9C)
DEVICE (9A)
SOURCE (9D)
DEVICE (98)
NEW.
NEW
~
AMENDMENT AMENDMENT NEW s
NEW M ENDMENT AMENDMENT JO SAFETY EVALUATION REQUIRED j LICENSING ACTION REQUIRED IF KNOWN NO NO FEES REQUIRED joTHER (Specify)
TOTAL NUMBER OF NOTESgh /Mb REVIEW HOURS NUMBER OF DEFICIENCY LETTERS NUMBER OF DEFICIENCY CALLS FOR BILLING PURPOSES ONLY NEW REGISTRATION -
] PRODUCT INACTM -
NAME CHANGE ADDRESS CHANGE ADD TO BILLING REMOVE FROM BILLING FOR FEE USE ONLY TYPE OF FEE -
FEE CATEGORY
~
9C U 9D 7 9A R 98 h (Q#
AMOUNT RECErVED CHECK NUMBER MATANN UPDATED
\\
~ AS REQUIRED DATE OF CHECK
,V
,3 J'
LOG c
/ j Q[)
] MATSYS UPDATED j
4 (
AS REQUIRED APPROVED gy
(
VT DATE RETURN DATE COMMENTS NRC FORM Se7 p.e3) lh
-- ~~
m Federal Emergency Management Agency Washington, D.C. 20472 March 17, 1997
=
Mr. Steven Baggett U.S. Nuclear Regulatory Commission Sealed Source Safety Section Source Container and Devices Branch Division of Industrial and Medical Nuclear Safety, NMSS Washington, D.C. 20555-0001
Reference:
NRC License No. 08-01297-06 Docket.No. 030-7130
Dear Mr. Baggett,
T'he Director of the Federal Emergency Management Agency (FEMA) made the decision to close the National Instrumentation Center (NIC) at the Mt. Weather Emergency Assistance Center (MWEAC), Bluemont, Virginia, effective August 15, 1996.
in in the possession of FEMA at the NIC are Radioactive Sources temporary storage, awaiting either the transfer to a properly licensed recipient or disposed of as radioactive waste.
radioactive sources owned by The licensed recipient who possess FEMA will either retain possession of the sources, or dispose of them as radioactive waste.
it is requested that the following Due to the closure of the NIC, registry numbers in our License be given inactive status:
NR-283-D-101-S NR-283-S-102-S NR-283-D-105-S NR-283-D-106-S NR-283-D-110-S NR-283-D-111-S The following registry numbers are inactive:
NR-283-D-801-S NR-283-D-802-S NR-283-D-803-S It is anticipated that the annual fees for the devices covered by each registry number will be frozen for FY 1998.
We are currently in the process of reconciling and updating our computerized inventory Radioactive Materials (RAM) Data-Base to reflect what we currently own and possess and what radioactive material and devices have been transferred to licensed recipients disposed of as radioactive waste.
When completed, we will or provide you with an updated inventory.
IV0500%
a s,.
I would be happy to discuss any questions or concerns that you or your staff have regarding this letter.
I can be reached at (202) 646-2872.
Sincerely, 3
ti v
Vernon L.
Wingert Chairperson, Radiation Control Committee (RCC) cc:
Elaine Chan (OGC)
Robert P.
Fletcher, Jr. (PT-SL)