MAY 2 01988
In Reply Rofer To:
Dockets:
50-445/88-32
'
50-446/88-28
TU Electric
ATTN:
Mr. W.
G. Counsil
l
Executive Vice President
i
i
400 North Olive Street, Lock box 81
Dallas, Texas
75201
Gentlenent
l
l
This refers to the inspection conducted by Mr. P. 3tanish and other
i
NRC consultants during the period April 6 through May 3, 1988, of
activitics authorized by NRC Construction Permits CPPR-126 and
i
l
CPPR-127 for the Comancho Peak Steam Electric Station, Units 1
l
and 2, and to the discussion of our findings with
Messrs. L. D. Nace, A. B. Scott, and other members of your staff at
the conclusion of the inspection.
>
The enclosed copy of our inspection report identifics areas
examined during the inspection.
Within those areas, the inspection
consisted of selectivo examination of procedures an.) representative
I
records, interviews with personnel, and observatiota by the
inspectors.
During this inspection, it was found that certain of your
activitics were in violation of NRC requirements, as specified in
the enclosed Notice of Violation.
A written response to this
!
violation is required.
In accordance with 10 CFR 2.790 of the Commission's regulations, a
copy of this letter, the enclosures, and your response to this
letter will be placed in the NRC Public Document Room.
The response directed by this letter and the accompanying Notice is
not subject to the clearance procedures of the Office of Management
and Budget as required by the Paperwork Reduction Act of 1980,
l
PL 96-511.
RFid
IP:CPPD:OSP
AD:IP:CPPD:OSP
HLivermoreNg
RWarnick
5/11/88
5/Ro/88
8805250207 800500
POR
ADOCK O'.X)OO4 4 5
G
ppR
l
.
..
.
_
. __ _
_
.
_
.
- _ _ _
'
TV Electric
2
MAY 2 01988
.
!
should you have any questions concerning this inspection, we will
be pleased to discuss them with you.
Sincerely,
ORIGINAL SIGNED BY H. F. WARNICK
'
R.
F. Warnick, Assistant Director
.]
for Inspection Programs
l
Comanche Peak Project Division
Office of Special Projects
Enclosures:
Appendix A - Notice of Violation
Appendix B - Inspection Report 50-445/88-32; 50-446/88-28
cc w/ enclosures:
'
See next page
,
!1
4
>
s
I
!
i
1
l
s
b
,
. . - - . . . - - - - - , _ - , _ ,
e
9
50-445/80-3.2; 50-446/28- 2
DISTRIBUTION:
T.f Dock. et~ Files.. ' ( 50-4 4 5. / 4 4 6').'
p
,
Local PDR
OSP Reading
CPPD-LA
CPPD Reading (HQ)
- Site Reading File
AD for Projects
- Sr. Lead Insp. - CONST.
- Concurrence
- MIS System, RIV
- RSTS Operator, RIV
DRP, RIV
RIV Docket File
- LShea, ARM /LFMB
JTaylor
SEbneter/JAxelrad
CGrimes
PMcKee
JLyons
JWilson
JMoore, OGC
JGilliland, RIV
FMiraglia
EJordan
JPartlow
.
BHayes
- w/766
i
J
,
l
l
. _ .
. _ _ _
.
[ a atc ,Io
,
s
o
UNITED STATES
,,
NUCLEAR REGULATORY COMMISSION
y
-
p,
g
E
WASHINGTON, D C. 20555
MAY 2 01988
.....
In Reply Refer To:
Dockets:
50-445/88-32
50-446/88-28
TU Electric
ATTN:
Mr. W. G.
Counsil
Executive Vice President
400 North Olive Street, Lock Box 81
Dallas, Texas
75201
Gentlemen:
This refers to the inspection conducted by Mr.
P.
Stanish and other
NRC consultants during the period April 6 through May 3,
1988, of
activities authorized by NRC Construction Permits CPPR-126 and
CPPR-127 for the Comanche Peak Steam Electric Station, Units 1
and 2, and to the discussion of our findings with
Messrs. L. D. Nace,
A.
B.
Scott, and other members of your staff at
the conclusion of the inspection.
The enclosed copy of our inspection report identifies areas
examined during the inspection.
Within these areas, the inspection
consisted of selective examination of procedures and representative
records, interviews with personnel, and observations by the
inspectors.
During this inspection, it was found that certain of your
,
activities were in violation of NRC requirements, as specified in
the enclosed Notice of Violation.
A written response to this
violation is required.
j
In accordance with 10 CFR 2.790 of the Commission's regulations, a
copy of this letter, the enclosures, and your response to this
'
letter will be placed in the NRC Public Document Room.
The response directed by this letter and the accompanying Notice is
not subject to the clearance procedures of the Office of Management
and Budget as required by the Paperwork Reduction Act of 1980,
PL 96-511.
-
..
.
,
.
.
.
...-
.
.
%
TV Electric
2
MAY 2 01988
.
Should you have any questions concerning this inspection, we will
be pleased to discuss them with you.
Sincerely,
R F luku&
.R.
F. Warnick, Assistant Director
for Inspection Programs
Comanche Peak Project Division
office of Special Projects
Enclosures:
Appendix A - Notice of Violation
Appendix B - Inspection Report 50-445/88-32; 50-446/88-28
cc w/ enclosures:
See next page
,
!
\\
4
l
l
s
.
.
.
.
.
.
.
.
. .
- - _ _ _ _
.
TU Electric
'
cc w/ enclosure:
Roger D. Walker
Nancy H. Williams
Manager, Nuclear Licensing
CYGNA Energy Services
Texas Utilities Electric Company
Suite 390
Skyway Tower
2121 N.
California Blvd
400 North Olive Street,
L.B.
81
Walnut Creek, CA
94596
Dallas, TX
75201
Robert A. Wooldridge, Esq.
Juanita Ellis
Worsham, Forsythe, Sampels
President - CASE
and Wooldridge
1426 South Polk Street
2001 Bryan Tower
Dallas, TX
75224
Suite 2500
Dallas, TX
75201
Susan M. Theisen
Assistant Attorney General
Mr. Homer C. Schmidt
Environmental Protection Division
Director of Nuclear
P.O.
Box 12548, Capitol Station
Services
Austin, TX
78711-2548
TU Electric
Skyway Tower
Administrative Judge Facer Bloch
400 N. Olive St.,
L.B.
81
U.S. Nuclear Regulatory Commission
Dallas, TX
75201
20555
Elizabeth B. Johnson
Kennett A. McCollom
Administrative Judge
Administrative Judge
Oak Ridge National Laboratory
1107 West Knapp
Post Office Box X, Building 3500
Stillwater, OK
74075
Oak Ridge, TN
37830
GDS Associates, Inc.
Jack R. Newman, Esq.
1850 Parkway Place, suite 720
Newman & Holtzinger,
P.C.
Marietta, GA
30067-8237
1615 L Street,
N.W.,
Suite 1000
D.C.
20036
Mr.
R.
W.
Ackley
Stone & Webster Engineering
Walter H. Jordan
Corporation Project Mgr.
Administrative Judge
881 West Outer Drive
P. O.
Box 1002
Oak Ridge, Tennesee
37830
Glen Rose, Texas
76043
Anthony Z.
Roisman, Esq.
Mr.
J.
L. Vota
Suite 600
Westinghouse Electric
1401 New York Avenue, N.
W.
Corporation
20005
Post Office Box 355
Pittsburgh, PA
15230
Ms. Billie Pirner Garde, Esq.
Government Accountability Project
Lanny A. Sinkin
Midwest Office
Christic Institute
i
104 East Wisconsin Avenue
1324 N.
Capitol Street
,
Appleton, WI
54911
20002
--
-
.
.
- . -- - - - - - - . . -
_ _ . - _ . _ . _ _
.
TU Electric
'
cc w/ enclosure:
(continued)
David R. Pigott, Esq.
Orrick, Herrington & Sutcliffe
600 Montgomery Street
San Francisco, CA
94111
Robert Jablon
Bonnie S.
Blair
Spiegel & McDiarmid
1350 New York Avenue, NW
20005-4798
George A. Parker, Chairman
Public Utility Committee
Senior Citizens Alliance of
Tarrant County, Inc.
6048 Wonder Drive
Fort Worth, TX
76133
Joseph F. Fulbright
Fulbright & Jaworski
1301 McKinney Street
Houston, TX
77010
Mr. Jack Redding
c/o Bethesda Licensing
TU Electric
3 Metro Center, Suite 610
Bethesda, MD
20814
William A. Burchette, Esq.
Counsel for Tex-La Electric
l
Cooperative of Texas
Heron, Burchette, Ruckert &
'
Rothwell
Suite 700
1025 Thomas Jefferson St., NW
20007
.
Regional Administrator, Region IV
U.S. Nuclear Regulatory Commission
{
611 Ryan Plaza Drive, Suite 1000
Arlington, Texas
76011
i
l