_

DISTRIBUTION:

NRC File Center ESuarez Case File ADella Ratta, RI I

' Docket"Filii 70 371 -

RKeimig, RI SGLB r/f EWBrach SGLB Central File SG Amendment File SGLB RLJ 70-371 MAY 161988 NMSG-e/+-

pp(

RLJackson guhJ c}

PTing gggg UNC N,aval Products

. Division of UNC P.esources, Inc.

ATTN: Mr. Tom Collopy, Manager Nuclear Material Control 67 Sandy Desert Road Uncasville, Connecticut 05382-0981

Dear Mr. Collopy:

This is in response to your April 25, 1988 request for an exemption from the requirement of 10 CFR 70.58(g)(3) to take appropriate investigative and correc-tive action to reconcile shipper / receiver differences that are statistically significant at the 95 percent confidence level axcept those shipments which involve differences of 50 grams or less of U-235.

In place of this requirement you propose early implementation of 10 CFR 74.59(h)(1)(iii) which requires investigative and corrective action to reconcile shipper / receiver differences involving finished fuel shipments that are statistically significant at the 95 percent confidence level and the shipper / receiver difference exceeds the larger of 0.5 percent of the amount of Strategic Special Nuclear Material (SSNM) in the container, lot, batch, or shipment, as appropriate, or 50 grams of SSNM.

We have reviewed your request and have determined that granting it will not adversely affect the comon defense and security nor the public health and safety and is otherwise in the public interest. Accordingly, we are adding a new License Condition 8.1 to Amendment SG-1 to your License No. SNM-368, effective immediately, to read as follows:

8.1 Notwithstanding the requirement of 10 CFR 70.58(g)(3) to take appro-priate investigative and corrective action to reconcile shipper / receiver differences that are statistically significant at the 95 percent confidence level except those shipments which involve differences of 50 grams or less of U-235, the licensee may take investigative and corrective action when shipper / receiver differences exceed twice the estimated standard deviation of the difference estimator and the larger of 0.5 percent of the amount of SSNM in the container, lot, batch, or shipment, as appropriate, or 50 grams of SSNM.

We have determined that your letter dated April 25, 1988 contains information of the type specified in 10 CFR 2.790(d). Accordingly, pursuant to Section OP'3 e009210209 000516 PDR ADOCK 0700 1

MAY 161988 UNC NVL PRO 2.790(d)(1), such information is deemed to be comercial or financial within the meaning of 10 CFR 9.5(a)(4) and shall be withheld from public disclosure unles,s subject to the provisions of 10 CFR 9.12.

Sincerely,

[

Robert F. Burnett, Director Division of Safeguards and Transportation, HMSS closes:07000371E20H

..lE9bE.

a..l50b.

....l$$hE.)...... S$bO.' '..... ESSE -y$.. $$b.B

,,,,l,,,,,,,,,

.[3[ya,,ksp h,l jjuayp3,,,,,l,P, jp,,,,,,,l f,W,, h,,,,,l,E,0,T,,n,fyp,k,, f,F,B,u,E,n,e,t,t,,,3,,,,,,,,,

DATE :05/9/88

05/10/88
05/ 4 /88
05/g /88
05/[0 /88
M/ /88 L